1.
The electrochemical oxidation of L-cysteine (CySH) in presence of carbon nanotubes (CNTs) formed a composite film at a glassy carbon electrode (GCE) as a novel modifier for directly electroanalytical determination of terbinafine without sample pretreatment in biological fluid. The determination of terbinafine at the modified electrode with strongly accumulation was studied by differential pulse voltammetry (DPV). The peak current obtained at +1.156 V (vs. SCE) from DPV was linearly dependent on the terbinafine concentration in the range of 8.0 x 10(-8)-5.0 x 10(-5 )M in a B-R buffer solution (0.04 M, pH 1.81) with a correlation coefficient of 0.998. The detection limit (S/N=3) was 2.5 x 10(-8 )M. The low-cost modified electrode showed good sensitivity, selectivity, and stability. This developed method had been applied to the direct determination of terbinafine in human serum samples with satisfactory results. It is hopeful that the modified electrode will be applied for the medically clinical test and the pharmacokinetics in future.  相似文献   

2.
Electrocatalytic oxidation of ascorbic acid (AA) at a carbon paste electrode, chemically modified 2,2'-[3,6-dioxa-1,8-octanediylbis(nitriloethylidyne)]-bis-hydroquinone, was thoroughly investigated. The results of cyclic voltammetry, double potential-step chronoamperometry, linear sweep voltammetry and differential pulse voltammetry (DPV) studies were used for the prediction of the mechanism of electrochemical oxidation of AA mediated with 2,2'-[3,6-dioxa-1,8-octanediylbis(nitriloethylidyne)]-bis-hydroquinone at the surface of the modified electrode. The diffusion coefficient (D = 2.45 x 10(-5) cm(2) s(-1)) and the kinetic parameters such as the electron transfer coefficient (alpha = 0.34) were also determined. The results of DPV using the 2,2'-[3,6-dioxa-1,8-octanediylbis(nitriloethylidyne)]-bis-hydroquinone-modified electrode were applied in a highly sensitive determination of AA in drug samples. A linear range of 3.0 x 10(-6) - 1.2 x 10(-4) M and the detection limit (3sigma) 3.8 x 10(-7) M were obtained for DPV determination of AA in buffered pH 7.00 solutions (0.1 M phosphate buffer).  相似文献   

3.
Graphene/p-aminobenzoic acid composite film modified glassy carbon electrode (Gr/p-ABA/GCE) was first employed for the sensitive determination of dopamine (DA). The electrochemical behavior of DA at the modified electrode was investigated by cyclic voltametry (CV), differential pulse voltametry (DPV) and amperometric curve. The oxidation peak currents of DA increased dramatically at Gr/p-ABA/GCE. The modified electrode was used to electrochemically detect dopamine (DA) in the presence of ascorbic acid (AA). The Gr/p-ABA composite film showed excellent electrocatalytic activity for the oxidation of DA in phosphate buffer solution (pH 6.5). The peak separation between DA and AA was large up to 220 mV. Using DPV technique, the calibration curve for DA determination was obtained in the range of 0.05-10 μM. The detection limit for DA was 20 nM. AA did not interfere with the determination of DA because of the very distinct attractive interaction between DA cations and the negatively Gr/p-ABA composite film. The proposed method exhibited good stability and reproducibility.  相似文献   

4.
A sensitive electrochemical method was developed for the differential pulse voltammetric determination of rhein at a glassy carbon electrode (GCE) modified with a nanoparticle composite film. In the present paper, multi-wall carbon nanotube (MWNT) was dispersed into dihexadecyl phosphate (DHP) to give a homogeneous suspension. After the solvent evaporation, a uniform film of MWNT-DHP composite film was obtained on the GCE surface. The MWNT-DHP composite film-modified GCE exhibited excellent electrocatalytic behavior toward the redox of rhein. Compared with an irreversible reduction of rhein at the bare GCE, a reversible redox behavior of rhein was observed at the MWNT-DHP composite film-modified GCE and the redox current was also enhanced greatly. Based on this, a cathodic differential pulse voltammetry (DPV) was applied for the determination of rhein. The experimental parameters, which influence the current of rhein, were optimized. Under optimal conditions, the cathodic DPV measurements were performed and a linear response of rhein was obtained in the range from 1.0 x 10(-8) to 5.0 x 10(-6) mol L(-1) and with a limit of detect (LOD) of 5.0 x 10(-9) mol L(-1). The proposed procedure was successfully applied to assay rhein in real samples with satisfactory results.  相似文献   

5.
The electrochemical behavior of colchicine at an acetylene black-dihexadecyl hydrogen phosphate (denoted as AB-DHP) composite film coated glassy carbon electrode (GCE) was investigated using cyclic voltammetry (CV), linear sweep voltammetry (LSV) and differential pulse voltammetry (DPV). Compared with the poor electrochemical signal at the unmodified GCE, the electrochemical response of colchicine at the AB-DHP film modified GCE was greatly improved, as confirmed from the significant peak current enhancement. The remarkable peak current enhancement indicates that the AB-DHP modified GCE has great potential in the sensitive determination of colchicine. Thus, all the experimental conditions, which influence the electrochemical response of colchicine, were studied and the optimum conditions were achieved. Finally, a sensitive and simple voltammetric method with a good linear relationship in the range of 1.0 x 10(-7) approximately 4.0 x 10(-5) mol/L, was developed for the determination of colchicine. The detection limit of colchicine was also examined and a low value of 4.0 x 10(-8) mol/L for 4-min accumulation was obtained (S/N=3). This electrode was successfully applied to detect colchicine in human urine samples.  相似文献   

6.
A novel poly-glutamic acid (PGA) film modified carbon paste electrode (CPE) incorporating carbon nanotubes (CNTs) was first prepared for the determination of l-tryptophan (l-Trp). Scanning electron microscopy and Fourier transform infrared spectroscopy were applied for characterization of the surface morphology of the modified electrodes and cyclic voltammetry was used to investigate the electrochemical properties of the proposed electrode towards the oxidation of l-Trp. Optimization of the experimental parameters was performed with regard to pH, ratio of CNTs, concentration of glutamic acid, electro-polymerization cycles, accumulation time and concentration of sodium dodecylbenzene sulfonate. The linearity between the oxidation peak current and the l-Trp concentration was obtained in the range of 5.0×10(-8) to 1.0×10(-4)M with a detection limit of 1.0×10(-8)M (S/N=3) and the sensitivity was calculated to be 1143.79μA?mM(-1)?cm(-2). In addition, the PGA modified CPE incorporating CNTs displayed high selectivity, good stability and reproducibility, making it suitable for the routine analysis of l-Trp in clinical use.  相似文献   

7.
A chemically modified carbon paste electrode (CPE), consisting of 2,2''-[(1E)-(1,2-phenylenebis(azanylylidene)] bis(methanylylidene)]bis(benzene-1,4-diol) (PBD) and multiwalled carbon nanotubes (CNTs), was used to study the electrocatalytic oxidation of dopamine using cyclic voltammetry, chronoamperometry, and differential pulse voltammetry (DPV). First, the electrochemical behavior of the modified electrode was investigated in buffer solution. Then the diffusion coefficient, electrocatalytic rate constant, and electron-transfer coefficient for dopamine oxidation at the surface of the PBD-modified CNT paste electrode were determined using electrochemical approaches. It was found that under optimum conditions (pH = 7.0), the oxidation of dopamine at the surface of such an electrode occurred at about 200 mV, lower than that of an unmodified CPE. DPV of dopamine at the modified electrode exhibited two linear dynamic ranges, with a detection limit of 1.0 μmol/L. Finally, DPV was used successfully for the simultaneous determination of dopamine, uric acid, and folic acid at the modified electrode, and detection limits of 1.0, 1.2, and 2.7 μmol/L were obtained for dopamine, uric acid, and folic acid, respectively. This method was also used for the determination of dopamine in a pharmaceutical preparation using the standard addition method.  相似文献   

8.
Luteolin is a flavonoid reported to occur widely in many medicinal plants. The electrochemical behavior of luteolin was studied in phosphate buffer solution (PBS) of pH 4.0 at a glassy carbon electrode (GCE) by cyclic voltammetry (CV) and differential pulse voltammetric method (DPV). The results indicated the well-defined redox peak of luteolin which was involving two electrons and two protons was observed and the electrode process is adsorption-controlled. The charge transfer coefficient (alpha) was calculated as 0.66. The relationships between oxidation peak current and the concentration of luteolin are linear in the range of 1.0 x 10(-8) - 1.0 x 10(-6) M by DPV method. The detection limit had been estimated as 5.0 x 10(-9) M. The facile and rapid method has been successfully applied to the detection of luteolin in tablets.  相似文献   

9.
The electrochemical oxidation of the antineoplastic agent etoposide was studied at carbon paste electrode in Britton-Robinson buffer solutions over the pH range 2.0-10.0 using cyclic, linear sweep and differential pulse voltammetry. Oxidation of the drug was effected in a single reversible, diffusion-controlled step within the pH range 2.0-4.0, a second oxidation process was produced above pH 4.0. Using differential pulse voltammetry (DPV), the drug yielded a well-defined voltammetric response in Britton-Robinson buffer, pH 3.0 at 0.500 V (vs. Ag/AgCl) on carbon paste electrode. This process could be used to determine etoposide concentrations in the range 2.5 x 10(-7) to 2.5 x 10(-5) M with a detection limit of 1.0 x 10(-7) M. The method was successfully applied to the determination of the drug in spiked human serum.  相似文献   

10.
Gao Z  Ivaska A  Zha T  Wang G  Li P  Zhao Z 《Talanta》1993,40(3):399-403
A carbon fibre microelectrode was modified by electrodeposition of a thin copper-heptacyanonitrosylferrate (CuHNF) film on its surface. The film showed the ability to catalyse electrochemical oxidation of ascorbic acid. The catalytic reaction was limited either by diffusion, or by the electrochemical reaction of the catalyst. A linear, cyclic voltammetric response for ascorbic acid was obtained between 5.0 x 10(-5) and 6.0 x 10(-3)M. By amperometric measurements the linear range could be extended to 8.0 x 10(-6)-2.0 x 10(-3)M. The modified electrode showed good stability and reproducibility.  相似文献   

11.
The electrochemical behavior of atorvastatin calcium at glassy carbon and boron-doped diamond electrodes has been studied using voltammetric techniques. The possible mechanism of oxidation was discussed with model compounds. The dependence of the peak current and potentials on pH, concentration, scan rate and nature of the buffer were investigated for both electrodes. The oxidation of atorvastatin was irreversible and exhibited a diffusion-controlled fashion on the diamond electrode. A linear response was obtained within the range of 9.65 x 10(-7) - 3.86 x 10(-5) M in 0.1 M H(2)SO(4) solution for both electrodes. The detection limits of a standard solution are estimated to be 2.11 x 10(-7) M with differential pulse voltammetry (DPV) and 2.05 x 10(-7)M with square wave voltammetry (SWV) for glassy carbon electrode, and 2.27 x 10(-7) M with DPV and 1.31 x 10(-7)M with SWV for diamond electrodes in 0.1 M H(2)SO(4) solution. The repeatability of the methods was found good for both electrodes. The methods were fully validated and successfully applied to the high-throughput determination of the drug in tablets, human serum and human urine with good recoveries.  相似文献   

12.
A novel palladium-polyphenosafranine nano-composite (PPS-Pd) was synthesized by electrochemical co-deposition at a glassy carbon electrode (GCE) for fabrication of a nitrite sensor, PPS-Pd/GCE. This PPS-Pd film was characterized by X-ray photoelectron spectroscopy (XPS) and field emission scanning electron microanalysis (SEM). It was found that the PPS-Pd nano-composite consisted of Pd nanoparticles smaller than 10 nm in diameter which stick together due to the polymer, forming a Pd-embedded PPS layer structure. The sensing ability was investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and differential pulse amperometry (DPA). The PPS-Pd/GCE had excellent catalytic activity toward the oxidation of nitrite: high current sensitivity of 0.365 A/M cm(-2), good reproducibility, good stability and fast response. In neutral solutions, a linear concentration range of 1.0 x 10(-6) to 1.1 x 10(-3) M (R(2) = 0.999) with the detection limit (s/n = 3) of 3 x 10(-7) M nitrite was obtained for DPV determination.  相似文献   

13.
Ozkan SA  Uslu B  Aboul-Enein HY 《Talanta》2003,61(2):147-156
The electrooxidative behavior and determination of Tamsulosin HCl (TAM), one of the alpha(1)-adrenoceptor antagonist, on a glassy carbon disc electrode were investigated for the first time by using cyclic, linear sweep, differential pulse (DPV) and square wave voltammetry (SWV). TAM showed an irreversible oxidation behavior at all pH values and buffers studied. From the electrochemical response, the main oxidation step was found to be related to the methoxy group on the phenyl ring. DPV and SWV were used to generate peak current versus concentration curves for TAM. A linear response was obtained in the range comprised between 2x10(-6) and 4x10(-4) M for both techniques with detection limit of 3.34x10(-7) M for DPV and 2.45x10(-7) M for SWV. The methods were proposed for the determination of TAM in dosage forms adopting both DPV and SWV modes. The methods were extended to the in vitro determination of TAM in spiked serum samples.  相似文献   

14.
Zhang L  Lin X 《The Analyst》2001,126(3):367-370
A novel covalently modified glassy carbon electrode with glutamic acid has been fabricated via an electrochemical oxidation procedure and was applied to the catalytic oxidation of uric acid (UA) and ascorbic acid (AA), reducing the overpotentials by about 0.2 V and 0.3 V, respectively. Based on its strong catalytic function toward the oxidation of UA and AA, the modified electrode resolved the overlapping voltammetric response of UA and AA into two well-defined voltammetric peaks with both cyclic voltammetry (CV) and differential pulse voltammetry (DPV), which can be used for the simultaneous determination of these species in a mixture. The catalytic peak current obtained from DPV was linearly dependent on the UA and AA concentration in the range 2 x 10(-6)-4 x 10(-4) mol L-1 and 1.0 x 10(-6)-4 x 10(-4) mol L-1 with correlation coefficients of 0.996 and 0.997, respectively. The detection limits (3 delta) for UA and AA were 1.1 x 10(-6) mol L-1 and 9.2 x 10(-7) mol L-1, respectively. The modified electrode shows good sensitivity, selectivity and stability, and has been applied to the determination of UA and AA simultaneously in human urine samples with satisfactory results.  相似文献   

15.
用一步电沉积法制备了纳米铜/石墨烯/壳聚糖复合膜修饰玻碳电极。用循环伏安法(CV)和差分脉冲伏安法(DPV)对邻苯二酚在该修饰电极的电化学行为进行了研究。实验结果表明,在pH值为7.0的磷酸盐缓冲液(PBS)中,该修饰电极对邻苯二酚具有良好的电催化作用,其电化学信号与邻苯二酚的浓度在1.0×10-6~2.0×10-4mol/L范围内呈良好的线性关系,线性相关系数为0.991。检出限为1×10-7mol/L。结果表明,纳米铜/石墨烯/壳聚糖复合膜修饰电极显著提高了邻苯二酚的电化学响应信号,并表现出良好的选择性和重现性。该方法成功用于水样中邻苯二酚含量的测定。  相似文献   

16.
A sensitive and selective electrochemical method for the determination of dopamine using an Evans Blue polymer film modified on glassy carbon electrode was developed. The Evans blue polymer film modified electrode shows excellent electrocatalytic activity toward the oxidation of dopamine in phosphate buffer solution (pH 4.5). The linear range of 1.0 x 10(-6)-3.0 x 10(-5) M and detection limit of 2.5 x 10(-7) M were observed in pH 4.5 phosphate buffer solutions. The interference studies showed that the modified electrode exhibits excellent selectivity in the presence of large excess of ascorbic acid and uric acid. The separation of the oxidation peak potentials for dopamine-ascorbic acid and dopamine-uric acid were about 182 mV and 180 mV, respectively. The differences are large enough to determine AA, DA and UA individually and simultaneously. This work provides a simple and easy approach to selectively detect dopamine in the presence of ascorbic acid and uric acid in physiological samples.  相似文献   

17.
The oxidative behaviour of, a hypnotic drug, zolpidem was studied at glassy carbon electrode in Britton-Robinson buffer over the pH range 2.0-11.0 using cyclic, linear sweep and differential pulse voltammetry. Oxidation of the drug was effected in a single irreversible, diffusion-controlled step. Using differential pulse voltammetry (DPV), the drug yielded a well-defined voltammetric response in Britton-Robinson buffer, pH 8.0 at +0.889 V (vs. Ag/AgCl) on glassy carbon electrode. This process could be used to determine zolpidem concentrations in the range 5.0 x 10(-7) M to 1.0 x 10(-5) M with a detection limit of 2.0 x 10(-7) M. The method was applied, without any interference from the excipients, to the determination of the drug in a tablet dosage form.  相似文献   

18.
应用吸附法将羊抗人IgG抗体直接固定于纳米金(GNPs)/壳聚糖(Chit)掺杂碳纳米管(CNTs)修饰的金电极表面,制备了用于人IgG抗原检测的非标记电化学免疫传感器.利用循环伏安法和交流阻抗研究了修饰电极表面的电化学特性,用差分脉冲伏安法研究了测试底液的pH值对免疫传感器性能的影响.实验表明,在含不同浓度人IgG的...  相似文献   

19.
Jiang X  Lin X 《The Analyst》2005,130(3):391-396
The overoxidized polypyrrole (PPyox) film as a template for DNA immobilization has been demonstrated in this paper. The DNA molecules inserted into the micropores of the ultrathin PPyox matrix under the driving forces of an electric field and were firmly immobilized on the carbon fiber electrode (CFE). Such a DNA-PPyox biocomposite layer exhibited more effective rejection of anionic ascorbate (AA) and uric acid (UA) and more preferential collection of the cationic dopamine (DA) and epinephrine (EP) than pure PPyox and DNA coatings. The DPV peak currents increased linearly with increasing DA and EP concentrations in the range of 3.0 x 10(-7) to 1.0 x 10(-5) M and 5.0 x 10(-7) to 2.0 x 10(-5) M with the lowest detected concentrations of 8.0 x 10(-8) M and 6.0 x 10(-8) M, respectively. The electrochemical signal of AA could be totally suppressed under a concentration of 20 mM and beyond this concentration, the overlapped responses of AA, DA/EP and UA could be resolved into three well-defined voltammetric peaks. The selectivity factors k(DA/AA) and k(EP/AA) were about 5000 and 2000 for an equal concentration in the presence of 0.5 mM UA. The properties of the biocomposite film have been characterized by atomic force microscopy and electrochemical investigations.  相似文献   

20.
Glassy carbon electrode (GCE) is covalently modified with aspartic acid (Asp). The modified electrode is used for the simultaneous electrochemical determination of hydroquinone (HQ) and catechol (CC) and shows an excellent electrocatalytical effect on the oxidation of HQ and CC by cyclic voltammetry (CV) in 0.1 mol/L acetate buffer solution (pH 4.5). In differential pulse voltammetric (DPV) measurements, the modified electrode could separate the oxidation peak potentials of HQ and CC present in binary mixtures by about 101 mV though the bare electrode gave a single broad response. A successful elimination of the fouling effect by the oxidized product of HQ on the response of CC has been achieved at the modified electrode. The determination limit of HQ in the presence of 0.1 mmol/L CC was 9.0 x 10(-7) mol/L and the determination limit of CC in the presence of 0.1 mmol/L HQ was 5.0 x 10(-7) mol/L. The proposed method has been applied to the simultaneous determination of HQ and CC in a water sample with simplicity and high selectivity.  相似文献   