首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, rapid and environment‐friendly technique of single‐drop liquid‐phase microextraction has been developed for the determination of sulfonamides in environmental water. Several important parameters including stirring rate, extraction solvent, extraction pH, salinity and extraction time were optimized to maximize the extract efficiency. Extraction solvent 1‐octyl‐3‐methylimidazolium hexafluorophosphate [C8MIM][PF6] ionic liquid showed better extraction efficiency than 1‐butyl‐3‐methylimidazolium hexafluorophosphate [C4MIM][PF6] and 1‐octanol. The optimum experimental conditions were: pH, 4.5; sodium chloride content, 36% w/v; extraction time, 20 min. This method provided low detection limits (0.5–1 ng/mL), good repeatability (the RSD ranging from 4.2 to 9.9%, n=5) and wide linear range (1–1500 ng/mL), with determination coefficients (r2) higher than 0.9989 for all the target compounds. Real sample analysis showed relative recoveries between 63.5 and 115.8% for all the target compounds.  相似文献   

2.
A simple and efficient method, ionic liquid-based dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV), has been applied for the extraction and determination of some antioxidants (Irganox 1010, Irganox 1076 and Irgafos 168) in water samples. The microextraction efficiency factors were investigated and optimized: 1-hexyl-3-methylimidazolium hexafluorophosphate [C(6)MIM][PF(6)] (0.06 g) as extracting solvent, methanol (0.5 mL) as disperser solvent without salt addition. Under the selected conditions, enrichment factors up to 48-fold, limits of detection (LODs) of 5.0-10.0 ng/mL and dynamic linear ranges of 25-1500 ng/mL were obtained. A reasonable repeatability (RSD≤11.8%, n=5) with satisfactory linearity (r(2)≥0.9954) of the results illustrated a good performance of the presented method. The accuracy of the method was tested by the relative recovery experiments on spiked samples, with results ranging from 85 to 118%. Finally, the method was successfully applied for determination of the analytes in several real water samples.  相似文献   

3.
A method for the rapid pretreatment and determination of bisphenol A in water samples based on vortex‐assisted liquid–liquid microextraction followed by high‐performance liquid chromatography with fluorescence detection was proposed in this paper. A simple apparatus consisting of a test tube and a cut‐glass dropper was designed and applied to collect the floating extraction drop in liquid–liquid microextraction when low‐density organic solvent was used as the extraction solvent. Solidification and melting steps that were tedious but necessary once the low‐density organic solvent used as extraction solvent could be avoided by using this apparatus. Bisphenol A was selected as model pollutant and vortex‐assisted liquid–liquid microextraction was employed to investigate the usefulness of the apparatus. High‐performance liquid chromatography with fluorescence detection was selected as the analytical tool for the detection of bisphenol A. The linear dynamic range was from 0.10 to 100 μg/L for bisphenol A, with good squared regression coefficient (r2 = 0.9990). The relative standard deviation (n = 7) was 4.7% and the limit of detection was 0.02 μg/L. The proposed method had been applied to the determination of bisphenol A in natural water samples and was shown to be economical, fast, and convenient.  相似文献   

4.
建立了液-液-液微萃取与高效液相色谱联用技术快速分析尿样中美沙酮的方法.对有机溶剂种类、体积、样品溶液的pH值、萃取时间、搅拌速度进行了优化.方法的线性范围为0.05~10 mg/L,检出限为0.025 mg/L,相对标准偏差小于5%.  相似文献   

5.
A new method was developed for determination of methomyl in water samples by combining a dispersive liquid-liquid microextraction (DLLME) technique with HPLC-variable wavelength detection (VWD). In this extraction method, 0.50 mL of methanol (as dispersive solvent) containing 20.0 microL of tetrachloroethane (as extraction solvent) was rapidly injected by syringe into a 5.00-mL water sample containing the analyte, thereby forming a cloudy solution. After phase separation by centrifugation for 2 min at 4000 rpm, the enriched analyte in the settled phase (8 +/- 0.2 microL) was at the bottom of the conical test tube. A 5.0-microL volume of the settled phase was analyzed by HPLC-VWD. Parameters such as the nature and volume of the extraction solvent and the dispersive solvent, extraction time, and the salt concentration were optimized. Under the optimum conditions, the enrichment factor could reach 70.7 for a 5.00-mL water sample and the linear range, detection limit (S/N = 3), and precision (RSD, n = 6) were 3-5000 ng/mL, 1.0 ng/mL, and 2.6%, respectively. River and lake water samples were successfully analyzed by the proposed method. Comparison of this method with solid-phase extraction, solid-phase microextraction, and single-drop microextraction, indicates that DLLME combined with HPLC-VWD is a simple, fast, and low-cost method for the determination of methomyl, and thus has tremendous potential in trace analysis of methomyl in natural waters.  相似文献   

6.
Liquid-liquid-liquid microextraction (LLLME) in combination with HPLC and UV detection has been used as a sensitive method for the determination of ephedrine in urine samples. Extraction process was performed in a homemade total glass vial without using a Teflon ring, usually employed. Ephedrine was first extracted from 3.5 mL of urine sample (pH 12) into a microfilm of toluene/benzene (50:50). The analyte was subsequently back extracted into an acidic microdrop solution (pH 2) suspended in the organic phase. The extract was then injected into the HPLC system directly. An enrichment factor of 137 along with a good sample clean-up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 0.01-50 mg/L with regression coefficient corresponding to 0.998. The LODs and LOQs, based on a S/N of 3 and 10, were 5 and 10 microg/L, respectively. The method was eventually applied for the determination of ephedrine in urine sample after oral administration of 5 mg single dose of drug.  相似文献   

7.
应用可忽略耗损固相微萃取与高效液相色谱联用技术测定了环境水样中双酚A的自由溶解态浓度。为了获得高的灵敏度并减小环境因素(如温度和搅拌等)的影响,采用商品化固相微萃取纤维CW/TPR进行平衡采样。在环境水样常见pH(5~8)、缓冲容量(5~200mmol/L)和盐度(0~500mmol/L)条件下,4h可以达到萃取平衡。100mL样品足以避免样品耗损。以配制在250mmol/L NaCl和125mmol/L磷酸盐溶液(pH6.4)中的双酚A标准溶液进行校准,可以将缓冲液(0~200mmol/L)、盐度(0~500mmol/L)和pH(5.7~8.5)的影响控制在15%偏差范围以内。如需更准确的测定,也可以对样品pH值的影响加以校正。pH为6.4时,方法的线性范围为0.1~250μg/L,检出限为0.03μg/L,相对标准偏差(5μg/L,n=3)为1.1%。采用本方法测定了污水处理厂排水口的双酚A的自由溶解态浓度。  相似文献   

8.
A new method, which involves liquid-phase microextraction (LPME) followed by high performance liquid chromatography (HPLC) with diode array detector (DAD), was developed to determine phoxim in water sample. Experimental parameters affecting the extraction efficiency, such as extraction solvent, solvent volume, agitation speed of the sample and extraction time were investigated. Under the optimal extraction conditions, phoxim was found to yield a good linear calibration curve in the concentration range from 0.01 to 5 μg mL−1. The limit of detection (LOD) is 10 ng mL−1, and relative standard deviation (RSD) at the 100 ng mL−1 levels is 8.4%. Lake water and tap water samples were successfully analyzed using the proposed method.  相似文献   

9.
An ionic liquid foam floatation coupled with ionic liquid dispersive liquid–liquid microextraction method was proposed for the extraction and concentration of 17‐α‐estradiol, 17‐β‐estradiol‐benzoate, and quinestrol in environmental water samples by high‐performance liquid chromatography with fluorescence detection. 1‐Hexyl‐3‐methylimidazolium tetrafluoroborate was applied as foaming agent in the foam flotation process and dispersive solvent in microextraction. The introduction of the ion‐pairing and salting‐out agent NH4PF6 was beneficial to the improvement of recoveries for the hydrophobic ionic liquid phase and analytes. Parameters of the proposed method including concentration of 1‐hexyl‐3‐methylimidazolium tetrafluoroborate, flow rate of carrier gas, floatation time, types and concentration of ionic liquids, salt concentration in samples, extraction time, and centrifugation time were evaluated. The recoveries were between 98 and 105% with relative standard deviations lower than 7% for lake water and well water samples. The isolation of the target compounds from the water was found to be efficient, and the enrichment factors ranged from 4445 to 4632. This developing method is free of volatile organic solvents compared with regular extraction. Based on the unique properties of ionic liquids, the application of foam floatation, and dispersive liquid–liquid microextraction was widened.  相似文献   

10.
A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such as cyanazine,simazine,and atrazine in water samples.1-Octyl-3-methylimidazolium hexafluorophosphate([C8MIM][PF6]) was selected as the extraction solvent.Several experimental parameters were optimized.Under the optimal conditions,the linear range for cyanazine was in the concentration range of 0.5–80 mg/L and the linear range for simazine and atrazine was in the range of1.0–100 mg/L.The limit of detection(LOD,S/N = 3) was in the ranges of 0.05–0.06 mg/L,and the intra day and inter day precision(RSDs,n = 6) was in the ranges of 3.2%–6.6% and 4.8%–8.9%,respectively.Four real water samples were analyzed with the developed method,and the experimental results showed that the spiked recoveries were satisfactory.All these exhibited that the developed method was a valuable tool for monitoring such pollutants.  相似文献   

11.
In this paper, two methods based on organic solvent dispersive liquid-liquid microextraction (OS-DLLME) and ionic liquid dispersive liquid-liquid microextraction (IL-DLLME) coupled with high-performance liquid chromatography have been critically compared for analyzing emodin and its metabolites (aloe-emodin, anthraquinone-2-carboxylic acid, rhein, danthron, chrysophanol and physcion) in urine samples. Several important parameters influencing the extraction recoveries of DLLME were carefully optimized. Under optimal conditions, the enrichment factors (EFs) for emodin and its metabolites by OS-DLLME and IL-DLLME were within the range of 90-295 and 63-192 respectively; the relative standard deviations (RSDs, n=3) for intra-day and inter-day precision were lower than 7.2 and 8.7% by OS-DLLME, and lower than 5.7 and 6.4% by IL-DLLME; the recoveries of emodin and its metabolites were from 87.1 to 105% for OS-DLLME and from 94.8 to 103% for IL-DLLME, respectively. There were no significant deviations between the two methods for the determination of emodin and its metabolites. From the results of HPLC/UV of urine sample after DLLME, the metabolites aloe-emodin, rhein, chrysophanol and physcion were identified by comparing the retention times with the standards. From the results of HPLC/MS, anthraquinone-2-carboxylic acid and danthron as unreported metabolites of emodin were found.  相似文献   

12.
In this article, a novel and simple microextraction method, termed ionic liquid/ionic liquid dispersive liquid–liquid microextraction (IL/IL‐DLLME), has been designed and developed for the rapid enrichment and analysis of environmental pollutants. Instead of using hazardous organic solvents, two kinds of ILs, hydrophobic IL and hydrophilic IL, were used as extraction solvent and disperser solvent in IL/IL‐DLLME step, respectively. Permethrin and biphenthrin, two of the often‐used pyrethroid pesticides, were used as model compounds. Factors that may affect the enrichment efficiencies were investigated and optimized in detail. Under optimum conditions, permethrin and biphenthrin exhibited a wide linear relationship over the range 1–100 μg/L. For permethrin and biphenthrin, the precisions were 4.65–7.78%, and limits of detection were found to be 0.28 and 0.83 μg/L, respectively. Satisfactory results were achieved when the present method was applied to analyze the target compounds in real‐world water samples with spiked recoveries over the range 84.1–113.5%. All these facts indicated that IL/IL‐DLLME is a simple and rapid alternative for the enrichment and analysis of environmental pollutants and will have a wide application perspective in the future.  相似文献   

13.
Dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography (HPLC)-UV detection was applied in rat urine for the extraction and determination of tetrahydropalmatine (THP) and tetrahydroberberine (THB), both active components in Rhizoma corydalis. Various parameters affecting the extraction efficiency, such as the type and volume of extraction and dispersive solvent, pH, etc. were evaluated. Under the optimal conditions (extraction solvent: 37 μL of chloroform, dispersive solvent: 100 μL of methanol, alkaline with 100 μL of 1 mol/L NaOH, and without salt addition), the enrichment factors of THP and THB were more than 30. The extraction recoveries were 69.8-75.8% and 72.7-77.6% for THP and THB in rat urine, respectively. Both THP and THB showed good linearity in the range of 0.025-2.5 μg/mL, and the limit of quantification was 0.025 μg/mL (S/N=10, n=6). The intra-day and inter-day precision of THP and THB were <12.6%. The relative recoveries ranged from 95.5 to 107.4% and 96.8 to 100.9% for THP and THB in rat urine, respectively. The method has been successfully applied to rat urine samples. The results demonstrated that DLLME is a very simple, rapid and efficient method for the extraction and preconcentration of THP and THB from urine samples.  相似文献   

14.
利用C18固相萃取柱富集和净化水样,采用高效液相色谱分离、荧光检测建立了水中的壬基酚(NP)和双酚A(BPA)的测定方法,并成功用于污水处理厂各处理单元出水的测定。不同加标水平的NP和BPA的回收率为95.3%~98.6%.其相对标准偏差为2、5%~3.7%。  相似文献   

15.
Sudan Red pollutants have gained more attention in recent years. The present study described a simple and sensitive determination method for Sudan Red pollutants with dispersive liquid–liquid microextraction coupled to high‐performance liquid chromatography. Chlorobenzene and ethanol were used as the extraction solvent and disperser solvent, respectively. The possible parameters such as the kind of solvents, ionic strength, and sample pH that could affect the enrichment have been optimized. Under the optimal conditions, the pollutants have been well enriched and the linear ranges of Sudan Red I and II were in the range of 0.3–40 μg/L, and the linear ranges of Sudan Red III and IV were in the range of 1.2–160 μg/L. The detection limits were in the range of 0.18–0.46 μg/L, and the precisions were in the range of 3.7–5.9%. All these demonstrated that the proposed method could be a good alternative for the routine analysis of Sudan Red pollutants in water samples.  相似文献   

16.
Hollow fiber-based liquid-liquid-liquid microextraction (HF-LLLME) followed by flow injection analysis and diode array detection (FIA-DAD) was applied as a simple and sensitive quantitative method for the determination of phenazopyridine in urine and plasma samples. Flow injection system included a conventional HPLC system (without a chromatographic column) and a diode array detector. The extraction of phenazopyridine was carried out using diphenyl ether as the organic phase for filling the pores of the hollow fiber wall, and 0.1 M H(2)SO(4) solution as acceptor phase in the lumen of the fiber. The factors affecting the HF-LLLME and flow injection analysis including type of organic solvent, pH of donor phase, extraction temperature, extraction time, stirring rate, and pH of mobile phase were investigated and the optimal extraction conditions were established. With the consumption of 5 mL of sample solution, the enrichment factor was about 230. The limit of detection was 0.5 μg/L with inter- and intra-day precision being (RSD%) 6.9 and 4.9, respectively. Excellent linearity was found between 5 and 200 μg/L.  相似文献   

17.
Headspace liquid-phase microextraction (HS-LPME) has been applied to efficient enrichment of phenols such as 2-nitrophenol, 4-chlorophenol, 2,4-dichlorophenol, and 2-naphthol from water samples based on 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) as an extractant. Some parameters that may influence HS-LPME were investigated. The linear range was in the range of 0.5-100 microg/L, and the enrichment factors and repeatability (RSD, n = 6) of the proposed method were in the range of 17.2-160.7 and 5.4-8.9%, respectively. The detection limit for each analyte ranged from 0.3 to 0.5 microg/L. Complex matrices of environmental water samples had a small effect on the enrichment, and this problem could be resolved by the addition of sodium ethylene diamine tetraacetate (EDTA) into the samples. The spiked recoveries were in the range of 89.4-114.2%. All these facts demonstrated that the proposed method, with merits of low cost, simplicity, and easy operation, would be a competitive alternative procedure for the determination of such compounds at trace level.  相似文献   

18.
A novel method, dispersive liquid-liquid microextraction combined with liquid chromatography-fluorescence detection is proposed for the determination of three beta-blockers (metoprolol, bisoprolol, and betaxolol) in ground water, river water, and bottled mineral water. Some important parameters, such as the kind and volume of extraction and dispersive solvents, extraction time, pH, and salt effect were investigated and optimized. In the method, a suitable mixture of extraction solvent (60 μL carbon tetrachloride) and dispersive solvent (1 mL acetonitrile) were injected into the aqueous samples (5.00 mL) and the cloudy solution was observed. After centrifugation, the enriched analytes in the bottom CCl(4) phase were determined by liquid chromatography with fluorescence detection. Under the optimum conditions, the enrichment factors (EFs) for metoprolol, bisoprolol, and betaxolol were 180, 190, and 182, and the limits of detection (LODs) were 1.8, 1.4, and 1.0 ng L(-1) , respectively. A good linear relationship between the peak area and the concentration of analytes was obtained in the range of 3-150 ng L(-1) . The relative standard deviations (RSDs) for the extraction of 10 ng L(-1) of beta-blockers were in the range of 4.6-5.7% (n = 5). Compared with other methods, dispersive liquid-liquid microextraction is a very simple, rapid, sensitive (low limit of detection), and economical (only 1.06 mL volume of organic solvent) method, which is in compliance with the requirements of green analytical methodologies.  相似文献   

19.
RH Li  DH Liu  ZH Yang  ZQ Zhou  P Wang 《Electrophoresis》2012,33(14):2176-2183
A novel method based on the combination of microemulsion electrokinetic chromatography (MEEKC) and vortex‐assisted surfactant‐enhanced‐emulsification liquid–liquid microextraction (VSLLME) was developed for the determination of five triazine herbicides (simazine, atrazine, ametryn, prometryn, and terbutryn) in water samples. The five triazine herbicides were baseline separated by using the microemulsion buffer containing a 10 mmol/L borate buffer at pH 9.5, 2.5% (w/v) SDS as surfactant, 0.8% (w/v) ethyl acetate as oil phase, and 6.0% (w/v) 1‐butanol as cosurfactant. The optimum extraction conditions of VSLLME were as follows: 100 μL chloroform was used as extraction solvent, 5.0 × 10?5 mol/L Tween‐20 was chosen as the surfactant to enhance the emulsification, and the extraction process was carried out by vortex mixing for 3 min. Under these optimum experimental conditions, the calibration curve was linear in the range of 2.0–200.0 ng/mL, with the correlation coefficients (r2) varying from 0.9927 to 0.9958. The detection limits of the method varied from 0.41 to 0.62 ng/mL. The purposed method was applied to the determination of five triazine herbicides in real water samples, and the recoveries were between 80.6 and 107.3%.  相似文献   

20.
Three-phase hollow fiber microextraction technique combined with high performance liquid chromatography-ultra violet (HPLC-UV) was applied for the extraction and determination of gabapentin in biological fluids. Gabapentin (GBP) was derivatized with 1-fluoro-2,4-dinitrobenzene, as a UV absorbent agent in borate buffer (pH 8.2) before extraction. The derivative product of GBP was extracted from the 8.5 mL of acidic solution (source phase) into an organic phase (dihexyl ether) impregnated in the pores of a hollow fiber and finally back-extracted into 24 μL of the basic solution (pH 9.1) located inside the lumen of the hollow fiber (receiving phase). The extraction took place due to pH gradient between the inside and outside of the hollow fiber membrane. In order to achieve maximum extraction efficiency, different parameters affecting the extraction conditions were optimized. Under the optimized conditions, preconcentration factor of 95 and detection limit (LOD) of 0.2 μg L−1 were obtained. The calibration graph was linear within the range of 0.6-5000 μg L−1. Finally, the feasibility of the proposed method was successfully confirmed by extraction and determination of GBP in human urine and plasma samples in the range of microgram per liter and suitable results were obtained (RSDs < 6.3%).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号