首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We developed a novel in vitro lipase assay based on the quantitation of fatty acids by liquid chromatography-mass spectrometry. Oleic acids enzymatically released from triolein substrates were isolated from the reaction mixture by reverse-phase chromatography, ionized in negative mode electrospray mass spectrometry and quantitated with the aid of [(13)C]-oleic acid internal standard. The enzymatic activity was measured by monitoring oleic acid productions at multiple time points. This method overcomes the substrate and pH limitations of conventional techniques and thus serves as a generic lipase activity assay.  相似文献   

2.
A rugged procedure utilizing reversed-phase liquid chromatography with positive-ion electrospray ionization mass spectrometry (LC-MS) along with tandem MS is described for the quantification and confirmation of N-methylpyrrolidinone (NMP) in methanolic extracts of riverine biofilm. The LC-MS method provided a 100-fold improvement in detection limits (2 ng g(-1) with a repeatability of 80-95% based on triplicate analyses) compared to a conventional LC-UV detection procedure and was applicable to quantitative analysis of biofilm samples with little or no clean up. Under low-energy collision induced dissociation (CID) conditions (17 V, laboratory frame of reference, with argon as the collision gas), two product-ions of the [M+H]+ ion were formed at m/z 69 [MH-CH3NH2]+ and m/z 58 [MH-CH3NCH]+ with relative abundances of 30% and 5%, respectively. These CID transitions were used to demonstrate that biofilm uptake of a photocatalytically-generated mixture of NMP was rapid once acclimation was achieved.  相似文献   

3.
A method has been developed which allows direct measurement of partition coefficients (log D, log P) using liquid chromatography-mass spectrometry (LC-MS). The high throughput, microtiter plate based protocol uses small quantities of 10 mM analyte in DMSO solution (5 microL) and is therefore amenable to standard archive and screening formats. Single Ion Monitoring (SIM) mass spectrometry is used to achieve optimal sensitivity. Experimental log D values for 34 known drugs have been determined, with partition coefficients ranging from -2 to 5, giving data very similar to literature values. In these analyses, deviations from known values average less than 0.3 log units. The sample handling and data processing have been significantly automated, and the protocol has been applied to over 800 in-house lead molecules to date. In its format, sensitivity, throughput, and amenability to automation, it represents significant progress in the direct measurement of partitioning behavior [1].  相似文献   

4.
An overview is given of pesticide residue determination in fruit and vegetables by liquid chromatography-mass spectrometry (LC-MS). Emphasis is placed on the thermospray, particle beam and atmospheric pressure ionization interfaces including advantages and drawbacks and typical detection limits. The capacity of each interface to provide useful data for identification/confirmation of analytes and the possibility of obtaining structural information for the identification of target and non-target compounds is discussed. Finally, sample preparation techniques are dealt with in relation to their influence on further LC-MS determination.  相似文献   

5.
The aim of this work is to established methods for determination of quinolones (ciprofloxacin, danofloxacin, enrofloxacin, difloxacin and flumequine), regulated by European Union, and sarafloxacin in turkey muscle. An experimental design has been applied for the optimization of the factors that influence the extraction of quinolones from turkey muscle in order to determine the experimental conditions for their extraction with high recoveries. Liquid chromatography with ultraviolet detection (LC-UV), liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography tandem mass spectrometry (LC-MS/MS) have been used for the simultaneous quantification of quinolones antibiotics in turkey muscle. The proposed methods have been validated according to the Food Drugs Administration guideline and presents the limit of quantification below the maximum residue limits established by the European Union for quinolones in turkey muscle. The methods developed have been applied to quantification of enrofloxacin and its main metabolite ciprofloxacin in samples of turkey muscle obtained from animals treated with enrofloxacin.  相似文献   

6.
A rapid, sensitive and specific method using liquid chromatography with tandem mass spectrometric detection (LC‐MS) was developed for the analysis of sauchinone in rat plasma. Di‐O‐methyltetrahydrofuriguaiacin B was used as internal standard (IS). Analytes were extracted from rat plasma by liquid–liquid extraction using ethyl acetate. A 2.1 mm i.d. × 150 mm, 5 µm, Agilent Zorbax SB‐C18 column was used to perform the chromatographic analysis. The mobile phase was methanol–deionized water (80:20, v/v). The chromatographic run time was 7 min per injection and the flow‐rate was 0.2 mL/min. The tandem mass spectrometric detection mode was achieved with electrospray ionization interface in positive‐ion mode (ESI+). The m/z ratios [M + Na]+, m/z 379.4 for sauchinone and m/z 395.4 for IS were recorded simultaneously. Calibration curve were linear over the range of 0.01–5 µg/mL. The lowest limit of quantification was 0.01 µg/mL. The intra‐day and inter‐day precision and accuracy of the quality control samples were 2.94–9.42% and 95.79–108.05%, respectively. The matrix effect was 64.20–67.34% and the extraction recovery was 93.28–95.98%. This method was simple and sensitive enough to be used in pharmacokinetic research for determination of sauchinone in rat plasma. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
A comparative study of the performance of liquid chromatography (LC)-atmospheric pressure chemical ionisation (APCI)-mass spectrometry (MS) and gas chromatography (GC)-mass spectrometry techniques for the determination of resin and fatty acids from paper mill process waters was carried out. These compounds are responsible for the high toxicity of paper mill effluents and little research has been carried out regarding their analysis using mass spectrometric techniques. To prove the usability of GC and LC-MS, 16 treated and untreated water samples of recycle, kraft and pulp paper mills were analysed and good agreement was observed as regards to compounds detected and corresponding concentrations. This paper also reports the limits of detection, recoveries, reproducibility, linearity and precision using the two methods. GC-MS presented better selectivity and lower detection limits (below 0.2 microg/l), but derivatization of the extracts and the short life of derivatives (12-24 h) made the technique tedious and prone to high variations. Although LC-APCI-MS presented coelution of the non-aromatic resin acids, it also showed good sensitivity (limits of detection <3 microg/l) and permitted the detection of resin and fatty acids at microg/l level. In addition, since samples could be directly injected to the chromatographic system, LC-APCI-MS was proven as a powerful technique for quick and unequivocal quality control during papermaking.  相似文献   

8.
Domestic and office dust samples (n=37) were analyzed for hexabromocyclododecanes (HBCDs) using gas chromatography-electron-capture negative ionization-mass spectrometry (GC-ECNI/MS) and liquid chromatography-electrospray tandem mass spectrometry (LC-ESI/MS/MS). To determine the best method to quantify HBCDs using GC-ECNI/MS, BDE 128 was used as internal standard (I.S.) in all samples, while 13C-labeled alpha-HBCD was used as I.S. in some samples. Total HBCD concentrations (sum of alpha-, beta-, and gamma-HBCD diastereomers) were calculated using response factors (RFs) for alpha- and gamma-HBCD as individual diastereomers and using an average RF for both diastereomers. Statistical comparison showed that concentrations obtained via GC-ECNI/MS were statistically indistinguishable (p>0.05) from those obtained using LC-ESI/MS/MS. The closest match between the two techniques was obtained using [13C]alpha-HBCD as I.S. and the average RF for alpha- and gamma-HBCDs. Excellent linear correlations (Pearson coefficient values r>0.9) were obtained between the GC-ECNI/MS and LC-ESI/MS/MS results, with slopes ranging from 0.76 to 1.36. Pentabromocyclododecenes (four isomers) and tetrabromocyclododecadienes (two isomers) were detected in the studied samples and were identified as degradation products of HBCDs after separation from the parent compound on the basis of both retention time and mass spectrum. This finding suggests that the elimination of HBr is the major degradation pathway for HBCDs in dust.  相似文献   

9.
Surface modified molecularly imprinted polymers (SM-MIPs) for 17beta-estradiol (E2), utilizing 6-ketoecradiol as a pseudo template were prepared. MIPs for E2 were synthesized using 4-vinyl pyridine and ethylene dimethacrylate as a functional monomer and cross-linking agent, respectively. MIPs selectively retained E2 and provided excellent chromatographic resolution from interfering compounds inherent in river water sample matrices. Therefore, freshly prepared MIPs were applied to quantitative mass spectrometric (negative electrospray ionization mode) detection of low levels of E2 in river water sample. In order to pre-concentrate the target compound for HPLC analysis, column switching was coupled with a pretreatment column packed with the MIPs. The repeatability of actual determinations of river water sample, in which background E2 was not detected, spiked with 50 ng/L of E2 was 2.2% RSD with a detection limit and qualification limit of 1.8 and 5.4 ng/L, respectively. Surface modification of MIP particlefs packed in the pretreatment column provided selective affinity and on-line concentration of low levels of E2 while simultaneously eliminating sample matrix interference, resulting in a significant increase in sensitivity and reproducibility for liquid chromatography-mass spectrometry analysis of E2 in river water sample.  相似文献   

10.
A new liquid chromatography-mass spectrometry (LC-MS) method has been developed and validated for the simultaneous determination of eight quinolone antibacterials for veterinary use in processed bovine milk samples. The quinolones studied included marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, sarafloxacin, difloxacin, oxolinic acid and flumequine. Also, a new sample-treatment procedure was used for extraction and preconcentration of these compounds. It involved defatting by centrifugation, protein precipitation by adding a mixture of glacial acetic acid-acetonitrile and removing acetonitrile with dichloromethane; finally, the acidified aqueous layer was evaporated to dryness in a speed vac system, resuspended in the mobile phase and filtered prior to LC injection. The mobile phase was composed of a formic acid aqueous solution 0.1% (v/v) and acetonitrile, with an initial composition of water-acetonitrile 95: 5 (v/v) and using linear gradient elution. Norfloxacin was used as internal standard. The limits of quantification found (2-7 ng g(-1)) were in all cases lower than the maximum residue limits tolerated by the European Union for these compounds in milk.  相似文献   

11.
蔬菜中阔草清等8种农药残留量的高效液相色谱-质谱分析   总被引:2,自引:0,他引:2  
建立了固相萃取-高效液相色谱-电喷雾质谱法同时测定蔬菜中的阔草清、西玛津、硫双威、绿麦隆、扑草净、仲丁威、马拉硫磷和二嗪农等8种农药的分析方法.蔬菜用乙腈超声波提取,经过ODS-C18固相萃取小柱富集纯化.采用C18柱分离,以体积分数0.03%甲酸乙腈-体积分数0.03%甲酸水溶液为流动相,线性梯度洗脱,以保留时间和质荷比对分离出的组分进行定性,用峰面积进行定量.结果表明,8种农药的质量浓度与其峰面积在一定的范围内呈良好的线性关系,检出限为0.1~5.0 μg/L,相关系数为0.9939~0.9998,样品的加标平均回收率为83%~106%,相对标准偏差为3.1%~9.8%.方法适用于蔬菜中阔草清等8种农药残留量的分析.  相似文献   

12.
利用气相色谱-质谱(GC-MS),电子轰击离子化(EI)法同时测定及确证蔬菜中多种有机磷农药和克百威的残留量。对样品的前处理方法进行了选择实验。试样用乙腈提取,将提取液过滤后,加氯化钠使水相与乙腈分离,浓缩有机相,无需净化。用GC-MS的选择离子监测(SIM)方法测定其中的敌敌畏、甲胺磷、甲拌磷、氧乐果、甲基对硫磷、克百威共6种杀虫剂的残留量并进行阳性确证。该方法的检测限量为0.0002mg/kg-0.016mg/kg,10种蔬菜6种农药的标准添加(0.01、0.02、0.1、0.2mg/kg)的回收率为72%-125%,测定相对标准偏差为6.7%-20%。本方法可以满足这6种杀虫剂的在蔬菜中的最高残留量限量的检测要求。  相似文献   

13.
Tzung-Jie Yang 《Talanta》2010,82(2):766-770
A novel method for electrically assisted microextraction coupled to liquid chromatography-mass spectrometry was evaluated for determination of trace levels of parathion in water. A pencil lead electrode was used in a di-electrode system to extract parathion onto the electrode surface with a reductive potential applied. The optimum extraction conditions were found to be a potential of −600 mV for 60 s in pH 2 phosphate buffer solution. The parathion was desorbed statically for 1 min and dynamically for 3 min in the commercial SPME-HPLC desorption chamber, then analyzed with LC-APCI-MS/MS. The detection limit (LOD) for parathion in water was found to be 0.3 ng/mL. The proposed technique was demonstrated to be fast, sensitive and not require a solvent sample pretreatment.  相似文献   

14.
State-of-the-art in liquid chromatography-mass spectrometry.   总被引:8,自引:0,他引:8  
Impressive progress has been made in the technology and application of combined liquid chromatography-mass spectrometry (LC-MS) in the past decennium. From a technique, that could only be used by a specialist, it has developed into a routinely applicable technique. LC-MS has become the method-of-choice of analytical support in many stages of drug development within pharmaceutical industries and has found its way into environmental, biochemical and other laboratories. This paper provides a perspective on the current technology, principles and applications of LC-MS.  相似文献   

15.
He H  Shi X  Chen J  Gao P  Lei Y  Xu G 《色谱》2012,30(3):245-251
口腔癌的发病率占全身恶性肿瘤的第6位,正确区分正常状态与良性和恶性口腔肿瘤,是恰当选择治疗方案的关键所在。本研究中,首先利用液相色谱-质谱和气相色谱-质谱联用方法分别得到健康人、良性口腔肿瘤患者和恶性口腔肿瘤患者血浆、尿液和唾液的代谢轮廓,然后应用正交信号校正的偏最小二乘法进行多变量统计分析。结果表明健康人、良性肿瘤患者和恶性肿瘤患者在血浆、尿液和唾液等3种体液代谢中都可以被区分开,而且找到和鉴定出19个重要差异代谢物。相关代谢通路分析显示,与健康人相比,良性和恶性口腔肿瘤患者都存在能量代谢紊乱和脂类代谢失衡的现象,但恶性口腔肿瘤患者还表现出三羧酸循环和肌醇代谢异常,这为临床诊断及治疗提供了重要信息。  相似文献   

16.
In this paper, an accurate and route method was developed to quantitative determine daidzein, genistein, glycitein, daidzin, glycitin, 6"-O-acetyldaidzin, 6"-O-acetylglycitin and 6"-O-acetylgenistin contents in selected high and low isoflavones in nutrition supplements by on line liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry (LC-APCI-MS). Improved extraction and hydrolysis methods of the isoflavones from three nutrition supplements were also studied and a rapid extraction method was developed. Comparison of different MS2 and MS3 spectra of isoflavones and some unknown compounds were also explored and proposed pathway fragments of nine isoflavones were first systematically suggested.  相似文献   

17.
There is increasing interest and demand for real multi-residue methods able to simultaneously determine pesticides with a broad spectrum of chemical characteristics in environmental and biological matrices. A method based on solid-phase extraction with a Carbograph 4 cartridge and liquid chromatography with electrospray mass spectrometry (LC-ES-MS) enabling simultaneous determination of non-acidic and acidic pesticides in real water samples is described. On repeatedly (n=5) extracting 4 l of drinking water (spike level 50 ng/l), 2 l of ground water (spike level 100 ng/l) and 1 l of river water (spike level 200 ng/l), recovery of 26 base/neutral pesticides and 13 acidic pesticides were equal to or better than 80%, except for carbendazim (67%), butocarboxim (73%), aldicarb (75%) and molinate (77%). Relative standard deviations ranged between 4 and 15%. Final extracts containing acidic and non-acidic pesticides were analyzed in a single chromatographic run while the ES-MS system was operated in both positive and negative ion modes. With the aim of finding the best operating conditions, in terms of sensitivity, the pH of the LC eluent was varied in the 2.9-8.4 range. Altogether, the best results were obtained by using an LC eluent containing 1 mmol/l formic acid. Over the entire pH range considered, well shaped peaks for both basic and acidic analytes were achieved by the use of a new generation LC column. By extracting selected ion current profiles from the total ion current mass chromatogram relative to analysis of 4 l of drinking water spiked with 50 ng/l of each of the 39 analytes, estimated limits of detection ranged between 0.05 and 1.5 ng/l, except for propyzamide (8 ng/l) and 2,4-DB (3 ng/l).  相似文献   

18.
The combination of a solid-phase extraction module, the AASP, on-line with thermospray high-performance liquid chromatography-mass spectrometry for the automated determination of drugs in plasma is described. The technique was evaluated successfully using, as an example, the determination of labetalol in human plasma. [2H7]Labetalol was used as an internal standard to compensate for changes in ionization efficiencies between analyses. The chromatographic and mass spectrometric conditions were optimized for labetalol. The combined technique was demonstrated as being robust and reliable for the analysis of plasma samples from a clinical study.  相似文献   

19.
A new liquid chromatography-mass spectrometry method for the determination of carbamazepine, clonazepam, alprazolam, estazolam and phenytoin in human plasma has been developed by using diazepam as an internal standard. Chromatographic separation was performed on a Zorbax SB-C18 column (30 mm × 2.1 mm, 3.5 μm) with a mobile phase consisting of methanol and aqueous 25 mM ammonium acetate using gradient elution. A diethyl ether extraction method was used for the extraction of five anti-epilepsy drugs. The final extract was injected for analysis by LC-MS/MS. The method was validated within the concentration range of 50–5000 ng mL?1 for five anti-epilepsy drugs. The precision of the assay (RSD%) was less than 10% at all concentration levels within the tested range. The method recoveries for all samples were more than 90%. The results indicate that the method is specific, sensitive and accurate, and suitable to study the pharmacokinetics, to adjust the dosage for individual administration, and to monitor the drug-concentration and drug abuse of the five anti-epilepsy drugs.  相似文献   

20.
Kuan-Hui Lu 《Talanta》2007,72(3):1082-1087
An integrated method of combining solid-phase microextraction (SPME) with liquid chromatography-mass spectrometry (LC-MS) was evaluated for determination trace amount of sulfonamides in meat products. Eight commonly used sulfonamides, sulfadiazine (SDZ), sulfathiazole (STZ), sulfamerazine (SMR), sulfamethazine (SMT), sulfamonomethoxine (SMMX), sulfamethoxazole (SMXZ), sulfaquinoxaline (SQX) and sulfadimethoxine (SDMX), were investigated in this study. Chromatography was performed on a C18 reversed-phase column using an isocratic acetonitrile in water as the mobile phase. Fiber coated with a 65 μm thickness of polydimethylsiloxane/divinylbenzene (PDMS/DVB) was used to extract sulfonamides at optimum conditions. Analytes were desorbed with static desorption in an SPME-HPLC desorbed chamber for 15 min and then determined by LC-MS. The detection limits of these sulfonamides in pork were from 16 μg kg−1 (SMT) to 39 μg kg−1 (SMMX). According to the analysis, the linear range was from 50 to 2000 μg kg−1 with relative standard deviation (R.S.D.s) value below 15% (intra-day) and 19% (inter-day). The proposed method was tested by analyzing meats from a local market for sulfonamides residues. Some sulfonamides in our study were detected in the meat samples. The concentration of these residual sulfonamides ranged from 66 μg kg−1 (SDZ) to 157 μg kg−1 (SQX) in a chicken sample. The results demonstrate that the SPME-LC-MS system is highly effective in analyzing trace sulfonamides in meat products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号