首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Fluorescence cross-correlation spectroscopy (FCCS) is a highly sensitive fluorescence technique with distinct advantages in many bioanalytical applications involving interaction and binding of multiple components. Due to the use of multiple beams, bulk optical FCCS setups require delicate and complex alignment procedures. We demonstrate the first implementation of dual-color FCCS on a planar, integrated optofluidic chip based on liquid-core waveguides that can guide liquid and light simultaneously. In this configuration, the excitation beams are delivered in predefined locations and automatically aligned within the excitation waveguides. We implement two canonical applications of FCCS in the optofluidic lab-on-chip environment: particle colocalization and binding/dissociation dynamics. Colocalization is demonstrated in the detection and discrimination of single-color and double-color fluorescently labeled nanobeads. FCCS in combination with fluorescence resonance energy transfer (FRET) is used to detect the denaturation process of double-stranded DNA at nanomolar concentration.  相似文献   

2.
Waveguide trapping has emerged as a useful technique for parallel and planar transport of particles and biological cells and can be integrated with lab-on-a-chip applications. However, particles trapped on waveguides are continuously propelled forward along the surface of the waveguide. This limits the practical usability of the waveguide trapping technique with other functions (e.g. analysis, imaging) that require particles to be stationary during diagnosis. In this paper, an optical waveguide loop with an intentional gap at the centre is proposed to hold propelled particles and cells. The waveguide acts as a conveyor belt to transport and deliver the particles/cells towards the gap. At the gap, the diverging light fields hold the particles at a fixed position. The proposed waveguide design is numerically studied and experimentally implemented. The optical forces on the particle at the gap are calculated using the finite element method. Experimentally, the method is used to transport and trap micro-particles and red blood cells at the gap with varying separations. The waveguides are only 180 nm thick and thus could be integrated with other functions on the chip, e.g. microfluidics or optical detection, to make an on-chip system for single cell analysis and to study the interaction between cells.  相似文献   

3.
We present the first integration of fluidically tunable filters with a separate particle detection channel on a single planar, optofluidic chip. Two optically connected, but fluidically isolated liquid-core antiresonant reflecting optical waveguide (ARROW) segments serve as analyte and spectral filter sections, respectively. Ultrasensitive detection of fluorescent nanobeads with high signal-to-noise ratio provided by a fluidically tuned excitation notch filter is demonstrated. In addition, reconfigurable filter response is demonstrated using both core index tuning and bulk liquid tuning. Notch filters with 43 dB rejection ratio and a record 90 nm tuning range are implemented by using different mixtures of ethylene glycol and water in the filter section. Moreover, absorber dyes and liquids with pH-dependent transmission in the filter channel provide additional spectral control independent of the waveguide response. Using both core index and pH control, independent filter tuning at multiple wavelengths is demonstrated for the first time. This extensive on-chip control over spectral filtering as one of the fundamental components of optical particle detection techniques offers significant advantages in terms of compactness, cost, and simplicity, and opens new opportunities for waveguide-based optofluidic analysis systems.  相似文献   

4.
Quantum dot thermal imaging has been used to analyse the chromatic dependence of laser-induced thermal effects inside optofluidic devices with monolithically integrated near-infrared waveguides. We demonstrate how microchannel optical local heating plays an important role, which cannot be disregarded within the context of on-chip optical cell manipulation. We also report on the thermal imaging of locally illuminated microchannels when filled with nano-heating particles such as carbon nanotubes.  相似文献   

5.
Y Hanada  K Sugioka  K Midorikawa 《Lab on a chip》2012,12(19):3688-3693
The demand for increased sensitivity in the concentration analysis of biochemical liquids is a crucial issue in the development of lab on a chip and optofluidic devices. We propose a new design for optofluidic devices for performing highly sensitive biochemical liquid assays. This design consists of a microfluidic channel whose internal walls are coated with a polymer and an optical waveguide embedded in photostructurable glass. The microfluidic channel is first formed by three-dimensional femtosecond laser micromachining. The internal walls of the channel are then coated by the dipping method with a polymer that has a lower refractive index than water. Subsequently, the optical waveguide is integrated with the microfluidic channel. The polymer coating on the internal walls permits the probe light, which is introduced by the optical waveguide, to propagate along the inside of the microfluidic channel. This results in a sufficiently long interaction length between the probe light and a liquid sample in the channel and thus significantly improves the sensitivity of absorption measurements. Using the fabricated optofluidic chips, we analyzed protein in bovine serum albumin to concentrations down to 7.5 mM as well as 200 nM glucose-D.  相似文献   

6.
Lee KS  Lee HL  Ram RJ 《Lab on a chip》2007,7(11):1539-1545
A polymer optical backplane capable of generic luminescence detection within microfluidic chips is demonstrated using large core polymer waveguides and vertical couplers. The waveguides are fabricated through a new process combining mechanical machining and vapor polishing with elastomer microtransfer molding. A backplane approach enables general optical integration with planar array microfluidics since optical backplanes can be independently designed but still integrated with planar fluidic circuits. Fabricated large core waveguides exhibit a loss of 0.1 dB cm(-1) at 626 nm, a measured numerical aperture of 0.50, and a collection efficiency of 2.86% in an n = 1.459 medium, comparable to a 0.50 NA microscope objective. In addition to vertical couplers for out-of-plane collection and excitation, polymer waveguides are doped with organic dyes to provide wavelength selective filtering within waveguides, further improving optical device integration. With large core low loss waveguides, luminescence collection is improved and measurements can be performed with simple LEDs and photodetectors. Fluorescein detection via fluorescence intensity with a limit of detection (3sigma) of 200 nM in a 1 microL volume is demonstrated. Phosphorescence lifetime based oxygen detection in water in an oxygen controllable microbial cell culture chip with a limit of detection (3sigma) of 0.08% or 35 ppb is also demonstrated utilizing the waveguide backplane. Single waveguide luminescence collection performance is equivalent to a back collection geometry fiber bundle consisting of nine 500 microm diameter collection fibers.  相似文献   

7.
Femtosecond laser processing for optofluidic fabrication   总被引:1,自引:0,他引:1  
K Sugioka  Y Cheng 《Lab on a chip》2012,12(19):3576-3589
Femtosecond laser direct writing is a promising technique for fabricating optofluidic devices since it can modify the interior of glass in a spatially selective manner through multiphoton absorption. The chemical properties of laser-irradiated regions in glass are modified allowing them to be selectively etched by subsequent wet etching using aqueous solutions of etchants such as hydrofluoric (HF) acid. This technique can be used to directly form three-dimensional microfluidic systems. The two-step process can also be used to fabricate free-space optical components such as micromirrors and microlenses inside glass. In addition, femtosecond laser direct writing can alter the optical properties of a substrate to create a wide range of micro-optical components inside glass, including optical waveguides, Mach-Zehnder interferometers, and optical attenuators. The unique ability of femtosecond laser direct writing to simultaneously alter the chemical and optical properties of glass opens up a new avenue for fabricating a variety of optofluidic microchips for biological analysis. Optofluidic microchips fabricated using femtosecond lasers have been used to determine the functions of living microorganisms, determine the concentrations of liquid samples, detect and manipulate single cells, and rapidly screen algae populations. This paper presents a comprehensive review of optofluidic devices for biological analysis fabricated by femtosecond laser processing.  相似文献   

8.
Nanomanipulation using near field photonics   总被引:1,自引:0,他引:1  
Erickson D  Serey X  Chen YF  Mandal S 《Lab on a chip》2011,11(6):995-1009
In this article we review the use of near-field photonics for trapping, transport and handling of nanomaterials. While the advantages of traditional optical tweezing are well known at the microscale, direct application of these techniques to the handling of nanoscale materials has proven difficult due to unfavourable scaling of the fundamental physics. Recently a number of research groups have demonstrated how the evanescent fields surrounding photonic structures like photonic waveguides, optical resonators, and plasmonic nanoparticles can be used to greatly enhance optical forces. Here, we introduce some of the most common implementations of these techniques, focusing on those which have relevance to microfluidic or optofluidic applications. Since the field is still relatively nascent, we spend much of the article laying out the fundamental and practical advantages that near field optical manipulation offers over both traditional optical tweezing and other particle handling techniques. In addition we highlight three application areas where these techniques namely could be of interest to the lab-on-a-chip community, namely: single molecule analysis, nanoassembly, and optical chromatography.  相似文献   

9.
The fabrication of tubular rolled-up optofluidic ring resonators (RU-OFRRs) based on glass (SiO(2)) material with high quality factors is reported. A novel methodology combining lab-on-a-chip fabrication methods and rolled-up nanotech is presented for the fabrication of fully integrated tubular optofluidic sensors. The microfluidic integration of several RU-OFRRs on one chip is solved by enclosing the microtubes with a patterned robust SU-8 polymeric matrix. A viewport on each microtube enables exact excitation and monitoring of whispering gallery modes with a photoluminescence spectroscopy system under constant ambient conditions, while exchanging the content of the RU-OFRR with liquids of different refractive indices. The refractrometric sensor capabilities are investigated regarding signal stability, sensitivity and reliability. The sensitivity of the integrated RU-OFRR, which is the response of the modes to the change in refractive index of the liquid, is up to 880 nm/refractive index units (RIU).  相似文献   

10.
Optofluidic variable-focus lenses for light manipulation   总被引:2,自引:0,他引:2  
YC Seow  SP Lim  HP Lee 《Lab on a chip》2012,12(19):3810-3815
This paper presents a planar optofluidic lens for light manipulation utilizing a combination of optofluidic biconvex lens with micromixer. Three light manipulation techniques including tunable optical diverging, collimating and focusing are realized by altering the refractive index of the optofluidic variable-focus lenses formed by solid polydimethylsiloxane (PDMS) walls and tunable liquid lens body. The optical power from the laser input can be increased or decreased with the tuning of the variable-focus lenses' refractive indexes. The optical power adjustment capabilities are demonstrated and characterized. The combinations of benefits of all lens' optical manipulation capabilities, greater mechanical stability, significant increase of optofluidic device's life time and seamless integration with other lab-on-a-chip functionalities provide a promising and versatile optofluidic compartment to integrate with lab-on-a-chip excitation and sensing applications. Optofluidic lens-including system for tunable fluorescence sensing is demonstrated showing 186% increase in detected fluorescence intensity.  相似文献   

11.
Fei P  Chen Z  Men Y  Li A  Shen Y  Huang Y 《Lab on a chip》2012,12(19):3700-3706
We developed a simple method to construct liquid-core/PDMS-cladding optical waveguides through pressurized filling of dead-ended micro-channels with optical fluids. The waveguides are in the same layer as microfluidic channels which greatly simplifies device fabrication. With proper contrast between the refractive index of the core and cladding, the transmission loss of the waveguides is less than 5 dB cm(-1). We also developed a method to create flat and optically clear surfaces on the sides of PDMS devices in order to couple light between free-space and the waveguides embedded inside the chip. With these newly developed techniques, we make a compact flow cytometer and demonstrate the fluorescence counting of single cells at a rate of up to ~50 cell s(-1) and total sample requirement of a few microlitres. This method of making liquid-core optical waveguides and flat surfaces has great potential to be integrated into many PDMS-based microsystems.  相似文献   

12.
Evanescent coupling is used to couple light from an organic Lambertian emitter into a single‐mode planar waveguide. A polymer light emitting diode pumps a photoluminescent layer located directly on top of the waveguide. At the out‐coupling grating stage, a fully organic mini‐spectrometer compatible with monolithical integration on optical bio chips has been developed. It consists of a single‐mode waveguide with integrated diffraction grating and a dense array of polymer photodiodes as sensing element. An overall spectral resolution of down to 5 nm has been achieved with the integrated optoelectronic system. As a proof of principle the fully organic optical device has been used in combination with a fluidic system to demonstrate an absorption‐based bio‐test with mouse immunoglobulin G. In a further step towards low‐cost and disposable lab‐on‐chip biosensors, the mentioned organic building blocks have been combined with a surface plasmon stack integrated directly onto the single mode waveguide. © 2010 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys, 2010  相似文献   

13.
L Pang  HM Chen  LM Freeman  Y Fainman 《Lab on a chip》2012,12(19):3543-3551
Optofluidics integrates the fields of photonics and microfluidics, providing new freedom to both fields and permitting the realization of optical and fluidic property manipulations at the chip scale. Optofluidics was formed only after many breakthroughs in microfluidics, as understanding of fluid behaviour at the micron level enabled researchers to combine the advantages of optics and fluids. This review describes the progress of optofluidics from a photonics perspective, highlighting various optofluidic aspects ranging from the device's property manipulation to an interactive integration between optics and fluids. First, we describe photonic elements based on the functionalities that enable fluid manipulation. We then discuss the applications of optofluidic biodetection with an emphasis on nanosensing. Next, we discuss the progress of optofluidic lenses with an emphasis on its various architectures, and finally we conceptualize on where the field may lead.  相似文献   

14.
The fabrication and performance of an electrophoretic separation chip with integrated optical waveguides for absorption detection is presented. The device was fabricated on a silicon substrate by standard microfabrication techniques with the use of two photolithographic mask steps. The waveguides on the device were connected to optical fibers, which enabled alignment free operation due to the absence of free-space optics. A 750 microm long U-shaped detection cell was used to facilitate longitudinal absorption detection. To minimize geometrically induced band broadening at the turn in the U-cell, tapering of the separation channel from a width of 120 down to 30 microm was employed. Electrical insulation was achieved by a 13 microm thermally grown silicon dioxide between the silicon substrate and the channels. The breakdown voltage during operation of the chip was measured to 10.6 kV. A separation of 3.2 microM rhodamine 110, 8 microM 2,7-dichlorofluorescein, 10 microM fluorescein and 18 microM 5-carboxyfluorescein was demonstrated on the device using the detection cell for absorption measurements at 488 nm.  相似文献   

15.
Song W  Psaltis D 《Lab on a chip》2011,11(14):2397-2402
We presented a pneumatically tunable 2 × 2 optofluidic switch for on-chip light routing that was controlled by compressed air. The device was fabricated with an optically clear elastomer-polydimethylsiloxane (PDMS)-by soft-lithography. The optical switching is realized with a tunable air-gap mirror by which the light is deflected due to total internal reflection in the bypass state. When the device is subjected to high pressure, the air gap collapses and hence the light will be switched to the crossover state. The device had a switching speed of more than 5 Hz and an extinction ratio of 8 dB. This switch can be readily integrated with other microfluidic circuits. We demonstrated a simple reconfigurable optical waveguide circuit for dual-channel microfluidic spectroscopy measurement on a chip.  相似文献   

16.
A new fabrication procedure for integration of ultraviolet transparent pure-silica planar waveguides, fiber couplers and high-aspect ratio submicrometer channels is presented. Only a single photolithographic mask step is required. The channels are 80-90 microm deep and the width can be reduced to about 0.5 microm, corresponding to a height-to-width ratio of more than 150. The core of the waveguides consists of pure silicon dioxide, which is favorable over doped silica, due to the absence of absorption centers associated with the dopants. This furthermore improves the long-term stability of the waveguides, because of an increased radiation resistance of the glass. The propagation loss decreases from 1.0 dB/cm at 200 nm to 0.2 dB/cm at 800 nm, which, to our knowledge, is the lowest propagation loss reported for integrated planar waveguides in the ultraviolet wavelength region to date. The effective optical path length is 1.2 mm for an absorbance cell with a nominal length of 1.0 mm, indicating effective suppression of stray light. The limit of detection for paracetamol when present in the entire channel network was determined to 3 microg/mL. Finally, the applicability of the fabricated devices for capillary electrophoresis was evaluated by separation of caffein, paracetamol and ketoprofone using absorbance detection at 254 nm.  相似文献   

17.
This work demonstrates the application of dielectrophoretic (DEP) control of silica nanoparticles to form tuneable optical elements within a microfluidic system. The implementation consisted of a microfluidic channel with an array of curved microelectrodes along its base. Various DEP conditions were investigated at alternating current voltage amplitudes, flow rates and frequencies from 5 to 15 V, 2 to 10 μL/min and 0 to 20 MHz, respectively. The fluid channel was filled with deionized water suspending silica particles with diameters of 230 and 450 nm. Experiments were conducted to demonstrate DEP concentration and deflection of the particles and the impact of these particles distributions on the optical transmission through the fluid channel. Both confinement and scattering of the light were observed depending on the particle dimensions and the parameters of the DEP excitation. The results of this investigation illustrate the feasibility of DEP control in an optofluidic system and represent a significant step toward the dynamic formation of electrically controlled liquid optical waveguides.  相似文献   

18.
Lim JM  Kim SH  Choi JH  Yang SM 《Lab on a chip》2008,8(9):1580-1585
We have demonstrated fluorescent liquid-core/air-cladding (LA) waveguides suitable for use as integrated optofluidic light sources. These waveguides were fabricated by conventional soft lithography using poly(dimethylsiloxane) (PDMS). Two-phase stratified flows of air and ethylene glycol with fluorescent dye were generated along the PDMS channel. Compared to the liquid-core/liquid-cladding (L(2)) waveguide, the larger refractive index contrast of the LA waveguide resulted in stronger optical confinement. Specifically, the larger refractive index contrast led to experimentally achievable captured fractions (the amount of light to be coupled into the liquid core) as high as 22.8% and the measured propagation losses as low as 0.14 dB cm(-1). Furthermore, in our LA waveguides, diffusional mixing of the core and cladding fluids did not occur and the size of the core stream could be reversibly tuned simply by adjusting the flow rates of the two contiguous phases.  相似文献   

19.
Lapsley MI  Chiang IK  Zheng YB  Ding X  Mao X  Huang TJ 《Lab on a chip》2011,11(10):1795-1800
We have developed a planar, optofluidic Mach-Zehnder interferometer for the label-free detection of liquid samples. In contrast to most on-chip interferometers which require complex fabrication, our design was realized via a simple, single-layer soft lithography fabrication process. In addition, a single-wavelength laser source and a silicon photodetector were the only optical equipment used for data collection. The device was calibrated using published data for the refractive index of calcium chloride (CaCl(2)) in solution, and the biosensing capabilities of the device were tested by detecting bovine serum albumin (BSA). Our design enables a refractometer with a low limit of detection (1.24 × 10(-4) refractive index units (RIU)), low variability (1 × 10(-4) RIU), and high sensitivity (927.88 oscillations per RIU). This performance is comparable to state-of-the-art optofluidic refractometers that involve complex fabrication processes and/or expensive, bulky optics. The advantages of our device (i.e. simple fabrication process, straightforward optical equipment, low cost, and high detection sensitivity) make it a promising candidate for future mass-producible, inexpensive, highly sensitive, label-free optical detection systems.  相似文献   

20.
The fabrication and performance of a microfluidic device with integrated liquid-core optical waveguides for laser induced fluorescence DNA fragment analysis is presented. The device was fabricated through poly(dimethylsiloxane) (PDMS) soft lithography and waveguides are formed in dedicated channels through the addition of a liquid PDMS pre-polymer of higher refractive index. Once a master has been fabricated, microfluidic chips can be produced in less than 3 h without the requirement for a cleanroom, yet this method provides an optical system that has higher performance than a conventional confocal optical assembly. Optical coupling was achieved through the insertion of optical fibers into fiber-to-waveguide couplers at the edge of the chip and the liquid-fiber interface results in low reflection and scattering losses. Waveguide propagation losses are measured to be 1.8 dB cm(-1) (532 nm) and 1.0 dB cm(-1) (633 nm). The chip displays an average total coupling loss of 7.6 dB due to losses at the optical fiber interfaces. In the electrophoretic separation and detection of a BK virus PCR product, the waveguide system achieves an average signal-to-noise ratio of 570 +/- 30 whereas a commercial confocal benchtop electrophoresis system achieves an average SNR of 330 +/- 30. To our knowledge, this is the first time that a waveguide-based system has been demonstrated to have a SNR comparable to a commercially available confocal-based system for microchip capillary electrophoresis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号