首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The first-order Raman band of diamond anvils has been investigated at pressure up to 380 GPa in order to develop an optical pressure determination method. The high frequency edge of the band was calibrated by the pressure scale of the equation of state of Pt. The universality of the relationship between the sample pressure and the edge-frequency was confirmed up to 370 GPa and the usefulness of the diamond anvil Raman gauge was demonstrated. Using the diamond anvil Raman spectroscopy, the stress-state of the anvil culet was directly observed in the multimegabar pressure range. Obtained pressure dependence of the shear stress suggested further extension of feasible pressure beyond 400 GPa.  相似文献   

2.
Permanent density increase of silica glass was used to calibrate pressure generation delivered by cupped sintered diamond anvils (‘dimple anvils’) [Haberl B, Molaison JJ, Neuefeind JC, et al. Simple modified Bridgman anvil design for high pressure synthesis and neutron scattering. High Press. Res. submitted] within the Paris-Edinburgh press between approximately 9 and 20?GPa. Raman spectral changes of recovered silica glass with increased density were used to determine the maximum pressure reached by following an established calibration curve [Deschamps T, Kassir-Bodon A, Sonneville C, et al. Permanent densification of compressed silica glass: a Raman-density calibration curve. J. Phys. Condens. Matter. 2013;25:025402]. The monotonic Raman shift of the Main Band spectral region (~200–700?cm?1) of silica glass recovered from 9 to 20?GPa allows for continuous pressure calibration and is applicable to all presses that operate within this pressure range. Radial & axial Raman profiles were conducted to determine the pressure distribution within the sample chamber. This technique has been verified by in situ resistance measurements of the insulator-to-metal phase transition of ZnS near 15?GPa.  相似文献   

3.
High-pressure powder neutron diffraction of wüstite-Fe0.93O has been achieved to 12 GPa using a large gem-moissanite (SiC) anvil cell. The moissanite anvils are weakly absorbing and provide greater neutron fluxes to the sample than is possible with tungsten carbide anvils. There is minimal diffraction overlap from the single-crystal moissanite anvils compared to tungsten carbide or synthetic diamond anvils, providing cleaner background profiles. The required sample volume for high-pressure neutron diffraction is dramatically reduced to several cubic millimeters. High-quality powder diffraction patterns of wüstite were recorded at 90 min exposure times on the HIPPO diffractometer at LANSCE when the sample volume was in the range of ~10 mm3. This is about two orders of magnitude smaller than the necessary sample volume (~1.0 cm3) for the same kind of experiment with other high-pressure cells and nominal neutron fluxes.  相似文献   

4.
We describe some important improvements allowed by the development of new cell assemblies coupled to opposed conical sintered diamond anvils in the Paris–Edinburgh press. We provide X-ray absorption and diffraction experiments carried out at pressures up to 16.5 GPa. The maximum temperature reached was 1800 K for P<10 GPa and 1300 K for higher pressures. The sintered diamond anvils are X-ray transparent and give access to a much larger X-ray window than the tungsten carbide anvils, even at the highest pressure. Therefore, X-ray measurements are performed using in situ cross-calibration simultaneously. We also describe a new heating setup used to reach high temperatures, despite the low conductivity of the sintered diamond core by deviating the electrical current using copper strips. These improvements are illustrated by recent data collected using angle dispersive in situ X-ray diffraction on liquid Fe-18%wt S and using EXAFS at the barium K-edge on Ba8Si46 silicon clathrates and at the iodine K-edge on iodine-intercalated nanotubes.  相似文献   

5.
Using a hot isostatic pressing (HIP) technique, we synthesized diamond/SiC composites from diamond and Si powders. At an HIP condition of 1450 °C and 100 MPa, a pressure much lower than that of the diamond stability field, diamond powders react with molten Si to form well-sintered diamond/SiC composites. Cubes of the composites with 15 mm edge length were thereby fabricated, and an application to the second stage anvils in a Kawai-type high-pressure apparatus was attempted. A hybrid anvils system using four cubes of the composites and four of the conventional WC was introduced and heating experiments up to 1600 °C became possible. Because the diamond/SiC composites are transparent to X-rays, the present system is applicable not only to diffraction studies but also to radiographic studies that need a larger window for an X-ray image.  相似文献   

6.
Stress distribution in cemented tungsten carbide (WC) anvils is of primary interest in high pressure research, but is very difficult to determine experimentally. We have performed finite-element simulations to study the performance and the shear stress distribution of WC anvils used in the China-type cubic-anvil high pressure apparatus (SPD-6×2000). Our results show that in order to avoid failure cracks in high-stress areas, the maximum shear stress should be lower than 3.17 GPa for the WC anvils (8% cobalt). The simulations have been verified by high-pressure experiments. Our method of analyzing stress distribution helps in evaluating the ability of WC anvils, and would aid in designing a new anvil to enhance performance.  相似文献   

7.
In this paper, we report on the bulk modifications of type IIa single-crystal diamond with visible 10-ps pulses (at λ = 532 nm) and microstructural changes characterized by the appearance of several ‘unidentifiable’ vibrational modes in the frequency range of 1000–1400 cm?1 in the Raman spectra of laser-modified diamond. It is found that the new Raman modes are strongly pronounced in the spectra of high-stress regions in immediate proximity to the bulk microstructures in the absence of the G mode at ~1580 cm?1 characteristic of the sp2 phase. The high internal stresses are determined from the splitting of the triply degenerate diamond Raman line. The revealed structure transformation is localized within a narrow bulk layer near the bulk microstructures formed, and the stress relaxation is found to result in disappearance of the detected vibrational modes in the spectra. It is suggested that the formation of bulk regions with a sp3 carbon structure consisting of Z-carbon and hexagonal diamond is responsible for the appearance of new Raman modes in the spectra of laser-modified diamond. These findings evidence that the stress-assisted formation of novel metastable carbon phases or defect structures occur in the course of bulk modification of diamond with ps-laser pulses. In addition, we report the results of simulations of internal stresses in the system ‘graphitized cylinder-in-diamond’ to show (1) the effect of the mechanical properties of laser-modified diamond on the resulting stresses and (2) formation of bulk microscopic regions with high stresses of >10 GPa, i.e., the conditions at which various sp3 carbon allotropes and defect structures become more stable than graphite.  相似文献   

8.
The extraordinary properties of diamond make it the number-one choice for anvils in high pressure experiments involving anvil cells. In much of the literature on the properties of diamond the only cleavage mentioned is {111}. However, experience has shown that diamond anvils made with their [001] axis oriented in line with the principal stress axis of the anvil or at a small angle to it often failed with flat faces having {110} orientations; a cleavage plane is reported in some publications. Analysis of the anisotropy of strength and Poisson ratio in diamond has shown that such orientations do, indeed, favor initial failure on {110} cleavage planes. This analysis, in conjunction with stereographic projections of the {111} and {110} cleavage planes, suggests that a 27° tilt of the [001] axis with respect to the linear stress axis by rotation around the [100] or [010] axis should provide significantly greater resistance to failure by cleaving.  相似文献   

9.
We present quantitative measurements of the macroscopic non-hydrostatic stress and of the microscopic stress in samples compressed in a diamond anvil cell, using helium as a pressure-transmitting medium. These are based on the analysis of X-ray diffraction line shifts and widths. The macroscopic non-hydrostatic stress reaches 0.3–0.5 GPa at 150 GPa when the sample remains embedded in the pressure medium. The effect of this non-hydrostatic stress on the measured equations of state is estimated in the cases of gold, silver, molybdenum and copper. It is found to be negligible, except in the case of gold. We show that the analysis of the X-ray diffraction line shifts is a more sensitive way of detecting non-hydrostatic compression than the monitoring of the ruby luminescence signal. It can be used to detect when the sample is directly compressed between the diamond anvils. The sample geometry, in particular its thickness, has to be carefully chosen to prevent that situation.  相似文献   

10.
Using designer diamond anvils and angle dispersive X-ray diffraction technique at a synchrotron source, we have performed simultaneous electrical and structural studies on neodymium metal to 152 GPa in a diamond anvil cell. Four-probe electrical resistance measurement shows a 38% decrease in the electrical resistivity, associated with the delocalization of the 4f-shell electrons, starting at 100 GPa up to a final pressure of 152 GPa. The continuous decrease in electrical resistivity is consistent with the observation of a gradual phase transition to α-U structure in this pressure range. The (1 1 1) diffraction peak of α-U structure first appears at 100 GPa and increases in intensity with increasing pressure to 152 GPa. This increase in intensity is attributed to an increasing volume fraction of α-U phase and an increase in structural y-parameter from 0.07 at 118 GPa to 0.095 at 152 GPa. In contrast to the abrupt pressure-induced f-electron transition seen in cerium and praseodymium, the continuous evolution of α-U structure and electrical resistivity in neodymium confirms the gradual nature of 4f delocalization process in this element.  相似文献   

11.
A new large volume multi-anvil system which employs six independently acting hydraulic rams with independent oil pressurization systems has been developed for high pressure and temperature experiments. The six 8 MN hydraulic rams approach at right angles inside a composite steel plate frame and can each advance a square faceted anvil of either hardened steel or tungsten carbide. The position of each anvil can be measured relative to the frame of the press to a precision of 0.1 μ m. The press is designed to perform both deformation experiments using cubic ceramic pressure media and experiments employing eight inner cubic anvils to compress an octahedral pressure medium. During compression, the position of each anvil relative to the press frame can be precisely measured and controlled independently, thus ensuring a high level of symmetry in the compressive stress environment. The highly cubic compressive regime provides an optimal environment for the use of inner sintered diamond cubic anvils, which can potentially obtain pressures above 50 GPa. The large loading capacity (24 MN) allows larger cubic pressure media to be used at higher pressures than conventional systems.  相似文献   

12.
The grinding and polishing of a fundamentally brittle material like glass to an utmost precision level for ultra-sophisticated applications ranging from mobile devices to aerospace as well as space shuttle components to biomedical appliances pose a big challenge today. Looking simplistically, the grinding and polishing processes are basically material removal by multiple scratching at a given speed. Unfortunately however, the role of the scratching speed in affecting the material removal mechanism in soda–lime–silica (SLS) glass is yet to be comprehensively understood. Therefore, the present work explores the surface and subsurface deformation mechanisms of SLS glass scratched under a normal load of 5 N at various speeds in the range of 100–1000 μm?s?1 with a diamond indenter of ~200 μm tip radius. The results show important roles of the time of contact, the tensile stress behind the indenter and the shear stress just beneath the indenter in governing the material removal mechanisms of the SLS glass.  相似文献   

13.
New diamond anvils with conical support are introduced. Compared to conventional anvils the new design offers superior alignment stability, larger aperture, and reduced cost owing to significantly smaller anvil diameters. Except for table and culet, all surfaces are precision ground on a lathe, which lowers cost compared to faceted anvils. The conical design allows for steel supports, which are significantly easier and cheaper to manufacture than tungsten carbide supports. Conical support also prevents seat damage upon diamond failure. An additional new feature of the anvils is the roughened outer portion of the culet, which increases friction between the anvils and the gasket. This increases the height to diameter ratio of the pressure cell and prevents bonding between gasket and diamond, which causes ring cracks during pressure release. This technique replaces complicated diamond coating procedures. The anvils have been extensively tested for culets ranging from 0.1 to 1 mm diameter up to megabar pressures. A new anvil shape with cup-shaped culets to further increase the cell volume and gasket stability is also introduced.  相似文献   

14.
The physical and mechanical properties of a C60 fullerene sample have been investigated under high pressure–high temperature conditions using a designer Diamond Anvil Cell. Electrical resistance measurements show evidence of C60 cage collapse at 20 GPa, which leads to the formation of an insulating phase at higher pressure. Energy dispersive X-ray diffraction (EDXD) data indicated that the characteristic fcc reflections gradually decrease in intensity and eventually disappear above 28 GPa. A C60 sample was laser-heated at a pressure of 35 GPa to a temperature of 1910±100 K and, subsequently, decompressed to ambient conditions. The photoluminescence spectra and the Raman spectrum of the pressure–temperature-treated sample were measured at a low temperature of 80 K. Raman peak at 1322.3 cm?1 with full-width half-maximum of 2.9 cm?1 was observed from the sample, which is attributed to the hexagonal diamond phase in the sample. The room temperature photoluminescence spectra showed a symmetric emission band centered in the red spectral range with a peak at 690 nm. The structural analysis of the pressure–temperature-processed C60 sample using EDXD method showed strong internal structure orientation and a phase close to hexagonal diamond. Mechanical properties such as hardness and Young’s modulus were measured by nanoindentation technique and the values were found to be 90±7 and 1215±50 GPa, respectively and these values are characteristic of sp3-bonded carbon materials.  相似文献   

15.
Ultra-high static pressures have been achieved in the laboratory using a two-stage micro-ball nanodiamond anvils as well as a two-stage micro-paired diamond anvils machined using a focused ion-beam system. The two-stage diamond anvils’ designs implemented thus far suffer from a limitation of one diamond anvil sliding past another anvil at extreme conditions. We describe a new method of fabricating two-stage diamond micro-anvils using a tungsten mask on a standard diamond anvil followed by microwave plasma chemical vapor deposition (CVD) homoepitaxial diamond growth. A prototype two-stage diamond anvil with 300?µm culet and with a CVD diamond second stage of 50?µm in diameter was fabricated. We have carried out preliminary high pressure X-ray diffraction studies on a sample of rare-earth metal lutetium sample with a copper pressure standard to 86?GPa. The micro-anvil grown by CVD remained intact during indentation of gasket as well as on decompression from the highest pressure of 86?GPa.  相似文献   

16.
We report the measurements of the three-dimensional pressure distribution in a sample of NaCl compressed to 6 GPa by apposed anvils with toroidal geometry. The results were obtained by energy-dispersive synchrotron X-ray diffraction using a V4-Paris-Edinburgh (PE) press with sintered diamond anvils and the incident beam directed along the thrust axis. This particular scattering geometry may be useful for other types of diffraction experiments using the PE press at synchrotron sources.  相似文献   

17.
In this paper, the feasibility of using explosion synthesized diamond nanoparticles with an average particle size (APS) of 3–5 nm with a concentration of 1 % by weight for improving lubrication and friction in elastohydrodynamic lubrication (EHL) was investigated. Owing to the orders of magnitude increase in the viscosity of the lubricant in the EHL contact zone, diamond nanoparticles in the lubricant polish the surfaces at the nanoscale which decreases the composite roughness of contacting surfaces. The reduced composite roughness results in an increased film thickness ratio which yields lower friction. In the numerical analysis, governing equations of lubricant flow in the full elastohydrodynamic lubrication were solved, and the shear stress distribution over the fluid film was calculated. Using an abrasion model and the shear stress distribution profile, the material removal by the nanofluid containing nanoparticles and the resultant surface roughness were determined. The numerical analysis showed that in full EHL regime, the nanolubricant can reduce the composite roughness of moving surfaces. Experimental results from prior studies which exhibited surface polishing by such nanolubricants in boundary, mixed, and full elastohydrodynamic lubrication were used for comparison to the numerical model.  相似文献   

18.
ABSTRACT

A simple modified Bridgman design for large volume pressure anvils usable in the Paris-Edinburgh (PE) press has been demonstrated at Oak Ridge National Laboratory Spallation Neutron Source. The design shows advantages over the toroidal anvils typically used in the PE press, mainly rapid compression/decompression rates, complete absence of blow-outs upon drastic phase transitions, simplified cooling, high reliability, and relative low loads (~40 tons) corresponding to relatively high pressures (~20?GPa). It also shows advantages over existing large-volume diamond cells as sample volumes of ~2–3?mm3 can be easily and rapidly synthesized. The anvils thus allow sample sizes sufficient for in situ neutron diffraction as well as rapid synthesis of adequate amounts of new materials for ex situ analysis via total neutron scattering and neutron spectroscopy.  相似文献   

19.
Since a long time, efforts have been made to improve the accuracy of pressure and temperature measurements in diamond anvil cell experiments performed in experimental petrology and high-pressure physics. Here, we report on the state-of-the-art of the research carried out during past few years with the diamond anvils carrying implanted electronic structures (‘intelligent’ anvils, iAnvils). The electronic structures are inserted a few microns below the diamond surface into the diamond lattice by high-energy implantation of boron. These structures can be used as pressure- and temperature-sensitive devices. Another useful application is the fabrication of micro-heaters integrated in the anvils. Pressure- and temperature-induced responses of the sensors (change of resistance) are quantified by low-current measurement equipment. Calibrations against pressure–temperature parameters are performed using well-known phase transitions or by using equation of state of pure substances. Results of in situ measurements performed on iAnvils under pressure and temperature are presented, together with calibration curves for pressure and temperature. Future experiments on in situ measurements of the conductivity dependence of the sensor structures are discussed.  相似文献   

20.
ABSTRACT

The phase transitions and equation of state measurements were carried out on rare earth metal Holmium (Ho) to 282?GPa using toroidal diamond anvils thereby doubling the pressure range to which it has been studied previously. The first set of experiment employed standard beveled diamond anvils utilizing copper as an x-ray pressure standard to 217?GPa. The second set of experiment employed toroidal diamond anvils utilizing platinum as an x-ray pressure standard to 282?GPa. The recently proposed 16-atom orthorhombic structure (oF16) appeared to be stable between 103 and 282?GPa. The scaled axial ratio (c/a) shows a narrow range of variation of 1.58?±?0.05 for the five known crystalline phases of Ho to 282?GPa. The experimental equation of state of Ho is presented up to a threefold volume compression V/Vo?=?0.322.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号