首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Analysis of drugs in hair is often used as a routine method to obtain detailed information about drug ingestion. However, few studies have been conducted on deposition of synthetic cannabinoids and metabolites in hair. The first purpose of this study was to establish and validate an analytical method for detection of JWH-018, JWH-073, and their metabolites in hair, by use of UHPLC–MS–MS, for forensic application. The second purpose was to investigate the distribution of synthetic cannabinoids metabolites in hair and the effect of hair pigmentation, by use of an animal model. For this, JWH-073 was chosen as a representative synthetic cannabinoid. Finally, the developed method was applied to hair samples from 18 individuals suspected of synthetic cannabinoids use. JWH-018, JWH-073, and their metabolites were extracted from hair with methanol. The extract was then filtered and analyzed by UHPLC–MS–MS with an electrospray ion source in positive-ionization mode. Validation proved the method was selective, sensitive, accurate, and precise, with acceptable linearity within the calibration ranges. No significant variations were observed when different sources of both human and rat hair were used. The animal study demonstrated that JWH-073 N-COOH M was the major metabolite of JWH-073 in rat hair, and hair pigmentation did not have a significant effect on incorporation of JWH-073 and its metabolites into hair. In the analysis of 18 authentic hair samples, only JWH-018, JWH-018 N-5-OH M, and JWH-073 were detected, with wide variation in concentrations.  相似文献   

2.
The objective of this study was to compare the performance of an immunoassay screening for synthetic cannabinoids with a newly developed confirmation method using liquid chromatography quadrupole time-of-flight mass spectrometry. The screening included metabolites from JWH-018, JWH-073, and AM-2201. The confirmation included metabolites from AM-2201, JWH-018, JWH-019, JWH-073, JWH-081, JWH-122, JWH-210, JWH-250, JWH-398, MAM-2201, RCS-4, and UR-144. The immunoassay was tested and found to have no cross-reactivity with UR-144 metabolites but considerable cross-reactivity with MAM-2201 and JWH-122 metabolites. Sensitivity and specificity for the immunoassay were evaluated with 87 authentic urine samples and found to be 87 % and 82 %, respectively. With a cutoff at 2 ng/ml, the confirmation showed 80 positive findings in 38 cases. The most common finding was JWH-122 5-OH-pentyl, followed by JWH-018 5-OH-pentyl. There were 9 findings of UR-144 metabolites and 3 of JWH-073 metabolites. In summary, the immunoassay performed well, presenting both high sensitivity and specificity for the synthetic cannabinoids present in the urine samples tested. The rapid exchange of one cannabinoid for another may pose problems for immunoassays as well as for confirmation methods. However, we consider time-of-flight mass spectrometry to be superior since new metabolites can be quickly included and identified.
Figure
Spice metabolites in urine  相似文献   

3.
Popularity of new psychoactive substances, known as legal highs or herbal highs, is continuously growing. These products are typically sold via internet and in so-called head shops. The aim of this study was to identify active ingredients of herbal highs and to compare their chemical composition. Twenty-nine various products seized by the police in one of the “head shops” were analysed. Herbal mixtures (0.2 g) were prepared by ultrasonic-assisted extraction with 2.0 ml of ethanol for 2 h. The extracts were analysed by gas chromatography coupled to mass spectrometry (GC/MS). The main active compounds of the herbal mixtures were synthetic cannabinoids: JWH-018, JWH-073 and cannabicyclohexanol (CP-47,497-C8-homolog). Their content differed between the products; some contained only one cannabinoid whereas the others contained two or more. Cluster analysis and principal component analysis revealed that chemical composition of many products was very similar. The similarity was connected with their flavour and not the common name. This statement was true for the synthetic cannabinoids, other potential agonists of cannabinoid receptors (amides of fatty acids) and ingredients of natural origin and confirms that herbal highs are a threat to human health because the purchaser has no information on their real composition.  相似文献   

4.
采用气相色谱-质谱(GC-MS)结合准确质量测定方法,利用保留指数、特征碎片丰度以及高分辨准确质量数据信息,快速鉴定样品中的合成大麻素组分。建立了JWH-018、JWH-073等12种合成大麻素标准物质的分析信息数据库,检测限达到了2.5~30 ng/mL,并成功利用该方法对未知样品进行了检测,确认样品中含有“JWH-081和JWH-018”合成大麻素组分。结果表明方法可以满足合成大麻素快速鉴定的要求。  相似文献   

5.
作为第三代毒品中重要的一类, 合成大麻素类新精神活性物质被当做大麻的替代品而滥用严重, 已经引起社会的广泛关注.基于液相色谱-质谱联用技术的优势与特点, 建立了毛发样品中JWH-073、MAM-2201、JWH-015、JWH-203、JWH-018、JWH-007等6种合成大麻素类新精神活性物质的液相色谱-电喷雾离子阱质谱联用定性、定量分析方法.毛发样品经剪段、清洗后, 用甲醇超声提取, 进样分析, 6种目标化合物的质量浓度在3~200 ng/mg之间具有良好的线性关系, 相关系数大于0.990 1, 定量限小于3 ng/mg, 检出限小于1 ng/mg, 精密度小于9.99%, 提取回收率为90.69%~97.88%.建立的方法样品处理简便、检测灵敏度高、专属性强、重现性好, 可为打击新型毒品违法犯罪活动, 遏制新型毒品蔓延提供科学理论依据与技术支持, 具有重要的现实意义.  相似文献   

6.
After the discovery of synthetic cannabimimetic substances in 'Spice'-like herbal mixtures marketed as 'incense' or 'plant fertilizer' the active compounds have been declared as controlled substances in several European countries. As expected, a monitoring of new herbal mixtures which continue to appear on the market revealed that shortly after control measures have been taken by legal authorities, other compounds were added to existing mixtures and to new products. Several compounds of the aminoalkylindole type have been detected so far in herbal mixtures but still their consumption cannot be detected by commonly used drug-screening procedures, encouraging drug users to substitute cannabis with those products. There is a increasing demand on the part of police authorities, hospitals and psychiatrists for detection and quantification of synthetic cannabinoids in biological samples originating from psychiatric inpatients, emergency units or assessment of fitness to drive. Therefore, a liquid chromatography-tandem mass spectrometry method after liquid-liquid extraction for the quantitation of JWH-015, JWH-018, JWH-073, JWH-081, JWH 200, JWH-250, WIN 55,212-2 and methanandamide and the detection of JWH-019 and JWH-020 in human serum has been developed and fully validated according to guidelines for forensic toxicological analyses. The method was successfully applied to 101 serum samples from 80 subjects provided by hospitals, detoxification and therapy centers, forensic psychiatric centers and police authorities. Fifty-seven samples or 56.4% were found positive for at least one aminoalkylindole. JWH-019, JWH-020, JWH-200, WIN 55,212-2 and methanandamide were not detected in any of the analyzed samples.  相似文献   

7.
8.
As recently reported, the synthetic cannabinoid JWH-018 is the subject of extensive phase I and II metabolic reactions in vivo. Since these studies were based on LC-MS/MS and/or GC-MS identification and characterisation of analytes, the explicit structural assignment of the metabolites was only of preliminary nature, if possible at all. Here, we report the chemical synthesis of five potential in vivo metabolites of JWH-018 derivatives featuring an alkylcarboxy (M1), a terminal alkylhydroxy (M2), a 5-indolehydroxy (M3), an N-dealkylated 5-indolehydroxy (M4) and a 2′-naphthylhydroxy (5) analogue, respectively, and their characterisation by nuclear magnetic resonance spectroscopy. The collision-induced dissociation (CID) patterns of the protonated compounds were studied by high-resolution/high-accuracy tandem mass spectrometry (MS n ) applying an LTQ Orbitrap with direct infusion and electrospray ionisation of target analytes. An unusual dissociation behaviour including a reversible ion–molecule reaction between a naphthalene cation (m/z 127) and water in the gas phase of the MS was shown to be responsible for nominal neutral losses of 10 u in the course of the CID pathway. LC-MS/MS-supported comparison of synthesised reference standards with an authentic urine sample using an API 4000 QTrap mass spectrometer identified the synthetic JWH-018 analogues M1–M4 as true in vivo metabolites, presuming a chromatographic separation of potentially present regioisomeric analogues. Existing doping control methods were expanded and validated according to international guidelines in order to allow for the detection of the carboxy and the alkylhydroxy metabolites, respectively, as urinary markers for the illegal intake of the synthetic cannabinoid JWH-018. Both metabolites were quantified in authentic doping control urine samples that had been suspicious of JWH-018 abuse after routine screening procedures, and a stable isotope-labelled 13C8-15N-carboxy metabolite was synthesised for future analytical applications.  相似文献   

9.
Combined delta2H, delta13C and delta15N isotopic analysis of MDA and MDMA extracted from seized "ecstasy" tablets provides an isotopic "fingerprint" of the active ingredient allowing individual tablets to be linked to a common batch. Correlating these data with 2H NMR analysis of the extracts has the potential to study both the natural precursor materials and synthetic pathways used in the preparation of MDA and N-substituted homologues.  相似文献   

10.
The analysis of synthetic cannabinoids in human matrices is of particular importance in the fields of forensic and clinical toxicology since cannabis users partly shift to the consumption of ‘herbal mixtures’ as a legal alternative to cannabis products in order to circumvent drug testing. However, comprehensive methods covering the majority of synthetic cannabinoids already identified on the drug market are still lacking. In this article, we present a fully validated method for the analysis of 30 synthetic cannabinoids in human serum utilizing liquid‐liquid extraction and liquid chromatography‐electrospray ionization tandem mass spectrometry. The method proved to be suitable for the quantification of 27 substances. The limits of detection ranged from 0.01 to 2.0 ng/mL, whereas the lower limits of quantification were in the range from 0.1 to 2.0 ng/mL. The presented method was successfully applied to 833 authentic serum samples during routine analysis between August 2011 and January 2012. A total of 227 (27%) samples was tested positive for at least one of the following synthetic cannabinoids: JWH‐018, JWH‐019, JWH‐073, JWH‐081, JWH‐122, JWH‐200, JWH‐203, JWH‐210, JWH‐307, AM‐2201 and RCS‐4. The most prevalent compounds in positive samples were JWH‐210 (80%), JWH‐122 (63%) as well as AM‐2201 (29%). Median serum concentrations were all below 1.0 ng/mL. These findings demonstrate a significant shift of the market of synthetic cannabinoids towards substances featuring a higher CB1 binding affinity and clearly emphasize that the analysis of synthetic cannabinoids in serum or blood samples requires highly sensitive analytical methods covering a wide spectrum of substances. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
The use of sub-2?µm particles columns is finding its use in ultrahigh-pressure supercritical fluid chromatography (UHPSFC), opening up for fast analysis and high-resolution separations. The development of new and more robust systems also makes the technique more interesting for bioanalytical analysis, where the need for reproducible and fast analysis with little downtime is great. One area where the use of UHPSFC could become a useful tool is in the separation of structural isomers of new psychoactive substances (NPS). 2-, 3-, and 4- structural isomers of fluoroamphetamine, fluoromethamphetamine, and methylmethcathinone, isomeric pairs of the synthetic cannabinoids UR-144/UR-144 degradant, XLR-11/XLR-11 degradant, JWH-015/JWH-073, and JWH-019/JWH-122, as well as amphetamine and several stable isotope-labeled amphetamine internal standards were separated with UHPSFC-MS/MS and compared with ultrahigh-pressure liquid chromatography (UHPLC) MS/MS. NPS isomers that were difficult to separate with reversed-phase UHPLC-MS/MS were separated by UHPSFC; in most cases with an orthogonal retention order to UHPLC. In contrast to the behavior seen when using reversed-phase UHPLC, the deuterated amphetamines eluted later than amphetamine with UHPSFC. 13C6-labeled amphetamine coeluted with amphetamine for all conditions, making this the best choice of an internal standard.  相似文献   

12.
Herbal mixtures, such as ‘Spice’, containing cannabimimetic compounds are easily available on the Internet and have become increasingly popular among people having to undergo urine drug testing, as these compounds are not detected by current immunochemical tests. For analysis of urine samples, knowledge of the main metabolites is necessary as the unchanged compounds are usually not found in urine after consumption. In this paper, the identification of the major metabolites of the currently most common seven synthetic cannabinoids is presented. Urine samples from patients of psychiatric facilities known to have consumed synthetic cannabinoids were screened by LC‐MS/MS and HR‐MS/MS techniques, and the major metabolites for each of the following synthetic cannabinoids were identified by their enhanced product ion spectra and accurate mass measurement: JWH‐018, JWH‐073, JWH‐081, JWH‐122, JWH‐210, JWH‐250 and RCS‐4. The major metabolic pathway is monohydroxylation either at the N‐alkyl side chain, the naphthyl moiety or the indole moiety. In addition, metabolites with carboxylated alkyl chains were identified for some of the compounds. These results facilitate the design of urine screening methods for detecting consumption of synthetic cannabinoids. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
A new cannabimimetic phenylacetylindole (cannabipiperidiethanone, 1) has been found as an adulterant in a herbal product which contains two other known synthetic cannabinoids, JWH-122 and JWH-081, and which is distributed illegally in Japan. The identification was based on analyses using GC-MS, LC-MS, high-resolution MS and NMR. Accurate mass spectrum measurement showed the protonated molecular ion peak of 1 at m/z 377.2233 [M+H]? and the molecular formula of 1 was C??H??N?O?. Both mass and NMR spectrometric data revealed that 1 was 2-(2-methoxyphenyl)-1-{1-[(1-methylpiperidin-2-yl)methyl]-1H-indol-3-yl}ethanone. Compound 1 has a mixed structure of known cannabimimetic compounds: JWH-250 and AM-2233. Namely, the moiety of phenylacetyl indole and N-methylpiperidin-2-yl-methyl correspond to the structure of JWH-250 and AM-2233, respectively. However, no synthetic, chemical or biological information about 1 has been reported. A binding assay of compound 1 to cannabinoid receptors revealed that 1 has affinity for the CB? and CB? (IC??=591, 968 nM, respectively) receptors, and shows 2.3- and 9.4-fold lower affinities than those of JWH-250. This is the first report to identify cannabimimetic compound (1) as a designer drug and to show its binding affinity to cannabinoid receptors.  相似文献   

14.
Since 2004, a number of herbal blends containing different synthetic compounds mimicking the pharmacological activity of cannabinoids and displaying a high toxicological potential have appeared in the market. Their availability is mainly based on the so‐called “e‐commerce”, being sold as legal alternatives to cannabis and cannabis derivatives. Although highly selective, sensitive, accurate, and quantitative methods based on GC–MS and LC–MS are available, they lack simplicity, rapidity, versatility and throughput, which are required for product monitoring. In this context, matrix‐assisted laser desorption ionization‐time of flight mass spectrometry (MALDI‐TOF MS) offers a simple and rapid operation with high throughput. Thus, the aim of the present work was to develop a MALDI‐TOF MS method for the rapid qualitative direct analysis of herbal blend preparations for synthetic cannabinoids to be used as front screening of confiscated clandestine preparations. The sample preparation was limited to herbal blend leaves finely grinding in a mortar and loading onto the MALDI plate followed by addition of 2 µl of the matrix/surfactant mixture [α‐cyano‐4‐hydroxy‐cinnamic acid/cetyltrimethylammonium bromide (CTAB)]. After drying, the sample plate was introduced into the ion source for analysis. MALDI‐TOF conditions were as follows: mass spectra were analyzed in the range m/z 150–550 by averaging the data from 50 laser shots and using an accelerating voltage of 20 kV. The described method was successfully applied to the screening of 31 commercial herbal blends, previously analyzed by GC–MS. Among the samples analyzed, 21 contained synthetic cannabinoids (namely JWH‐018, JWH‐073, JWH‐081, JWH‐250, JWH‐210, JWH‐019, and AM‐694). All the results were in agreement with GC–MS, which was used as the reference technique. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
The continuing emergence of designer drugs imposes high demands on the scope and sensitivity of toxicological drug screening procedures. An ultra-high performance liquid chromatography/high-resolution time-of-flight mass spectrometry (UHPLC-HR-TOFMS) method was developed for screening and simultaneous confirmation of both designer drugs and other drugs of abuse in urine samples in a single run. The method covered selected synthetic cannabinoids and cathinones, amphetamines, natural cannabinoids, opioids, cocaine and other important drugs of abuse, together with their main urinary metabolites. The database consisted of 277 compounds with molecular formula and exact monoisotopic mass; retention time was included for 192 compounds, and primary and secondary qualifier ion exact mass for 191 and 95 compounds, respectively. Following a solid-phase extraction, separation was performed by UHPLC and mass analysis by HR-TOFMS. MS, and broad-band collision-induced dissociation data were acquired at m/z range 50–700. Compound identification was based on a reverse database search with acceptance criteria for retention time, precursor ion mass accuracy, isotopic pattern and abundance of qualifier ions. Mass resolving power in spiked urine samples was on average FWHM 23,500 and mass accuracy 0.3 mDa. The mean and median cut-off concentrations determined for 75 compounds were 4.2 and 1 ng/mL, respectively. The range of cut-off concentrations for synthetic cannabinoids was 0.2–60 ng/mL and for cathinones 0.7–15 ng/mL. The method proved to combine high sensitivity and a wide scope in a manner not previously reported in drugs of abuse screening. The method’s feasibility was demonstrated with 50 authentic urine samples.
Figure
Extracted ion chromatograms of metabolites of synthetic cannabinoids and their fragments, including a new common metabolite: JWH-072-propanoic acid  相似文献   

16.
Synthetic cathinones are novel stimulants derived from cathinone, with amphetamines or cocaine-like effects, often labeled “not for human consumption” and considered “legal highs”. Emergence of these new designer drugs complicate interpretation of forensic and clinical cases, with introduction of many new analogs designed to circumvent legislation and vary effects and potencies. We developed a method for the simultaneous quantification of 28 synthetic cathinones, including four metabolites, in urine by liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS). These cathinones include cathinone, methcathinone, and synthetic cathinones position-3’-substituted, N-alkyl-substituted, ring-substituted, methylenedioxy-substituted, and pyrrolidinyl-substituted. One mL phosphate buffer pH 6 and 25 μL IStd solution were combined with 0.25 mL urine, and subjected to solid phase cation exchange extraction (SOLA SCX). The chromatographic reverse-phase separation was achieved with a gradient mobile phase of 0.1 % formic acid in water and in acetonitrile in 20 min. We employed a Q Exactive high resolution mass spectrometer, with compounds identified and quantified by target-MSMS experiments. The assay was linear from 0.5–1 to 100 μg/L, with limits of detection of 0.25–1 μg/L. Imprecision (n?=?20) was <15.9 % and accuracy (n?=?20) 85.2–118.1 %. Extraction efficiency was 78.9–116.7 % (CV 1.4–16.7 %, n?=?5), process efficiency 57.7–104.9 %, and matrix effects from ?29.5 % to 1.5 % (CV 1.9–13.1 %, n?=?10). Most synthetic cathinones were stable at 4 °C for 72 h (n?=?27) and after 3 freeze-thaw cycles (n?=?26), but many (n?=?19) were not stable at room temperature for 24 h (losses up to ?67.6 %). The method was applied to authentic urine specimens from synthetic cathinone users. This method provides a comprehensive confirmation method for 28 synthetic cathinones in urine, with good selectivity and specificity.  相似文献   

17.
This pilot study was performed to study the main metabolic reactions of four synthetic cannabinoids: JWH-015, JWH-098, JWH-251, and JWH-307 in order to setup a screening method for the detection of main metabolites in biological fluids. In silico prediction of main metabolic reactions was performed using MetaSite? software. To evaluate the agreement between software prediction and experimental reactions, we performed in vitro experiments on the same JWHs using rat liver slices. The obtained samples were analyzed by liquid chromatography-quadrupole time-of-flight and the identification of metabolites was executed using Mass-MetaSite? software that automatically assigned the metabolite structures to the peaks detected based on their accurate masses and fragmentation. A comparison between the experimental findings and the in silico metabolism prediction using MetaSite? software showed a good accordance between experimental and in silico data. Thus, the use of in silico metabolism prediction might represent a useful tool for the forensic and clinical toxicologist to identify possible main biomarkers for synthetic cannabinoids in biological fluids, especially urine, following their administration.
Figure
JWH-098: Most probable predicted sites of metabolism and main metabolites formed in vitro  相似文献   

18.
Smoking mixtures containing cannabimimetic indoles may still be illegally sold in Russia. Although a method for their analysis is required for forensic toxicology authorities, the detection of synthetic cannabinoids is a complicated analytical task because of low anticipated concentrations in urine and the lack of in vivo data on their metabolism. Here, the urinary metabolites of 1-pentyl-3-(1-naphthoyl)indole (JWH-018) and a procedure for determining them in urine are reported. Using gas and high-performance liquid chromatography combined with tandem mass spectrometry, two main monohydroxylated metabolites were identified in urine. Based on differences in their electron ionization MS/MS spectra, it is supposed that one of them is formed by the hydroxylation of an indole ring and the other, by the hydroxylation of a pentyl side chain. The main metabolites are almost completely excreted as conjugates with glucuronic acid. The structure of minor metabolites was proposed. The parent compound was not detected in urine at a level of 50 pg/mL 12 h after administration.  相似文献   

19.
A potent synthetic cannabinoid receptor agonist, JHW-018, was recently detected as one of the most prominent active agents in abusively used incenses such as Spice and other herbal blends. The high pharmacological and addictive potency of JWH-018 highlights the importance of elucidating the metabolism of JWH-018, without which a meaningful insight into its pharmacokinetics and its toxicity would not be possible. In the present study, the cytochrome P450 phase I metabolites of JWH-018 were investigated, after in vitro incubation of the drug with human liver microsomes, followed by liquid chromatography–tandem mass spectrometry analysis. This revealed monohydroxylation of the naphthalene ring system, the indole moiety, and the alkyl side chain. In addition, observations were made of dihydroxylation of the naphthalene ring system, and the indole moiety, or as result of a combination of monohydroxylations of both the naphthalene ring system and the indole moiety or the alkyl side chain, or a combination of monohydroxylations of both the indole ring system and the alkyl side chain. There is also evidence of trihydroxylation at different locations of the hydroxyl groups in the molecule. Furthermore, dehydration of the alkyl side chain, in combination with both monohydroxylation and dihydroxylation as well as arene oxidation of the naphthalene ring system, combined with both monohydroxylation and dihydroxylation at different sites of oxidation were found. N-dealkylation also in combination with both monohydroxylation and dihydrodiol formation of the N-dealkylated metabolite was detected. Finally, a metabolite was found carboxylated at the alkyl side chain.  相似文献   

20.
A simple procedure for the quantitative detection of JWH‐018, JWH‐073, JWH 200, JWH‐250, HU‐210, Δ9‐tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN) in hair has been developed and fully validated. After digestion with NaOH and liquid–liquid extraction, the separation was performed with an ultra‐high performance liquid chromatography system coupled to a triple quadrupole mass spectrometer operating in the selected reaction monitoring mode. The absence of matrix interferents, together with excellent repeatability of both retention times and relative abundances of diagnostic transitions, allowed the correct identification of all analytes tested. The method was linear in two different intervals at low and high concentration, with correlation coefficient values between 0.9933 and 0.9991. Quantitation limits ranged from 0.07 pg/mg for JWH‐200 up to 18 pg/mg for CBD The present method for the determination of several cannabinoids in hair proved to be simple, fast, specific and sensitive. The method was successfully applied to the analysis of 179 real samples collected from proven consumers of Cannabis, among which 14 were found positive to at least one synthetic cannabinoid. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号