首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the direct analysis of liquid samples. Several interesting results were found. First, in contrast to the previous DESI analysis of dried solid samples that was limited to proteins with MW ≤25 kDa (Anal. Chem. 2007, 79, 3514), bovine serum albumin (BSA, 66 kDa) was successfully ionized from solutions by DESI with observation of corresponding multiply charged ions. Second, direct DESI analysis of protein tryptic digest solutions without chromatographic separation, sample clean-up, and the sample drying step was demonstrated, providing reasonably good sequence coverage of 52% to 97%. Third, direct analysis of biofluids such as an undiluted urine sample without sample pretreatment is possible, emphasizing the high tolerance of DESI with salt. These results suggest that a charged droplet pick-up mechanism is responsible for desorption and ionization of liquid samples by DESI. Also, unlike in electrospray ionization (ESI), inhibition of electrochemical reduction in the negative ion mode was observed for liquid sample DESI. In addition, reactive DESI can be performed with ion/ion reactions of Zn(II) complexes for the selective binding of phosphoserine in the presence of serine. DESI experiment can also be carried out directly to liquid samples flowing out of a pumped syringe needle tip, allowing rapid analysis. Furthermore, on-line coupling of electrochemical cell with DESI-MS was demonstrated, in which perylene radical cations generated in the cell were successfully transferred to the gas-phase for MS detection by DESI. This study extended the scope of DESI-MS applications, which could have potentials in bioanalytical and forensic analysis.  相似文献   

2.
A new mode of operation for desorption electrospray ionization (DESI) analysis of liquids or solid residues from evaporated solvents is presented. Unlike traditional DESI, the electrospray is not deflected off of a surface but instead is transmitted through a sampling mesh at a 0° angle between the electrospray tip, sample mesh, and capillary inlet of a mass spectrometer. In this configuration, deposited samples can be analyzed rapidly without rigorous optimization of spray distances or angles and without the preparation time associated with solvent evaporation. The new transmission mode desorption electrospray ionization (TM-DESI) technique is not applicable to bulk materials, but instead is a method designed to simplify the sample preparation process for liquid samples and sample extracts. The technique can reduce analysis time to seconds while consuming only microliters of sample. The results presented summarize the optimization of the technique, highlight key figures of merit for several model compounds, and illustrate potential applications to high throughput screening of liquid mixtures in both extraction solvents and biological matrices.  相似文献   

3.
4.
江玮  喻钢 《分析测试学报》2012,31(4):430-435
自建了简易的电喷雾解吸电离源(DESI),优化了DESI源喷口的位置和角度,并将其用于常见多肽和蛋白质的分析。多肽和小质量蛋白质(<20 kDa)可以容易地从表面解吸电离,生成清晰的质谱。而牛血清白蛋白(66.4 kDa)不能产生清晰的多电荷分布的质谱,说明当前DESI源的设计可能存在一个电离的分子量上限。通过比较不同的实验条件并对比ESI-MS,发现溶剂分子的挥发过程对电荷分布以及峰宽均有显著影响,可能是由于ESI更软引起。载样表面的性质对DESI-MS的信号强度有较大影响。金表面的自组装单分子膜(SAM)相对于纯金表面有较好的绝缘性,并有助于产生较强信号,说明来自表面的电子转移(电中和)是电喷雾解吸电离过程中的一个重要因素。该文的研究有助于对DESI-MS的实验条件和载样表面的选择,同时增进了对电喷雾解吸电离机理的了解。  相似文献   

5.
A new method to analyze free amino acids using desorption electrospray ionization (DESI) has been implemented. The method is based on the neutral loss mode determination of underivatized amino acids using a tandem quadrupole mass spectrometer equipped with an unmodified atmospheric interface. Qualitative and quantitative optimization of DESI parameters, including ESI voltage, solvent flow rate, angle of collection and incidence, gas flow and temperatures, was performed for amino acids detection. The parameters for DESI analysis were evaluated using a mixture of valine, leucine, methionine, phenylalanine and tyrosine standards. A few microliters of this mixture were deposited on a slide, dried and analyzed at a flow rate of 2 microL/min. The optimal ionization response was obtained using laboratory glass slides and an equivalent solution of water/methanol doped with 2% of formic acid. The method specificity was evaluated by comparing product ion spectra and neutral loss analysis of amino acids obtained either by DESI or by electrospray ionization flow injection analysis (ESI-FIA). To evaluate the quantitative response on amino acids analyzed by DESI, calibration curves were performed on amino acid standard solutions spiked with a fixed amount of labelled amino acids. The method was also employed to analyze free amino acids from blood spots, after a rapid solvent extraction without other sample pretreatment, from positive and negative subjects. The method enables one to analyze biological samples and to discriminate healthy subjects from patients affected by inherited metabolic diseases. The intrinsic high-throughput analysis of DESI represents an opportunity, because of its potential application in clinical chemistry, for the expanded screening of some inborn errors of metabolism.  相似文献   

6.
A novel method is reported for rapid protein identification by the analysis of tryptic peptides using desorption electrospray ionisation (DESI) coupled with hyphenated ion mobility spectrometry and quadrupole time-of-flight mass spectrometry (IMS/Q-ToF-MS). Confident protein identification is demonstrated for the analysis of tryptically digested bovine serum albumin (BSA), with no sample pre-treatment or clean-up. Electrophoretic ion mobility separation of ions generated by DESI allowed examination of charge-state and mobility distributions for tryptic peptide mixtures. Selective interrogation of singly charged ions allowed isobaric peptide responses to be distinguished, along with a reduction in spectral noise. The mobility-selected singly charged peptide responses were presented as a pseudo-peptide mass fingerprint (p-PMF) for protein database searching. Comparative data are shown for electrospray ionisation (ESI) of the BSA digest, without sample clean-up, from which confident protein identification could not be made. Implications for the robustness of the DESI method, together with potential insights into mechanisms for DESI of proteolytic digests, are discussed.  相似文献   

7.
A desorption electrospray ionization (DESI) source has been coupled to an ion mobility time-of-flight mass spectrometer for the analysis of proteins. Analysis of solid-phase horse heart cytochrome c and chicken egg white lysozyme proteins with different DESI solvents and conditions shows similar mass spectra and charge state distributions to those formed when using electrospray to analyze these proteins in solution. The ion mobility data show evidence for compact ion structures [when the surface is exposed to a spray that favors retention of "nativelike" structures (50:50 water:methanol)] or elongated structures [when the surface is exposed to a spray that favors "denatured" structures (49:49:2 water:methanol:acetic acid)]. The results suggest that the DESI experiment is somewhat gentler than ESI and under appropriate conditions, it is possible to preserve structural information throughout the DESI process. Mechanisms that are consistent with these results are discussed.  相似文献   

8.
The ionization mechanism of negative ion-direct analysis in real time (NI-DART) has been investigated using over 42 compounds, including fullerenes, perfluorocarbons (PFC), organic explosives, phenols, pentafluorobenzyl (PFB) derivatized phenols, anilines, and carboxylic acids, which were previously studied by negative ion-atmospheric pressure photoionization (NI-APPI). NI-DART generated ionization products similar to NI-APPI, which led to four ionization mechanisms, including electron capture (EC), dissociative EC, proton transfer, and anion attachment. These four ionization mechanisms make both NI-DART and NI-APPI capable of ionizing a wider range of compounds than negative ion-atmospheric pressure chemical ionization (APCI) or negative ion-electrospray ionization (ESI). As the operation of NI-DART is much easier than that of NI-APPI and the gas-phase ion chemistry of NI-DART is more easily manipulated than that of NI-APPI, NI-DART can be therefore used to study in detail the ionization mechanism of LC/NI-APPI-MS, which would be a powerful methodology for the quantification of low-polarity compounds. Herein, one such application has been further demonstrated in the detection and identification of background ions from LC solvents and APPI dopants, including water, acetonitrile, chloroform, methylene chloride, methanol, 2-propanol, hexanes, heptane, cyclohexane, acetone, tetrahydrofuran (THF), 1,4-dioxane, toluene, and anisole. Possible reaction pathways leading to the formation of these background ions were further inferred. One of the conclusions from these experiments is that THF and 1,4-dioxane are inappropriate to be used as solvents and/or dopants for LC/NI-APPI-MS due to their high reactivity with source basic ions, leading to many reactant ions in the background.  相似文献   

9.
Desorption electrospray ionization mass spectrometry (DESI‐MS) requires little to no sample preparation and has been successfully applied to the study of biologically significant macromolecules such as proteins. However, DESI‐MS and other ambient methods that use spray desorption to process samples during ionization appear limited to smaller proteins with molecular masses of 25 kDa or less, and a decreasing instrumental response with increasing protein size has often been reported. It has been proposed that this limit results from the inability of some proteins to easily desorb from the surface during DESI sampling. The present study investigates the apparent mass dependence of the instrumental response observed during the DESI‐MS analysis of proteins using spray desorption collection and reflective electrospray ionization. Proteins, as large as 66 kDa, are shown to be quantitatively removed from surfaces by using spray desorption collection. However, incomplete dissolution and the formation of protein–protein and protein–contaminant clusters appear to be responsible for the mass‐dependent loss in sensitivity for protein analysis. Alternative ambient mass spectrometry approaches that address some of the problems encountered by spray desorption techniques for protein analysis are also discussed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
During direct liquid introduction (DLI) liquid chromatography-mass spectrometry (LC-MS), the detectability of acetone is shown to be predictable, based on consideration of the gas-phase acidities and basicities of solvents methanol and acetonitrile and modifiers formic acid and ammonium formate. Consequently, ion formation in DLI LC-MS resembles gas-phase chemical ionization processes; since the order of acidities is altered in solution, solution ionization must be much less important than gas-phase. Ion populations could be predicted on the basis of gas-phase proton affinities and acidities: acetone could be detected in all solvent mixture by positive ions, but it was not readily detected by negative ions when acid was also present. In solvents without additives it was always detected.  相似文献   

11.
Novel sampling and detection methods using desorption electrospray ionization (DESI) are examined in the detection of explosives (RDX, TNT, HMX, and TNB) and agricultural chemicals (atrazine, alachlor and acetochlor) from aqueous matrices and authentic contaminated groundwater samples. DESI allows analysis of solid and liquid compounds directly from surfaces of interest with little or no sample preparation. Significant savings in analysis time and sample preparation are realized. The methods investigated here include (i) immediate analysis of filter paper wetted with contaminated water samples without further sample preparation, (ii) rapid liquid-liquid extraction (LLE), and (iii) analyte extraction from contaminated groundwater samples on-site using solid-phase extraction (SPE) membranes, followed by direct DESI analysis of the membrane. The wetted filter paper experiment demonstrates the maximum sample throughput for DESI analysis of aqueous matrices but has inadequate sensitivity for some of these analytes. Both the LLE and the SPE methods have adequate sensitivity. The resulting SPE membranes and/or small volume solvent extracts produced in these experiments are readily transported to off-site facilities for direct analysis by DESI. This realizes a significant reduction in the costs of sample shipping compared with those for typical liter-sized samples of groundwater. Total analysis times for these preliminary DESI analyses are comparable with or shorter than those for GC/MS and limits of detection approach environmental action levels for these compounds while maintaining a modest relative standard deviation. Tandem mass spectrometric data is used to provide additional specificity as needed.  相似文献   

12.
Internal energy distributions in desorption electrospray ionization (DESI)   总被引:3,自引:2,他引:1  
The internal energy distributions of typical ions generated by desorption electrospray ionization (DESI) were measured using the "survival yield" method, and compared with corresponding data for electrospray ionization (ESI) and electrosonic spray ionization (ESSI). The results show that the three ionization methods produce populations of ions having internal energy distributions of similar shapes and mean values (1.7-1.9 eV) suggesting similar phenomena, at least in the later stages of the process leading from solvated droplets to gas-phase ions. These data on energetics are consistent with the view that DESI involves "droplet pick-up" (liquid-liquid extraction) followed by ESI-like desolvation and gas-phase ion formation. The effects of various experimental parameters on the degree of fragmentation of p-methoxy-benzylpyridinium ions were compared between DESI and ESSI. The results show similar trends in the survival yields as a function of the nebulizing gas pressure, solvent flow rate, and distance from the sprayer tip to the MS inlet. These observations are consistent with the mechanism noted above and they also enable the user to exercise control over the energetics of the DESI ionization process, through manipulation of external and internal ion source parameters.  相似文献   

13.
Spray solvent doped with silver ions increases the ease of olefin detection by desorption electrospray ionization (DESI). Characteristic silver adducts were generated in up to 50 times greater abundance when compared to conventional DESI spray solvents for the biologically significant olefin, arachidonic acid, in the positive ion mode. In the analysis of 26 lipids, silver adduct formation was highly favorable for fatty acids, fatty acid esters and prostaglandins but not applicable to some other classes (e.g., polar lipids such as ceramide and its derivative cerebroside sulfate). An investigation exploring competitive Ag+ cationization with a mixture of components demonstrated that polyunsaturated compounds form Ag+ adducts most readily. Silver cationization allowed the distinction between three sets of isomers in the course of multiple-stage collision-induced dissociation, so providing insight into the location of the olefin bonds. A silver ion-doped solvent was used in DESI imaging of normal and tumor canine bladder tissue sections. The Ag+ fatty acid adducts permitted post facto differentiation between the normal and tumor regions. In addition, silver adduct formation in the course of DESI imaging of tissue sections revealed the presence of triacylglycerides, a class of compounds not previously identified through DESI imaging. A simple silver nitrate spray solvent has the potential to further improve DESI analysis of unsaturated biomolecules and other molecules containing π-bonds through selective silver cationization.  相似文献   

14.
In this paper, we describe a novel technique—ultrasonication-assisted spray ionization (UASI)—for the generation of singly charged and multiply charged gas-phase ions of biomolecules (e.g., amino acids, peptides, and proteins) from solution; this method employs a low-frequency ultrasonicator (ca. 40 kHz) in place of the high electric field required for electrospray ionization. When a capillary inlet is immersed into a sample solution within a vial subjected to ultrasonication, the solution is continually directed to the capillary outlet as a result of ultrasonication-assisted capillary action; an ultrasonic spray of the sample solution is emitted at the outlet of the tapered capillary, leading to the ready generation of gas-phase ions. Using an ion trap mass spectrometer, we found that singly charged amino acid and multiply charged peptides/proteins ions were generated through this single-step operation, which is both straightforward and extremely simple to perform. The setup is uncomplicated: only a low-frequency ultrasonicator and a tapered capillary are required to perform UASI. The mass spectra of the multiply charged peptides and proteins obtained from sample solutions subjected to UASI resemble those observed in ESI mass spectra.  相似文献   

15.
In this article, the effect of spray solvent on the analysis of selected lipids including fatty acids, fat‐soluble vitamins, triacylglycerols, steroids, phospholipids, and sphingolipids has been studied by two different ambient mass spectrometry (MS) methods, desorption electrospray ionization‐MS (DESI‐MS) and desorption atmospheric pressure photoionization‐MS (DAPPI‐MS). The ionization of the lipids with DESI and DAPPI was strongly dependent on the spray solvent. In most cases, the lipids were detected as protonated or deprotonated molecules; however, other ions were also formed, such as adduct ions (in DESI), [M‐H]+ ions (in DESI and DAPPI), radical ions (in DAPPI), and abundant oxidation products (in DESI and DAPPI). DAPPI provided efficient desorption and ionization for neutral and less polar as well as for ionic lipids but caused extensive fragmentation for larger and more labile compounds because of a thermal desorption process. DESI was more suitable for the analysis of the large and labile lipids, but the ionization efficiency for less polar lipids was poor. Both methods were successfully applied to the direct analysis of lipids from pharmaceutical and food products. Although DESI and DAPPI provide efficient analysis of lipids, the multiple and largely unpredictable ionization reactions may set challenges for routine lipid analysis with these methods. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
Investigations have been initiated to develop a sufficiently good separation of both major and minor organic acids and inorganic anions present in grape musts using a Dionex As11 column, a sodium hydroxide gradient elution and a suppressed conductivity detection. Separation was complicated in aqueous mobile phase by co-elutions and selectivity was optimized using organic modifiers that alter ion-exchange selectivity for hydrophobic ions. In this study, the influence of three different solvents (methanol, ethanol and acetonitrile) on the efficiency of column was compared. The best separation of all ions in a synthetic solution was achieved with an eluent containing 13% (v/v) methanol and 13% (v/v) ethanol in water, the run during only 20 min. This method was next applied to grape juices with success and has shown sensitivity and reproducibility. Moreover, sample preparation was a simple 20-fold dilution with 0.45 microm filtration and direct injection without prior sample clean-up.  相似文献   

17.
The exposure of electrospray droplets to vapors of deuterating reagents during droplet desolvation in the interface of a mass spectrometer results in hydrogen/deuterium exchange (HDX) on the sub‐millisecond time scale. Deuterated water is used to label ubiquitin and cytochrome c with minimal effect on the observed charge state distribution (CSD), suggesting that the protein conformation is not being altered. However, the introduction of deuterated versions of various acids (e.g., CD3COOD and DCl) and bases (ND3) induces unfolding or refolding of the protein while also labeling these newly formed conformations. The extent of HDX within a protein CSD associated with a particular conformation is essentially constant, whereas the extent of HDX can differ significantly for CSDs associated with different conformations from the same protein. In some cases, multiple HDX distributions can be observed within a given charge state (as is demonstrated with cytochrome c) suggesting that the extent of HDX and CSDs share a degree of complementarity in their sensitivities for protein conformation. The CSD is established late in the evolution of ions in electrospray whereas the HDX process presumably takes place in the bulk of the droplet throughout the electrospray process. Back exchange is also performed in which proteins are prepared in deuterated solvents prior to ionization and exposed to undeuterated vapors to exchange deuteriums for hydrogens. The degree of deuterium uptake is easily controlled by varying the identity and partial pressure of the reagent introduced into the interface. Since the exchange occurs on the sub‐millisecond time scale, the use of deuterated acids or bases allows for transient species to be generated and labeled for subsequent mass analysis. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A new prestructured target plate for matrix-assisted laser desorption/ionization (MALDI) was developed specifically for hydrophobic integral membrane proteins. This sample support contains predefined concentrating sample spots with a focusing effect on droplets with a high content of hexafluoroisopropanol (HFIP). This fluorinated organic solvent is advantageous for solubilizing hydrophobic proteins that are not soluble in water or the organic solvents normally used in sample preparation protocols for MALDI-MS. The prestructured plate was constructed by coating a regular steel plate with a thin layer of a silicone polymer, leaving sample spots of bare steel. Fabrication of the concentrating silicone structure was fast and very straightforward, without expensive or complicated equipment. Removing the layer, and thus regenerating the steel plate, was done by a simple washing procedure. The application and cleaning procedure are not constrained by a particular design of sample support or to any specific brand of mass spectrometer. When using the prestructured MALDI plate with HFIP as the sample solvent for 17 pmol of a cyanogen bromide digest of the highly hydrophobic membrane protein bacteriorhodopsin, an improved focusing effect and an increase of more than five-fold in average sensitivity were observed, compared with a regular steel target. Experimental results show a two-fold increase in average sensitivity when the new prestructured target plate was used, compared with a commercially available concentrating support.  相似文献   

19.
Ambient mass spectrometry, pioneered with desorption electrospray ionization (DESI) technique, is of increasing interest in recent years. In this study, a corona discharge ionization source is adapted for direct surface desorption chemical ionization of compounds on various surfaces at atmospheric pressure. Ambient air, with about 60% relative humidity, is used as a reagent to generate primary ions such as H(3)O(+), which is then directed to impact the sample surface for desorption and ionization. Under experimental conditions, protonated or deprotonated molecules of analytes present on various samples are observed using positive or negative corona discharge. Fast detection of trace amounts of analytes present in pharmaceutical preparations, viz foods, skins and clothes has been demonstrated without any sample pretreatment. Taking the advantage of the gasless setup, powder samples such as amino acids and mixtures of pharmaceutical preparations are rapidly analyzed. Impurities such as sudan dyes in tomato sauce are detected semiquantitatively. Molecular markers (e.g. putrescine) for meat spoilage are successfully identified from an artificially spoiled fish sample. Chemical warfare agent stimulants, explosives and herbicides are directly detected from the skin samples and clothing exposed to these compounds. This provides a detection limit of sub-pg (S/N > or = 3) range in MS2. Metabolites and consumed chemicals such as glucose are detected successfully from human skins. Conclusively, surface desorption atmospheric pressure chemical ionization (DAPCI) mass spectrometry, without toxic chemical contamination, detects various compounds in complex matrices, showing promising applications for analyses of human related samples.  相似文献   

20.
Electrospray-ionization (ESI) mass spectrometry is used to monitor higher order structural changes of polypeptides induced by alteration of the pH or organic solvent composition in the protein solution environment. A bimodal charge-state distribution is observed in the ESI mass spectrum of ubiquitin (relative molecular mass 8565) in solutions containing small amounts (less than 20%) of organic solvents. The distribution of peaks at high m/z (low-charge state) is found to represent the protein in its native, globular state; the higher-charge-state distribution is characteristic for a more extended conformation. Addition of methanol denaturant in excess of 40% v/v is needed to eliminate the low-charge-state distribution completely. Lesser amounts of acetonitrile, acetone, or isopropanol (approximately 20%) are required to denature the ubiquitin protein. Other proteins showing conformational effects in their ESI mass spectra are also illustrated. While the ESI spectra are related to solution phase structure, ESI-tandem mass spectrometry of multiply charged molecular ions of different conformation is suggested as a probe of gas-phase protein three-dimensional structure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号