首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Simultaneous analysis of many samples under identical conditions improves the effectiveness of research and accelerates product design. A novel spectroscopic imaging approach using a multichannel detector has been developed for parallel analysis of pharmaceutical formulations under controlled environments. Samples of formulations of ibuprofen in poly(ethylene glycol) have been prepared with ibuprofen concentrations ranging from 0 to 100% using a microdroplet deposition approach. The concentration of ibuprofen in PEG at which dimerization of ibuprofen molecules can be avoided has been determined via simultaneous measurement of all samples using in situ FTIR spectroscopic imaging. FTIR spectra from all samples have been analyzed to assess the molecular state of the drug and the degree of polymer swelling as a function of drug concentration. The effect of elevated temperature on the stability of all formulations was also studied. This high-throughput approach identified the concentration range for stable formulations and provided evidence that hydrogen bonding between ibuprofen and the polymer is responsible for enhanced stability at higher temperatures. This high-throughput imaging approach, based on a miniature sampling system, significantly reduces the experimental time by allowing many (potentially a few thousand) experiments to be run in parallel and increases the accuracy by minimizing variations between experiments.  相似文献   

2.
Fourier transformed infrared (FTIR) spectroscopic imaging in combination with a novel attenuated total reflection (ATR) accessory with an expanded field of view has been applied to simultaneously obtain infrared spectra of more than 150 miniature samples, and to study the dissolution process of several different formulations in separate mini-channels simultaneously. This is the first time FTIR spectroscopic imaging using such an ATR accessory with an expanded field of view has been reported. The resultant imaging area with this approach was found to be ca. 15.4 x 21.4 mm(2) (6 x expansion). The potential of this approach includes imaging up to 440 samples simultaneously. The same accessory was used to prepare mini-channels (4 mm wide, 15 mm long and 0.5 mm deep) which were made of a PDMS grid that was self-adhered to the surface of the ATR crystal. Different molecular weights of poly(ethylene glycol) (PEG), with or without the addition of ibuprofen, have been used as model pharmaceutical formulations and chemical imaging of the simultaneous dissolution of five different formulations of PEG/ibuprofen has been demonstrated. Direct comparison between these different formulations under identical conditions was possible due to this imaging approach.  相似文献   

3.
《Vibrational Spectroscopy》2007,43(1):221-226
Fourier transform infrared (FT-IR) spectroscopic imaging in combination with a controlled humidity cell was applied to simultaneously monitor crystallisation of several binary mixtures of two drugs under identical environment. The effect of relative humidity was studied on samples of binary mixtures of nifedipine and nitrendipine with different molar ratios as well as on amorphous nitrendipine. All samples were arranged in array format on the surface of BaF2 window for simultaneous imaging using an infrared focal plane array detector. The effect of sample thickness on the analysis of imaging results was addressed using novel approach to create images. The thickness-independent images have been obtained by plotting the distribution of the wavenumber corresponding to the peak maximum of the ν(NH) vibrational mode which is sensitive to the formation of the various crystalline polymorphs. The FT-IR spectroscopic imaging approach described in this work can be utilised in further high-throughput studies of many samples under controlled environment.  相似文献   

4.
This study has demonstrated that high-throughput FTIR transmission measurements using a newly designed array-based support formed using silicon wells and a silicon wafer is a very useful and robust tool for the characterization of polymer composition for combinatorial materials research. The comonomer content in copolymers can be measured accurately with a fully automated throughput of >300 samples/day (8 h). The transmission measurement is more robust, reliable, and easier to automate than other spectroscopic methods. The support itself provides excellent resistance to aggressive organic solvents at elevated temperatures and allows the unattended deposition and preparation of polymer films for infrared analysis. Because of the excellent durability of the support with respect to the solvent, the support can be rinsed and reused many times. This high-throughput approach to infrared transmission spectroscopy can be used for measuring a wide array of polymer characteristics: vinyl content, geometrical isomers, crystallinity, and tacticity. As well, this IR approach can be used to predict the oxidative stability of the antioxidant packages. Because the support provides a means of containing hot polymer solutions while the solvent evaporates, the support is also suitable for high-throughput nanoindentation methods for the determination of modulus and other physical properties of the polymer.  相似文献   

5.
Krafft C  Salzer R  Seitz S  Ern C  Schieker M 《The Analyst》2007,132(7):647-653
Objective of this study is the novel application of Fourier transform infrared (FTIR) microscopic imaging to identify the differentiation state of individual human mesenchymal stem cells with or without osteogenic stimulation. IR spectra of several hundred single cells with lateral resolution of 5-10 microm were recorded using a FTIR imaging spectrometer coupled to a microscope with a focal plane array detector. A classification model based on linear discriminant analysis was trained to distinguish four cell types by their IR spectroscopic fingerprint. Without stimulation two cell types dominated, showing low or high levels of glycogen accumulation at the cell periphery. After stimulation, the protein composition in the cells changed and some cells started expressing calcium phosphate salts such as octacalciumphosphate, a precursor of the bone constituent hydroxyapatite. Few cells were identified which remained in their non-stimulated state. This study demonstrated for the first time that FTIR microscopic imaging can probe stem cell differentiation at the single cell level rapidly, non-destructively and with minimal preparation.  相似文献   

6.
Chan KL  Kazarian SG 《The Analyst》2006,131(1):126-131
FTIR spectroscopy is one of the most powerful methods for material characterization. However, the sensitivity of this analytical tool is often very limited especially for materials with weak infrared absorption or when spectral bands of the targeted trace material overlap with the spectral bands of major components. Fortunately, for heterogeneous samples, there is an opportunity to improve the sensitivity of detection by using an imaging approach. This paper explores the opportunity of enhancing the sensitivity of FTIR spectroscopy to detect trace amounts of materials using the FTIR imaging approach based on a focal plane array (FPA) detector. Model sample tablets of ibuprofen in hydroxypropyl methylcellulose (HPMC) have been used to exemplify the detection limits of FTIR spectroscopy using: (a) a conventional mercury cadmium telluride (MCT) detector and (b) a FPA detector. The sensitivity level was compared and it has been found that for this particular set of samples, the lowest concentration of ibuprofen in HPMC that can be detected using attenuated total reflection (ATR) measuring mode with the single element MCT detector was 0.35 wt% while using the FPA detector, the presence of drug has been detected in a sample that contains as little as 0.075 wt% of drug. The application of using this enhanced sensitivity offered by the multi-channel detector to probe trace amounts of drug particles left on the surface of a finger after handling a small amount of the drug has also been demonstrated. These results have broad implications for forensic, biomedical and pharmaceutical research.  相似文献   

7.
Fourier transform infrared (FTIR) spectroscopic imaging is a relatively new method that has received great attention as a new field of analytical chemistry. The greatest benefit of this technique lies in the high molecular sensitivity combined with a spatial resolution down to a few micrometers. Another advantage is the ability to probe samples under native conditions, which allows new insights into samples without the need for fixation, stains, or an additional marker. Advances in instrumentation have made FTIR spectroscopic imaging the tool of choice for an increasing number of applications. The main applications are in the bioanalytical chemistry of cells and tissue, polymers, and recently as well as in homeland security. This report gives a short overview of current developments and recent applications. Figure FTIR image of a polymer blend reveals the chemical composition. Online Abstract Figure (365 KB).  相似文献   

8.
We recently identified vibrational spectroscopic markers characteristic of standard glycosaminoglycan (GAG) molecules. The aims of the present work were to further this investigation to more complex biological systems and to characterize, via their spectral profiles, cell types with different capacities for GAG synthesis. After recording spectral information from individual GAG standards (hyaluronic acid, chondroitin sulfate, dermatan sulfate, heparan sulfate) and GAG-GAG mixtures, GAG-defective mutant Chinese hamster ovary (CHO)-745 cells, wild-type CHO cells, and chondrocytes were analyzed as suspensions by high-throughput infrared spectroscopy and as single isolated cells by infrared imaging. Spectral data were processed and interpreted by exploratory unsupervised chemometric methods based on hierarchical cluster analysis and principal component analysis. Our results showed that the spectral information obtained was discriminant enough to clearly delineate between the different cell types both at the cell suspension and single-cell levels. The abilities of the technique are to perform spectral profiling and to identify single cells with different potentials to synthesize GAGs. Infrared microspectroscopy/imaging could therefore be developed for cell screening purposes and further for identifying GAG molecules in normal tissues during physiological conditions (aging, healing process) and numerous pathological states (arthritis, cancer). Figure
FTIR imaging for profiling GAG-synthesizing cells  相似文献   

9.
Selection of personalized chemotherapy regimen for individual patients has significant potential to improve chemotherapy efficacy and to reduce the deleterious effects of ineffective chemotherapy drugs. In this study, a rapid and high-throughput in vitro drug response assay was developed using a combination of microwell array and molecular imaging. The microwell array provided high-throughput analysis of drug response, which was quantified based on the reduction in intracellular uptake (2-[N-(7-nitrobenz-2-oxa-1,3-diazol-4-yl)amino]-2-deoxy-d-glucose) (2-NBDG). Using this synergistic approach, the drug response measurement was completed within 4 h, and only a couple thousand cells were needed for quantification. The broader application of this microwell molecular imaging approach was demonstrated by evaluating the drug response of two cancer cell lines, cervical (HeLa) and bladder (5637) cancer cells, to two distinct classes of chemotherapy drugs (cisplatin and paclitaxel). This approach did not require an extended cell culturing period, and the quantification of cellular drug response was 4–16 times faster compared with other cell-microarray drug response studies. Moreover, this molecular imaging approach had comparable sensitivity to traditional cell viability assays, i.e., the MTT assay and propidium iodide labeling of cellular nuclei;and similar throughput results as flow cytometry using only 1,000–2,000 cells. Given the simplicity and robustness of this microwell molecular imaging approach, it is anticipated that the assay can be adapted to quantify drug responses in a wide range of cancer cells and drugs and translated to clinical settings for a rapid in vitro drug response using clinically isolated samples.   相似文献   

10.
The molecular composition of mycobacteria and Gram-negative bacteria cell walls is structurally different. In this work, Raman microspectroscopy was applied to discriminate mycobacteria and Gram-negative bacteria by assessing specific characteristic spectral features. Analysis of Raman spectra indicated that mycobacteria and Gram-negative bacteria exhibit different spectral patterns under our experimental conditions due to their different biochemical components. Fourier transform infrared (FTIR) spectroscopy, as a supplementary vibrational spectroscopy, was also applied to analyze the biochemical composition of the representative bacterial strains. As for co-cultured bacterial mixtures, the distribution of individual cell types was obtained by quantitative analysis of Raman and FTIR spectral images and the spectral contribution from each cell type was distinguished by direct classical least squares analysis. Coupled atomic force microscopy (AFM) and Raman microspectroscopy realized simultaneous measurements of topography and spectral images for the same sampled surface. This work demonstrated the feasibility of utilizing a combined Raman microspectroscopy, FTIR, and AFM techniques to effectively characterize spectroscopic fingerprints from bacterial Gram types and mixtures.
Figure
AFM deflection images, Raman spectra, SEM images, and FTIR of Mycobacterium sp. KMS  相似文献   

11.
This paper reports use of a combination of Fourier-transform infrared (FTIR) spectroscopic imaging and desorption electrospray ionization linear ion-trap mass spectrometry (DESI MS) for characterization of counterfeit pharmaceutical tablets. The counterfeit artesunate antimalarial tablets were analyzed by both techniques. The results obtained revealed the ability of FTIR imaging in non-destructive micro-attenuated total reflection (ATR) mode to detect the distribution of all components in the tablet, the identities of which were confirmed by DESI MS. Chemical images of the tablets were obtained with high spatial resolution. The FTIR spectroscopic imaging method affords inherent chemical specificity with rapid acquisition of data. DESI MS enables high-sensitivity detection of trace organic compounds. Combination of these two orthogonal surface-characterization methods has great potential for detection and analysis of counterfeit tablets in the open air and without sample preparation.  相似文献   

12.
Infrared microspectroscopy is an emerging approach for disease analysis owing to its capability for in situ chemical characterization of pathological processes. Synchrotron-based infrared microspectroscopy (SR-IMS) provides ultra-high spatial resolution for profiling biochemical events associated with disease progression. Spectral alterations were observed in cultured oral cells derived from healthy, precancerous, primary, and metastatic cancers. An innovative wax-physisorption-based kinetic FTIR imaging method for the detection of oral precancer and cancer was demonstrated successfully. The approach is based on determining the residual amount of paraffin wax (C25H52) or beeswax (C46H92O2) on a sample surface after xylene washing. This amount is used as a signpost of the degree of physisorption that altered during malignant transformation. The results of linear discriminant analysis (LDA) of oral cell lines indicated that the methylene (CH2) and methyl group (CH3) stretching vibrations in the range of 3,000–2,800 cm?1 have the highest accuracy rate (89.6 %) to discriminate the healthy keratinocytes (NHOK) from cancer cells. The results of wax-physisorption-based FTIR imaging showed a stronger physisorption with beeswax in oral precancerous and cancer cells as compared with that of NHOK, which showed a strong capability with paraffin wax. The infrared kinetic study of oral cavity tissue showed a consistency in the wax physisorption of the cell lines. On the basis of our findings, these results show the potential use of wax-physisorption-based kinetic FTIR imaging for the early screening of oral cancer lesions and the chemical changes during oral carcinogenesis.
Figure
Synchrotron-based infrared microspectroscopy (SR-IMS) provides ultra-high spatial resolution for profiling biochemical events associated with disease progression. FTIR spectra collected by SR-IMS were classified by linear discriminant analysis (LDA). The results of LDA of oral cell lines indicate the optical absorption in the range of 3,000–2,800 cm?1 have the highest accuracy to discriminate normal healthy oral keratinocytes (NHOK) from cancer cells. Two types of organic waxes with different polarity were used as adsorbents for cancer screening. The results of wax-physisorption-based FTIR imaging showed a stronger physisorption of beeswax in tumor tissues as compared with that of normal oral mucosa, which showed a stronger capability of physisorption to paraffin wax.  相似文献   

13.
Bilirubin (BR) aggregating at liquid/liquid interface was firstly detected by Fourier transform infrared (FTIR) imaging/spectroscopy combining with ultraviolet-visible (UV/Vis) absorption spectra. In the UV/Vis absorption spectra of BR aggregate, a new shoulder appeared at 474 nm, and BR absorption maximum underwent red shift from 450 nm to a longer wavelength at 497 nm, which indicates that BR aggregate was formed at the interface. Meanwhile, the BR molecule structure changed or conformation torsion, that is, the increase in orbit overlap or dihedral angle and the enhancement of exciton coupling. In the study of FTIR imaging/spectroscopy, the hydrogen bond-sensitive infrared bands of BR aggregate showed remarkable changes in band shift and intensity compared with those of BR powder, suggesting that the intramolecular hydrogen bonds broke out and internal structure changed. These new findings will be helpful for understanding of the BR molecular interaction, transportation, complex with serum albumin and metal ions, and the effect of BR aggregating on biomembrane and human tissues.
Figure
Schematic representation of the FTIR spectroscopic imaging for interfacial BR aggregation  相似文献   

14.
Combinatorial screening of materials formulations followed by the scale-up of combinatorial leads has been applied for the development of high-performance coating materials for automotive applications. We replaced labor-intensive coating formulation, testing, and measurement with a "combinatorial factory" that includes robotic formulation of coatings, their deposition as 48 coatings on a 9x12-cm plastic substrate, accelerated performance testing, and automated spectroscopic and image analysis of resulting performance. This high-throughput (HT) performance testing and measurement of the resulting properties provided a powerful set of tools for the 10-fold accelerated discovery of these coating materials. Performance of coatings is evaluated with respect to their weathering, because this parameter is one of the primary considerations in end-use automotive applications. Our HT screening strategy provides previously unavailable capabilities of (1) high speed and reproducibility of testing by using robotic automation and (2) improved quantification by using optical spectroscopic analysis of discoloration of coating-substrate structure and automatic imaging of the integrity loss of coatings. Upon testing, the coatings undergo changes that are impossible to quantitatively predict using existing knowledge. Using our HT methodology, we have developed several cost-competitive coatings leads that match the performance of more costly coatings. These HT screening results for the best coating compositions have been validated on the traditional scales of coating formulation and weathering testing. These validation results have confirmed the improved weathering performance of combinatorially developed coatings over conventional coatings on the traditional scale.  相似文献   

15.
This paper reports the first design and fabrication of a 64 multielectrode array for high-throughput impedance spectroscopy. The purpose of this work is the development of a measurement system for the discovery and improvement of sensor materials using combinatorial methods. An array of interdigital capacitors (IDC) screen-printed onto a high-temperature-resistant Al(2)O(3) substrate is determined to be the optimal test plate. The electrode layout, and therefore also the idle capacity, is determined by specific requirements. Calculation of the idle capacity of the IDC as a function of the electrode width and distance allows adjustment and thus optimization of the array. Parasitic effects caused by the leads and contacts are compensated by a software-aided calibration. Apart from the use of the substrates for discovery of new sensor materials, the presented electrode array is also suitable for electrocatalytic applications as well as impedance spectroscopic studies of semiconductors and dielectrics.  相似文献   

16.
Raman and infrared spectroscopy have been recognized to be promising tools in clinical diagnostics because they provide molecular contrast without external stains. Here, vertex component analysis (VCA) was applied to Raman and Fourier transform infrared (FTIR) images of liver tissue sections and the results were compared with K-means cluster analysis, fuzzy C-means cluster analysis and principal component analysis. The main components of VCA from three Raman images were assigned to the central vein, periportal vein, cell nuclei, liver parenchyma and bile duct. After resonant Mie scattering correction, VCA of FTIR images identified veins, liver parenchyma, cracks, but no cell nuclei. The advantages of VCA in the context of tissue characterization by vibrational spectroscopic imaging are that the tissue architecture is visualized and the spectral information is reconstructed. Composite images were constructed that revealed a high molecular contrast and that can be interpreted in a similar way like hematoxylin and eosin stained tissue sections.  相似文献   

17.
Tan F  Feng X  Li M  Wang Z  Yang L  Li Y  Feng Y  Nie F 《Analytica chimica acta》2008,629(1-2):38-46
This article aims at designing a wavelet alternative to Fourier transform infrared spectra (FTIR). In order to select the most suitable wavelet parameters to perform, several decomposition levels and 53 wavelets were tested by trial and error approach, respectively. The result indicated that discrete meyer wavelet (dmey) associated with its third decomposition level was very efficient for this purpose. On the base of it, a novel library named as Fourier transform infrared wavelet coefficients library (FTIR-WC) has been constructed. Finally, two tools such as library search and structure elucidation were developed to evaluate the capability of the new library system. The results obtained were also compared with those from FTIR library by a variety of indices. The results suggested that the new library performed better but with less volume. This work is expected to propose a novel and practical strategy in infrared spectroscopic analysis.  相似文献   

18.
Contaminated meat and bone meal (MBM) in animal feedstuff has been the source of bovine spongiform encephalopathy (BSE) disease in cattle, leading to a ban in its use, so methods for its detection are essential. In this study, five pure feed and five pure MBM samples were used to prepare two sets of sample arrangements: set A for investigating the discrimination of individual feed/MBM particles and set B for larger numbers of overlapping particles. The two sets were used to test a Markov random field (MRF)-based approach. A Fourier transform infrared (FT-IR) imaging system was used for data acquisition. The spatial resolution of the near-infrared (NIR) spectroscopic image was 25 μm?×?25 μm. Each spectrum was the average of 16 scans across the wavenumber range 7,000-4,000 cm?1, at intervals of 8 cm?1. This study introduces an innovative approach to analyzing NIR spectroscopic images: an MRF-based approach has been developed using the iterated conditional mode (ICM) algorithm, integrating initial labeling-derived results from support vector machine discriminant analysis (SVMDA) and observation data derived from the results of principal component analysis (PCA). The results showed that MBM covered by feed could be successfully recognized with an overall accuracy of 86.59 % and a Kappa coefficient of 0.68. Compared with conventional methods, the MRF-based approach is capable of extracting spectral information combined with spatial information from NIR spectroscopic images. This new approach enhances the identification of MBM using NIR spectroscopic imaging.
Figure
?  相似文献   

19.
In the present study, Fourier transform infrared (FTIR) imaging and data analysis methods were combined to study morphological and molecular patterns of St. John's wort (Hypericum perforatum) in detail. For interpretation, FTIR imaging results were correlated with histological information gained from light microscopy (LM). Additionally, we tested several evaluation processes and optimized the methodology for use of complex FTIR microscopic images to monitor molecular patterns. It is demonstrated that the combination of the used spectroscopic method with LM enables a more distinct picture, concerning morphology and distribution of active ingredients, to be gained. We were able to obtain high-quality FTIR microscopic imaging results and to distinguish different tissue types with their chemical ingredients.  相似文献   

20.
El Khoury Y  Hellwig P 《Chemphyschem》2011,12(14):2669-2674
Herein, we present the development of a far-infrared spectroscopic approach for studying metalloenzyme active sites in a redox-dependent manner. An electrochemical cell with 5 mm path and based on silicon windows was found to be appropriate for the measurement of aqueous solutions down to 200 cm(-1) . The cell was probed with the infrared redox signature of the metal-ligand vibrations of different iron-sulfur proteins. Each Fe-S cluster type was found to show a specific spectral signature. As a common feature, a downshift of the frequency of the Fe-S vibrations was seen upon reduction, in line with the increase of the Fe-S bond. This downshift was found to be fully reversible. Electrochemically induced FTIR difference spectroscopy in the far infrared is now possible, opening new perspectives on the understanding of metalloproteins in function of the redox state.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号