首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 640 毫秒
1.
Techniques in mass spectrometry (MS) combined with chemical cross-linking have proven to be efficient tools for the rapid determination of low-resolution three-dimensional (3-D) structures of proteins. The general procedure involves chemical cross-linking of a protein followed by enzymatic digestion and MS analysis of the resulting peptide mixture. These experiments are generally fast and do not require large quantities of protein. However, the large number of peptide species created from the digestion of cross-linked proteins makes it difficult to identify relevant intermolecular cross-linked peptides from MS data. We present a method for mapping low-resolution 3-D protein structures by combining chemical cross-linking with high-resolution FTICR (Fourier transform ion-cyclotron resonance) mass spectrometry using cytochrome c and hen egg lysozyme as model proteins. We applied several homo-bifunctional, amine-reactive cross-linking reagents that bridge distances from 6 to 16 A. The non-digested cross-linking reaction mixtures were monitored by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) to determine the extent of cross-linking. Enzymatically digested reaction mixtures were separated by nano-high-performance liquid chromatography (nano-HPLC) on reverse-phase columns applying water/acetonitrile gradients with flow rates of 200 nL/min. The nano-HPLC system was directly coupled to an FTICR mass spectrometer equipped with a nano-ESI (electrospray ionization) source. Cross-linking products were identified using a combination of the GPMAW software and ExPASy Proteomics tools. For correct assignment of the cross-linking products the key factor is to rely on a mass spectrometric method providing both high resolution and high mass accuracy, such as FTICRMS. By combining chemical cross-linking with FTICRMS we were able to rapidly define several intramolecular constraints for cytochrome c and lysozyme.  相似文献   

2.
High-performance liquid chromatography–electrospray ionization tandem mass spectrometry (HPLC–ESI-MS–MS) is regarded as one of the most powerful techniques for separation and identification of proteins. Recently, much effort has been made to improve the separation capacity, detection sensitivity, and analysis throughput of micro- and nano-HPLC, by increasing column length, reducing column internal diameter, and using integrated techniques. Development of HPLC columns has also been rapid, as a result of the use of submicrometer packing materials and monolithic columns. All these innovations result in clearly improved performance of micro- and nano-HPLC for proteome research.  相似文献   

3.
Accurately measured peptide masses can be used for large-scale protein identification from bacterial whole-cell digests as an alternative to tandem mass spectrometry (MS/MS) provided mass measurement errors of a few parts-per-million (ppm) are obtained. Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) routinely achieves such mass accuracy either with internal calibration or by regulating the charge in the analyzer cell. We have developed a novel and automated method for internal calibration of liquid chromatography (LC)/FTICR data from whole-cell digests using peptides in the sample identified by concurrent MS/MS together with ambient polydimethylcyclosiloxanes as internal calibrants in the mass spectra. The method reduced mass measurement error from 4.3 +/- 3.7 ppm to 0.3 +/- 2.3 ppm in an E. coli LC/FTICR dataset of 1000 MS and MS/MS spectra and is applicable to all analyses of complex protein digests by FTICRMS.  相似文献   

4.
A commercially available 9.4 Tesla Fourier transform ion cyclotron resonance (FTICR) mass spectrometer was applied in the analysis of tryptic digests of protein mixtures without any separation. First, the method was demonstrated on a mixture of tryptic digests of equine cytochrome c, equine myoglobin and bovine serum albumin. The same method was then applied to human plasma from a healthy blood donor. Computer programs were employed to simplify analysis of the complex spectra. The 2745 peaks in the human plasma electrospray ionization FTICR spectrum could be reduced to 1165 isotopic clusters and 669 unique masses. Out of these, 82 masses matched tryptic fragments of serum albumin with mass measurement errors less than 10 ppm, covering 93% of the sequence. Another 16 masses were assigned to tryptic fragments of transferrin, covering 41% of the sequence on the 10 ppm mass measurement error level (14 within 2 ppm). The mass measurement errors were approximately normal distributed with a standard deviation of 1.7 ppm. This demonstrates the feasibility of combining the ultra-high mass resolving power and accuracy of FTICR mass spectrometry with automated computer analysis for investigating complex biological matrices.  相似文献   

5.
Many biomarker discovery studies are based on matrix-assisted laser desorption/ionisation (MALDI) peptide profiles. In this study, 96 human serum samples were analysed on a Bruker solariX(TM) MALDI Fourier transform ion cyclotron resonance (FTICR) system equipped with a 15 tesla magnet. Isotopically resolved peptides were observed in ultrahigh resolution FTICR profiles up to m/z 6500 with mass measurement errors (MMEs) of previously identified peptides at a sub-ppm level. For comparison with our previous platform for peptide profile mass analysis (i.e. Ultraflex II) the corresponding time-of-flight (TOF) spectra were obtained with isotopically resolved peptides up to m/z 3500. The FTICR and TOF systems performed rather similar with respect to the repeatability of the signal intensities. However, the mass measurement precision improved at least 10-fold in ultrahigh resolution data and thus simplified spectral alignment necessary for robust and quantitatively precise comparisons of profiles in large-scale clinical studies. From each single MALDI-FTICR spectrum an m/z-list was obtained with sub-ppm precision for all different species, which is beneficial for identification purposes and interlaboratory comparisons. Furthermore, the FTICR system allowed new peptide identifications from collision-induced dissociation (CID) spectra using direct infusion of reversed-phase (RP) C(18)-fractionated serum samples on an electrospray ionisation (ESI) source.  相似文献   

6.
For structural studies of proteins and their complexes, chemical cross-linking combined with mass spectrometry presents a promising strategy to obtain structural data of protein interfaces from low quantities of proteins within a short time. We explore the use of isotope-labeled cross-linkers in combination with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry for a more efficient identification of cross-linker containing species. For our studies, we chose the calcium-independent complex between calmodulin and a 25-amino acid peptide from the C-terminal region of adenylyl cyclase 8 containing an "IQ-like motif." Cross-linking reactions between calmodulin and the peptide were performed in the absence of calcium using the amine-reactive, isotope-labeled (d0 and d4) cross-linkers BS3 (bis[sulfosuccinimidyl]suberate) and BS2G (bis[sulfosuccinimidyl]glutarate). Tryptic in-gel digestion of excised gel bands from covalently cross-linked complexes resulted in complicated peptide mixtures, which were analyzed by nano-HPLC/nano-ESI-FTICR mass spectrometry. In cases where more than one reactive functional group, e.g., amine groups of lysine residues, is present in a sequence stretch, MS/MS analysis is a prerequisite for unambiguously identifying the modified residues. MS/MS experiments revealed two lysine residues in the central alpha-helix of calmodulin as well as three lysine residues both in the C-terminal and N-terminal lobes of calmodulin to be cross-linked with one single lysine residue of the adenylyl cyclase 8 peptide. Further cross-linking studies will have to be conducted to propose a structural model for the calmodulin/peptide complex, which is formed in the absence of calcium. The combination of using isotope-labeled cross-linkers, determining the accurate mass of intact cross-linked products, and verifying the amino acid sequences of cross-linked species by MS/MS presents a convenient approach that offers the perspective to obtain structural data of protein assemblies within a few days.  相似文献   

7.
Capillary isoelectric focusing (CIEF) can provide high-resolution separations of complex protein mixtures, but until recently it has primarily been used with conventional UV detection. This technique would be greatly enhanced by much more information-rich detection methods that can aid in protein characterization. We describe progress in the development of the combination of CIEF with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry and its application to proteome characterization. Studies have revealed 400-1000 putative proteins in the mass range of 2-100 kDa from total injections of approximately 300 ng protein in single CIEF-FTICR analyses of cell lysates for both Escherichia coli (E. coli) and Deinococcus radiodurans (D. radiodurans). We also demonstrate the use of isotope labeling of the cell growth media to improve mass measurement accuracy and provide a means for quantitative proteome-wide measurements of protein expression. The ability to make such comprehensive and precise measurements of differences in protein expression in response to cellular perturbations should provide new insights into complex cellular processes.  相似文献   

8.
The patterns of gene expression, post-translational modifications, protein/biomolecular interactions, and how these may be affected by changes in the environment, cannot be accurately predicted from DNA sequences. Approaches for proteome characterization are generally based upon mass spectrometric analysis of in-gel digested two dimensional polyacrylamide gel electrophoresis (2-D PAGE) separated proteins, allowing relatively rapid protein identification compared to conventional approaches. This technique, however, is constrained by the speed of the 2-D PAGE separations, the sensitivity limits intrinsic to staining necessary for protein visualization, the speed and sensitivity of subsequent mass spectrometric analyses for identification, and the limited ability for accurate quantitative measurements based on differences in spot intensity. We are presently developing alternative approaches for proteomics based upon the combination of fast capillary electrophoresis, or other suitable chromatographic separations, and the high mass accuracy and sensitivity obtainable with unique Fourier transform ion cyclotron resonance (FTICR) mass spectrometers available at our laboratory. Several approaches are presently being pursued; one based upon the analysis of intact proteins and the second upon approaches for global protein digestion and accurate peptide mass analysis. Quantitation of protein/peptide levels are based on using two or more stable-isotope labeled versions of proteomes which are combined to obtain precise quantitation of relative protein abundances. We describe the status of our efforts towards the development of a high-throughput proteomics capability and present initial results for application to several microorganisms and discuss our efforts for extending the developed capability to mammalian proteomes.  相似文献   

9.
In proteome research, rapid and effective separation strategies are essential for successful protein identification due to the broad dynamic range of proteins in biological samples. Some important proteins are often expressed in ultra low abundance, thus making the pre-concentration procedure before mass spectrometric analysis prerequisite. The main purpose of enrichment is to isolate target molecules from complex mixtures to reduce sample complexity and facilitate the subsequent analyzing steps. The introd...  相似文献   

10.
A primary challenge in proteome measurements is to be able to detect, identify, and quantify the extremely complex mixtures of proteins. The relative abundances of interest span at least six orders of magnitude for mammalian proteomes, and this constitutes an intractable challenge for high throughput proteome studies. We have recently described a new approach, Dynamic Range Enhancement Applied to Mass Spectrometry (DREAMS), which is based upon the selective ejection of the most abundant species to expand the dynamic range of Fourier transform ion cyclotron resonanace (FTICR) measurements. The basis of our approach is on-the-fly data-dependent selective ejection of highly abundant species, followed by prolonged accumulation of remaining low-abundance species in a quadrupole external to the FTICR ion trap. Here we report the initial implementation of this approach with high efficiency capillary reverse phase LC separations and high magnetic field electrospray ionization FTICR mass spectrometry for obtaining enhanced coverage in quantitative measurements for mammalian proteomes. We describe the analysis of a sample derived from a tryptic digest of proteins from mouse B16 cells cultured in both natural isotopic abundance and 15N-labeled media. The FTICR mass spectrometric analysis allows the assignment of peptide pairs (corresponding to the two distinctive versions of each peptide), and thus provides the basis for quantiative measurements when one of the two proteomes in the mixture is perturbed or altered in some fashion. We show that implementation of the DREAMS approach allows assignment of approximately 80% more peptide pairs, thus providing quantitative information for approximately 18,000 peptide pairs in a single analysis.  相似文献   

11.
Electrospray ionization mass spectrometry is used in lipidomics studies. The present research established a top-down liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) shotgun analysis method for phospholipids (PLs) using a normal-phase column or a C30 reverse-phase column with the data-dependent MS/MS scanning mode. A normal-phase column can separate most of the major different classes of PLs. By using LC/ESI-MS/MS with a normal-phase column, approximately 50 molecular species were identified in a PL mixture from rat liver. When the reverse-phase column was used, the PLs could be separated depending on their hydrophobicity, essentially the length of their fatty acyl chains and the number of unsaturated bonds in them. The LC/ESI-MS/MS method using a C30 reverse-phase column was applied to phosphatidylcholine (PC) and phosphatidylethanolamine (PE) mixtures as test samples. Molecular species with the same molecular mass but with different pairs of fatty acyl chains were separately identified. As a result, about 60 PC and 50 PE species were identified. PLs from rat liver were subjected to LC/ESI-MS/MS using the C30 reverse-phase column and about 110 molecular species were identified. Off-line two-dimensional LC/ESI-MS/MS with the normal-phase and C30 reverse-phase columns allowed more accurate identification of molecular species by using one-dimensional C30 reverse-phase LC/ESI-MS/MS analysis of the collected fractions.  相似文献   

12.
A thin polymer microchip was coupled with a Fourier transform ion cyclotron resonance (FTICR) 9.4 T mass spectrometer and the method was optimized in negative ion mode for glycopeptide screening. The interface between the polymer microchip and FTICR mass spectrometer consists of an in-laboratory conceived and designed mounting system that exhibits robust and controllable alignment of the chip toward the inlet of the mass spectrometer. The particular attribute of the polymer chip coupled to the FTICR mass spectrometer, to achieve an increase in ionization efficiency and sensitivity under the premise of high mass accuracy of detection, is highlighted by the large number of major and minor glycopeptide structures detected and identified in highly heterogeneous mixtures obtained from urine matrices. Glycoforms expressing various saccharide chain lengths ranging from tri- to dodecasaccharide, bearing up to three sialic acid moieties, could be detected and assigned based on the accuracy of the mass measurement (average mass deviation below 6 ppm) of their molecular ions. -Thin chipESI-FTICRMS is a potent novel system for glycomic screening of complex mixtures, as demonstrated for identification of singly sialylated O-glycosylated amino acids and peptides from urine matrices, and could be considered for general applicability in the glycoanalytical field.  相似文献   

13.
An Y  Cooper JW  Balgley BM  Lee CS 《Electrophoresis》2006,27(18):3599-3608
Besides the complexity in protein samples of biological origin, probably the greatest challenge presently facing comprehensive proteome analysis is related to the large variation of protein relative abundances (>6 orders of magnitude), having potential biological significance in mammalian systems. As demonstrated in this work, transient capillary ITP/zone electrophoresis (CITP/CZE) provides selective analyte enrichment through electrokinetic stacking and extremely high resolving power toward protein and peptide mixtures. The result of the CITP process is that major components may be diluted, but trace compounds are concentrated. The on-column transition of CITP to CZE minimizes additional band broadening while providing superior analyte resolution. Online coupling of transient CITP/CZE with nano-ESI-MS allows ultrasensitive detection of trace peptides at levels of subnanomolar concentration or subfemtomole mass in complex peptide mixtures. More importantly, selective enrichment of trace peptides enables the identification and sequence analysis of low-abundance peptides co-migrated with highly abundant species at a concentration ratio of 1:500,000. The combined CITP/CZE-nano-ESI-MS system is demonstrated to be at least one to two orders of magnitude more sensitive than that attained in conventional electrophoretic and chromatographic-based proteome technologies over a wide dynamic concentration range, potentially allowing comprehensive analysis of protein profiles within a small cell population and limited tissue samples using conventional mass spectrometers. Furthermore, the speed of CITP/CZE separation and the lack of column equilibration in CITP/CZE not only improve the throughput of proteome analysis, but also facilitate its seamless integration with other separation technologies in a multidimensional protein identification platform.  相似文献   

14.
The post-genomic era and increased demands for broad proteome measurements have greatly increased the needs for protein identification. We describe a strategy that uses accurate mass measurements and partial amino acid content information to unambiguously identify intact proteins, and show its initial application to the proteomes of Escherichia coli and Saccharomyces cerevisiae. Proteins were extracted from the organisms grown in minimal medium or minimal medium to which isotopically labeled leucine (Leu-D(10)) had been added. The two protein extracts were mixed and analyzed by capillary isoelectric focusing (CIEF) coupled with Fourier transform ion cyclotron resonance mass spectrometry (FTICR). The incorporation of the isotopically labeled residue has no effect on the CIEF separation of proteins, and both isotopically labeled and unlabeled versions of specific proteins are observed within the same mass spectrum. The difference in the mass of the unlabeled and labeled proteins is used to determine the number of Leu residues present in a particular protein. Proteins can then often be unambiguously identified based on their accurately determined molecular mass and the additional constraint provided by number of Leu residues. The identities of proteins were further confirmed by repeating CIEF/FTICR measurements with samples that contain other isotopically labeled amino acid residues (e.g. His, Arg, Ile, Phe, Lys). A theoretical study of the amino acid composition (for a difference in the amino acid sequence) showed the constraints needed in order to identify the protein unambiguously. Additionally, the mass differences between the predicted and the experimental accurate mass measurement provide insights into the nature of simple post-translational modifications.  相似文献   

15.
Mao X  Wei J  Niu M  Zhou L  Wang X  Tong W  Qin W  Zhang Y  Qian X 《色谱》2012,30(2):170-177
建立了依赖色谱保留时间的智能化选择反应监测质谱方法,并与非依赖色谱保留时间的智能化选择反应监测质谱分析方法对不同体系(牛血清白蛋白酶切物、6种标准蛋白质混合物酶切物、腾冲嗜热菌蛋白提取液酶切物)的分析结果进行了系统比较。结果表明,引入色谱保留时间后的智能化选择反应监测质谱方法能够显著提高肽段及蛋白质的鉴定量,并且在复杂体系(如腾冲嗜热菌蛋白提取液酶切物)中效果尤为明显,鉴定到的肽段及蛋白质的覆盖率可分别达到目标肽段和蛋白质数量的89.62%和92.41%,并且灵敏度高、重复性好,能够实现对质荷比相同但保留时间有差异的肽段的准确鉴定。该方法将在复杂生物样本目标蛋白质组高通量、高灵敏度的鉴定、验证和确认中发挥独特作用。  相似文献   

16.
We demonstrate that the semi-quantitative information in matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectra of tryptically digested protein mixtures can, via a systematic statistical approach, be utilized for the identification of a protein present in different concentrations in two samples. Multiple mass spectra were acquired from a series of tryptically digested test samples in which the concentration of one protein was varied and the concentrations of three other proteins were held constant. The mass spectra were subjected to soft independent modeling of class analogy (SIMCA) analysis assuming that spectra originating from two different samples belonged to different data classes. The SIMCA analysis yielded information on which individual m/z values discriminate between two classes. Protein identification by proteolytic peptide mass fingerprinting was performed with different numbers of mass values in the fingerprint according to the discriminatory information, beginning with the mass corresponding to the best discrimination, followed by the best together with the second best, etc. By using the Probity algorithm, which computes the statistical significance of each identification result, we demonstrate that the first protein identified at a desired significance level (0.001) is the protein that was present in a different concentration in the two samples. Differential analysis of expression is often performed by comparing 2D-gel-spot intensities followed by mass spectrometric identification of the respective protein in each spot that differs. The method presented here has the potential to allow identification of the protein component that differs in cases where a gel-spot is poorly resolved and contains several proteins.  相似文献   

17.
Mass spectrometry (MS) together with genome database searches serves as a powerful tool for the identification of proteins. In proteome analysis, mixtures of cellular proteins are usually separated by sodium dodecyl sulfate (SDS) polyacrylamide gel-based two-dimensional gel electrophoresis (2-DE) or one-dimensional gel electrophoresis (1-DE), and in-gel digested by a specific protease. In-gel protein digestion is one of the critical steps for sensitive protein identification by these procedures. Efficient protein digestion is required for obtaining peptide peaks necessary for protein identification by MS. This paper reports a remarkable improvement of protein digestion in SDS polyacrylamide gels using an acid-labile surfactant, sodium 3-[(2-methyl-2-undecyl-1,3-dioxolan-4-yl)methoxy]-1-propanesulfonate (ALS). Pretreatment of gel pieces containing protein spots separated by 2-DE with a small amount of ALS prior to trypsin digestion led to increases in the digested peptides eluted from the gels. Consistently, treatment of gel pieces containing silver-stained standard proteins and those separated from tissue extracts resulted in the detection of increased numbers of peptide peaks in spectra obtained by matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOFMS). Hence the present protocol with ALS provides a useful strategy for sensitive protein identification by MS.  相似文献   

18.
High-resolution Fourier transform ion cyclotron resonance (FTICR) mass spectrometry was developed and applied to the proteome analysis of bronchoalveolar lavage fluid (BALF) from a patient with pulmonary alveolar proteinosis. With use of 1-D and 2-D gel electrophoresis, surfactant protein A (SP-A) and other surfactant-related lung alveolar proteins were efficiently separated and identified by matrix-assisted laser desorption/ionization FTICR mass spectrometry . Low molecular mass BALF proteins were separated using a gradient 2-D gel. An efficient extraction/precipitation system was developed and used for the enrichment of surfactant proteins. The result of the BALF proteome analysis show the presence of several isoforms of SP-A, in which an N-non-glycosylierte form and several proline hydroxylations were identified. Furthermore, a number of protein spots were found to contain a mixture of proteins unresolved by 2-D gel electrophoresis, illustrating the feasibility of high-resolution mass spectrometry to provide identifications of proteins that remain unseparated in 2-D gels even upon extended pH gradients. Yu Bai and Dmitry Galetskiy both contributed equally to this work.  相似文献   

19.
We report here a method for the identification of free or blocked N-terminal peptide of in-gel digested isolated proteins. The primary amino groups of the gel-entrapped protein are blocked with normal acetic or succinic anhydride, and the protein is digested with a high-specificity protease. The generated peptides are treated with an equimolar mixture of normal and deuterated acetic anhydride. Upon mass spectrometric analysis internal peptides display a complex isotopic ion distribution while the N-terminal peptide shows a normal isotopic ion distribution. The procedure was applied to the identification of the N-terminus of individual and protein mixtures isolated by sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE).  相似文献   

20.
HPLC procedures using conventional C18 columns are usually used to separate simple and complex lipid mixtures but these methods of separation remain often laborious and very slow. Here, monolithic columns were successfully applied to separate lipids - radiolabelled fatty acid mixtures and individual phosphatidylcholine (PC) molecular species. For that, isocratic elution was performed using two Chromolith™ Performance RP-18e columns connected in series. Detection was achieved by online measurement of radioactivity for radiolabelled fatty acids and by UV absorbance at 205 nm for PC molecular species. The performances of such silica rods were compared to conventional reverse-phase silica columns. Monolithic stationary phase separated radiolabelled fatty acids and PC molecular species two times and four times faster, respectively. In each analysis, monolithic columns allowed better separation efficiency per unit of time, with lower inlet pressure. The main advantages of this method for lipid separation are that, under isocratic conditions, it is simpler and much faster, while remaining accurate and selective when compared to conventional methods. Therefore, monolithic columns may represent a powerful tool for the near future in the field of lipidomics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏