首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Representative compounds with a 1,3‐dihydroxybenzene substructure belonging to different important polyphenol classes (stilbenes, flavones, isoflavones, flavonols, flavanones, flavanols, phloroglucinols, anthraquinones and bisanthraquinones) were investigated based on detailed high‐resolution tandem mass spectrometry measurements with an Orbitrap system under negative ion electrospray conditions. The mass spectral behaviour of these compound classes was compared among each other not only with respect to previously described losses of CO, CH2CO and C3O2 but also concerning the loss of CO2 and successive specific fragmentations. Furthermore, some unusual fragmentations such as the loss of a methyl radical during mass spectral decomposition are discussed. The obtained results demonstrate both similarities and differences in their mass spectral fragmentation under MSn conditions, allowing a characterization of the corresponding compound type. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
Liquid chromatography negative ion electrospray ionisation tandem mass spectrometry has been used for characterisation of naturally occurring prenylated fungal metabolites and synthetic derivatives. The fragmentation studies allow an elucidation of the decomposition pathways for these compounds. It could be shown, that the prenyl side chain is degraded by successive radical losses of C5 units. Both the benzoquinones and the phenolic derivatives display significant key ions comprising the aromatic ring. In some cases, the formation of significant oxygen-free key ions could be evidenced by high-resolution MS/MS measurements. Furthermore, the different types of basic skeletons, benzoquinones and phenol type as well as cyclic prenylated compounds, can be differentiated by their MS/MS behaviour.
Figure
Fruiting bodies of Suillus bovinus, the structure of boviquinone-4 and its negative ion MS2 spectrum  相似文献   

3.
Oxidized deoxynucleosides are widely used as biomarkers for DNA oxidation and oxidative stress assessment. Although gas chromatography mass spectrometry is widely used for the measurement of multiple DNA lesions, this approach requires complex sample preparation contributing to possible artifactual oxidation. To address these issues, a high performance liquid chromatography (HPLC)-tandem mass spectrometric (LC-MS/MS) method was developed to measure 8-hydroxy-2'-deoxyguanosine (8-OH-dG), 8-hydroxy-2'-deoxyadenosine (8-OH-dA), 2-hydroxy-2'-deoxyadenosine (2-OH-dA), thymidine glycol (TG), and 5-hydroxy-methyl-2'-deoxyuridine (HMDU) in DNA samples with fast sample preparation. In order to selectively monitor the product ions of these precursors with optimum sensitivity for use during quantitative LC-MS/MS analysis, unique and abundant fragment ions had to be identified during MS/MS with collision-induced dissociation (CID). Positive and negative ion electrospray tandem mass spectra with CID were compared for the analysis of these five oxidized deoxynucleosides. The most abundant fragment ions were usually formed by cleavage of the glycosidic bond in both positive and negative ion modes. However, in the negative ion electrospray tandem mass spectra of 8-OH-dG, 2-OH-dA, and 8-OH-dA, cleavage of two bonds within the sugar ring produced abundant S1 type ions with loss of a neutral molecule weighing 90 u, [M - H - 90]-. The signal-to-noise ratio was similar for negative and positive ion electrospray MS/MS except in the case of thymidine glycol where the signal-to-noise was 100 times greater in negative ionization mode. Therefore, negative ion electrospray tandem mass spectrometry with CID would be preferred to positive ion mode for the analysis of sets of oxidized deoxynucleosides that include thymidine glycol. Investigation of the fragmentation pathways indicated some new general rules for the fragmentation of negatively charged oxidized nucleosides. When purine nucleosides contain a hydroxyl group in the C8 position, an S1 type product ion will dominate the product ions due to a six-membered ring hydrogen transfer process. Finally, a new type of fragment ion formed by elimination of a neutral molecule weighing 48 (CO2H4) from the sugar moiety was observed for all three oxidized purine nucleosides.  相似文献   

4.
The direct analysis of thiophene-containing compounds present in the leaf secretory cavities of Tagetes (Asteraceae) was obtained by tandem mass spectrometry (MS—MS). In contrast to the usual extraction and chromatographic procedures, leaf glands were pricked with a column injection syringe and the sample was collected directly in a glass capillary. Direct electron impact mass spectrometric analysis of such secretions led to the identification of sulphur containing ionic species, as determined by both isotopic cluster analysis and accurate mass measurements. The molecular ions were easily identifies by parent ion scans and their further structural characterization was achieved by MS—MS.  相似文献   

5.
A method is described for identifying serine phosphorylation sites in proteins, based on conventional (32)P labeling followed by electrophoretic separation, 'in-gel' digestion with a protease, peptide extraction, reversed-phase high-performance liquid chromatographic separation and collection and off-line analysis of the radioactive fractions by nanospray ion trap mass spectrometry. The method was successfully applied to the identification of three phosphorylation sites in two proteins which were subjected to in vitro phosphorylation under physiological conditions. Different combinations of the various scanning modes of the ion trap, including high-resolution, multiple subfragmentation (or MS(n)) and fast scan analysis, were employed to identify the phosphopeptides, determine their sequence and localize the exact site of phosphorylation. 'Blind' fragmentation using fast scans was used to analyze a phosphopeptide which was undetectable in other scanning modes. The sequence, phosphorylation site and double cysteine modification of the potassium adduct of a peptide containing 35 residues were also determined by multiple fragmentation. The results not only support the validity of the proposed method for routine identification of phosphorylation sites, but also demonstrate the exceptional capability of off-line ion trap mass spectrometry in combination with nanospray ionization for performing very detailed studies on the structure of peptides.  相似文献   

6.
Twenty proteinogenic amino acids (AAs) were determined without derivatization using flow injection analysis followed by electrospray ionization mass spectrometry and tandem mass spectrometry (ESI-MS and ESI-MS/MS) and electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry (ESI-FAIMS-MS and ESI-FAIMS-MS/MS), in positive and negative ionization modes. Three separate sets of ESI-FAIMS conditions were used for the separation and detection of the 20 AAs. Typically ESI-FAIMS-MS showed somewhat improved sensitivity and significantly better signal-to-noise ratios than ESI-MS mainly due to the elimination of background noise. However, the difference between ESI-FAIMS-MS and ESI-MS/MS was significantly less. ESI-FAIMS was able to partially or completely resolve all the isobaric amino acid overlaps such as leucine, isoleucine and hydroxyproline or lysine and glutamine. Detection limits for the amino acids in ESI-FAIMS-MS mode ranged from 2 ng/mL for proline to 200 ng/mL for aspartic acid. Overall, ESI-FAIMS-MS is the preferred method for the quantitative analysis of AAs in a hydrolyzed yeast matrix.  相似文献   

7.
Carbamate-linked Oligodeoxynucleosides, in which the backbone consists of carbamate and N-methylcarbamate linkages, have been analyzed by negative ion liquid secondary ion mass spectrometry. Bidirectional sequence-determining fragmentations are postulated to occur from a common radical anion intermediate that is produced by capture of an ionizing electron by the neutral sample molecule. Fragmentation reactions appear to be related to whether a proton or methyl group is present on the amide nitrogen.  相似文献   

8.
This paper reports the first comparative study of the gas-phase fragmentation chemistry of monensin in negative ion mode electrospray and nanoelectrospray tandem mass spectrometry. The fragmentation was observed to occur at lower energies in nanoelectrospray than electrospray. The major product ions are proposed to be formed via an initial neutral elimination of methanol followed be subsequent fragmentation. The low-mass product ions were observed at the same m/z for both monensin A and B.  相似文献   

9.
The analysis of 1-hexadecyl-2-acetyl-glycerophosphocholine (platelet activating factor, PAF) by negative ion and normal-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) was investigated as an alternative technique to the currently used gas chromatography/MS and positive ion LC/MS/MS procedures. The positive ion [M + H]+ derived from PAF and generated by electrospray ionization is abundant, but the potential presence of isobaric 1-octadecanoyl-2-lyso-glycerophosphocholine (stearoyl-lyso-GPC) and 1-hexadecanoyl-2-formyl-glycerophosphocholine (PFPC) in biological samples limits the use of the most abundant collision-induced decomposition (CID) transition (formation of the phosphocholine ion, m/z 524-->184) if chromatographic separation is not achieved. Less abundant CID product ions, such as loss of the neutral ketene molecule derived from the respective fatty acyl groups, provide the requisite specificity, but the intensity of these transitions yields a signal-to-noise ratio that greatly diminishes the analytical sensitivity. With negative ion LC/MS/MS, however, the molecular anions [M - 15]- derived from PAF, stearoyl-lyso-GPC and PFPC decompose to the carboxylate anions at m/z 59, 283 and 255, respectively, permitting discrimination of these isobaric molecules even without chromatographic separation. In addition, the CID of [M - 15]- was favorable, yielding ion currents of sufficient intensity to permit the measurement of PAF when isolated from small quantities of biological material. With the use of a stable isotopically labeled variant of PAF and isotope dilution, negative ion LC/MS/MS was found to measure PAF reliably even in the presence of the isobaric stearoyl-lyso-GPC and permitted the use of non-chlorinated mobile phases for normal-phase high-performance LC.  相似文献   

10.
Mass-selected reagent ion chemical ionization (CI) performed in an ion trap instrument is an efficient tool to investigate gas-phase ion reactivities and therefore to find out new and/or optimized applications for structural analysis. For instance, it was shown that the C3H6O+ . (58 mass units) molecular ion originated from vinyl methyl ether (VME) should necessarily be used alone (i.e. unit-mass selected) to produce significant diagnostic-ions for double bond location in aliphatic alkenes. Regarding the assignment of epoxides, the previous NO+/CI method was adapted for an optimal use in the trap through isolation of NO+ cation from N2O (instead of NO) plasma and production of the acylium diagnostic-ions via CID of [M − H]+ formed by NO+-induced hydride abstraction. New alkylation ion-products, e.g. RCH = O+-al , were also found to characterize isomeric epoxides as a result of either an initial electrophilic addition of the C2H5+ cation (with saturated epoxides) or a methyl-transfer from [VME]+ . (with α,β-unsaturated epoxides). The multiple tandem mass spectrometry (MSn) capabilities of the ion trap were essential to achieve reagent ion mass-selection, structural assignment of the diagnostic-ions, or to provide further selectivity. © 1997 John Wiley & Sons, Ltd.  相似文献   

11.
The ion trap mass spectrometer is a tandem-in-time instrument that has promise as an extremely sensitive device for practical tandem mass spectrometry assays. An approach for the quantitative analysis of unknown drug levels in crude extracts, using combined capillary gas chromatography and the ion trap mass spectrometer in the tandem mode, is described. One-gram plasma samples were spiked with an anti-inflammatory drug at levels of 1–100 ng, and with 50 ng of a chemical analog internal standard. Crude extracts of the plasma samples are analyzed by using scan functions that utilize combined radiofrequency (rf) and de voltages. The need for combined rf- and de-voltage sequences for analysis of such extracts is demonstrated by comparison to attempted analyses using only rf voltages. Limitations of the method are: (1) the need for accurate calibration of ionization times to obtain linear calibration lines, and (2) the lack of automatic gain control for scans using combined rf and dc voltages to control and optimize parent ion populations and to allow a simpler analysis of “unknowns. ”  相似文献   

12.
A method for the quantatitive determination of pethidine in human urine by liquid secondary ion and tandem mass spectrometry is presented. Quantification was carried out by using ketamine as internal standard. It was found that the collision-induced dissociation (CID) spectrum of the [M + H]+ ion of pethidine exhibited a prominent daughter ion at m/z 220 and ketamine also yielded the same daughter ion at m/z 220. For ((quadrupole)) quantitative analysis, the first quadrupole mass filter was set to transmit m/z 220 and a narrow-range magnet scan yielded a spectrum of parents, including m/z 238 and 248, correspending to ketamine and pethidine, respectively.  相似文献   

13.
14.
More sensitive detection of prions in brain is important because it would allow early detection of disease in young animals and assure a safer food supply. We have quantitated the amount of proteinase K-resistant prion protein (PrP 27-30) by use of nano-scale liquid chromatography coupled to tandem mass spectrometry using the multiple reaction monitoring mode of operation. We used a method based on the detection of VVEQMCTTQYQK (residues 209-220) obtained by reduction, alkylation and digestion with trypsin. Quantitation of the amount of PrP 27-30 in the brains of Syrian hamsters was possible as early as 24 h after inoculation. Our results show sensitive detection of 180 fmol of PrP 27-30 per g brain (wet weight) as early as 24 h after inoculation. Clinical symptoms are not observed until 9 weeks after inoculation.  相似文献   

15.
A simple liquid chromatographic method combined with tandem mass spectrometry (LC-MS-MS) is described for the analysis of aminoglycoside antibiotics. Clinically these antibiotics may cause both ototoxicity and nephrotoxicity; therefore, the monitoring of aminoglycoside levels in patient plasma is required for protecting human health. In this study separation of the method is based on ion-pair chromatographic technology on a short capillary reversed-phase C18 column. The method was successfully applied to analyze amikacin in human plasma. In human plasma after deproteinisation with HFBA, an aliquot of 1 microL supernatant was injected into the chromatographic system. Only a small amount of plasma sample, 10 microL, is sufficient for the monitoring of amikacin levels in clinically therapeutic range. The relative standard deviations (RSD) of the method for intra- and inter-day analyses (n=5) are less than 5.8%. Application of this method for the trace analysis of amikacin in human plasma proved simple and workable.  相似文献   

16.
The mass spectral fragmentation of echinacoside, a pharmacologically active caffeoyl-glycoside isolated from Echinacea angustifolia roots, has been investigated using different soft-ionization techniques, field desorption and fast atom bombardment (positive and negative ions) mass Spectrometry. Both ionization modes are successful in molecular mass determination and furnish approximately equivalent structural information. A fast atom bombardment tandem mass spectrometry approach (negative ions) was developed for the study of the fragmentation pathways and for the detection of echinacoside in crude plant extracts. The results demonstrate the usefulness of this technique for the rapid search of this important caffeoyl-glucoside directly in natural complex matrices.  相似文献   

17.
The effects of metal cationization on collisionally activated dissociation (CAD) of phospholipids were investigated by electrospray ionization with quadrupole ion trap tandem mass spectrometry. The metal ions include Li(+), Na(+), K(+), Sr(2+), Ba(2+), and the first transition series. CAD of the transition metal ion-bound lipid complexes gave significant yields of product ions that identify the positions of the two fatty acyl substituents on the glycerophospholipid backbone. The cobalt(II) ion, which has a single naturally occurring isotope, was expected to be a better cationization reagent as it produces simpler mass spectra than other transition metal ions. CAD of the cobalt(II) ion complexes of glycerophosphoethanolamines, glycerophosphoglycerols and glycerophosphoserines yielded product ions that revealed information regarding both the lipid classes and the regiospecific positions of the two fatty acyl substituents.  相似文献   

18.
Two heptapeptides have been prepared by Fmoc methodology using Wang resin as solid support. For attachment of the first amino acid, several coupling systems were evaluated, and DIC/DMAP system could give yields of >99% and low levels of racemization. The selection of scavenger combination to deprotect side chains revealed that H2O/p-cresol was good at scavenging trityl and 1,2-ethanedithiol was highly efficient for scavenging t-butyl. Through shortening the preactivation time to 5 min, the racemization which occurred during formation of amide bonds coupled by HBTU was minimized. The crude peptides were characterized by RP-HPLC and MS, and sequenced by MS/MS to acquire reliable amino acid sequence information.  相似文献   

19.
Electrospray ionization mass spectrometry of neat ionic liquids does not require continuous sample injection and the presence of a molecular solvent facilitates analysis of the ionic liquid itself and dissolved analytes.  相似文献   

20.
This paper reports a rapid and sensitive method for determination of the anti-inflammatory compound vicenin-2 in L. ericoides Mart. using liquid chromatography-tandem mass spectrometry. Separation of the compound of interest was performed on a VP-ODS(18) (150 x 2 mm, Shimadzu, Japan) column and a pre-column packed with GPV-ODS C(18) (5 x 2 mm, Sigma-Aldrich, USA) with acetonitrile-water (15:85) mobile phase containing 2% acetic acid using isocratic flow at 0.5 mL/min for 2 min. Multiple-reaction monitoring of vicenin-2 was performed using electrospray positive ionization. The linear calibration curves were generated using a concentration range of 5-2500 ng/mL with correlation coefficients >0.99. The values of limit of detection and limit of quantitation were found to be 1 and 5 ng/mL, respectively. The method developed based on LC-ESIMS/MS is advantageous because it permits the rapid and selective detection of vicenin-2. Furthermore, the method can be easily applied to the routine analysis of vicenin-2 in plant extracts using a minimal amount of sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号