相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An open tomograph to image volume regions near the surface of large objects is described. The central achievement in getting such a tomograph to work is the design of a fast two-dimensional pure phase encoding imaging method to produce a cross-sectional image in the presence of highly inhomogeneous fields. The method takes advantage of the multi-echo acquisition in a Carr-Purcell-Meiboom-Gill (CPMG)-like sequence to significantly reduce the experimental time to obtain a 2D image or to spatially resolve relaxation times across the sensitive volume in a single imaging experiment. Depending on T(2) the imaging time can be reduced by a factor of up to two orders of magnitude compared to the one needed by the single-echo imaging technique. The complete echo train decay has been also used to produce T(2) contrast in the images and to spatially resolve the T(2) distribution of an inhomogeneous object, showing that variations of structural properties like the cross-link density of rubber samples can be distinguished by this method. The sequence has been implemented on a single-sided sensor equipped with an optimized magnet geometry and a suitable gradient coil system that provides two perpendicular pulsed gradient fields. The static magnetic field defines flat planes of constant frequency parallel to the surface of the scanner that can be selected by retuning the probe frequency to achieve slice selection into the object. Combining the slice selection obtained under the presence of the static gradient of the open magnet with the two perpendicular pulsed gradient fields, 3D spatial resolution is obtained.  相似文献   

2.
In this paper, we describe a method for measuring the average flow velocity of a sample by means of Nuclear Magnetic Resonance. This method is based on the Carr-Purcell-Meiboom-Gill (CPMG) sequence and does not require the application of any additional static or pulsed magnetic field gradients to the background magnetic field. The technique is based on analyzing the early-time behavior of the echo amplitudes of the CPMG sequence. Measurements of average flow velocity of water are presented. The experimental results show a linear relationship between the slope/y-intercept ratio of a linear fit of the first echoes in the CPMG sequence, and the average flow velocity of the flowing fluid. The proposed method can be implemented in low-cost Low-Field NMR spectrometers allowing a continuous monitoring of the average velocity of a fluid in almost real-time, even if the flow velocity changes rapidly.  相似文献   

3.
The probability distribution P(zeta) of diffusive and advective molecular displacements is determined using a fixed field gradient (FFG) pulse sequence, on fluid flow through a Bentheimer sandstone, in the grossly inhomogeneous stray field of a super-conducting magnet. Two decades of q-space are scanned with stimulated echoes, using the gradient of the stray field and variable encoding times delta. The strength of the gradient permits the use of short encoding times, which is desirable for limiting the distorting effects produced by flow displacements through susceptibility induced field inhomogeneities. CPMG and CP echo trains are used to refocus separately the real and imaginary parts of the stimulated echo, for experimental efficiency.  相似文献   

4.
We experimentally verify a new method of extracting the surface-to-volume ratio (S/V) of porous media with diffusion NMR. In contrast to the widely used pulsed field gradient (PFG) technique, which employs the stimulated echo coherence pathway, we use here the direct Carr-Purcell-Meiboom-Gill (CPMG) path. Even for high echoes, which exhibit ample attenuation due to diffusion in the field gradient, the relevant ruler length for the direct pathway is fixed by the diffusion length during a single inter-pulse spacing. The direct path, therefore, is well suited for probing shorter length scales than is possible with the conventional approach. In our experiments in a low-field static-gradient system, the direct CPMG pathway was found to be sensitive to structure an order of magnitude smaller than accessible with the stimulated-echo pathway.  相似文献   

5.
Carr-Purcell-Meiboom-Gill (CPMG) train of radiofrequency pulses applied to spins in the constant magnetic field gradient is an efficient variant of the modulated magnetic field gradient spin echo method, which provides information about molecular diffusion in the frequency domain instead of in the time domain as with the two-pulse gradient spin echo. The frequency range of this novel technique is broad enough to sample the power spectrum of displacement fluctuation in water-saturated pulverized silica (SiO2) and provides comprehensive information about the molecular restricted motion as well as about the structure of the medium.  相似文献   

6.
A previously published nuclear magnetic resonance (NMR) spectroscopic imaging method for mapping static magnetic fields has been modified, replacing the gradient echo sequence with an asymmetric spin echo sequence. The purpose of the modification is to reinforce the technique and make it useable even in conditions in which the gradient echo sequence cannot be operated. The modification performed was verified by an experiment performed on a low-field NMR scanner. The rough and fine errors due to the long time of measurement were corrected during the processing of the measured images. An optimization procedure was used to correct the fine errors. The map of the static magnetic field acquired using the new technique was compared to the map calculated from the phase images and both were compared to the result measured using a magnetometer. The verification confirmed the legitimacy of the modification and suitability of the novel technique. Some alternatives to the measured data processing have been suggested, shortening the global time of the measurement.  相似文献   

7.
A pulsed field gradient stimulated spin-echo NMR sequence is combined with imaging methods to spatially resolve velocity distributions and to measure 2D velocity maps ex situ. The implementation of these techniques in open sensors provides a powerful non-invasive tool to measure molecular displacement in a large number of applications inaccessible to conventional closed magnets. The method is implemented on an open tomograph that provides 3D spatial localization by combining slice selection in the presence of a uniform static magnetic field gradient along the depth direction with pulsed field gradients along the two lateral directions. Different pipe geometries are used to demonstrate that the sequence performs well even in the extremely inhomogeneous B0 and B1 fields of these sensors.  相似文献   

8.
The CPMG sequence has been extremely useful for efficient measurements of NMR signal, spin-spin relaxation, and diffusion, particularly in inhomogeneous magnetic fields, such as when samples are outside the magnet and RF coil. Due to the inaccuracy of the pulses and the off-resonance effects, the CPMG echoes have contributions from the Hahn echo as well as signals that are similar to stimulated echoes. The systematic understanding of the CPMG pulse sequence requires decomposing the magnetization dynamics into different coherence pathways. In this paper, we describe a method to classify the CPMG coherence pathways and illustrate the nature of these types of pathways. This classification shows that direct echo and stimulated echoes are the major contribution to the CPMG signal. It also provides a clear understanding of the effect of restricted diffusion in porous media.  相似文献   

9.
The anisotropic behavior of C1-C6 alkane molecules adsorbed in MFI zeolite was studied by 1H nuclear magnetic resonance (NMR) using single-pulse excitation, Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence, Hahn echo (HE) pulse sequence, and magic-angle spinning. The molecular order parameter was obtained by both static 2H NMR spectroscopy and molecular simulations. This yields an order parameter in the range of 0.28-0.42 for linear alkanes in MFI zeolite, whereas the parameter equals zero for FAU zeolite with a cubic symmetry. Thus, in the case of a zeolite with a non-cubic symmetry like MFI, the mobility of the molecules in one crystallite cannot fully average the dipolar interaction. As a consequence, transverse nuclear magnetization as revealed in the echo attenuation notably deviates from a mono-exponential decay. This information is of particular relevance for the performance of pulsed field gradient (PFG) NMR diffusion experiments, since the occurrence of non-exponential magnetization attenuation could be taken as an indication of the existence of different molecules or of molecules in different states of mobility.  相似文献   

10.
A new stimulated echo based pulsed gradient spin-echo sequence, MAG-PGSTE, has been developed for the determination of self-diffusion in magnetically inhomogeneous samples. The sequence was tested on two glass bead samples (i.e., 212-300 and <106 microm glass bead packs). The MAG-PGSTE sequence was compared to the MAGSTE (or MPFG) (P.Z. Sun, J.G. Seland, D. Cory, Background gradient suppression in pulsed gradient stimulated echo measurements, J. Magn. Reson. 161 (2003) 168-173; P.Z. Sun, S.A. Smith, J. Zhou, Analysis of the magic asymmetric gradient stimulated echo sequence with shaped gradients, J. Magn. Reson. 171 (2004) 324-329; P.Z. Sun, Improved diffusion measurement in heterogeneous systems using the magic asymmetric gradient stimulated echo (MAGSTE) technique, J. Magn. Reson. 187 (2007) 177-183; P. Galvosas, F. Stallmach, J. K?rger, Background gradient suppression in stimulated echo NMR diffusion studies using magic pulsed field gradient ratios, J. Magn. Reson. 166 (2004) 164-173, P. Galvosas, PFG NMR-Diffusionsuntersuchungen mit ultra-hohen gepulsten magnetischen Feldgradienten an mikropor?sen Materialien, Ph.D. Thesis, Universit?t Leipzig, 2003, P.Z. Sun, Nuclear Magnetic Resonance Microscopy and Diffusion, Ph.D. Thesis, Massachusetts Institute of Technology, 2003] sequence and Cotts 13-interval [R.M. Cotts, M.J.R. Hoch, T. Sun, J.T. Marker, Pulsed field gradient stimulated echo methods for improved NMR diffusion measurements in heterogeneous systems, J. Magn. Reson. 83 (1989) 252-266] sequence using both glass bead samples. The MAG-PGSTE and MAGSTE (or MPFG) sequences outperformed the Cotts 13-interval sequence in the measurement of diffusion coefficients; more interestingly, for the sample with higher background gradients (i.e., the <106 microm glass bead sample), the MAG-PGSTE sequence provided higher signal-to-noise ratios and thus better diffusion measurements than the MAGSTE and Cotts 13-interval sequences. In addition, the MAG-PGSTE sequence provided good characterization of the surface-to-volume ratio for the glass bead samples.  相似文献   

11.
范宜仁  吴飞  李虎  霍宁宁  王要森  邓少贵  杨培强 《物理学报》2015,64(9):99301-099301
面对日益复杂的勘探对象, D-T2二维核磁共振技术在实际应用中面临无法兼顾扩散系数测量范围和横向弛豫分辨率的困境. 脉冲序列作为D-T2二维核磁共振数据采集的核心技术, 其性能优劣直接影响应用效果, 在综合对比PFG, STE-PFG, BP-PFG、改良式CPMG, 扩散编程, 多回波间隔CPMG脉冲序列性能的基础上, 有效融合脉冲梯度场、恒定梯度场D-T2脉冲序列的优点, 本文提出一种基于脉冲梯度场的双变量、两窗口D-T2脉冲序列改进设计. 针对两个窗口的D-T2二维核磁共振数据反演, 为突破现有反演方法无法兼顾反演精度和解谱效率的瓶颈, 本着第二个窗口回波信号为主、第一个窗口回波信号为辅的原则, 本文提出一种同时使用两个窗口数据参与解谱的联合TSVD反演方法. 气水、油水、稠油、油气水模型不同信噪比条件下的数值模拟结果表明, 本文提供的D-T2改进脉冲序列达到了平衡扩散系数测量范围和横向弛豫分辨率的设计要求, 本文提供的联合TSVD反演方法也有效平衡了反演精度要求和解谱效率. 文中的D-T2改进脉冲序列及联合TSVD反演方法在复杂油气藏流体识别和产能预测中具有广泛的应用前景, 可为促进国内D-T2二维核磁共振岩心分析技术的发展提供有利条件.  相似文献   

12.
Diffusion in porous media has been used as a probe of pore geometry in various NMR techniques. We will examine the effect of time-dependent diffusion in CPMG by showing that the diffusion time in CPMG is approximately the echo time, even in grossly inhomogeneous magnetic fields. Extension of the diffusion time in modified CPMG sequences is discussed. Diffusion in the susceptibility-contrast induced internal field is discussed as a means to probe pore size and pore shape. Finally, we present the general concept of two-dimensional relaxation-type experiments for study of molecules, fluids, materials and their dynamics that are characterized by spin relaxation and diffusion.  相似文献   

13.
We present a simple method by which the dimensions of shear-induced multilamellar vesicles (MLVs), also known as onions, can be measured during the shearing process itself. This approach is based on the use of a closely spaced train of magnetic field gradient pulses applied during a CPMG echo sequence. The CPMG train compensates flow effects while the frequency-dependence of apparent diffusion can reveal the onion size. We present here a simple phenomenological model for restricted diffusion in multilamellar vesicles, which may be used to interpret the resulting diffusion spectrum. We demonstrate this approach with MLVs formed from the lamellar phase of sodium dodecyl sulfate (SDS) in water and octanol.  相似文献   

14.
The addition of a spin-lock preparatory sequence to a Carr-Purcell-Meiboom-Gill (CPMG) imaging sequence provides a method which allows an accurate and simple comparison of T1p and T2 contrast. Sagittal and axial brain images, produced with the application of a three pulse preparatory spin-lock sequence prior to a sixteen-echo CPMG imaging sequence, are compared with images acquired without the spin-lock sequence. The CPMG sequence uses non-selective refocusing pulses. Therefore, observed echo signals accurately reflect T2 relaxation. This allows a convenient method for assessing the degree to which T1p and T2 contrast differ. The spin-lock CPMG (SL-CPMG) images were acquired with a spin-locking field amplitude of 0.4 G and resemble heavily T2-weighted images at 0.15 T. Quantitative analyses of signal intensities from edema and normal brain tissue confirm the qualitative observations. This in vivo method should prove useful for determining when the additional RF power deposition associated with spin-locking techniques will provide an alternate form of tissue contrast than that available from additional echo collection.  相似文献   

15.
The pulsed field gradient nuclear magnetic resonance (PFG NMR) method has proved to be a powerful non-invasive technique to measure molecular displacement in various systems. It has been largely implemented with conventional NMR magnets where the volume for housing the flow setup is restricted. In this work we present the first approach to measure velocity distributions ex situ implementing a pulsed field gradient sequence on a single-sided NMR sensor. The open geometry of these sensors provides access to NMR measurements of a large number of applications previously excluded by the geometry of conventional closed magnets. Both, the distortions to the displacement encoding observed when implementing a PFG sequence in the presence of strongly inhomogeneous B0 and B1 fields, and the performance of the modifications proposed to eliminate these distortions are shown by means of numerical simulations. An alternating stimulated spin-echo PFG sequence implemented to remotely measure velocity distributions was combined with a multi-echo acquisition scheme to significantly increase the sensitivity of the method. The technique was implemented to measure the velocity propagator in a fluid undergoing laminar flow and good agreement with the theoretical result is observed.  相似文献   

16.
We have studied the temporal instability of a high field resistive Bitter magnet through nuclear magnetic resonance (NMR). This instability leads to transverse spin decoherence in repeated and accumulated NMR experiments as is normally performed during signal averaging. We demonstrate this effect via Hahn echo and Carr--Purcell--Meiboom--Gill (CPMG) transverse relaxation experiments in a 23-T resistive magnet. Quantitative analysis was found to be consistent with separate measurements of the magnetic field frequency fluctuation spectrum, as well as with independent NMR experiments performed in a magnetic field with a controlled instability. Finally, the CPMG sequence with short pulse delays is shown to be successful in recovering the intrinsic spin--spin relaxation even in the presence of magnetic field temporal instability.  相似文献   

17.
The CPMG multi-echo technique is often used to investigate the translational motion of diffusing nuclei in a confining medium. Henceforth, periodically repeated RF pulses with a diffusion-sensitizing gradient yield a formation of spin echoes of gradually decreasing amplitudes. The parameters of their exponential fits may characterize the structure of porous materials or biological tissue. In this paper, a multiexponential character of the CPMG measurements is rigorously demonstrated, once a geometrical confinement is present. Based on the multiple propagator approach, we derived a spectral representation for the echo amplitudes under external magnetic field of an arbitrary gradient profile. The multiple relaxation times and their spectral weights were found in a general form. The study of simple restrictive media allowed to obtain a quantitative condition under which the multiexponential attenuation is reduced to a monoexponential one.  相似文献   

18.
Experiments are presented, which correlate molecular displacement with the multi-exponential T2 relaxation times of water flowing and diffusing through an alginate bead pack. Three systems were studied comprising beads of 3, 1 or < mm in diameter. T2-resolved propagators were obtained through a combined pulsed gradient stimulated echo (PGSTE) and Carr-Purcell-Meiboom-Gill (CPMG) experiment. Fourier transformation with respect to q produces a propagator for each echo in the CPMG train. Inverse Laplace transformation of the CPMG decays for each point (Z) in the propagator produced a two-dimensional propagator. Analysis of these two-dimensional propagators provided insight into the transport and exchange behaviour of water flowing through this system. This experiment has been simulated in a model bead structure and the resulting T2 relaxation time behaviour and T2-resolved propagators were found to be in good agreement with the experimental data. We also present a theoretical analysis of the response to the combined PGSTE/CPMG sequence in the simple model case of Pouseille flow in a cylindrical capillary, where diffusion to a surface sink is assumed to be the dominant relaxation mechanism.  相似文献   

19.
核磁共振测井中,受激回波导致CPMG序列中前2个回波与期望值存在较大差异,严重影响仪器信噪比和储层评价效果. 为进一步改善核磁共振测井仪性能,通过探究受激回波产生机理,揭示其对CPMG回波串作用规律,提出了受激回波的校正方法. 同时针对仪器负载不同,相同发射功率产生射频场强度各异的特性,建立受激回波校正系数与射频场强的数学关系,在不同应用环境中实现对CPMG测量结果的校正. 实验表明,在信噪比较低的应用环境中,采用传统的舍去前2个回波的方法误差达24.58%,而该文设计的校正算法误差仅为4.9%.  相似文献   

20.
We present novel Carr-Purcell-like sequences using composite pulses that exhibit improved performance in strongly inhomogeneous fields. The sequences are designed to retain the intrinsic error correction of the standard Carr-Purcell-Meiboom-Gill (CPMG) sequence. This is achieved by matching the excitation pulse with the refocusing cycle such that the initial transverse magnetization lies along the axis n(Beta) characterizing the overall rotation of the refocusing cycle. Such sequences are suitable for relaxation measurements. It is shown that in sufficiently inhomogeneous fields, the echo amplitudes have an initial transient modulation that is limited to the first few echoes and then decay with the intrinsic relaxation time of the sample. We show different examples of such sequences that are constructed from simple composite pulses. Sequences of the form 90 degrees (0)-(90 degrees (90-theta/2)-theta(180-theta/2)-90 degrees (90-theta/2))(n) with theta approximately 90 degrees and 270 degrees generate signal over a bandwidth larger than that of the conventional CPMG sequence, resulting in an improved signal-to-noise ratio in inhomogeneous fields. The new sequence 127 degrees (x,y)-(127 degrees (x)-127 degrees (-x))(n) only excites signal off-resonance with a spectrum that is bimodal, peaking at Delta omega(0)=+/-omega(1). Depending on the phase and exact timing of the first pulse, symmetric or antisymmetric excitation is obtained. We also demonstrate several new sequences with improved dependence on the RF field strength. The sequence (22.5 degrees (67.5)-90 degrees (-22.5))-(90 degrees (67.5)-45 degrees (157.5)-90 degrees (67.5))(n) has the property that the phase of the signal depends on B(1), allowing coarse B(1) imaging in a one-dimensional experiment.  相似文献   