 共查询到20条相似文献,搜索用时 15 毫秒
1.
It has become increasingly popular in drug development to conduct discovery pharmacokinetic (PK) studies in order to evaluate important PK parameters of new chemical entities (NCEs) early in the discovery process. In these studies, dosing vehicles are typically employed in high concentrations to dissolve the test compounds in dose formulations. This can pose significant problems for the liquid chromatography/tandem mass spectrometric (LC/MS/MS) analysis of incurred samples due to potential signal suppression of the analytes caused by the vehicles. In this paper, model test compounds in rat plasma were analyzed using a generic fast gradient LC/MS/MS method. Commonly used dosing vehicles, including poly(ethylene glycol) 400 (PEG 400), polysorbate 80 (Tween 80), hydroxypropyl beta-cyclodextrin, and N,N-dimethylacetamide, were fortified into rat plasma at 5 mg/mL before extraction. Their effects on the sample analysis results were evaluated by the method of post-column infusion. Results thus obtained indicated that polymeric vehicles such as PEG 400 and Tween 80 caused significant suppression (> 50%, compared with results obtained from plasma samples free from vehicles) to certain analytes, when minimum sample cleanup was used and the analytes happened to co-elute with the vehicles. Effective means to minimize this 'dosing vehicle effect' included better chromatographic separations, better sample cleanup, and alternative ionization methods. Finally, a real-world example is given to illustrate the suppression problem posed by high levels of PEG 400 in sample analysis, and to discuss steps taken in overcoming the problem. A simple but effective means of identifying a 'dosing vehicle effect' is also proposed.  相似文献   

2.
A series of studies was performed to investigate some of the causes for matrix effects ('ion suppression' or 'ion enhancement') in bioanalytical high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) assays. Previous studies have reported that matrix effects are mainly due to endogenous components in biological fluids and are a greater concern for electrospray ionization (ESI) than for atmospheric pressure chemical ionization (APCI). In this report we demonstrate that: (1) matrix effects can also be caused by exogenous materials, such as polymers contained in different brands of plastic tubes, or Li-heparin, a commonly used anticoagulant; (2) matrix effects are not only ionization mode (APCI or ESI) dependent, but also source design (Sciex, Finnigan, Micromass) dependent; and (3) for at least one vendor's design, we found the APCI mode to be more sensitive to matrix effects than the ESI mode. Based on these findings, we have proposed the following simple strategies to avoid matrix effects: (1) select the same brand of plastic tubes for processing and storing plasma samples and spiked plasma standards; (2) avoid using Li-heparin as the anticoagulant; and (3) try switching the ionization mode or switching to different mass spectrometers when matrix effects are encountered. These three strategies have allowed us to use protein precipitation and generic fast LC techniques to generate reliable LC/MS/MS data for the support of pharmacokinetic studies at the early drug discovery stage.  相似文献   

3.
Measurement of test article concentration in tissue samples has been an important part of pharmacokinetic study and has helped to co‐relate pharmacokinetic/pharmacodynamic relationships since the 1950s. Bioanalysis of tissue samples using LC–MS/MS comes with unique challenges in terms of sample handling and inconsistent analyte response owing to nonvolatile matrix components. Matrix effect is a phenomenon where the target analyte response is either suppressed or enhanced in the presence of matrix components. Based on previous reports electrospray ionization (ESI) mode of ionization is believed to be more affected by matrix components than atmospheric pressure chemical ionization (APCI) or atmospheric pressure photoionization. To explore the impact of ionization source with respect to bioanalysis of tissue samples, five structurally diverse compounds – atenolol, verapamil, diclofenac, propranolol and flufenamic acid – were selected. Quality control standards were spiked into 10 different biological matrices like whole blood, liver, heart, brain, spleen, kidney, skeletal muscle, eye and skin tissue and were quantified against calibration standards prepared in rat plasma. Quantitative bioanalysis was performed utilizing both APCI and ESI mode and results were compared. Quality control standards when analyzed with APCI mode were found to be more consistent in terms of accuracy and precision as compared with ESI mode. Additionally, for some instances, up to 20‐fold broader dynamic linearity range was observed with APCI mode as compared with ESI mode. As phospholid interferences have poor response in APCI mode, protein precipitation extraction technique can be used for multimatrix quantitation, which is more amenable to automation. The approach of multiple biological matrix quantitation against a single calibration curve helps bioanalysts to reduce turnaround time. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

4.
The applicability of three different ionization techniques: atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) was tested for the liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of five target pharmaceuticals (cyclophosphamide, methotrexate, bezafibrate, enalapril and orlistat) in wastewater samples. Performance was compared both by flow injection analysis (FIA) and on-column analysis in deionized water and wastewater samples. A column switching technique for the on-line extraction and analysis of water samples was used. For both FIA and on-column analysis, signal intensity and signal-to-noise (S/N) ratio of the target analytes in the three sources were studied. Limits of detection and matrix effects during the analysis of wastewater samples were also investigated. ESI generated significantly larger peak areas and higher S/N ratios than APCI and APPI in FIA and in on-column analysis. ESI was proved to be the most suitable ionization method as it enabled the detection of the five target compounds, whereas APCI and APPI ionized only four compounds.  相似文献   

5.
The performance of the atmospheric pressure photoionization (APPI) technique was evaluated against five sets of standards and drug-like compounds and compared to atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The APPI technique was first used to analyze a set of 86 drug standards with diverse structures and polarities with a 100% detection rate. More detailed studies were then performed for another three sets of both drug standards and proprietary drug candidates. All 60 test compounds in these three sets were detected by APPI with an overall higher ionization efficiency than either APCI or ESI. Most of the non-polar compounds in these three sets were not ionized by APCI or ESI. Analysis of a final set of 201 Wyeth proprietary drug candidates by APPI, APCI and ESI provided an additional comparison of the ionization techniques. The detection rates in positive ion mode were 94% for APPI, 84% for APCI, and 84% for ESI. Combining positive and negative ion mode detection, APPI detected 98% of the compounds, while APCI and ESI detected 91%, respectively. This analysis shows that APPI is a valuable tool for day-to-day usage in a pharmaceutical company setting because it is able to successfully ionize more compounds, with greater structural diversity, than the other two ionization techniques. Consequently, APPI could be considered a more universal ionization method, and therefore has great potential in high-throughput drug discovery especially for open access liquid chromatography/mass spectrometry (LC/MS) applications.  相似文献   

6.
Mass spectrometry of ochratoxin A (OTA) and B (OTB) under electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) was studied. ESI offers higher sensitivities and less fragmentation than APCI. A sensitive LC/MS/MS method for the determination of ochratoxin A (OTA) in human plasma samples was developed. The absolute minimum detection limit was around 10-20 pg per injection, corresponding to 0.5 ppb in an injection equivalent to 20-40microg of human plasma. Ochratoxin B (OTB) was used as an internal standard and its absence in real-life samples was carefully checked before samples were spiked with the internal standard. It was found that these two ochratoxins are susceptible to sodium adduct formation. Fragment ions from the [M + H](+) and [M + Na](+) ions of both OTA and OTB were monitored in the multiple reaction monitoring mode. Three quantitative approaches, standard addition method, internal standard method (using ochratoxin B as an internal standard) and external standard method, were compared in the analysis of human blood plasma. Results from the mass spectrometric method were comparable to those from a conventional LC/fluorescence method. The LC/MS/MS method was also applied to the analysis of contaminated coffee samples.  相似文献   

7.
Gas chromatography/mass spectrometry (GC/MS) is applied to the analysis of volatile and thermally stable compounds, while liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) and liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) are preferred for the analysis of compounds with solution acid‐base chemistry. Because organic explosives are compounds with low polarity and some of them are thermally labile, they have not been very well analyzed by GC/MS, LC/APCI‐MS and LC/ESI‐MS. Herein, we demonstrate liquid chromatography/negative ion atmospheric pressure photoionization mass spectrometry (LC/NI‐APPI‐MS) as a novel and highly sensitive method for their analysis. Using LC/NI‐APPI‐MS, limits of quantification (LOQs) of nitroaromatics and nitramines down to the middle pg range have been achieved in full MS scan mode, which are approximately one order to two orders magnitude lower than those previously reported using GC/MS or LC/APCI‐MS. The calibration dynamic ranges achieved by LC/NI‐APPI‐MS are also wider than those using GC/MS and LC/APCI‐MS. The reproducibility of LC/NI‐APPI‐MS is also very reliable, with the intraday and interday variabilities by coefficient of variation (CV) of 0.2–3.4% and 0.6–1.9% for 2,4,6‐trinitrotoluene (2,4,6‐TNT). Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
Capillary electrophoresis/mass spectrometry (CE/MS) is predominantly carried out using electrospray ionization (ESI). Recently, atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) have become available for CE/MS. With the VUV lamp turned off, the APPI source may also be used for CE/MS by thermospray ionization (TSI). In the present study the suitability of ESI, APCI, APPI and TSI for drug impurity profiling by CE/MS in the positive ion mode is evaluated. The drugs carbachol, lidocaine and proguanil and their potential impurities were used as test compounds, representing different molecular polarities. A background electrolyte of 100 mM acetic acid (pH 4.5) provided baseline separation of nearly all impurities from the respective drugs. APPI yielded both even‐ and odd‐electron ions, whereas the other ionization techniques produced even‐electron ions only. In‐source fragmentation was more pronounced with APCI and APPI than with ESI and TSI, which was most obvious for proguanil and its impurities. In general, ESI and TSI appeared the most efficient ionization techniques for impurities that are charged in solution achieving detection limits of 100 ng/mL (full‐scan mode). APPI and APCI showed a lower efficiency, but allowed ionization of low and high polarity analytes, although quaternary ammonium compounds (e.g. carbachol) could not be detected. Largely neutral compounds, such as the lidocaine impurity 2,6‐dimethylaniline, could not be detected by TSI, and yielded similar detection limits (500 ng/mL) for ESI, APPI and APCI. In many cases, impurity detection at the 0.1% (w/w) level was possible when 1 mg/mL of parent drug was injected with at least one of the CE/MS systems. Overall, the tested CE/MS systems provide complementary information as illustrated by the detection and identification of an unknown impurity in carbachol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
The aim of this study was to evaluate the applicability of ECHO technique in pesticide residue analysis using LC/MS/MS instruments with atmospheric pressure chemical (APCI) and electrospray (ESI) ionization. The technique is based on simultaneous injections of reference standards and samples in one run. First and second injections are made ahead and behind a precolumn, respectively, thus resulting in a short difference of retention times between standard and sample peak. The obtained couple of peaks were applied to the easy detection of pesticides and simultaneous estimation of the residue content in real samples in a single run. If residues were not observed, the second sample peak did not occur and the ECHO peaks were used to demonstrate instrument performance in each run and for each analyte. Another advantage of ECHO technique is its potential to compensate matrix effects. The occurrence and compensation of matrix effects using APCI was tested with four matrix types (water containing, acidic, dry and sugar containing) and 22 pesticides. The same matrix types but 58 pesticides were used tests with electrospray ionization. Most often matrix effects had been observed with lemon. The percentage of pesticides showing significant matrix effects did not differ between APCI and ESI. But these effects caused signal enhancement in APCI measurements and signal suppression, when ESI was used. The ECHO technique was able to compensate many matrix effects in measurements with both types of ion sources.  相似文献   

10.
A rapid, sensitive and selective method based on LC-MS/MS has been developed for the direct determination of acrylamide residues in water in compliance with the current European Union (EU) 98/83 Drinking Water Directive. Given the high polarity of acrylamide, the application of a rapid on-line solid phase extraction step, commonly used for preconcentrating low analyte levels, was not found to be completely satisfactory. Therefore, an alternative approach based on the use of direct large-volume injection into the LC-MS/MS system has been used. Three atmospheric-pressure interfaces (ESI, APCI and Ion Sabre APCI) were checked to reach the required sensitivity (0.1 microg/l). All three interfaces were tested by analysis of six different water samples (surface water, groundwater, drinking water and three treated water samples) spiked at three concentration levels each (0.1, 1 and 10 microg/l). When using ESI, poor sensitivity and high matrix effects were observed. This situation improved when APCI was used as the interface because no matrix effect was found, although sensitivity was not completely satisfactory. The best results were obtained by interfacing the Ion Sabre APCI; its higher sensitivity for acrylamide (LOD 0.03 microg/l) and the absence of matrix effects recommended its selection. Using this approach, satisfactory recoveries (90-97%) and precision (<12%) were obtained for all water samples studied. Besides, the acquisition of two different MS/MS transitions allowed not only the quantification but also the confirmation of acrylamide in water at concentration levels around 0.1 microg/l.  相似文献   

11.
The API-MS signal response of several pesticides (atrazine, simazine, isoproturon, diuron, chlorfenvinphos, chlorpyrifos, alachlor, trifluralin) depending on the flow-rate of eluent entering the MS interface was investigated. The investigations were based on API-MS-MS analyses of standard pesticide mixtures in the flow injection mode (FIA) at systematically varied eluent flow-rates using both an ESI interface (Turboionspray) and a heated nebulizer type APCI source. In the result, the individual compounds included in this study showed significant differences in their signal response behaviour depending on the flow-rate of eluent applied. The most hydrophobic compounds among the investigated pesticides (chlorpyrifos and trifluralin) showed drastic losses of sensitivity with increasing eluent flow-rate in both ESI and APCI, while more hydrophilic compounds like atrazine, simazine and isoproturon showed the expected signal response (concentration-sensitive in ESI, mass-flow-sensitive in APCI) at least within a certain range of flow-rates (200-600 microl/min in ESI, 200-2000 microl/min in APCI). These findings lead to the conclusion that application of a programmed HPLC eluent flow-rate may be advantageous to achieve maximum sensitivity of API-MS detection for all pesticides of interest. This is exemplified by the implementation of a flow gradient into an online SPE-HPLC-APCI-MS/MS method for improved analysis of pesticides in drinking water.  相似文献   

12.
The purpose of the present work was to evaluate the synergistic effect of ionization type, sample preparation technique, and bio-fluid on the presence of matrix effect in quantitative liquid chromatography (LC)-MS/MS analysis of illicit drugs by post-column infusion experiments with morphine (10-microg/mL solution). Three bio-fluids (urine, oral fluid, and plasma) were pretreated with four sample preparation procedures [direct injection, dilution, protein precipitation, solid-phase extraction (SPE)] and analyzed by both LC-electrospray ionization (ESI)-MS/MS and LC-atmospheric pressure chemical ionization (APCI)-MS/MS. Our results indicated that both ionization types showed matrix effect, but ESI was more susceptible than APCI. Sample preparation could reduce (clean up) or magnify (pre-concentrate) matrix effect. Residual matrix components were specific to each bio-fluid and interfered at different time points in the chromatogram. We evaluated matrix effect in an early stage of method development and combined optimal ionization type and sample preparation technique for each bio-fluid. Simple dilution of urine was sufficient to allow for the analysis of the analytes of interest by LC-APCI-MS/MS. Acetonitrile protein precipitation provided both sample clean up and concentration for oral fluid analysis, while SPE was necessary for extensive clean up of plasma prior to LC-APCI-MS/MS.  相似文献   

13.
In this work, ten selected pesticides of different chemical groups, indicated to orange culture, were extracted and determined by liquid chromatography-mass spectrometry using both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) operating in the positive ion detection mode. Applying a variables selection technique verified that cone voltage, source temperature and drying-gas flow-rate are the critical variables when the ESI was used, while cone voltage was found to be the only critical variable for the MS system, operating with the APCI ionization mode. After optimization of the most important parameters through the variables selection technique, the selected ion-recording (SIR) mode, monitoring the [M + H](+) species for all the compounds, was applied for the method validation of the pesticides, in both ionization modes. In orange samples, matrix effects did not interfere with the determination of the pesticides. Pesticides quantification limits ranged from 10 to 50 microg kg(-1) for ESI and from 8.2 to 45 microg kg(-1) for APCI. Linearity was studied from LOQ upto 200 times LOQ values (r > 0.98). Recoveries obtained were in the range of 70.2-100.5% (RSDs less than 10%). In order to guarantee that the identification and confirmation of the studied pesticides in real samples were unequivocal, characteristic fragment ions of the pesticides were obtained by varying the cone voltage (in-source CID).  相似文献   

14.
Liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method for simultaneous and direct detection of 12 glucuronide-conjugated anabolic androgenic steroid (AAS) metabolites in human urine is described. The compounds selected were the main metabolites detected in human urine after dosing of the most widely abused AAS in sports, e.g. methandienone, methenolone, methyltestosterone, nandrolone and testosterone, and certain deuterium-labeled analogs of these metabolites. Sample preparation and the LC-ESI-MS/MS method were optimized, validated, and the overall process was implemented and the results between seven laboratories were compared. All the metabolites were extracted simultaneously by solid-phase extraction (SPE) and analyzed by LC-ESI-MS/MS with positive ionization mode and multiple reaction monitoring (MRM). Recovery of the SPE for the AAS glucuronides was 89-100% and ten out of twelve compounds had detection limits in the range of 1-10 ng/ml in urine. The results for inter/intraday repeatability were satisfactory and the interlaboratory comparison with authentic urine samples demonstrated the ease of method transfer from one instrument setup to another. When equivalent triple quadrupole analyzers were employed the overall performance was independent from instrument manufacturer, electrospray ionisation (ESI) or atmospheric pressure chemical ionization (APCI) and liquid chromatohraphic (LC) column, whereas major differences were encountered when changing from one analyzer type to another, especially in the analysis of those AAS glucuronides ionized mainly as adducts.  相似文献   

15.
We have investigated the composition of the mobile natural organic matter (NOM) present in Callovo‐Oxfodian pore water using electrospray ionization mass spectrometry (ESI‐MS), atmospheric pressure chemical ionization mass spectrometry (APCI‐MS) and emission‐excitation matrix (EEM) spectroscopy. The generation of knowledge of the composition, structure and size of mobile NOM is necessary if one wants to understand the interactions of these compounds with heavy metals/radionuclides, in the context of environmental studies, and particularly how the mobility of these trace elements is affected by mobile NOM. The proposed methodology is very sensitive in unambiguously identifying the in situ composition of dissolved NOM in water even at very low NOM concentration, due to innovative non‐disturbing water sampling and ionization (ESI/APCI‐MS) techniques. It was possible to analyze a quite exhaustive inventory of the small organic compounds of clay pore water without proceeding to any chemical treatment at naturally occurring concentration levels. The structural features observed were mainly acidic compounds and fatty acids as well as aldehydes and amino acids. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
A higher-throughput bioanalytical method based on fast-gradient (1 min run time) high-performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS/MS) was developed for screen-type analyses of plasma samples from early drug discovery studies in support of exploratory pharmacodynamic studies. The HPLC system equipped with minibore column was interfaced with either atmospheric pressure chemical ionization (APCI) or electrospray (ESI) ionization techniques. The matrix ion suppression effect of both quantitative HPLC/MS/MS analyses was compared using the post-column infusion system. The use of the described methods provided advantages such as a shorter chromatographic region of ion suppression, less solvent consumption and shorter run times in comparison with standard analytical column HPLC/MS/MS methods. The analytical results obtained by both HPLC/MS/MS methods were in good agreement (within 15% of error) and displayed a good correlation with the pharmacodynamic outcome.  相似文献   

17.
Dansyl-Pro-Gln-Arg-NH(2), an N-terminally modified tripeptide amide and a putative neuropeptide FF antagonist, was amenable to both positive-ion ESI and APCI. The protonated molecule yielded several fragment ions upon collision-induced dissociation in a quadrupole ion trap instrument for the development of LC/MS/MS assay methods. ESI clearly outperformed APCI in limits of detection, and was the method of choice for coupling with narrow-bore reversed-phase liquid chromatography to assess the pharmacokinetic profile and brain concentration of the neuropeptide FF antagonist in experimental animals. While plasma could be analyzed after rapid sample preparation, brain tissue required cleanup (solid phase extraction) and preconcentration before injection, and the assay was prone to matrix interference. This study indicated a rapid disappearance of dansyl-Pro-Gln-Arg-NH(2) from the plasma and the brain, and modest CNS bioavailability after intravenous administration to rats.  相似文献   

18.
Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) are the two most common mass spectrometric ionization methods used in the pharmaceutical industry. However, APCI analysis can sometimes lead to ambiguity in compound characterization and quantitation due to gas-phase reactions occurring between acetonitrile and water in the plasma, and between these plasma-generated compounds and the analyte. During the analysis of various sultams and sulfonamides we observed signals corresponding to m/z [M+44](+) and [M+60](+). Various solvent conditions and collisionally activated dissociation MS(n) experiments revealed that under the high-energy plasma conditions of APCI, the acetonitrile/water solvent mixture reacts undergoing acid-catalyzed hydrolysis producing acetamide, 59 Da. Further, the highly reactive 43 Da species ethanimine is also produced. These two compounds, normally not observed in APCI analysis, are stabilized by the sulfonamide and appear as adduct species in the mass spectra. The sulfone oxygens and the lone pair of electrons on the amide nitrogen play a role in stabilizing this adduct.  相似文献   

19.
A high-throughput method was developed and validated for the quantitative determination of MMI270B, an inhibitor of matrix metalloprotease (MMP) enzymes, in human plasma. The method was based on reverse-phase chromatographic separation of the analyte from plasma extract followed by atmospheric pressure chemical ionization (APCI) and tandem mass spectrometry in the selected reaction monitoring mode (SRM). Extraction was performed using simple protein fi ltration in the 96-well plate format to increase the throughput of the method. Optimised chromatographic separation in a short column (30 x 4.6 mm i.d.) coupled with positive APCI mode of ionization followed by selective SRM mode of detection yielded clean chromatograms with minimal signal suppression. The chromatographic conditions resolved isobaric interference peaks observed in samples from patients dosed with MMI270B. The standard curve was linear (r = 0.997) within the concentration range of 1.04 (lower limit of quanti fi cation) to 1040 ng/mL using 0.1 mL of human plasma. The accuracy of the method varied from 93.6 to 103% with a precision of 2.17-6.71% over the concentration range. The method was simple, rapid, and robust with an analyte recovery of >98%.  相似文献   

20.
The capabilities of atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) methods for quantitative analysis of polar and ionic compounds in petroleum fractions have been examined. The requirements of the analysis for sensitivity, linear dynamic range, and structural characterization have been discussed. ESI was found to be approximately two orders of magnitude more sensitive than APCI and is most suitable for the detection of analytes in weak concentrations. Equivalent relative linear dynamic ranges were observed by the two methods (at least three orders of magnitude). For the relatively high analyte concentrations examined here (e.g., 1-100 ppm or higher), the absolute area counts increased linearly with the analyte amount only in APCI, making this method more attractive for quantitative liquid chromatography/mass spectrometry (LC/MS) applications. Nevertheless, a wider range of ionic compounds can be detected by ESI than by APCI.  相似文献   