首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A simple method for the simultaneous determination of morphine and its pharmacologically active metabolite morphine-6-glucuronide in 0.5 ml human plasma is described. It is based on the method of Svensson [J. Chromatogr., 230 (1982) 427 and 375 (1986) 174], but uses only one solid-phase extraction cartridge prior to chromatography and only a 20-microliter injection volume. Mean recoveries of 90 and 85% for morphine and morphine-6-glucuronide, respectively, were obtained, the limit of detection being 2 nmol/l (at a signal-to-noise ratio of 3.0).  相似文献   

2.
A sensitive and specific method for the determination of morphine glucuronides in human plasma is presented. Morphine glucuronides, namely morphine-6-glucuronide (M6G) and morphine-3-glucuronide (M3G), were extracted from plasma by solid-phase extraction on C(18) cartridges at pH 9.3 and derivatized to their pentafluorobenzyl ester trimethylsilyl ether derivatives. The compounds were measured by gas chromatography/negative ion chemical ionization mass spectrometry without any further purification. Using this detection mode, a diagnostic useful fragment ion at m/z 748 was obtained at high relative abundance for both target compounds. [(2)H(3)]-labeled morphine glucuronides were used as internal standards. Calibration graphs were calculated by polynomial fit within a range of 10-1280 and 15-1920 nmol l(-1) for the 6- and 3-glucuronide, respectively. At the limit of quantitation (LOQ), the inter-assay precision was 2.21% (M3G) and 2.23% (M6G) and the GC/MS assay variability was 1.8% (M3G) and 0.9% (M6G). The accuracy at the LOQ showed deviations of +4.92% (M3G) and +1.5% (M6G). The sample recovery after solid-phase extraction was 84.7% for both M3G and M6G. The method is rugged, rapid and robust and has been applied to the batch analysis of morphine glucuronides during pharmacokinetic profiling of the drugs.  相似文献   

3.
A sensitive and reproducible method for the determination of morphine and the metabolites morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G) was developed. The method was validated for perfusion fluid used in microdialysis as well as for sheep and human plasma. A C18 guard column was used to desalt the samples before analytical separation on a ZIC HILIC (hydrophilic interaction chromatography) column and detection with tandem mass spectrometry (MS/MS). The mobile phases were 0.05% trifluoroacetic acid (TFA) for desalting and acetonitrile/5 mM ammonium acetate (70:30) for separation. Microdialysis samples (5 microL) were directly injected onto the system. The lower limits of quantification (LLOQ) for morphine, M3G and M6G were 0.50, 0.22 and 0.55 ng/mL, respectively, and the method was linear from LLOQ to 200 ng/mL. For plasma, a volume of 100 microL was precipitated with acetonitrile containing internal standards (deuterated morphine and metabolites). The supernatant was evaporated and reconstituted in 0.05% TFA before the desalting process. The LLOQs for sheep plasma were 2.0 and 3.1 ng/mL and the ranges were 2.0-2000 and 3.1-3100 ng/mL for morphine and M3G, respectively. For human plasma, the LLOQs were 0.78, 1.49 and 0.53 ng/mL and the ranges were 0.78-500, 1.49-1000 and 0.53-500 ng/mL for morphine, M3G and M6G, respectively.  相似文献   

4.
Ultrafast liquid chromatography/tandem mass spectrometry (LC/MS/MS) bioanalysis was demonstrated with the use of packed silica columns operated under elevated flow rates. A special effort has been made to achieve ultrafast analysis without sacrificing chromatographic resolution. Two multiple analyte/metabolites assays, (1) morphine/morphine-6-glucuronide(M6G)/morphine-3-glucuronide(M3G) and (2) midazolam/1'-hydroxymidazolam/4-hydroxymidazolam, were used to demonstrate the speed, sensitivity, peak shape and separation of the ultrafast methods utilizing silica columns. In both methods adequate chromatographic separation was a necessity because quantitation results would be otherwise compromised due to cross interference between different selected reaction monitoring (SRM) transitions. Baseline resolutions between morphine, M6G and M3G in human plasma extracts were achieved within 30 s on a 50 x 3 mm Betasil silica column operated at 4 mL/min of isocratic acetonitrile/water mobile phase. The total injection-to-injection cycle time was 48 s with a simple, single-autosampler/single-column setup, when a Shimadzu SIL-HT autosampler was used. Baseline resolution between 1'-hydroxymidazolam and 4-hydroxymidalolam in monkey plasma extracts was achieved within 33 s using similar conditions. Due to the absence of carry-over in this case, no rinsing of the injection needle was necessary, resulting in a cycle time of only 39 s/sample. These ultrafast methods were successfully used to analyze extracted biological samples and proved to be reproducible, reliable and generated equivalent pharmaco-kinetic (PK) results to those obtained by regular flow LC/MS/MS analysis to support discovery PK studies.  相似文献   

5.
An isocratic high-performance liquid chromatographic method has been developed for the determination of morphine, morphine-3-glucuronide, morphine-6-glucuronide and codeine in plasma, urine and cerebrospinal fluid. The use of an efficient solid-phase extraction procedure together with a forward optical scanning detector allows a detection limit of 500 pg/ml. The method was evaluated by examination of biological samples taken from newborn infants following the intravenous administration of morphine sulfate.  相似文献   

6.
A method based on the direct injection of diluted urine for the identification and quantification of morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine, codeine-6-glucuronide, ethylmorphine, ethylmorphine-6-glucuronide and 6-acetylmorphine (6AM) in human urine by electrospray ionisation liquid chromatography-tandem mass spectrometry was validated for use as a confirmation procedure in urine drug testing. Four deuterium labelled analogues were used as internal standards: morphine-3-glucuronide-D3, morphine-D3, codeine-D3 and 6AM-D3. Twenty microlitre aliquots of urine were mixed with 80 mul of the internal standard solution in autosampler vials and 10 mul was injected. The chromatographic system consisted of a 2.0 x 100 mm C18 column and the gradient elution buffers used acetonitrile and 25 mmol/l formic acid. Two product ions produced from the protonated molecular ions were monitored in the selected reaction monitoring mode. The intra- and inter-assay variability (coefficient of variation) was below 10% at higher levels for all analytes, but at the reporting limits the variation was above 20% for 6AM, morphine-3-glucuronide and codeine-6-glucuronide. Ion suppression occurred early after injection but did not affect the identification and quantification of the analytes in authentic samples. The method was further validated by comparison with a reference gas chromatographic-mass spectrometric method using authentic urine samples. The two methods agreed almost completely (99%) regarding the identified analytes, but for the quantitative results there were slightly lower levels when measuring glucuronides directly as compared to total determination after hydrolysis by gas chromatography-mass spectrometry.We conclude that the presented liquid chromatographic-tandem mass spectrometric method is robust and reliable, and suitable for use as a confirmation method in urine drug testing for opiates  相似文献   

7.
Toyo'oka T  Yano M  Kato M  Nakahara Y 《The Analyst》2001,126(8):1339-1345
The simultaneous determination of morphine and the glucuronide metabolites [morphine-3-beta-D-glucuronide (M3G) and morphine-6-beta-D-glucuronide (M6G)] in rat hair and rat plasma was carried out using reversed-phase high-performance liquid chromatography (HPLC) coupled with electrospray ionization mass spectrometry (ESI-MS). The chromatographic separation of the analytes was achieved using a semi-micro-HPLC column (3 microm particle size; 100 x 2.0 mm id) by gradient elution with 50 mM ammonium acetate and acetonitrile as eluents. After separation, morphine and the glucuronides were determined by selected ion monitoring (SIM) of ESI-MS using the quasi-molecular ions [M + H]+ at m/z = 286 and 462, respectively. The calibration curves were linear between the concentration of the analytes and the deuterium-labelled morphine (M-d3) selected as internal standard. The method was applied for the determination of the incorporation of morphine and the glucuronides into the hair shafts and hair roots of Dark Agouti rats after single intraperitoneal administration of morphine hydrochloride. Plasma concentrations of morphine and glucuronides were simultaneously determined after administration. Morphine and M3G were detected in the hair shafts and the hair roots. The concentrations of M3G in the hair root were lower than those of morphine in all sampling periods. In contrast, M3G concentrations in plasma were relatively higher at each sampling time. Small quantities of M6G were also identified in the plasma up to 4 h after administration. The concentration difference between the hair root and plasma seems to be due to the incorporation ratio of morphine and glucuronide into hair. As M3G was also identified in the hair shaft 1 week after administration, the incorporation of glucuronide metabolites into hair is obvious. This is the first report of the identification of morphine glucuronide in hair samples without the use of acid hydrolysis or enzyme digestion.  相似文献   

8.
Lin YH  Chiang JF  Lee MR  Lee RJ  Ko WK  Wu SM 《Electrophoresis》2008,29(11):2340-2347
A cation-selective exhaustive injection and sweeping micellar EKC (CSEI-Sweep-MEKC) was established to analyze morphine and its four metabolites, including codeine, normorphine (NM), morphine-3-glucuronide (M3G), and morphine-6-glucuronide (M6G). After SPE, the urine samples were analyzed by this CE method. The phosphate buffer (75 mM, pH 2.5) containing 30% methanol was first filled into an uncoated fused-silica capillary (40 cm, 50 microm id), then a high-conductivity buffer (120 mM phosphate, 10.3 kPa for 99.9 s) followed. The pretreated urine sample was loaded by electrokinetic injection (10 kV, 600 s). The stacking and separation were performed by using phosphate buffer (25 mM, pH 2.5) containing 22% methanol and 100 mM SDS at -20 kV, and detected at 200 nm. During method validation, calibration plots were linear (r > or = 0.998) over a range of 30-3000 ng/mL for morphine, NM, and codeine, 100-2000 ng/mL for M6G, and 80-3200 ng/mL for M3G. The LODs (S/N = 5, sampling 600 s at 10 kV) were 10 ng/mL for morphine, NM, and codeine, 35 ng/mL for M6G, and 25 ng/mL for M3G. This stacking CE method could increase 2500-fold sensitivity of codeine, when comparing with CZE. Five addicts' urine specimens were analyzed. Their results were compared with those of LC-MS-MS, and showed good coincidence. This method could be feasible for monitoring morphine and its metabolites in forensic interest and pharmacokinetic investigations.  相似文献   

9.
For the first time chemical derivatization of isomeric drug glucuronides with 1,2-dimethylimidazole-4-sulfonyl chloride (DMISC) has been successfully applied as a tool for determining the site of conjugation. This provides a way to differentiate between glucuronide isomers containing aliphatic and phenolic hydroxyl groups. The analyses were performed with liquid chromatography/electrospray ion trap mass spectrometry (LC/ESI-MSn). DMISC has previously been shown to react selectively with phenols in estrogens, thus improving sensitivity in ESI-MS. The model compounds selected for this study were commercially available standards of formoterol, morphine, morphine-3-glucuronide (M3G), and morphine-6-glucuronide (M6G). Formoterol glucuronides were produced with an enzymatic method in house. Both formoterol and morphine possess one phenolic and one aliphatic hydroxyl group where glucuronidation could take place. The product ion mass spectra of the native morphine glucuronides were indistinguishable due to the initial neutral loss of monodehydrated glucuronic acid (176 u). However, a significant difference between the isomers was observed with DMISC derivatization, as only the form with a free phenol, M6G, gave a detectable reaction product. Formoterol formed two detectable glucuronide isomers in the enzymatic reaction. Their respective sites of conjugation could not be directly determined from the product ion spectra. Reaction with DMISC, however, gave a detectable product with only one of the isomers. Based on previous experience of the preferred DMISC reactions with phenols, and interpretation of the fragmentation pattern of the derivative, it was concluded that the reactive isomer had a free phenol, and was thus conjugated on the aliphatic chain.  相似文献   

10.
A method for the fast analysis of morphine (M), normorphine (NM), morphine-3- and -6-glucuronides (M3G and M6G) and codeine (C) is described which has the advantages of sensitivity, speed and specificity. Dihydrocodeine and heroin can also be assayed. The method is based on extraction of the opiates from serum, plasma and cerebrospinal fluid using reversed-phase solid-phase extraction columns, followed by reversed-phase high-performance liquid chromatography with native fluorescence detection. The extraction step provides greater than 95% recovery, and the response of the detection system is linear from 0.5 to beyond 750 ng. The method allows analysis of M, NM, M3G, M6G and C. No other drugs have been found to interfere with the assay. The assay offers a quick, cheap and reliable method of specifically determining morphine and its metabolites, including the potent M6G, from a small sample volume; this will be of advantage to both clinician and basic scientist.  相似文献   

11.
A robust ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method for the determination of morphine‐6‐d ‐glucuronide (M6G), morphine‐3‐d ‐glucuronide (M3G) and morphine (MOR) in human plasma and urine has been developed and validated. The analytes of interest were extracted from plasma by protein precipitation. The urine sample was prepared by dilution. Both plasma and urine samples were chromatographed on an Acquity UPLC HSS T3 column using gradient elution. Detection was performed on a Xevo TQ‐S tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. Matrix interferences were not observed at the retention time of the analytes and internal standard, naloxone‐D5. The lower limits of quantitation of plasma and urine were 2/0.5/0.5 and 20/4/2 ng/mL for M6G/M3G/MOR, respectively. Calibration curves were linear over the concentration ranges of 2–2000/0.5–500/0.5–500 and 20–20,000/4–4000/2–2000 ng/mL for M6G/M3G/MOR in plasma and urine samples, respectively. The precision was <7.14% and the accuracy was within 85–115%. Furthermore, stability of the analytes at various conditions, dilution integrity, extraction recovery and matrix effect were assessed. Finally, this quantitative method was successfully applied to the pharmacokinetic study of M6G injection in Chinese noncancer pain patients.  相似文献   

12.
An automated flow fluorometer designed for kinetic binding analysis was adapted to develop a solid-phase competitive fluoroimmunoassay for urinalysis of opiates. The solid phase consisted of polymer beads coated with commercial monoclonal antibodies (MAbs) raised against morphine. Fluorescein-conjugated morphine (FL-MOR) was used as the fluorescein-labeled hapten. The dissociation equilibrium constant (K D ) for the binding of FL-MOR to the anti-MOR MAb was 0.23 nM. The binding of FL-MOR to the anti-MOR MAb reached steady state within minutes and was displaced effectively by morphine and other opiates. Morphine-3-glucuronide (M3G), the major urinary metabolite of heroin and morphine, competed effectively with FL-MOR in a concentration-dependent manner for binding to the antimorphine MAb and was therefore used to construct the calibration curve. The sensitivity of the assay was 0.2 ng/mL for M3G. The assay was effective at concentrations of M3G from 0.2 to 50 ng/mL, with an IC50 of 2 ng/mL. Other opiates and heroin metabolites that showed >50% crossreactivity when present at 1 μg/mL included codeine, morphine-6-glucuronide, and oxycodone. Methadone showed very low crossreactivity (<5%), which is a benefit for testing in patients being treated for opiate addictions. The high sensitivity of the assay and the relatively high cutoff value for positive opiate tests allows very small sample volumes (e.g., in saliva or sweat) to be analyzed. A double-blind comparison using 205 clinical urine samples showed good agreement between this single-step competitive assay and a commercially performed enzyme multiplied immunoassay technique for the detection of opiates and benzoylecgonine (a metabolite of cocaine).  相似文献   

13.
Simultaneous determination of opiates and their glucuronides in body fluids has a great practical interest in the forensic assessment of heroin intoxication. A selective and sensitive method for quantification of morphine and its 3- and 6-glucuronides, codeine, codeine glucuronide and 6-monoacetylmorphine (6-MAM) based on liquid chromatography-electrospray ionisation mass spectrometry is described. The drugs were analysed in human autopsy whole blood after solid-phase extraction on a C8 cartridge. The separation was performed on an ODS column in acetonitrile (analysis time 15 min). For the quantitative analysis, deuterated analogues of each compound were used as internal standards. Selected-ion monitoring was applied where the molecular ion was chosen for quantification. The limits of quantification were 0.5 ng/ml for morphine and 6-MAM and 1 ng/ml for the 6-glucuronide of morphine, codeine-6-glucuronide and codeine and 5 ng/ml for the 3-glucuronide of morphine.  相似文献   

14.
This review focuses on recent developments in the physicochemical profiling of morphine and other opioids. The acid-base properties and lipophilicity of these compounds is discussed at the microscopic, species-specific level. Examples are provided where this type of information can reveal the mechanism of pharmacokinetic processes at the submolecular level. The role of lipophilicity in quantitative structure–activity relationship (QSAR) studies of opioids is reviewed. The physicochemical properties and pharmacology of the main metabolites of morphine are also discussed. Recent studies indicate that the active metabolite morphine-6-glucuronide (M6G) can contribute to the analgesic activity of systemically administered morphine. The unexpectedly high lipophilicity of M6G partly accounts for its analgesic activity. When administered parenterally, another suspected minor metabolite, morphine-6-sulfate (M6S) has superior antinociceptive effects to those of morphine. However, because sulfate esters of morphine derivatives cannot cross the blood-brain barrier these esters may be good candidates to develop peripheral analgesic drugs.  相似文献   

15.
Opioids such as morphine are the cornerstone of pain treatment. The challenge of measuring the concentrations of morphine and its active metabolites in order to assess human pharmacokinetics and monitor therapeutic drugs in children requires assays with high sensitivity in small blood volumes. We developed and validated a semi-automated LC-MS/MS assay for the simultaneous quantification of morphine and its active metabolites morphine 3β-glucuronide (M3G) and morphine 6β-glucuronide (M6G) in human plasma and in dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the internal standards were the only manual steps. Morphine and its metabolites were separated on a Kinetex 2.6-μm PFP analytical column using an acetonitrile/0.1% formic acid gradient. The analytes were detected in the positive multiple reaction mode. In plasma, the assay had the following performance characteristics: range of reliable response of 0.25–1000 ng/mL (r 2 > 0.99) for morphine, 1–1,000 ng/mL (r 2 > 0.99) for M3G, and 2.5–1,000 ng/mL for M6G. In DBS, the assay had a range of reliable response of 1–1,000 ng/mL (r 2 > 0.99) for morphine and M3G, and of 2.5–1,000 ng/mL for M6G. For inter-day accuracy and precision for morphine, M3G and M6G were within 15% of the nominal values in both plasma and DBS. There was no carryover, ion suppression, or matrix interferences. The assay fulfilled all predefined acceptance criteria, and its sensitivity using DBS samples was adequate for the measurement of pediatric pharmacokinetic samples using a small blood of only 20–50 μL.  相似文献   

16.
A method for the simultaneous measurement of floxuridine (5-fluorodeoxyuridine) and fluorouracil in human plasma and peritoneal fluid has been developed. This method utilizes high-performance liquid chromatographic analysis with a Zorbax RX column (25 cm x 4.6 mm I.D.) plus a guard cartridge of the same material. The sensitivity limits for this assay are 0.25 mumol/l in a 20-microliters sample. The detection limit at a signal-to-noise ratio of 3 is 2.5 nmol/l. This procedure has been used to quantitatively measure concentration versus time profiles of floxuridine and fluorouracil in plasma and peritoneal fluid of human patients after receiving intraperitoneal administration of floxuridine.  相似文献   

17.
The construction of an electrochemical detector flow cell for high-performance liquid chromatography from stainless steel, which also serves as the auxiliary electrode, is described. Glassy carbon is used for the working electrode in a novel configuration based on a hybrid of the wall-jet and thin-layer arrangements. Application of the detector to the determination of morphine in small blood samples is described. The metabolite, morphine-3-glucuronide, is also determined by hydrolysis with beta-glucoronidase prior to extraction. The detector is capable of detecting less than 1 ng of morphine injected.  相似文献   

18.
Morphine is one of the most effective agents for the control of significant pain, primarily metabolized to morphine‐3‐glucuronide (M3G) and morphine‐6‐glucuronide (M6G). While M6G is a potent opioid agonist, M3G has no opioid action and seems to have a role in side‐effects caused by morphine. In this study, a reversed‐phase high‐performance liquid chromatographic method with diode‐array and electrochemical detection was developed for the simultaneous determination of morphine, M3G and M6G in antemortem and postmortem samples (plasma, whole blood, urine, liver, kidney and brain). Morphine, glucuronides and internal standard were extracted by double solid‐phase extraction and the separation was carried out with a Waters Spherisorb® ODS2 reversed‐phase column and potassium phosphate buffer (pH = 2.2)–acetonitrile containing sodium dodecyl sulfate as the mobile phase. The method proved to be specific with good linearity for all analytes in a calibration range from 1 to 600 ng/mL and proved to be accurate and have adequate precision and recovery. Limits of detection in the studied matrices were 0.4–4.5 ng/mL for morphine, 2.7–6.1 ng/mL for M3G and 0.8–4.4 ng/mL for M6G. The proposed method can be successfully applied to quantify morphine and its metabolites in several biological samples, covering the major routes of distribution, metabolism and elimination of morphine. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
《Analytical letters》2012,45(18):2728-2736
A portable immuno-microchip system consisting of low-cost biocompatible-polystyrene chips, a mini-vacuum pump, and a base unit for a LED light source as a miniaturized optical readout was devised. The surfaces of the micro-channels were processed with plasma to be more hydrophilic and were characterized by kinetic coating with a CCD scanning method. To demonstrate the feasibility of this novel system for the determination of a small molecule control assay, a simple, specific, and rapid method was established for drug analysis of morphine and its analogs, 6-monoacetylmorphine and morphine-3-glucuronide. Morphine-3-site antigen and a multi-target polyclonal antibody to morphine and derivatives were prepared and a competitive immunoassay was performed on the chip. The measurement can be carried out automatically and avoids time-consuming incubation steps. A detection sensitivity of below 1.0 ng/mL was achieved, which is comparable with the enzyme-linked immunosorbent assay (ELISA) technique.  相似文献   

20.
The absorption characteristics of morphine were investigated by using rat gastrointestine. Absorption and transport experiments were carried out by the in situ loop and the in vitro everted sac methods, respectively. Brush border membrane vesicles (BBMVs) were used for uptake experiments. Morphine and its metabolites, morphine-3-glucuronide (M-3-G), and morphine-6-glucuronide (M-6-G), in biological samples were simultaneously determined by high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection and electrochemical detection. In the in situ loop method, morphine was well absorbed in the order of jejunal site greater than duodenal site greater than ileal site greater than middle intestinal site greater than rectal site, but it was poorly absorbed from the stomach. In each of the everted duodenal and jejunal sacs, 2,4-dinitrophenol, a metabolic inhibitor, inhibited the transport of morphine from the mucosal side to the serosal side. Further, HgCl2 pretreatment reduced the absorption of morphine from the duodenal and the jejunal loops. The initial uptake of morphine by BBMVs was stimulated in the presence of an H+ gradient (inner pH 7.5 and outer pH 5.0) and an overshoot phenomenon was observed. The initial uptake showed concentration dependence, i.e., it was saturable. Results obtained in this study indicate that carrier-mediated transport stimulated by the H+ gradient is partly involved in the duodeno-jejunal absorption of morphine, although morphine is passively absorbed from other sites.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号