1.
A PVC membrane electrode for copper ion based on 1,3-dithiane,2-(4-methoxy phenyl) as ionophore and o-nitrophenyl octyl ether as a plasticizer is demonstrated. The electrode exhibits a Nernstian slope of 29.5±1 mV per decade in a linear range of 3.0×10−6 to 5.0×10−2 M for Cu2+ ion. The detection limit of this electrode is 1.0×10−6 mol/l. This sensor has a very short response time of about 5 s and could be used in a pH range of 4.0-7.0. High selectivity was obtained over a wide variety of metal ions. The proposed electrode was successfully applied as an indicator electrode for the potentiometric titration of copper ion with EDTA and for the direct determination of copper in river water.  相似文献   

2.
Singh AK  Saxena P  Mehtab S  Gupta B 《Talanta》2006,69(2):521-526
A new PVC membrane electrode based on 5,7,12,14-dibenzo-2,3,9,10-tetraoxa-1,4,8,11-tetraazacyclotetradecane (I) as an ion carrier, o-nitrophenyloctyl ether (o-NPOE) as solvent mediator and sodium tetraphenylborate (NaTPB) as lipophilic additive was fabricated and investigated as Sr2+-selective electrode. The best performance was exhibited by the membrane having composition 8:200:4:120 (I:o-NPOE:NaTPB:PVC). The electrode exhibited a Nernstian response for strontium ion over a wide concentration range 3.98 × 10−6 to 1.0 × 10−1 M with a slope of 29.0 ± 0.1 mV/decade of concentration and a detection limit of 2.82 × 10−6 M. It showed a response time of less than 10 s and could be used for at least 3 months without any divergence in potential. The proposed electrode showed a good discriminating ability towards strontium(II) ion over a wide variety of other metal ions including alkali, alkaline earth, transition, and heavy metal ions. The electrode can be used in the pH range of 2.5-10.5 and in mixtures containing up to 35% (v/v) non-aqueous content. It was used as an indicator electrode in potentiometric titration of strontium ion against EDTA.  相似文献   

3.
A poly(vinyl chloride)-based membrane of 3,4:11,12-dibenzo-1,6,9,14-tetraazacyclohexadecane with sodium tetraphenyl borate (NaTPB) as an anion excluder and dibutylphthalate (DBP), dibutyl(butyl)phosphonate (DBBP), tris(2-ethylhexyl)phosphate (TEHP) and tributyl phosphate (TBP) as a plasticizing solvent mediator was prepared and investigated as a Cd2+-selective electrode. The best performance was observed with the membrane having a ligand-PVC-DBP-NaTPB composition of 2:25:60:1, which worked well over a wide concentration range (1.6 x 10(-6) - 1.0 x 10(-1) M) with a Nernstian slope of 29.5 mV per decade of activity between pH 2.0 - 6.0. This electrode showed a fast response time of 13 s and was used over a period of 4 months with good reproducibility (S = 0.4 mV). The selectivity coefficient for mono-, di- and trivalent cations indicated excellent selectivity for Cd2+ ions over a large number of cations. Anions such as NO3- and SO4(2-) , did not interfere. The membrane sensor has been successfully used to determine Cd2+ in real samples.  相似文献   

4.
A new PVC membrane electrode for Zn2+ ions based on tetra(2-aminophenyl) porphyrin (TAPP) as membrane carrier is prepared. The sensor exhibits a linear stable response over a wide concentration range (5.0×10−5 to 1.0×10−1 M) with a slope of 26.5 mV/decade and a limit of detection 3.0×10−5 M (1.96 ppm). It has a response time of about l0 s and can be used for at least 8 months without any divergence in potential. The propose membrane sensor revealed good selectivities for Zn2+ over a wide variety of other metal ions and can be used in pH range of 3.0–6.0. It was successfully applied to the direct determination of zinc in a pharmaceutical sample and also as an indicator electrode in potentiometric titration of Zn2+ ions.  相似文献   

5.
A PVC-membrane electrode based on a recently synthesized 18-membered macrocyclic diamide is presented. The electrode reveals a Nernstian potentiometric response for Co2+ over a wide concentration range (2.0 x 10(-6)-1.0 x 10(-2) M). The electrode has a response time of about 10 s and can be used for at least 2 months without any divergence. The proposed sensor revealed very good selectivities for Co2+ over a wide variety of other metal ions, and could be used over a wide pH range (3.0-8.0). The detection limit of the sensor is 6.0 x 10(-7) M. It was successfully applied to the direct determination and potentiometric titration of cobalt ion.  相似文献   

6.
A cobalt-selective electrode based on the benzalkonium tetrathiocyanatocobaltate(II) ion pair is described. The response is Nemstian (slope 29.3 mVpCo) in the cobalt concentration range 10-1–10-4 M in solutions with a constant ionic strength of 3.0 M made up with KSCN at 25°C. The electrode is suitable for end-point detection in titrations of cobalt(II) with EDTA as well as for direct potentiometric determinations of cobalt(II), even in the presence of large amounts of several metal ions (Ni2+, Fe2+, Mn2+, Mg2+, Ca2+, Ba2+) and anions (HCO3-, Br-, I-, NO3-, SO42-).  相似文献   

7.
A new lead(II)-selective electrode has been developed based on bis(acetylacetone)-p-phenylenediamine-lead(II) [LPb(NO3)2]H2O complex ionophore as a sensing material, dioctylphthalate (DOP) as a solvent mediator and PVC as a matrix. This electrode exhibits a linear Nernstian response over the concentration range of 1 x 10(-5)-1 x 10(-1) mol l(-1) of Pb(II) cation, with a cationic calibration slope of 30.0 +/- 0.2 mV/concentration decade and a detection limit of 2 x 10(-6) mol l(-1) (0.40 ppm). It has a fast response time and can be used for a period of 2 months without any divergence in potentials. The proposed electrode reveals a good selectivity for Pb(II) over a wide variety of other tested cations and could be used in the pH range of 4-8. It was successfully used for direct determination of Pb(II) concentration in some samples. The obtained results show a good agreement with those obtained by an atomic absorption spectrometric method. The average recovery obtained is 96.5 +/- 0.5% with standard deviation of 1.2% (n = 8).  相似文献   

8.
Xin-Gui Li  Xiao-Li Ma 《Talanta》2009,78(2):498-140
A new polyvinylchloride membrane electrode was facilely prepared by using polyaminoanthraquinone (PAAQ) microparticles with an intrinsically electrical conductivity as a lead(II) ionophore. It is found that the electrode performance will significantly be improved with adding 1 wt% PAAQ microparticles and decreasing the membrane thickness. A 90 μm-thick membrane electrode consisting of PAAQ(salt):polyvinyl chloride:dioctylphthalate:sodium tetraphenylborate of 1:33:66:1 (wt) but without any traditional lead(II) ionophore achieved the optimal performance and exhibited a good Nernstian response for Pb(II) ions over a wide concentration range from 2.5 × 10−6 to 0.1 M with a slope of 28.9 mV/decade and a detection limit down to 776 nM. A reasonably short response time of 12 s was revealed together with a long lifetime over a period of around 4 months in a wide pH range between 2.8 and 5.2. A fixed interference method indicated that the electrode has an excellent selectivity for lead(II) ion over alkali, alkaline earth and other heavy metal ions. The proposed electrode has been also found to be a powerful indicator electrode for potentiometric titration of Pb(II) ions with EDTA. The electrode can be used to accurately monitor the Pb(II) pollution in environmental waters.  相似文献   

9.
An extract of crystal violet-tetrachloroferrate(III) in nitrobenzene was used to prepare a tetrachloroferrate(III)-selective liquid membrane electrode with a poly(vinyl chloride) support. The optimal conditions to determine 2.5 × 10–5 – 5.0 × 10–2 M iron(III) as tetrachloroferrate(III) (anionic slope 56 mV/decade, detection limit 7.9 × 10–6 M) were found to be 4.0–5.5.M total chloride in 0.75–1.5M hydrochloric acid. The electrode was reliably applied to determine iron in human blood, haematite and mineralized vitamin syrup by direct potentiometry, standard and sample additions as well as standard subtraction techniques.  相似文献   

10.
A new PVC-membrane electrode for Co2+ ions based on N,N′-di(thiazol-2-yl)formimidamide (TF) as membrane carrier has been developed. The electrode resulted in Nernstian response (29.5?±?0.4?mV decade?1) for Co2+ ion over a wide concentration range (2.5?×?10?7 ?1.0?×?10?1?M) with a detection limit of 6.1?×?10?8?M. The sensor has a response time of about 10?s, and can be used for at least 2 months without observing any deviation from the Nernstain response. The electrode revealed good selectivity towards cobalt(II) ion over a wide variety of alkali, alkaline earth, transition, and heavy metal ions and could be used in the pH range 2.0–7.0. The electrode was used for determination of Co2+ in real samples.  相似文献   

11.
12.
13.
Gholivand MB  Nozari N 《Talanta》2001,54(4):597-602
Poly(vinyl chloride) membrane electrode, that is highly selective and sensitive to Cu(II) ions, was developed by using 2,2'-dithiodianiline and dibutyl phthalate as carrier and plasticizer, respectively. The electrode exhibits good potentiometric response for Cu(II) over a wide concentration range (5.0x10(-2)-7.0x10(-7) mol l(-1)) with Nernstian slope of 30+/-1 mV per decade. The response time of the electrode is 10 s and it has been used for a period of one month and exhibits good selectivity towards Cu(2+) in comparison to alkali, alkaline earth, transition and heavy metal ions, with no interference caused by Pb(2+), Cd(2+) and Fe(+2) which are known to interfere with many other copper electrodes.  相似文献   

14.
15.
ABSTRACT

A novel ion-selective electrochemical sensor based on kryptofix-22DD (1,10-didecyl-1,10-diaza-18-crown-6) as an ionophore was constructed for determination of lanthanum(III) cation in solutions. The D-Optimal Mixture Design(D-OMD) was used as an experimental design strategy for optimal formulation of the membrane ingredients, and the actual values of the ingredients were compared with their predicted values. The amounts of the ionophore, plasticizer, PVC, and also the graphite powder which influence the performance of the fabricated electrode were analyzed using D-OMD. A non-linear relationship was observed between the slope of the electrochemical response of the electrode and these variables and the interaction between the variables as well. The experimental results showed that the amount of the ionophore has the most positive effect on the electrochemical response of the electrode. The constructed electrode exhibits a Nernstian slope (20.60 ± 0.21 mv.decade?1) in a wide linear concentration range from 1.0 × 10?7 to 1.0 × 10?1 M with respect to La3+ cation at pH range of 4.0 to 6.0, and its detection limit was found to be:0.8 × 10?7M. The selectivity of the proposed electrode towards some of the metal cations present in lanthanum(III) cation solutions was tested, and the experimental results showed a good selectivity towards this metal cation.  相似文献   

16.
The incorporation, behaviour and suitability of a home-made coated tubular solid-state copper(II)-selective electrode into the conduits of a flow-injection system is described. The compact tubular sensor (volume 7.8 μl) is constructed from a copper tube and Tygon tubing, treated with ammonium sulphide to give the copper/copper sulphide electrode and conditioned in an ascorbic acid medium. Interferences of foreign ions are similar to those found in batch analysis, but are less severe in the flow-injection system. Changes in carrier stream pH between 1 and 3 affected the electrode response, but sample pH has no or little influence in the range 1–7 depending on the copper(II) ion concentration in the samples. With 30-μl samples the flow-through electrode system covers a working range up to 5000 mg dm?3 with a detection limit of 0.5 mg dm?3. The system is suitable for the determination of copper(II) in effluent and tap water (relative standard deviation < 1.75% for 0.5–912 mg dm?3 copper) and acidic copper sulphate plating solutions (relative standard deviation < 1.21% for 87–4135 mg dm?3 copper) at a sample frequency of about 80 h?1. The results obtained agree well with results by a standard atomic absorption spectrometric method.  相似文献   

17.
An attempt has been made to develop a highly selective Cu2+-ion selective electrode based on a poly(vinyl chloride) based sensor using 1,2,5,6,8,11-hexaazacyclododeca-7,12-dione-2,4,8,10-tetraene as ionophore with 61.5% DBP in the presence of 29% PVC, 4.5% ionophore and 5% NaTBP as an anion excluder. The sensor exhibits a near Nernstian potential response of 29.5 +/- 0.3 mV per decade over a wide concentration range (2.0 x 10(-7) - 1 x 10(-1) M) with a detection limit of 8.1 x 10(-8) M between pH 3 - 11 with a fast response time of < 5 s. The selectivity coefficient values, as determined by the matched potential method (MPM), indicate excellent selectivity for Cu(II) ions over a large number of ions. The proposed sensor exhibits an adequate shelf life (4 - 5 months) with good reproducibility. The quantification of Cu(II) in electroplating wastewater and various brands of Indian tea was successfully achieved using the proposed sensor.  相似文献   

18.
A PVC membrane electrode for aluminium ion based on bis(5-phenyl azo salicylaldehyde) 2,3-naphthalene diimine (5PHAZOSALNPHN) as an ion carrier was developed. The electrode exhibits a Nernstian slope of 19.3+/-0.8 mV per decade and a linear range of 5.0x10(-6)-1.0x10(-2) M for Al(NO(3))(3). The limit of detection is 2.5x10(-6) M. It has a fast response time of about 10 s and can be used for at least 10 weeks without observing any deviation. The proposed membrane sensor revealed good selectivity for Al(3+) over a wide variety of other metal ions and could be used in pH range of 2.9-5.0. It was used as an indicator electrode in potentiometric titration of aluminium ion.  相似文献   

19.
The performance of octahydroxycalix[4]arene derivative used as a neutral carrier for silver polymeric membrane electrode was studied. The sensor gave a good Nernstian response of 58 +/- 1 mV per decade for silver ion in the activity range 3.3 x 10(-6) to 3.3 x 10(-2) M Ag+. The limit of detection reached 2.1 x 10(-6) M Ag+ and exhibited high selectivity for silver ion against the alkali, alkaline earth and transition metal ions. The sensor can be used in wide pH range from 1.5 to 6.5. The response time of the sensor is less than 20 s. The potentiometric sensor was used as the indicator electrode in the titration of Ag+ ions by sodium chloride solution.  相似文献   

20.
An optical single shot test for copper(II) ion is presented. The membrane consists of a polyester support and an active layer composed of hydrogel, a hydroxylic plasticizer, and Zincon. The latter has been made lipophilic by ion-pairing with tetraoctyl-ammonium bromide. The membrane responds to copper ions in giving a color change from pink to blue. Because the layer irreversibly extracts copper from the solution, a kinetic approach has been used for quantitation, in that the membrane has been exposed to the sample for 2 min and the initial slope of the response curve has been determined. A linear calibration graph has been obtained for the 1 to 100 mol/l (63.5 g/kg to 6.35 mg/kg) copper concentration range. The complexed form of the dye exhibits an absorption maximum of 620 nm which matches the emission band of the orange light-emitting diode (LED). Measurements have been performed at pH 6, because no complexation of zinc occurs in this range. The long term stability of the membrane exceeds 6 months when stored dry and in the dark. The strong binding of copper ions along with the fairly high selectivity of the membrane also suggests its use as a preconcentration phase.Dedicated to Professor Dr. Dieter Klockow on the occasion of his 60th birthday  相似文献   