首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Relatively longer liver technetium tracers such as95mTc (61 d) are useful for the development, evaluation and comparison of new technetium complexes for eventual development of99mTc radiopharmaceuticals. The feasibility of producing96Tc (4.35 d) and95mTc (61 d) was studied by the alpha bombardment of pure Nb targets (93Nb-100%).96Tc was obtained in a yield of 30 Ci/Ah using 16 MeV alphas, but it contained significant activity of95Tc (20 h) Relatively pure96Tc and95mTc was produced in yields of 18 Ci/Ah and about 1 Ci/Ah respectively with alphas of suitable energy and after allowing for suitable cooling periods after the end of bombardment (EOB).  相似文献   

2.
The reaction of the tetranuclear trimethylacetate complex Co4(3-OH)2(-OOCCMe3)4(2-OOCCMe3)2(EtOH)6 with pyridine in acetonitrile was studied. Two new compounds, viz., the hexanuclear cobalt(ii) complex Co6py4(3-OH)2(-OOCCMe3)10 (25% yield) and the unusual ionic compound [Co3py3(3-O)(-OOCCMe3)6]+[Co4py(4-O)(-OOCCMe3)7] (5% yield), were prepared. The structures of the new compounds were established by X-ray diffraction analysis.  相似文献   

3.
Co-thermolysis of the tetranuclear trimethylacetate clusters M4(3-OH)2(OOCCMe3)6(HOEt)6 (M = Co or Ni; the reagent ratio was 1 : 1) in decalin (2 h, 170 °C) afforded the octanuclear heterometallic cluster Co6Ni2(4-O)2(2-OOCCMe3)6(3-OOCCMe3)6, which exhibits ferromagnetic properties at 10—8 K.  相似文献   

4.
Summary Laser microprobe mass analysis (LAMMA) was applied to characterize aerosol particles collected and separated from 16m to 0.06m by a low pressure cascade impactor. Positive ion LAMMA spectra showed characteristic molecular peaks such as PbCl+, a series of Si2O+–Si2O4 + and NaAl2Si2O2 +–NaAl2Si2O5 +, and TiO+ in 0.06–0.12m, 0.5–1m and 4–8m fraction, respectively. In the negative ion LAMMA spectra, it was observed that the fragment peaks of sulfate ions were deficient above 2m and those of nitrate ions were deficient under 2m. LAMMA allows remarkable insights into the chemical nature of aerosol particles.
Charakterisierung luftgetragener Teilchen durch Laser-Microprobe-Massenspektrometrie
Zusammenfassung Laser-Microprobe-Spektrometrie (LAMMS) wurde zur Analyse atmosphärischen Aerosols herangezogen, welches im Korngrößenbereich zwischen 16m und 0.06m mit einem Niederdruckkaskadenimpaktor fraktioniert gesammelt wurde. Positive LAMMS-Spektren zeigten charakteristische molekulare Peaks, wie etwa PbCl+, eine Serie von Si2O+–Si2O4 + und NaAl2Si2O2 +–NaAl2Si2O5 +, sowie TiO+ in der 0,06–0,12-m,- 0,5–1–m- bzw. 4–8-m-Fraktion. In den negativen LAMMS-Spektren konnten über 2m keine Fragmentpeaks für Sulfationen, unter 2m. keine für Nitrationen beobachtet werden. LAMMS ermöglicht eine bemerkenswerte Einsicht in die chemische Natur von Aerosolteilchen.
  相似文献   

5.
Summary A rapid ion-exchange method for the determination of 144Ce, 137Cs, 89Sr, 90Sr and 140Ba in 2–30 liter samples of atmospheric water precipitations is described. The samples, containing up to 300 mg of calcium, are sorbed on a specially shaped column filled with Dowex 50, X-8 or Dowex 50W, X-8. Radio-cerium and radio-caesium are stripped from the column with 0.6 M ammonium glycolate/ 0.2 M NaCl, pH 5, radio-strontium and radio-barium with 0.15 M ammonium citrate, pH 7.5. The isolated radio-nuclides are counted on a low-background beta-counter: 144Ce as CeO2, 137Cs as Cs-dipicrylaminate, 89Sr/90Sr as SrCO3, 90Y as Y2O3, and 140Ba as BaCO3. The mean chemical yields amount to 95% for cerium, 85% for caesium, 95% for strontium, 95% for yttrium and 65% for barium. With parallel determinations at levels of a few picocuries, the deviations of the results from the respective mean values generally do not exceed ± 5%. With a 30 l sample the limit of detection amounts to 0.005 Ci/l for 144Ce, 0.006 Ci/l for 137Cs, 0.005 Ci/l for 90Sr, and 0.006 Ci/l for 140Ba.
Zusammenfassung Es wird eine schnelle Ionenaustauschmethode für die Bestimmung von 144Ce, 137Cs, 89Sr, 90Sr und 140Ba in 2–30 l Proben von atmosphärischen Wasser-Niederschlägen beschrieben. Die Proben, mit einem Calciumgehalt bis zu 300 mg, werden in eine besonders gestaltete, mit Dowex 50, X-8 oder Dowex 50 W, X-8 gefüllte Säule eingewaschen. Radio-Cer und Radio-Caesium werden mit 0,6 M Ammoniumglykolat/0,2 M NaCl, pH 5, Radio-Strontium und Radio-Barium mit 0,15 M Ammoniumcitrat pH 7,5 eluiert. Die isolierten Radio-Nuklide werden in einem Beta-Antikoinzidenzzähler gemessen: 144Ce als CeO2, 137Cs als Cs-dipikrylaminat, 89Sr/90Sr als SrCO3, 90Y als Y2O3 und 140Ba als BaCO3. Die mittlere Rückgewinnung der zugesetzten Träger beträgt für Cer 95%, 85% für Caesium, 95% für Strontium, 95% für Yttrium und 65% für Barium. In Parallelbestimmungen mit Gehalten von einigen Ci/l, überschreiten die Abweichungen der Ergebnisse von den entsprechenden Mittelwerten im allgemein nicht 5%. Bei einer 30 l-Probe beträgt die untere Nachweisgrenze 0,005 Ci/l für 144Ce, 0,006 Ci/l für 137Cs, 0,005 Ci/l für 90Sr und 0,006 Ci/l für 140Ba.
  相似文献   

6.
Xu  Feng  Chen  Yong-Mei  Yang  Shi-Yan  Sun  Wen-Hua  Yu  Kai-Bei 《Transition Metal Chemistry》2000,25(1):108-111
CpMoFeCo(CO)7(3-S) reacts with Cp*M(CO)3Cl or CpM(CO)3Cl (M=W, Mo) to gave the mixed-metal clusters Cp*WCpMoFe(CO)7(3-S) (1), Cp*MoCpMoFe(CO)7(3-S) (2), CpWCp*MoFe(CO)7(3-S) (3), CpMoCp*MoFe(CO)7(3-S) (4) and Cp*WCp*MoFe(CO)7(3-S) (5). The title clusters have been characterized by i.r., 1H/13C-n.m.r. spectroscopy and their compositions have been confirmed by elemental analyses. The X-ray crystal structure analysis shows the two independent enantiomeric molecules of clusters (1) in one crystal structure unit.  相似文献   

7.
Fluoride and sulphate complexing of Np(VI) has been studied by controlled-potential coulometry at a constant ionic strength. The values of 1 * and 2 * for fluoride complexes were found to be 9.4 and 8.9, respectively, at an ionic strength =0.5. At an ionic strength =1.0, 1 * and 2 * obtained were 6.6 and 10.5, respectively. Sulphate complexing of Np(VI) was studied only at an ionic strength =0.5. The value of 1 * obtained was 5.6.  相似文献   

8.
First- and second-derivative spectrophoto-metric methods for the simultaneous determination of aluminium and iron in their mixtures are described. The methods are based on the colored complexes formed by aluminium and iron with hematoxylin in the presence of cetyltrimethylammonium bromide as a surfactant. The zero-crossing method has been utilized to measure the first- and second-derivative value of the derivative spectrum. Aluminium (0.05–1 gml-1) could be determined in the presence of iron (0.09–1.6 gml-1) and vice versa. The detection limits of aluminium and iron are 0.01 and 0.09 gml-1, respectively in the first-derivative mode and 0.014 and 0.1 gml-1 in the second-derivative mode. The proposed method has been applied to the simultaneous determination of aluminium and iron in glasses, phosphate rocks, cement and magnesite alloy.  相似文献   

9.
The reaction between Ru3(3-2-PhC2C=CPh)(-dppm)(CO)8 and Co2(CO)8 afforded dark red Co2Ru3(4-C2Ph)(3-C2Ph)(-dppm)(-CO)2(CO)9, shown by an X-ray structure determination to contain a strongly twisted Co2Ru3 bow-tie cluster (central Co), to which two PhC2 units derived from cleavage of the original diyne are attached. One a these is strongly interacting with four metal atoms, the other being attached in the familiar 1,22-mode. The dppm ligand remains bridging two of the Ru atoms.  相似文献   

10.
Tri-2-disulfido-3-thiotris(diethyldithiocarbamato)-S,S'-triangle-trimolybdenum bromide [Mo3(3-S)(2-S2)3(Et2NCS2)3 +Br- was obtained and characterized.  相似文献   

11.
Summary A gas chromatograph/mass selective detector method is presented for the analysis of the major metabolic residues of metolachlor by acid hydrolysis of tomato fruit. The two major hydrolysis products, CGA-37913 (2-[2-ethyl-6-methylphenyl]amino-1-propanol) and derivatised CGA-49751 (4-[2-ethyl-6-methylphenyl]-2-hydroxy-5-methyl-3-morpholinone) were monitored in the selective ion mode atm/z 162 andm/z 160, respectively. Recoveries from 87 to 96% were obtained for tomato fortified at 50 to 200g kg–1. The proposed method of analysis will allow for a detection limit of 11 g kg–1 for CGA-37913 and 12 g kg–1 for the derivatised CGA-49751.  相似文献   

12.
Inductively coupled plasma-mass spectrometry (ICP-MS) was used to determine the concentration of platinum (Pt) in silicone breast implant gel (range, 0.26–48.90 g g–1 Pt; n=15), elastomer (range, 3.05–28.78 g g–1 Pt; n=7), double lumen (range, 5.79–125.27 g g–1 Pt; n=7), foam (range, 5.79–8.36 g g–1 Pt; n=2), and capsular tissue (range, 0.003–0.272 g g–1 Pt; n=15). The results show that very high levels of Pt are present in the encasing elastomer, double lumen, and foam envelope materials. Silicone breast implants can be a source of significant Pt exposure for individuals with these implants.  相似文献   

13.
The effect of cationic surfactants (cetyltrimethylammonium bromide, cetylpyridinium bromide, and tetrabutylammonium perchlorate) and a nonionic surfactant (OP-7) on the conditions of the immobilization of 4-(2-pyridylazo)resorcinol (PAR) on three types of silica gel (Silochrom S-120 (200–350 m), Silochrom S-120 (315–500 m), and Silochrom S-80 (200–350 m)) was studied. It was found that OP-7 does not affect the adsorption of surfactants. The effect of cationic surfactants increases in the order tetrabutylammonium perchlorate < cetyltrimethylammonium bromide < cetylpyridinium bromide. The adsorption activity of silica gels increases in the order Silochrom S-120 (315–500 m) < Silochrom S-80 (200–350 m) < Silochrom S-120 (200–350 m). Cetylpyridinium bromide provides full immobilization of PAR on silica gel Silochrom S-120 (200–350 m) in the pH range 2–9.  相似文献   

14.
A method for the fast routine analysis of the total content of volatile organic compounds in wallcoverings and paper products was developed, using headspace gas-chromatography for quantification. 57 wallcoverings of different types were investigated. Typical components were toluene, methyl-ethyl ketone, methyl-iso-butyl ketone, n-butyl acetate and iso-butyl acetate, all compounds being used as industrial solvents. The TVOC concentrations are calculated in toluene-carbon equivalents and ranged from 0.31 g/g to 1789 g/g with an average value of 123.22 g/g and a median of 20.37 g/g. To obtain an estimation of VOC-concentrations in indoor air, 10 selected wallcoverings were also analyzed in a 1 m3 climate test chamber. A correlation between headspace data and chamber concentrations could not be observed, which might be a result of increased analytical uncertainties at low emission rates under chamber conditions.  相似文献   

15.
The reactions of 8-amino-2,4-dimethylquinoline (L) (1) with polynuclear nickel(ii) and cobalt(ii) hydroxotrimethylacetato complexes under anaerobic conditions were studied. The nonanuclear cluster Ni9(4-OH)3(3-OH)3(n-OOCCMe3)12(HOOCCMe3)4 gave the mononuclear complex Ni(2-L)(2-OOCCMe3)2 (2). The tetranuclear complex Ni4(3-OH)2(-OOCCMe3)4(2-OOCCMe3)2(EtOH)6 produced the mononuclear complex Ni(2-L)(2-OOCCMe3)(OOCCMe3)L (3). At room temperature, the cobalt-containing polynuclear trimethylacetates, viz., the polymer [Co(OH) n (OOCCMe3)2–n ] x and the tetranuclear complex Co4(3-OH)2(-OOCCMe3)4(2-OOCCMe3)2(EtOH)6, were transformed into the trinuclear cobalt(ii) complex Co3(3-OH)(-OOCCMe3)4(2-L)2(OOCCMe3) (4). Meanwhile, at 80 °C these compounds generated the binuclear cobalt(iii) complex Co2(22-(HN)C9NMe2)2(-OOCCMe3)(L)(OOCCMe3)3 (5). The structures of the resulting compounds were established by X-ray diffraction analysis. Compounds 24 exhibit the antiferromagnetic spin-spin exchange coupling, whereas compound 5 is diamagnetic.  相似文献   

16.
    
Zusammenfassung 2-Thiobarbitursäure wird zum Nachweis und zur Bestimmung von Fe(III) verwendet. Im Reagensglas kann noch 1 g Fe(III)/ml nachgewiesen werden. Eine größere Empfindlichkeit (0,2 g/ml) wird bei Anwendung eines mit Thiobarbitursäurelösung getränkten Papiers erreicht. Die photometrische Bestimmung ist im Konzentrationsbereich 4–40 g/ml mit einem Fehler von höchstens ±0,5 g möglich.
Summary 2-Thiobarbituric acid is recommended for the detection and determination of trivalent iron. In the test tube 1 g of Fe(III)/ml can be detected, whereas this limit can be reduced to 0.2 g of Fe(III)/ml by use of paper impregnated with the reagent. The photometric determination is possible within the range of 4–40 g of Fe(III)/ml with an error of not more than ±0.5 g.
  相似文献   

17.
The absorption spectra of 4f electron transitions of the systems of neodymium and erbium with 2-isobutylformyl-1,3-dione-indane and TX-100 have been studied by normal and derivative spectrophotometry. Their molar absorptivities at the maximum absorption bands are about 7.2 (at 571 nm) times greater for neodymium and 13.1 (at 519 nm) times greater for erbium than those in the absence of the complexing agents. Use of second derivative spectra both eliminates the interference from other rare earths and increases the sensitivity from neodymium and erbium. Beers law is obeyed from 020 g/ml for neodymium and 025 g/ml for erbium. The relative standard deviations are 1.2% and 1.6% for 5.0 g/ml of neodymium and 8.0 g/ml of erbium, respectively. The detection limits (signal-to-noise ratio=2) are 0.14 g/ml and 0.20 g/ml. A method for the direct determination of neodymium and erbium in rare earth mixtures with good accuracy and selectivity is proposed.  相似文献   

18.
Zusammenfassung Systematische Bestimmungen des Fluoridgehaltes in verschiedenen Wasserproben aus Serbien und in Luftproben aus einigen In-dustriegebieten und aus der Stadt Belgrad wurden durchgeführt. Außerdem wurde der Fluoridgehalt in einigen meistkonsumierten Mineralwässern aus alien Territorien Jugoslawiens geprüft. Etwa 600 Proben wurden analysiert. Die Ergebnisse sollen für die kartographische Erfassung der Verteilung von Fluor im Trinkwasser dienen.
Determination of fluoride in Yugoslavian air and water with an ion-sensitive electrode
Summary Fluoride has been measured in over 600 samples of air and water with an ion-sensitive electrode. The concentrations found in the air samples were 1.6–l08g/m3 for industrial areas, 1.9–25.6g/m3 for urban areas and 1.1–18.4g/m3 for rural areas. Most of the samples had fluoride levels below 20g/m33. The concentrations found in water samples were 0.12–0.34g/litre for drinking water and 0.27–5.6g/litre, for mineral waters.
  相似文献   

19.
Zusammenfassung Ein schnelles und einfaches Mikroverfahren zum Nachweis einiger Heteroatome organischer Verbindungen wurde entwickelt. Nach Aufschluß mit metallischem Kalium werden die entstehenden Ionen mit der Ringofenmethode getrennt und mit empfindlichen Reaktionen nachgewiesen. Nachweisgrenze: 0,5 bis 1g Stickstoff, 1 bis 2g Schwefel, 2 bis 3g Jod, 4 bis 5g Brom, 5 bis 10g Chlor in 0,5 bis 1 mg Einwaage.
Summary A rapid and simple micromethod was developed for the detection of several hetero-elements in organic compounds. After breaking down the sample with metallic potassium, the resulting ions are separated by the ring oven method and detected by means of sensitive reagents. Detection limits: 0.5 to 1g nitrogen, 1 to 2g sulfur, 2 to 3g iodine, 4 to 5g bromine, 5 to 10g chlorine in samples weighing 0.5 to 1 mg.

Résumé On a découvert un procédé à l'échelle micro, simple et rapide, pour rechercher certains hétéroéléments dans les composés organiques. Après mise en solution par le potassium métallique, on sépare les ions formés suivant la méthode du four annulaire et l'on effectue la recherche au moyen de réactions sensibles. Limite de dilution: 0,5 à 1g d'azote, 1 àg de soufre, 2 àg d'iode, 5 à 10g de chlore sur 0,5 à 1 mg de prise d'essai.
  相似文献   

20.
In a long-term field study at two locations with different air pollution levels several soot-selective measurement techniques were compared with a thermochemical method which measures non-extractable carbon (NEC) detecting the evolved CO2 by means of coulometric titration. The attenuation measurement technique (aethalometer) and the aerosol photoemission method showed good correlations to NEC for concentrations ranging from 1.6g/m3 to 40.8g/m3. The specific mass absorption coefficient of black carbon with respect to NEC varied between 8.4m2/g and 13.7m2/g with respect to the measurement sites, but the value was found to remain constant at each site independent of seasonal or meteorological variations. The ratio of photoelectric signal to NEC varied between 16 fA·(g/m3)–1 and 33 fA·(g/m3)–1 depending on the age of the aerosol. The diurnal variations of that ratio showed strong similarities to the traffic patterns. Additionally a slight temperature dependence of this ratio was found for the aged aerosol with a proportionality factor of – 0.35 fA·(K·g/m3)–1. With the reflectance measurement technique (smoke shade method) reliable NEC determination was not possible for NEC concentrations 5 g/m3.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏