首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 576 毫秒
1.
A method was developed for determination of total dietary fiber (TDF) in foods containing resistant maltodextrin (RMD) which includes nondigestible carbohydrates that are not fully recovered as dietary fiber by conventional TDF methods such as AOAC 985.29 or 991.43. Because the average molecular weight (MW) of RMD is 2000 daltons, lower MW soluble dietary fiber components do not precipitate in 78% ethanol; therefore, RMD is not completely quantitated as dietary fiber by current AOAC methods. The accuracy and precision of the method was evaluated through an AOAC collaborative study. Ten laboratories participated and assayed 12 test portions (6 blind duplicates) containing RMD. The 6 test pairs ranged from 1.5 to 100% RMD. The method consisted of the following steps: (1) The insoluble dietary fiber (IDF) and high MW soluble dietary fiber (HMWSDF) were determined by AOAC 985.29. (2) Ion exchange resins were used to remove salts and proteins contained in the AOAC 985.29 filtrates (including ethanol and acetone). (3) The amount of low MWRMD (LMWRMD) in the filtrates were determined by liquid chromatography. (4) The TDF was calculated by summation of the IDF, HMWSDF, and LMWRMD fractions having nondigestible carbohydrates with a degree of polymerization of 3 and higher. Repeatability standard deviations (RSDr) were 1.33-7.46%, calculated by including outliers, and 1.33-6.10%, calculated by not including outliers. Reproducibility standard deviations (RSDR) were 2.48-9.39%, calculated by including outliers, and 1.79-9.39%, calculated by not including outliers. This method is recommended for adoption as Official First Action.  相似文献   

2.
A method for the determination of insoluble (IDF), soluble (SDF), and total dietary fiber (TDF), as defined by the CODEX Alimentarius, was validated in foods. Based upon the principles of AOAC Official Methods 985.29, 991.43, 2001.03, and 2002.02, the method quantitates water-insoluble and water-soluble dietary fiber. This method extends the capabilities of the previously adopted AOAC Official Method 2009.01, Total Dietary Fiber in Foods, Enzymatic-Gravimetric-Liquid Chromatographic Method, applicable to plant material, foods, and food ingredients consistent with CODEX Definition 2009, including naturally occurring, isolated, modified, and synthetic polymers meeting that definition. The method was evaluated through an AOAC/AACC collaborative study. Twenty-two laboratories participated, with 19 laboratories returning valid assay data for 16 test portions (eight blind duplicates) consisting of samples with a range of traditional dietary fiber, resistant starch, and nondigestible oligosaccharides. The dietary fiber content of the eight test pairs ranged from 10.45 to 29.90%. Digestion of samples under the conditions of AOAC 2002.02 followed by the isolation, fractionation, and gravimetric procedures of AOAC 985.29 (and its extensions 991.42 and 993.19) and 991.43 results in quantitation of IDF and soluble dietary fiber that precipitates (SDFP). The filtrate from the quantitation of water-alcohol-insoluble dietary fiber is concentrated, deionized, concentrated again, and analyzed by LC to determine the SDF that remains soluble (SDFS), i.e., all dietary fiber polymers of degree of polymerization = 3 and higher, consisting primarily, but not exclusively, of oligosaccharides. SDF is calculated as the sum of SDFP and SDFS. TDF is calculated as the sum of IDF and SDF. The within-laboratory variability, repeatability SD (Sr), for IDF ranged from 0.13 to 0.71, and the between-laboratory variability, reproducibility SD (SR), for IDF ranged from 0.42 to 2.24. The within-laboratory variability Sr for SDF ranged from 0.28 to 1.03, and the between-laboratory variability SR for SDF ranged from 0.85 to 1.66. The within-laboratory variability Sr for TDF ranged from 0.47 to 1.41, and the between-laboratory variability SR for TDF ranged from 0.95 to 3.14. This is comparable to other official and approved dietary fiber methods, and the method is recommended for adoption as Official First Action.  相似文献   

3.
AOAC Official Method(SM) 2005.06 for the determination of saxitoxin (STX)-group toxins in shellfish by LC with fluorescence detection with precolumn oxidation was previously validated and adopted First Action following a collaborative study. However, the method was not validated for all key STX-group toxins, and procedures to quantify some of them were not provided. With more STX-group toxin standards commercially available and modifications to procedures, it was possible to overcome some of these difficulties. The European Union Reference Laboratory for Marine Biotoxins conducted an interlaboratory exercise to extend AOAC Official Method 2005.06 validation for dc-GTX2,3 and to compile precision data for several STX-group toxins. This paper reports the study design and the results obtained. The performance characteristics for dc-GTX2,3 (intralaboratory and interlaboratory precision, recovery, and theoretical quantification limit) were evaluated. The mean recoveries obtained for dc-GTX2,3 were, in general, low (53.1-58.6%). The RSD for reproducibility (RSD(r)%) for dc-GTX2,3 in all samples ranged from 28.2 to 45.7%, and HorRat values ranged from 1.5 to 2.8. The article also describes a hydrolysis protocol to convert GTX6 to NEO, which has been proven to be useful for the quantification of GTX6 while the GTX6 standard is not available. The performance of the participant laboratories in the application of this method was compared with that obtained from the original collaborative study of the method. Intralaboratory and interlaboratory precision data for several STX-group toxins, including dc-NEO and GTX6, are reported here. This study can be useful for those laboratories determining STX-group toxins to fully implement AOAC Official Method 2005.06 for official paralytic shellfish poisoning control. However the overall quantitative performance obtained with the method was poor for certain toxins.  相似文献   

4.
Four laboratories participated in a mini-collaborative study of AOAC Official Method 971.22, Standards for Aflatoxins, Thin-Layer Chromatographic Method, to extend the method to 3 replacement solvents for benzene for calibration of standard aflatoxin solutions. Triplicate test sample vials, each containing 25 micrograms of the respective aflatoxin for each of the 4 aflatoxins and for each of the solvents, were prepared and sent to each collaborator. The collaborators dissolved the aflatoxin in each vial in 2 mL solvent, measured the UV spectrum, and reported the absorptivity maxima near 350 nm. The concentrations of the aflatoxins in the test samples were determined by dissolving identical test samples in benzene-acetonitrile (98 + 2) and following the procedure described in AOAC Official Method 971.22. These concentrations were, in turn, used to determine the molar absorptivities in the other 3 solvents (see Table 1). AOAC Official Method 971.22 has been modified to extend its applicability to 3 replacement solvents for benzene for calibration of standard aflatoxin solutions.  相似文献   

5.
A collaborative study was performed to determine the reproducibility of a method for the determination of methylcellulose (MC) and hydroxypropyl methylcellulose (HPMC) in food. These widely used food gums possess unusual solubility characteristics and cannot accurately be determined by existing dietary fiber methods. The new method uses the enzyme-digestion procedure of AOAC Official Method 991.43. Digestate solutions must be refrigerated to fully hydrate MC or HPMC. The chilled solutions are filtered and analyzed by size-exclusion liquid chromatography. Collaborating laboratories received 28 samples containing MC or HPMC in the range of 0-100%. The sample set included blind duplicates of 5 food matrixes (bread, milk, fish, potato, and powdered juice drink). Cochran and Grubbs tests were used to eliminate outliers. For food samples containing MC, values for within-laboratory precision, repeatability relative standard deviation (RSDr), ranged from 4.2 to 16%, and values for among-laboratories precision, reproducibility relative standard deviation (RSDR), ranged from 11 to 20%. For HPMC samples, RSDr values ranged from 6.4 to 27%, and RSDR values ranged from 17 to 39%. Recoveries of MC and HPMC from the food matrixes ranged from 78 to 101%. These results show acceptable precision and reproducibility for the determination of MC and HPMC, for which no Official AOAC Methods exist. It is recommended that this method be adopted as AOAC Official First Action.  相似文献   

6.
A method is described for the measurement of dietary fibre, including resistant starch (RS), non-digestible oligosaccharides (NDO) and available carbohydrates. Basically, the sample is incubated with pancreatic α-amylase and amyloglucosidase under conditions very similar to those described in AOAC Official Method 2002.02 (RS). Reaction is terminated and high molecular weight resistant polysaccharides are precipitated from solution with alcohol and recovered by filtration. Recovery of RS (for most RS sources) is in line with published data from ileostomy studies. The aqueous ethanol extract is concentrated, desalted and analysed for NDO by high-performance liquid chromatography by a method similar to that described by Okuma (AOAC Method 2001.03), except that for logistical reasons, d-sorbitol is used as the internal standard in place of glycerol. Available carbohydrates, defined as d-glucose, d-fructose, sucrose, the d-glucose component of lactose, maltodextrins and non-resistant starch, are measured as d-glucose plus d-fructose in the sample after hydrolysis of oligosaccharides with a mixture of sucrase/maltase plus β-galactosidase.  相似文献   

7.
In 1996, U.S. Food and Drug Administration regulations mandated the fortification of enriched cereal-grain products with folic acid, thereby emphasizing the need for validated methods for total folates in foods, particularly cereal products. The AOAC Official Methods (944.12, 960.46) currently used for the analysis of folate in foods for compliance purposes are microbiological methods. When the fortification regulations were finalized, no Official AOAC or Approved AACC methods for folate in cereal-grain products were in place. The AOAC Official Method (992.05) for folic acid in infant formula does not incorporate important improvements in the extraction procedure and was not considered suitable for the analysis of folates in foods in general. A microbiological assay protocol using a trienzyme extraction procedure was prepared and submitted for comments to 40 laboratories with recognized experience in folate analysis. On the basis of comments, the method was revised to have the conjugase (gamma-glutamyl-carboxy-peptidase) treatment follow a protease treatment, to include the use of cryoprotected inoculum, and to include the spectroscopic standardization of the standard and optional use of microtiter plates. Thirteen laboratories participated in a collaborative study of 10 required and 10 optional cereal-grain products, including flour, bread, cookies, baking mixes, and ready-to-eat breakfast cereals. The majority of the participating laboratories performed the assay by the standard test tube method; others used the microtiter plate modification for endpoint quantitation with equal success. For the required products, the relative standard deviation between laboratories (RSD(R)) ranged from 7.4 to 21.6% for 8 fortified (or enriched) products compared with expected (Horwitz equation-based) values of 11-20%. RSD(R) values were higher (22.7-52.9%) for 2 unfortified cereal-grain products. For the optional products, the RSD(R) ranged from 1.8 to 11.2% for 8 fortified products. RSD(R) values were higher (27.9-28.7%) for 2 unfortified cereal-grain products. Based on the results of the collaborative study, the microbiological assay with trienzyme extraction is recommended for adoption as Official First Action.  相似文献   

8.
An HPLC-FLD method, involving pre-chromatographic oxidation of the PSP toxins with hydrogen peroxide and periodate, has been AOAC validated through a collaborative trial and adopted as AOAC Official Method. This method could be a candidate for replacing the mouse bioassay (MBA) for the Official Control of PSP toxins at European level, once accepted by the legislation. An interlaboratory exercise has been organized by the CRLMB to evaluate its "fitness for purpose" for the Official Control of PSP toxins in the EU laboratories. Eighteen EU laboratories took part in the study and had to analyze six bivalve mollusc samples with several PSP toxic profiles. The performance of the participant laboratories in the application of this method was compared with that obtained at the collaborative trial. Information on problems/drawbacks encountered by participants in the application of this method was also sought. The HPLC validated method is only applicable for Official PSP Control for certain samples. This depends on sample PSP toxic profile. Results obtained for samples where only GTX2,3 and STX were present were satisfactory and in agreement with MBA results. Results obtained for a sample with a toxic profile dominated by GTX6 and suspected to contain also C1,2 and C3,4 were not satisfactory. GTX5 and dc-STX could be quantified, although the results achieved (total toxicity) were lower than those obtained by MBA. It can be also useful as a screening method, complementary to MBA, helping in the reduction of the animals used. However, the lack of several PSP standards, the fact that the method is not validated for all the PSP toxins, and several drawbacks found in its application are a handicap to fully implement it for Official PSP Control as a viable replacement for bioassay.  相似文献   

9.
A revised method to determine solubility of nitrogen in dilute pepsin, using 0.0002% pepsin in place of 0.2% in AOAC Official Method 971.09, was tested in 16 laboratories with 12 samples of fishmeal. Results were calculated according to 2 procedures: AOAC Official Method 971.09 and a method described in 1964 by researchers at the Torry Research Station (Aberdeen, Scotland), and generally referred to as the modified Torry method. Variations in the method of shaking and source of pepsin were also investigated. Pepsin solubility values were lower and more variable when calculated by the Torry procedure. The method of shaking apparently affected the result when calculated according to the Torry but not the AOAC method. The source of pepsin had no significant effect on between-laboratory variability, but a comparison of the 2 main sources within one laboratory resulted in highly significant differences. Based on this study, the International Fishmeal and Fish Oil Organization has adopted this new method, using 0.0002% pepsin but keeping the AOAC method of calculation. The type of shaker and source of pepsin are recommended but are not mandatory. The repeatability and reproducibility limits of this new method are 1.6 and 3.3% units of solubility, respectively.  相似文献   

10.
Validated methods of analysis are needed for many purposes: enforcement of regulations, import/export control, in accredited laboratories, academia, institutions. The AOAC INTERNATIONAL Official Methods Program is designed to provide fully validated methods of analysis, based on interlaboratory testing by a minimum of eight laboratories. Another, lesser validation system is used for peer-verified methods of analysis where two or three laboratories participate. The system for performance testing of test kits is specially designed for a thorough testing of manufacturer claims, and can be obtained by submitting a kit to Performance Testing by the AOAC Research Institute.  相似文献   

11.
AOAC Official Method 2005.06 LC-fluorescence detection (FLD) method is an official alternative to the mouse bioassay for the determination of paralytic shellfish poisoning (PSP) toxins in bivalve shellfish. To validate the method for species of relevance to the UK official control monitoring program, the method performance characteristics were tested for whole king and queen scallops. Validation showed that, while the performance was generally acceptable for the quantitation of non-N-hydroxylated toxins, poor toxin recovery and sensitivity was evident for the analysis of N-hydroxylated toxins following periodate oxidation. These effects occurred in a range of scallop samples with variable temporal and spatial sources. The effects were also noted in other laboratories following a small interlaboratory study. As a result, the method was refined to improve the recovery and sensitivity of analysis following the periodate oxidation step in the PSP method for scallops. Performance improved through alterations to the preparation of the periodate oxidant, use of higher volumes for C18 cleanup, and injection volumes in combination with the use of a king scallop matrix modifier for oxidation of N-hydroxylated toxin calibration standards. A single-laboratory validation of the refined method showed that the selectivity, linearity, sensitivity, recovery, and precision were acceptable and similar to values reported previously for AOAC Official Method 2005.06 in other bivalve species. Results showed the method to be rugged for all parameters investigated, including small changes to the composition of the new periodate reagent utilized in the refined method. The refined scallops LC method was subsequently compared with the European reference method. PSP-positive scallops showed an excellent agreement between the methods for queen and Atlantic scallops, with a small level of positive bias in the LC results for whole king scallops. These differences were related solely to the use of the highest toxicity equivalence factors for toxin epimeric pairs, with gonyautoxin (GTX)1,4 and GTX2,3 in particular present at high concentrations in the king scallops. Overall, the refined LC-FLD method improved the performance characteristics of AOAC Official Method 2005.06 for the determination of PSP toxins in whole king and queen scallops, and showed a good overall agreement between the official methodologies. It is, therefore, recommended as a more appropriate option for the routine monitoring of PSP toxins in these species.  相似文献   

12.
A procedural modification of the AOAC Official Method for extracting light filth from ground oregano and ground marjoram was tested in an intralaboratory study. The modified method specifies isopropanol defatting, 975.49A(a), rather than chloroform-isopropanol defatting, 975.49A(b), followed by direct flotation as directed in AOAC Official Method, 975.49B(b). The modified method provided comparable results in less time while also providing safety, health, and financial benefits.  相似文献   

13.
A new method for detection of Salmonella in foods in a minimum of 24 h was adopted as an AOAC Official First Action Method for selected foods (2001.09) using both the VIDAS Immuno-Concentration Salmonella (ICS) and VIDAS Salmonella (SLM) methods.  相似文献   

14.
The 3M Petrifilm Staph Express Count plate method was compared with AOAC Official Method 975.55 for the enumeration of Staphylococcus aureus in selected foods. Five foods--ice cream, raw milk, yogurt, whey powder, and cheese--were analyzed for S. aureus by 12 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample, a low inoculation level, a medium inoculation level, and a medium inoculation level with background flora, each in duplicate. The mean log10 counts for the methods were comparable for all 5 foods. The repeatability and reproducibility variances of the 24 h Petrifilm Staph Express Count plate method were similar to those of the 72 h standard method.  相似文献   

15.
The 3M Petrifilm Staph Express Count plate method was compared with AOAC Official Method 975.55 for the enumeration of Staphylococcus aureus in selected foods. Four foods--cooked, diced chicken; cured ham; smoked salmon; and pepperoni--were analyzed for S. aureus by 12 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample, a low inoculation level, a medium inoculation level, and a medium inoculation level with background flora, each in duplicate. The mean log10 counts for the methods were comparable for all 4 foods. The repeatability and reproducibility variances of the 24 h Petrifilm Staph Express Count plate method were similar to those of the 72 h standard method.  相似文献   

16.
The applicability of AOAC Official Method 992.06, vitamin A (retinol) in milk-based infant formula can be extended to specialty infant formulas, and medical and adult nutritional products with a few minor modifications to the sample preparation procedure. Currently, AOAC Official Method 992.06 is only applicable to milk-based infant formulas containing >500 IU vitamin A per reconstituted quart. When this method is used as written to test specialty infant formulas, vitamin A recoveries are low compared to results generated with alternate validated vitamin A methods. AOAC Method 992.06 vitamin A recoveries can be improved significantly in specialty infant formulas if the amount of potassium hydroxide used during the saponification step is doubled. With this one minor modification to the sample preparation procedure, AOAC Method 992.06 demonstrates acceptable precision and accuracy for the quantitation of vitamin A (retinol) in specialty infant formulas, milk- and soy-based infant formulas, and adult and medical nutritionals. Because increasing the amount of potassium hydroxide can cause emulsions to form, 2-4 mL aliquots of reagent alcohol may need to be added to some samples to separate the organic and aqueous layers during the extraction step. A single-laboratory validation of these modifications was completed. During validation, 15 different product matrixes were analyzed. The intermediate precision averaged 2.70% RSD, and spike recovery data averaged 96.3%.  相似文献   

17.
The 3M Petrifilm Staph Express Count plate method was compared with AOAC Official Method 975.55 for the enumeration of Staphylococcus aureus in selected foods. Five foods--frozen lasagna, custard, frozen mixed vegetables, frozen hashbrowns, and frozen batter-coated mushrooms--were analyzed for S. aureus by 13 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample, a low inoculation level, a medium inoculation level, and a medium inoculation level with background flora, each in duplicate. The mean log10 counts for the methods were comparable for all 5 foods. The repeatability and reproducibility variances of the 24 h Petrifilm Staph Express Count plate method were similar to those of the 72 h standard method.  相似文献   

18.
A new method for detection of Salmonella in foods in 48 h has been granted AOAC First Action approval in selected foods (Official Method 2001.08) using both the VIDAS Immuno-Concentration Salmonella (ICS) method and a combination of 3 selective plates: Hektoen enteric (HE), bismuth sulfite (BS), and xylose lysine desoxycholate (XLD).  相似文献   

19.
The relative efficacy of the SimPlate Total Plate Count-Color Indicator (TPC-CI) method (SimPlate 35 degrees C) was compared with the AOAC Official Method 966.23 (AOAC 35 degrees C) for enumeration of total aerobic microorganisms in foods. The SimPlate TPC-CI method, incubated at 30 degrees C (SimPlate 30 degrees C), was also compared with the International Organization for Standardization (ISO) 4833 method (ISO 30 degrees C). Six food types were analyzed: ground black pepper, flour, nut meats, frozen hamburger patties, frozen fruits, and fresh vegetables. All foods tested were naturally contaminated. Nineteen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery among the SimPlate methods and their corresponding reference methods. Mean log counts between the 2 reference methods were also very similar. Repeatability (Sr) and reproducibility (SR) standard deviations were similar among the 3 method comparisons. The SimPlate method (35 degrees C) and the AOAC method were comparable for enumerating total aerobic microorganisms in foods. Similarly, the SimPlate method (30 degrees C) was comparable to the ISO method when samples were prepared and incubated according to the ISO method.  相似文献   

20.
The Visual Immunoprecipitate (VIP) for the Detection of Salmonella in Foods, AOAC Official Method 999.09, has been modified to use a simplified housing for the device. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method. Three foods were analyzed. In total, valid results were obtained from 125 samples and controls. Results showed that the modified VIP for Salmonella is equivalent to the reference culture methods for the detection of Salmonella.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号