首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work reports a surface ion imprinting strategy in electropolymerized microporous poly(2-mercaptobenzothiazole) (MPMBT) films at the surface of glassy carbon electrode (GCE) for the electrochemical detection of Hg(II). The Hg(II)-imprinted MPMBT/GCE exhibits larger binding to functionalized capacity, faster binding kinetics and higher selectivity to template Hg(II) due to their high ratio of surface-imprinted sites, larger surface-to-volume ratios, the complete removal of Hg(II) templates and larger affinity to Hg(II). The square wave anodic stripping voltammetry (SW ASV) response of the Hg(II)-imprinted MPMBT/GCE to Hg(II) is ca. 3.0 and 5.9 times larger than that at the direct imprinted poly(2-mercaptobenzothiazole) modified GCE and non-imprinted MPMBT/GCE sensor, respectively; and the detection limit for Hg(II) is 0.1 nM (which is well below the guideline value given by the World Health Organization). Excellent wide linear range (1.0–160.0 nM) and good repeatability (relative standard deviation of 2.5%) were obtained for Hg(II). The interference experiments showed that mercury signal was not interfered in the presence of Pb(II), Cd(II), Zn(II), Cu(II) and Ag(I), respectively. These values, particularly the high sensitivity and excellent selectivity compared favorably with previously reported methods in the area of electrochemical Hg(II) detection, demonstrate the feasibility of using the prepared Hg(II)-imprinted MPMBT/GCE for efficient determination of Hg(II) in aqueous environmental samples.  相似文献   

2.
A fundamental study of the application of cumin biomass in the recovery of Cu and Zn metal ion uptake from food and drinks is carried out at different pH's and at fixed ionic strength. The chemical characteristics of protein in cumin seeds were investigated. Results showed that cumin contains 18.25% crude protein, which includes 18 amino acids. The main reactive groups on protein cumin are amino and carboxylic groups of dicarboxylic amino acids, leading to a pH-dependent charge. Therefore, the cumin surface is considered as a heterogeneous system. To describe protonation behavior in a heterogeneous cumin biomass (cumin/0.1 M NaNO(3)) system, acid-base titrations have been performed with conductometric and potentiometric titration. Measurement of the reactivity of cumin surface in the adsorption of Cu and Zn metal ions and determination of metal binding at different pH's were also carried out. To solve broad and ill-defined titration curves, a simplified version of nonideal competitive analysis (NICA) by Plette et al.) was applied. The results show that the sorption of the bivalent metal ions onto the whole surface of cumin could be attributed to a monodentate binding to one site mainly carboxylic-type site.  相似文献   

3.
《Arabian Journal of Chemistry》2020,13(12):8671-8683
A fully functionalised calix[4]pyrrole derivative, namely, meso-tetramethyl-tetrakis[(diethylthiocarbamoyl)phenoxy] calix[4]-pyrrole, 1 has been synthesised and structurally characterised. Its complexing properties with metal cations in acetonitrile were investigated with particular emphasis on the thermodynamics of these systems. These data and those previously reported for a partially functionalised calix[4]arene based receptor, 5,11,17,23-tetra-tert-butyl[25,27 bis(diethylthiocarbamoyl)oxy]calix[4]arene, 2 were used to, i) further corroborate their use to predict the selectivity coefficients of carrier mediated mercury (II) ion selective electrodes (ISEs) and ii) to obtain approximate stability constant data from selectivity coefficients. The optimum working conditions of both electrodes were determined. It is shown that while the ISE based on 1 is characterised by a wider linear range and a lower mercury (II) detection than the one based on 2, the latter has the advantage of lower interference of other metal cations due to the much lower stability constants of bivalent cations relative to Hg(II). The response characteristics of these electrodes are compared with those found in the literature. SEM micrographs along with EDX spectra of the PVC membranes containing ionophore 1 or 2 unloaded and loaded with Hg(II) are reported.  相似文献   

4.
Ashrafi AM  Vytřas K 《Talanta》2011,85(5):2700-2702
A new procedure was elaborated to determine mercury(II) using an anodic stripping square-wave voltammetry at the antimony film carbon paste electrode (SbF-CPE). In highly acidic medium of 1 M hydrochloric acid, voltammetric measurements can be realized in a wide potential window. Presence of cadmium(II) allows to separate peaks of Hg(II) and Sb(III) and apparently catalyses reoxidation of electrolytically accumulated mercury, thus allowing its determination at ppb levels. Calibration dependence was linear up to 100 ppb Hg with a detection limit of 1.3 ppb. Applicability of the method was tested on the real river water sample.  相似文献   

5.
Polyurethane foam functionalized with 8-hydroxyquinoline has been prepared by coupling the foam matrix with 8-hydroxyquinoline (oxine) through an azo spacer. The oxine-bonded foam (Ox PUF) was characterized by use of different tools (UV–Vis spectra, IR spectra, density, and stability). Ox PUF was found to be very suitable for separation and preconcentration of trace metals, e.g. Zn(II), Cd(II), and Hg(II) ions, from wastewater in the pH ranges 2–12, 9–12, and 3–6, respectively. Various conditions influencing the sorption of these metal ions on to Ox PUF were optimized. Extraction of the metal ions was accomplished in 15 to 20 min. Study of the variation of the sorption of the tested metal ions with temperature yielded average values for H, S, and G of 41.99, 158.23, and –5.1 kJ mol–1, respectively. The capacities of the foam material were 0.27, 0.16, and 0.09 mmol g–1 for Zn(II), Cd(II), and Hg(II), respectively. Preconcentration factors >50 were achieved (RSD6.18). The quantitative results were obtained from experiments performed using certified reference materials.  相似文献   

6.
Brett CM  Fungaro DA 《Talanta》2000,50(6):1223-1231
Mercury-thin film electrodes coated with a thin film of poly(ester sulphonic acid) (PESA) have been investigated for application in the analysis of trace heavy metals by square wave anodic stripping voltammetry using the batch injection analysis (BIA) technique. Different polymer dispersion concentrations in water/acetone mixed solvent are investigated and are characterised by electrochemical impedance measurements on glassy carbon and on mercury film electrodes. The influence of electrolyte anion, acetate or nitrate, on polymer film properties is demonstrated, acetate buffer being shown to be preferable for stripping voltammetry applications. Although stripping currents are between 30 and 70% less at the coated than at bare mercury thin film electrodes, the influence of model surfactants on stripping response is shown to be very small. The effect of the composition of the modifier film dispersion on calibration plots is shown; however, detection limits of around 5 nM are found for all modified electrodes tested. This coated electrode is an alternative to Nafion-coated mercury thin film electrodes for the analysis of trace metals in complex matrices, particularly useful when there is a high concentration of non-ionic detergents.  相似文献   

7.
The performance of carbon electrodes depends on the surface pretreatment methods. An exclusively cathodically pretreated glassy carbon electrode (GCE) shows very good activity towards monomeric molybdate(VI) ion adsorption and its reduction. X-ray photoelectron spectroscopy studies reveal the creation of >C–O– surface groups on cathodisation. A strong interaction between the Mo(VI) ion and these >C–O– surface groups with the formation of Mo(V) is responsible for the activation of the cathodically pretreated GCE surface. Received: 5 January 1998 / Accepted: 10 January 1999  相似文献   

8.
Fujiyoshi R  Katayama M 《Talanta》1995,42(12):1931-1935
Metal exchange reactions of acetylacetonate complexes with Cd(II), Cu(II) and Zn(II) ions were investigated by using cadmium and copper ion selective electrodes. Changes in the electrode potential and pH of the solutions were monitored upon adding the pertinent metal Zn(II) of the acetylacetonate (AA) complexes. In the reverse system in which a stable Cu-AA complex exists in the solution prior to adding a secondary metal ion (Cd(II) or Zn(II)), no Cu(II) was replaced by either ion. In the systems containing Cd(II) and Zn(II) as a complexed form with AA or as free ions, the exchange reactions were not explained by considering the equilibrium stability constants of the Cd-AA and Zn-AA complexes.  相似文献   

9.
Mercury(I) chloride disproportionates to mercury metal and bis(organothiolato)mercury(II) in the presence of some thiols in good yields. The products were analyzed by means of 1H?NMR and gas chromatographic–mass spectrometry (GC/MS), which indicated that the complexes are monomers in the gas phase and decomposed at elevated temperature to mercury(0) and corresponding disulfides.  相似文献   

10.
Electrochemical detection of Hg(II) using a electropolymerized ion imprinting poly(2-mercaptobenzothiazole) films at the surface of gold nanoparticles/single-walled carbon nanotube nanohybrids modified glassy carbon electrode (PMBT/AuNPs/SWCNTs/GCE) is described for the first time. The Hg(II)-imprinted PMBT/AuNPs/SWCNTs/GCE sensor exhibits larger binding to functionalized capacity, larger affinity, faster binding kinetics and higher selectivity to template Hg(II). The differential pulse anodic stripping voltammetry (DPASV) response of the Hg(II)-imprinted PMBT/AuNPs/SWCNTs/GCE sensor to Hg(II) is ca. 3.7- and 10.5-fold higher than that at the non-imprinted PMBT/AuNPs/SWCNTs/GCE and the imprinted PMBT/AuNPs/GCE, respectively, and the detection limit for Hg(II) is 0.08 nM (S/N = 3, which is well below the guideline value given by the World Health Organization) and a sensitivity of 0.749 μA nM−1 was obtained. Excellent wide linear range (0.4–96.0 nM) and good repeatability (relative standard deviation of 2.6%) were obtained for Hg(II). The interference experiments show that Ag(I), Pb(II), Cd(II), Zn(II) and Cu(II) had little or no influence on the Hg(II) signal. These values, particularly the high sensitivity and excellent selectivity in contrast to the values reported previously in the area of electrochemical Hg(II) detection, demonstrate the analytical performance of the Hg(II)-imprinted PMBT/AuNPs/SWCNTs/GCE toward Hg(II) is superior to the existing electrodes and could be used for efficient determination of Hg(II) in natural water samples.  相似文献   

11.
The synthesis, crystal structure and magnetic properties of a novel diamagnetic metal complex containing thiazole-substituted nitronyl nitroxide radicals, [HgCl2(NIT2-thz)2] (NIT2-thz?= 2-(2′-thiazole)-4,4,5,5-tetramethylimidazoline-1-oxyl-3-oxide), is reported. The mercury(II) ion has distorted tetrahedral coordination involving two chloride atoms and two thiazole nitrogen atoms. Magnetic susceptibility data show that there are intramolecular antiferromagnetic interactions between the radicals in the complex.  相似文献   

12.
Glassy carbon electrodes modified with (5-amino-1,10-phenanthroline)bis(bipyridine)ruthium(II) chloride hydrate, [(bpy)2Ru(5-phenNH2)]Cl2·H2O, are shown to oxidize hydrazine with excellent sensitivity. The presence of an amine group on the ruthenium complex facilitates electropolymerization onto the electrode surface. Using cyclic voltammetry, a large catalytic current is observed upon oxidation of hydrazine in phosphate buffer (pH 5.0), compared to the current obtained from the ruthenium-modified electrode with no hydrazine present. The sensitivity of cyclic voltammetry is sufficient for obtaining a linear calibration curve for hydrazine over the range of 10−5 to 10−2 M. Hydrodynamic amperometry was used to determine the working potential for flow injection analysis. The limit of detection for hydrazine was determined to be 8.5 μM using FIA. The thickness of these films was shown to increase linearly with the number of electropolymerization cycles, in the range of 1000-2500 nm for 5-20 cycles, respectively, using Rutherford backscattering spectrometry (RBS). RBS analysis also suggests that the film is multilayered with the outermost layers containing a high ruthenium concentration, followed by layers where the concentration of ruthenium decreases linearly and approaches zero at the electrode surface.  相似文献   

13.
Lin YW  Liu CW  Chang HT 《Talanta》2011,84(2):324-329
We have developed a fluorescence technique for the detection of Hg2+ and Pb2+ ions using polythymine (T33)/benzothiazolium-4-quinolinium dimer derivative (TOTO-3) and polyguanine (G33)/terbium ions (Tb3+) conjugates, respectively. Hg2+ ions induce T33 to form folded structures, leading to increased fluorescence of the T33/TOTO-3 conjugates. Because Pb2+ ions compete with Tb3+ ions to form complexes with G33, the extent of formation of the G33-Tb3+ complexes decreases upon increasing the Pb2+ concentration, leading to decreased fluorescence at 545 nm when excited at 290 nm. To minimize interference from Hg2+ ions during the detection of Pb2+ ions, we conducted two-step fluorescence measurements; prior to addition of the G33/Tb3+ probe, we recorded the fluorescence of a mixture of the T33/TOTO-3 conjugates and Hg2+ ions. The fluorescence signal obtained was linear with respect to the Hg2+ concentration over the range 25.0-500 nM (R2 = 0.99); for Pb2+ ions, it was linear over the range 3.0-50 nM (R2 = 0.98). The limits of detection (at a signal-to-noise ratio of 3) for Hg2+ and Pb2+ ions were 10.0 and 1.0 nM, respectively. Relative to other techniques for the detection of Hg2+ and Pb2+ ions in soil and water samples, our present approach is simpler, faster, and more cost-effective.  相似文献   

14.
The synthesis and use of nitrogen-containing copolymers for anchoring Ru(II) and Rh(I) species is described. The supported species are effective as catalysts for the decomposition of H2O2 in aqueous medium at neutral pH. The polymers as well as the supported catalysts have been characterised by physical and chemical methods. The effects of [H2O2], catalyst loading and pH of the medium on the rate of decomposition have been studied. Suitable mechanisms have been proposed to account for the kinetics. Recycling efficiencies of the catalysts are found to be good.  相似文献   

15.
A new fluorogenic calix[4]arene containing one pendent N-dansylcarboxamide group has been synthesized. The ligand demonstrates selective optical recognition of Tl+ and Hg2+ in solvent extraction from aqueous solutions with high content of Na+. Complexation of Tl+ and Hg2+ produces contrasting changes in the fluorescence spectrum of this sensor. Partial cone is the dominant calixarene conformation in the complex with Tl+.  相似文献   

16.
Neupane LN  Thirupathi P  Jang S  Jang MJ  Kim JH  Lee KH 《Talanta》2011,85(3):1566-1574
Fluorescent sensor (DMH) based on dipeptide was efficiently synthesized in solid phase synthesis. The dipeptide sensor shows sensitive response to Ag(I), Hg(II), and Cu(II) among 14 metal ions in 100% aqueous solution. The fluorescent sensor differentiates three heavy metal ions by response type; turn on response to Ag(I), ratiometric response to Hg(II), and turn off detection of Cu(II). The detection limits of the sensor for Ag(I) and Cu(II) were much lower than the EPA's drinking water maximum contaminant levels (MCL). Specially, DMH penetrated live cells and detected intracellular Ag+ by turn on response. We described the fluorescent change, binding affinity, detection limit for the metal ions. The study of a heavy metal-responsive sensor based on dipeptide demonstrates its potential utility in the environment field.  相似文献   

17.
Chelating selectivity and capacity of silica functionalized 2- and 4-aminothiophenoles (2-ASP-[silica] and 4-ASP-[silica]) toward mercury, lead, and cadmium ions in aqueous medium are studied. In this comparative study, the three metal ions were allowed to interact individually and simultaneously with two aminothiophenol (ASP) derivatives namely, 2- and 4-ASP once as free chelates in solution and secondly as immobilized chelates on silica. Upon individually or simultaneously interacting the three metal ions with 4-ASP-[silica], Hg(II) ions are preferentially adsorbed where 100% of Hg(II) is removed compared to 83.0% of Pb(II) and 76% of Cd(II) ions. In solution, Hg(II) ions are found to be preferentially adsorbed by 2-ASP when compared to 4-ASP. Whereas, anchoring 4-ASP to a silica surface via amide linkage provides a significant enhancement in selectivity and extent of chelation toward Hg(II) over Cd(II) and Pb(II) ions. In the case of 4-ASP-[silica], the existence of a free SH group allows an easy-accessible and strain-free binding site for the incoming Hg(II) ions. Whereas, in 2-ASP-[silica], the SH group is sterically hindered due to proximity to the point of attachment with the surface. As a result, 2-ASP-[silica] showed less potential for Hg(II) binding compared to the modified analogue, 4-ASP-[silica] with less chelation extent observed in solution compared to that observed at the surface.  相似文献   

18.
A rapid,sensitive,selective and reliable strip assay based on DNA-functionalized gold nanoparticles for Hg2+ detection has been developed,with a detection limit 5 nmol/L.The measurement principle was based on thymine-Hg2+-thymine(T-Hg2+-T) coordination chemistry and streptavidin-biotin interaction.The major advantages of this assay are that results can be read visually without any instrument in less than 10 min and that it does not require any sample pretreatment.  相似文献   

19.
Summary New Cr(III), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), and Pb(II) chelates of the Schiff base derived from isatin witho-phenylenediamine have been synthesized and characterized on the basis of elemental analyses, electronic, IR and1H NMR spectra, and also by aid of molar conductivity and magnetic moment measurements. It has been found that the Schiff base behaves as ONNO tetradentate dibasic ligand forming chelates with 1:1 (metal:ligand) stoichiometry. Square planar environment is suggested for nickel(II) chelate. All the metal chelates show non-electrolytic behaviour.
Metallchelate einiger Übergangs- und Nichtübergangsmetallionen mit Isatin-o-Phenylendiamin-Schiff-Basen
Zusammenfassung Es wurden neue Chelate von Cr(III), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) und Pb(II) mit Schiff-Basen aus Isatin undo-Phenylendiamin hergestellt und mittels Elementaranalysen, Elektronen-, IR- und1H-NMR-Spektroskopie, sowie durch Messung der molaren Leitfähigkeit und der magnetischen Momente charakterisiert. Es wurde festgestellt, daß sich die Schiff-Base als vierzähniger zweibasischer ONNO-Ligand verhält, wobei 1:1-stöchiometrische Metall:Ligand-Komplexe gebildet werden. Für das Nickel(II)-Chelat wird eine quadratisch-planare Geometrie vorgeschlagen. Alle untersuchten Metallchelate zeigen ein nicht-elektrolytisches Verhalten.
  相似文献   

20.

Several preparative routes to bis[N(substituted-phenyl) 4-nitro-thiobenzamidato] mercury(II) complexes are presented, including the reaction of mercury(II) oxide, fluoride, chloride, bromide, cyanide, acetate, and nitrate with N(substituted-phenyl) 4-nitro-thiobenzamide derivatives. 1 H-NMR, Raman, and IR measurements confirmed the complexation of mercury to sulphur.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号