首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 895 毫秒
1.
Simple, rapid, and selective RP-HPLC methods with UV detection were developed for simultaneous determination of chlordiazepoxide hydrochloride and mebeverine hydrochloride (Mixture I) and carvedilol and hydrochlorothiazide (Mixture II). The chromatographic separation in both mixtures was achieved by using an RP-C8 (octylsilyl) analytical column. For Mixture I, a mobile phase composed of acetonitrile-0.05 M disodium hydrogen phosphate-triethylamine (50 + 50 + 0.2, v/v/v), pH 2.5, was used; the detector wavelength was 247 nm. For Mixture II, the mobile phase consisted of acetonitrile-0.05 M disodium hydrogen phosphate (50 + 50, v/v), pH 4.0, and the detector was set at 220 nm. Quantification of the analytes was based on measuring their peak areas. Both mixtures were resolved in less than 6 min. The reliability and analytical performance of the proposed HPLC procedures were statistically validated with respect to linearity, range, precision, accuracy, selectivity, robustness, LOD, and LOQ. The linear dynamic ranges were 2.5-150 and 2.5-500 microg/mL for chlordiazepoxide HCI and mebeverine HCI, respectively, and 0.25-200 and 0.25-150 microg/mL for carvedilol and hydrochlorothiazide, respectively. The validated HPLC methods were successfully applied to the analysis of their commercial tablet dosage forms, for which no interfering peaks were encountered from common pharmaceutical adjuvants.  相似文献   

2.
3.
A fast and reliable method for the determination of repaglinide is highly desirable to support formulation screening and quality control. A first-derivative UV spectroscopic method was developed for the determination of repaglinide in tablet dosage form and for dissolution testing. First-derivative UV absorbance was measured at 253 nm. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ) in comparison to the U.S. Pharmacopeia (USP) column high-performance liquid chromatographic (HPLC) method. The first-derivative UV spectrophotometric method showed excellent linearity [correlation coefficient (r) = 0.9999] in the concentration range of 1-35 microg/mL and precision (relative standard deviation < 1.5%). The LOD and LOQ were 0.23 and 0.72 microg/mL, respectively, and good recoveries were achieved (98-101.8%). Statistical comparison of results of the first-derivative UV spectrophotometric and the USP HPLC methods using the t-test showed that there was no significant difference between the 2 methods. Additionally, the method was successfully used for the dissolution test of repaglinide and was found to be reliable, simple, fast, and inexpensive.  相似文献   

4.
A new, simple column reversed-phase high-performance liquid chromatographic (HPLC) method for simultaneous determination of rabeprazole sodium (RAB) and domperidone (DOM) in a combined tablet dosage form has been developed and validated. Determination was performed using a Jasco HPLC system with a HiQ SiL octadecylsilane (C18) column (250 x 4.6 mm id), acetonitrile-0.1 M ammonium acetate (50 + 50, v/v) mobile phase, and paracetamol as an internal standard. The detection was performed using a UV detector set at 280 nm. The method was validated with respect to linearity, accuracy, precision, and robustness. Beer's law was obeyed in the concentration range of 1.0-10.0 and 0.5-5.0 microg/mL for RAB and DOM, respectively. The method has been successfully applied for the analysis of drugs in a pharmaceutical formulation.  相似文献   

5.
This paper describes validated high-performance column liquid chromatographic (HPLC) and high-performance thin-layer chromatographic (HPTLC) methods for simultaneous estimation of acetylsalicylic acid (ASA) and clopidogrel bisulfate (CLP) in pure powder and formulations. The HPLC separation was achieved on a Nucleosil C8 column (150 mm length x 4.6 mm id, 5 microm particle size) using acetonitrile-phosphate buffer, pH 3.0 (55 + 45, v/v) mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60F254 using ethyl acetate-methanol-toluene-glacial acetic acid (5.0 + 1.0 + 4.0 + 0.1, v/v/v/v) mobile phase. Quantitation was achieved with UV detection at 235 nm over the concentration range 4-24 microg/mL for both drugs, with mean recoveries of 99.98 +/- 0.28 and 100.16 +/- 0.66% for ASA and CLP, respectively, using the HPLC method. Quantitation was achieved with UV detection at 235 nm over the concentration range of 400-1400 ng/spot for both drugs, with mean recoveries of 99.93 +/- 0.55 and 100.21 +/- 0.83% for ASA and CLP, respectively, using the HPTLC method. These methods are simple, precise, and sensitive, and they are applicable for the simultaneous determination of ASA and CLP in pure powder and formulations.  相似文献   

6.
A simple reversed-phase high-performance liquid chromatography (HPLC) method with ultraviolet detection at 280 nm was developed for simultaneous quantitation of furosemide and hydrochlorothiazide along with phenol red as a nonabsorbable marker for in situ permeability studies in anaesthetized rats. A jejunal segment of approximately 10 cm was isolated and cannulated in both ends for inlet and outlet solution. The perfusate was collected every 10 min, and samples were analyzed using the developed method. The mobile phase was acetonitrile-water-triethylamine-glacial acetic acid (41.5 + 57.4 + 0.1 + 0.9, adjusted to pH 5.6) at a flow rate of 1 mL/min; the run time was 9 min. The calibration graphs were linear for all 3 compounds (r > 0.999) across the concentration range of 7.93-125 microg/mL for phenol red and 6.25-100 microg/mL for hydrochlorothiazide and furosemide. The limits of quantitation were 7.2, 8.9, and 6.8 microg/mL for furosemide, hydrochlorothiazide, and phenol red, respectively. The coefficients of variation for intraassay and interassay precision were less than or equal to 7.6%, and the accuracy was between 93.2-103.4%. Using the single pass intestinal perfusion technique and the suggested HPLC method for sample analysis, mean values of 0.25 x 10(-4) (+/-0.16) cm/s and 0.22 x 10(-4) (+/-0.13) cm/s were obtained for furosemide and hydrochlorothiazide, respectively.  相似文献   

7.
Three stability-indicating assay methods were developed for the determination of tropisetron in a pharmaceutical dosage form in the presence of its degradation products. The proposed techniques are HPLC, TLC, and first-derivative spectrophotometry (1D). Acid degradation was carried out, and the degradation products were separated by TLC and identified by IR, NMR, and MS techniques. The HPLC method was based on determination of tropisetron in the presence of its acid-induced degradation product on an RP Nucleosil C18 column using methanol-water-acetonitrile-trimethylamine (65 + 20 + 15 + 0.2, v/v/v/v) mobile phase and UV detection at 285 nm. The TLC method was based on the separation of tropisetron and its acid-induced degradation products, followed by densitometric measurement of the intact spot at 285 nm. The separation was carried out on silica gel 60 F254 aluminum sheets using methanol-glacial acetic acid (22 + 3, v/v) mobile phase. The 1D method was based on the measurement of first-derivative amplitudes of tropisetron in H2O at the zero-crossing point of its acid-induced degradation product at 271.9 nm. Linearity, accuracy, and precision were found to be acceptable over concentration ranges of 40-240 microg/mL, 1-10 microg/spot, and 6-36 micro/mL for the HPLC, TLC, and 1D methods, respectively. The suggested methods were successfully applied for the determination of the drug in bulk powder, laboratory-prepared mixtures, and a commercial sample.  相似文献   

8.
This paper describes validated HPLC and HPTLC methods for the simultaneous determination of rosuvastatin (ROS) and ezetimibe (EZE) in a combined tablet dosage form. The isocratic RP-HPLC analysis was performed on a Chromolith C18 column (100 x 6 mm id) using 0.1% (v/v) orthophosphoric acid solution (pH 3.5)-acetonitrile (63 + 37, v/v) mobile phase at a flow rate of 1 mL/min at ambient temperature. Quantification was carried out using a photodiode array UV detector at 245 nm over the concentration range of 0.5-10 microg/mL for ROS and EZE. The HPTLC separation was carried out on an aluminum-backed sheet of silica gel 60F(254) layers using n-butyl acetate-chloroform-glacial acetic acid (1 + 8 + 1, v/v/v) mobile phase. Quantification was achieved with UV densitometry at 245 nm over a concentration range of 0.1-0.9 micro/spot for ROS and EZE. The analytical methods were validated according to International Conference on Harmonization guidelines. Low RSD values indicated good precision. Both methods were successfully applied for the analysis of the drugs in laboratory-prepared mixtures and commercial tablets. No chromatographic interference from the tablet excipients was found. These methods are simple, precise, and sensitive, and are applicable for simultaneous determination of ROS and EZE in pure powder and tablets.  相似文献   

9.
Two simple and accurate methods for analysis of nebivolol hydrochloride (NEB) and hydrochlorothiazide (HCTZ) in their combined dosage forms were developed using first-order derivative spectrophotometry and reversed-phase liquid chromatography (LC). NEB and HCTZ in their combined dosage forms (tablets) were quantified using first-derivative responses at 294.6 and 334.6 nm in the spectra of their solutions in methanol. The calibration curves were linear in the concentration range of 8-40 microg/mL for NEB and 10-60 microg/mL for HCTZ. LC analysis was performed on a Phenomenex Gemini C18 column (250 x 4.6 mm id, 5 microm particle size) in the isocratic mode with 0.05 M potassium dihydrogen phosphate-acetonitrile-methanol (30 + 20 + 50, v/v/v; pH 4) mobile phase at a flow rate of 1 mL/min. Detection was made at 220 nm. Both of the drugs and the internal standard (ezetimibe) were well resolved with retention times of 5.1 min for NEB, 2.9 min for HCTZ, and 8.2 min for ezetimibe. The calibration curves were linear in the concentration range of 1-14 microg/mL for NEB and 0.3-28 microg/mL for HCTZ. Both methods were validated and found to be accurate, precise, and specific, and results were compared statistically. Developed methods were successfully applied for the estimation of NEB and HCTZ in their combined dosage forms.  相似文献   

10.
A new, specific, and sensitive RP-HPLC method was developed for the simultaneous determination of eprosartan (EPR) and hydrochlorothiazide (HCT). Good chromatographic separation was achieved using a 250 x 4.6 mm id, 5 microm particle size Symmetry C18 column. The mobile phase acetonitrile-0.1 M phosphate buffer (35+65, v/v), pH 4.5, was pumped at a flow rate of 1 mL/min, with UV detection at 275 nm. The method showed good linearity in the ranges of 0.5-50 and 0.1-10 microg/mL, with LOD of 0.06 and 0.02 microg/mL and LOQ of 0.20 and 0.08 microg/mL for EPR and HCT, respectively. The proposed method was successfully applied for the analysis of the studied drugs in their synthetic mixture and co-formulated tablets. The method was further extended to the in vitro and in vivo determination of the two drugs in spiked and real human plasma. Interference likely to be encountered from the co-administered drugs was studied.  相似文献   

11.
A simple, rapid, and stability-indicating HPLC method has been developed, fully validated, and applied to the quantification of paracetamol, pseudoephedrine hydrochloride, and chlorpheniramine maleate in a pharmaceutical formulation, using hydrochlorothiazide as an internal standard. Chromatographic separation was achieved isocratically on an RP porous graphitized carbon analytical column (125 x 2.1 mm id, particle size 5 microm) using 5.0 mM ammonium acetate-acetonitrile (35 + 65, v/v) mobile phase at a flow rate of 0.50 mL/min. UV spectrophotometric detection at 220 nm was used. The method had linear calibration curves over the range of 30-70 microg/mL for paracetamol, 1.8-4.2 microg/mL for pseudoephedrine hydrochloride, and 120-280 ng/mL for chlorpheniramine maleate. The intraday and interday RSD values were less than 3.2% for all compounds, while the relative error was less than 2.9%. Accelerated stability studies performed under various stress conditions proved the selectivity of the method. The developed method was applied successfully to QC and content uniformity tests of commercial tablets.  相似文献   

12.
Simple, accurate, precise, and sensitive ultraviolet spectrophotometric and reversed-phase high-performance liquid chromatographic (RP-HPLC) methods for simultaneous estimation of escitalopram oxalate (ESC) and clonazepam (CLO) in combined tablet dosage form have been developed and validated. The spectroscopic method employs an absorbance correction method using 238.6 and 308 nm as 2 wavelengths for estimation with methanol and water as solvents. Beer's law is obeyed in the concentration range of 10.0-50.0 and 0.5-3.0 micro/mL for ESC and CLO, respectively. The RP-HPLC method uses a Jasco HPLC system with HiQ SiL C18 column (250 x 4.6 mm id) acetonitrile-0.005 M tetrabutylammonium hydrogen sulfate (55 + 45, v/v) as the mobile phase, and satranidazole as an internal standard. The detection was carried out using an ultraviolet detector set at 287 nm. For the HPLC method, Beer's law is obeyed in the concentration range of 10.0-60.0 and 0.5-3.0 microg/mL for ESC and CLO, respectively. Both methods have been successfully applied for the analysis of the drugs in a pharmaceutical formulation. Results of analysis were validated statistically and by recovery studies.  相似文献   

13.
An accurate, simple, reproducible, and sensitive HPLC method was developed and validated for the simultaneous determination of atorvastatin calcium, ezetimibe, and fenofibrate in a tablet formulation. The analyses were performed on an RP C18 column, 150 x 4.60 mm id, 5 pm particle size. The mobile phase methanol-acetonitrile-water (76 + 13 + 11, v/v/v), was pumped at a constant flow rate of 1 mL/min. UV detection was performed at 253 nm. Retention times of atorvastatin calcium, ezetimibe, and fenofibrate were found to be 2.25, 3.68, and 6.41 min, respectively. The method was validated in terms of linearity, precision, accuracy, LOD, LOQ, and robustness. The response was linear in the range 2-10 microg/mL (r2 = 0.998) for atorvastatin calcium, 2-10 microg/mL (r2 = 0.998) for ezetimibe, and 40-120 microg/mL (r2 = 0.998) for fenofibrate. The developed method can be used for routine quality analysis of the drugs in the tablet formulation.  相似文献   

14.
Three simple, rapid, and accurate methods, i.e., the derivative ratio spectra-zero-crossing method (method I), double divisor-ratio spectra derivative method (method II), and column reversed-phase high-performance liquid chromatographic (RP-HPLC) method (method III) were developed for the simultaneous determination of doxylamine succinate (DOX), pyridoxine hydrochloride (PYR), and folic acid (FA) in their ternary mixtures and in tablets. In methods I and II, the calibration graphs were linear in the range of 2.5-80, 1.0-40, and 1.0-30 microg/mL for DOX, PYR, and FA, respectively. In the HPLC method, the separation of these compounds was performed using mobile phase consisting of 0.05 M phosphate buffer (pH 6.3)-methanol-acetonitrile (50 + 20 + 30, v/v/v), and UV detection was performed at 263 nm. Linearity was observed between the concentrations of the analytes and peak areas [correlation coefficient (r) > or =0.9998] in the concentration range of 1.0-200, 4.0-600, and 4.0-600 microg/mL for DOX, PYR, and FA, respectively. The standard deviation of retention time in method III was 0.011, 0.015, and 0.016 for DOX, PYR, and FA, respectively. The precision studies for all of the methods gave relative standard deviation values of <2%. The results obtained from the methods were statistically compared by means of Student's t-test and the variance ratio F-test. It was concluded that all of the developed methods were equally accurate, sensitive, and precise. These methods could be applied to determine DOX, PYR, and FA in their combined dosage forms.  相似文献   

15.
《Analytical letters》2012,45(7):1359-1368
Abstract

An HPLC method has been developed for the determination of the beta adrenergic blocking drug metoprolol tartrate. The method is based on the formation of a Cu (II) - dithiocarbamate complex by precolumn derivatization of secondary amino group of metoprolol with CS2 and CuCl2 in the presence of ammonia. The complex is extracted into chloroform and injected into the chromatograph. Chromatographic separation was performed by a RP (μ Bondapak C18) column with methanol - pH 5.8 phosphate buffer (80 : 20) as the isocratic mobile phase. A variable wavelength absorbance detector (λ = 275 nm) was used. A linear relationship was obtained between peak areas and metoprolol tartrate concentrations over the range of 35 - 180 nmol ml?1. The method was applied to the analysis of metoprolol tartrate tablets and the results were statistically compared with those obtained by official method using t - and F - tests.  相似文献   

16.
Lv J  Pan L  Ye Y  Zhou Y 《Journal of separation science》2007,30(15):2466-2472
A sensitive and selective HPLC method with UV detection for the simultaneous determination of picroside-I and picroside-II (active components of total glycoside of Picrorhiza scrophulariiflora Pennell) was developed and validated in rat plasma. After simple deproteinization using acetonitrile, analysis was performed on an RP-C18 column (250 mm x 4.6 mm id, 5 microm) with a mobile phase consisting of acetonitrile and water at a flow rate of 1.0 mL/min used in a gradient elution program. The UV detection wavelength was set at 262 and 277 nm. Linear calibration curves were obtained in the concentration range of 0.10-50 microg/mL for picroside-I and 0.25-200 microg/mL for picroside-II. The lower limits of quantification were 0.1 and 0.25 microg/mL for picroside-I and picroside-II, respectively. The recoveries from spiked control samples were up to 80% for both picroside-I and picroside-II. Accuracy and precision of the validated method were both within the acceptable limits of <15% at three quality control concentrations. The analytes were stable after three freeze-thaw cycles. The method was successfully used to determine concentrations of picroside-I and picroside-II after intravenous administration of total glycoside of Picrorhiza scrophulariiflora Pennell to rats.  相似文献   

17.
A simple and rapid high-performance liquid chromatographic (HPLC) method with ultraviolet detection has been developed and validated for the simultaneous determination of rifampicin and sulbactam in mouse plasma. Plasma samples were deproteinized with acetonitrile and separated by HPLC on a RP-18 (125 x 4 mm, 5 microm) column and gradient elution with potassium dihydrogen phosphate solution (pH 4.5; 50 mm) and acetonitrile at a flow-rate of 1.0 mL/min. Rifampicin and sulbactam were monitored at 230 nm and confirmed by means of their UV spectra using a diode-array detector. The method was linear at plasma levels from 1 to 100 microg/mL for rifampicin and from 5 to 200 microg/mL for sulbactam. The limits of quantification were 0.6 microg/mL for rifampicin and 4.2 microg/mL for sulbactam. The intra- and inter-day precisions of the method (RSD) were lower than 5% for both compounds. Average recoveries of rifampicin and sulbactam from mice plasma were 98.2 and 89.3%, respectively. The developed method was successfully applied to the determination of the pharmacokinetic profile of both compounds in mice.  相似文献   

18.
Simple, accurate, sensitive, and precise UV spectrophotometric, chemometric, and HPLC methods were developed for simultaneous determination of a two-component drug mixture of ezetimibe (EZ) and simvastatin (SM) in laboratory-prepared mixtures and a combined tablet dosage form. Four spectrophotometric methods were developed, namely, ratio spectra derivative, ratio subtraction, isosbestic point, and mean centering of ratio spectra. The developed chemometric-assisted spectrophotometric method was the concentration residual augmented classical least-squares method; its prediction ability was assessed and compared to the conventional partial least-squares method. The developed HPLC method used an RP ZORBAX C18 column (5 microm particle size, 250 x 4.6 mm id) with isocratic elution. The mobile phase was acetonitrile-pH 3.5 phosphate buffer (40 + 60, v/v) at a flow rate of 1.0 mL/min, with UV detection at 230 nm. The accuracy, precision, and linearity ranges of the developed methods were determined. The developed methods were successfully applied for determination of EZ and SM in bulk powder, laboratory-prepared mixtures, and a combined dosage form. The results obtained were compared statistically with each other and to those of a reported HPLC method; there was no significant difference between the proposed methods and the reported method regarding both accuracy and precision.  相似文献   

19.
An HPLC method was developed for the simultaneous determination of gnaphaliin A and B, active compounds of Gnaphalium liebmannii Sch. Bp ex Klatt. The HPLC separation was performed on an Inertsil ODS-3 (150 x 4.6 mm id, 5 microm) RP C18 column operated at 40 degrees C; the isocratic mobile phase was 0.02% aqueous orthophosphoric acid-methanol-acetonitrile (50 + 30 + 20, v/v/v), with a run time of 20 min and flow rate of 1.5 mL/min. Detection with a photodiode array detector (PDAD) was at 270 nm. The method was validated for linearity, repeatability, LOD, and LOQ. The LOD and LOQ for gnaphaliin A and B were found to be in the range of 0.4-0.5 and 1.0-1.4 microg/mL, respectively. This is the first report of an analytical method developed for the quantitative analysis of flavones from Gnaphalium species by HPLC-PDAD with applications for raw material and commercial products.  相似文献   

20.
In this contribution, a new separation method for simultaneous determination of paracetamol, caffeine, acetylsalicylic acid, and internal standard benzoic acid was developed based on a novel reversed-phase sequential injection chromatography (SIC) technique with UV detection. A Chromolith Flash RP-18e, 25-4.6mm column (Merck, Germany) and a FIAlab 3000 system (USA) with an 8-port selection valve and a 5 mL syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-(0.01 M) phosphate buffer (10:90, v/v) pH 4.05, flow rate 0.6 mL min(-1). UV detection was at 210 and 230 nm. The validation parameters showed good results: linearity (r >0.999) for all compounds, detection limits in the range 0.3-0.8 microg mL(-1), repeatability (RSD) of peak heights between runs in the range 1.10-4.30% at three concentration levels and intra-day repeatability of the retention times in the range 0.28-0.43%. The analysis time was <6 min. The method was found to be applicable for the routine analysis of the active compounds paracetamol, caffeine, and acetylsalicylic acid in pharmaceutical tablets.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号