首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rehydratable dry-film plating method for Staphylococcus aureus in foods, the 3M Petrifilm Rapid S. aureus Count Plate method, was compared with AOAC Official Method 975.55 (Staphylococcus aureus in Foods). Nine foods-instant nonfat dried milk, dry seasoned vegetable coating, frozen hash browns, frozen cooked chicken patty, frozen ground raw pork, shredded cheddar cheese, fresh green beans, pasta filled with beef and cheese, and egg custard-were analyzed for S. aureus by 13 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample and 3 levels of inoculated test sample, each in duplicate. The mean log counts for the methods were comparable for pasta filled with beef and cheese; frozen hash browns; cooked chicken patty; egg custard; frozen ground raw pork; and instant nonfat dried milk. The repeatability and reproducibility variances of the Petrifilm Rapid S. aureus Count Plate method were similar to those of the standard method.  相似文献   

2.
Results with the new 3M Petrifilm Rapid S. aureus Count (RSA) Plate method were compared with those of the classical Baird-Parker agar (BPA) method for detection and enumeration of Staphylococcus aureus. Studies on 219 bacterial strains demonstrated that the Petrifilm RSA plate is more sensitive than and as specific as the classical BPA method for confirmed identification of S. aureus. Counts of colonies from 71 pure cultures, 61 naturally contaminated food samples, and more than 750 artificially inoculated food samples showed that the Petrifilm RSA method was as effective as the classical BPA method for identification and enumeration of S. aureus. The Petrifilm RSA method gave results in one-third the time required for the classical method.  相似文献   

3.
A rehydratable dry-film plating method for coliforms in foods, the 3M Petrifilm Rapid Coliform Count plate method, was compared with the U.S. Food and Drug Administration's Bacteriological Analytical Manual method for nondairy foods and the American Public Health Association's Standard Methods for the Examination of Dairy Products (SMEDP) method for dairy foods. Six food types, vanilla ice cream, cheddar cheese, fresh refrigerated uncooked pasta, wheat flour, prepared frozen macaroni and cheese, and frozen hash browns, were analyzed for coliforms by 11 collaborating laboratories. For each food product tested, the collaborators received 8 blind samples consisting of a control sample and 3 levels of inoculated sample, each in duplicate. The mean log counts for the methods were comparable. The repeatability and reproducibility variances of the Petrifilm Rapid Coliform Count method at 14 and 24 h were not significantly different from those of the standard methods.  相似文献   

4.
The 3M Petrifilm Staph Express Count plate method was compared with AOAC Official Method 975.55 for the enumeration of Staphylococcus aureus in selected foods. Five foods--ice cream, raw milk, yogurt, whey powder, and cheese--were analyzed for S. aureus by 12 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample, a low inoculation level, a medium inoculation level, and a medium inoculation level with background flora, each in duplicate. The mean log10 counts for the methods were comparable for all 5 foods. The repeatability and reproducibility variances of the 24 h Petrifilm Staph Express Count plate method were similar to those of the 72 h standard method.  相似文献   

5.
The 3M Petrifilm Staph Express Count plate method was compared with AOAC Official Method 975.55 for the enumeration of Staphylococcus aureus in selected foods. Four foods--cooked, diced chicken; cured ham; smoked salmon; and pepperoni--were analyzed for S. aureus by 12 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample, a low inoculation level, a medium inoculation level, and a medium inoculation level with background flora, each in duplicate. The mean log10 counts for the methods were comparable for all 4 foods. The repeatability and reproducibility variances of the 24 h Petrifilm Staph Express Count plate method were similar to those of the 72 h standard method.  相似文献   

6.
The 3M Petrifilm Staph Express Count plate method was compared with AOAC Official Method 975.55 for the enumeration of Staphylococcus aureus in selected foods. Five foods--frozen lasagna, custard, frozen mixed vegetables, frozen hashbrowns, and frozen batter-coated mushrooms--were analyzed for S. aureus by 13 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample, a low inoculation level, a medium inoculation level, and a medium inoculation level with background flora, each in duplicate. The mean log10 counts for the methods were comparable for all 5 foods. The repeatability and reproducibility variances of the 24 h Petrifilm Staph Express Count plate method were similar to those of the 72 h standard method.  相似文献   

7.
The relative effectiveness of the SimPlate Yeast and Mold-Color Indicator method (Y&M-CI) was compared to the U.S. Food and Drug Administration's (FDA) Bacteriological Analytical Manual (BAM) method and the proposed International Organization for Standardization (ISO) method, ISO/CD 21527, for enumerating yeasts and molds in foods. Test portions were prepared and incubated according to the conditions stated in both the BAM and ISO methods. Six food types were analyzed: frozen corn dogs, nut meats, frozen fruits, cake mix, cereal, and fresh cheese. Nut meats, frozen fruits, and fresh cheese were naturally contaminated. All other foods were artificially contaminated with either a yeast or mold. Seventeen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery between the SimPlate method and the 2 corresponding reference methods. Moreover, mean log counts between the 2 reference methods were also very similar. The repeatability (Sr) and reproducibility (SR) standard deviations were comparable between the 3 method comparisons. These results indicate that the BAM method and the SimPlate method are equivalent for enumerating yeast and mold populations in foods. Similarly, the SimPlate method is comparable to the proposed ISO method when test portions are prepared and incubated as defined in the proposed ISO method.  相似文献   

8.
Staphylococcal food poisoning is one of the most common foodborne diseases worldwide; it results from the ingestion of staphylococcal enterotoxins (SEs) in food, mainly Staphylococcus aureus. This study investigated the statistical relationships among morphological enumerations of food-derived S. aureus and production of SEs using different methodologies. Food samples naturally contaminated with coagulase-positive S. aureus were submitted for enumeration on Baird-Parker (BP) agar, Rabbit Plasma Fibrinogen agar (RPFA), and Petrifilm Staph Express count system (STX), and the morphologically typical colonies were isolated for VIDAS and real-time (RT) PCR tests. RPFA and STX displayed better performance for the enumeration of SE-positive S. aureus when compared with BP, including higher frequencies of SE-positive isolates and better correlation indices between typical and SE-positive counts. Among all the evaluated culture media, no significant difference (P > 0.05) was shown on the frequencies of typical colonies that carried 11 individual se genes. In addition, results for SE identification between VIDAS and RT-PCR assay were unparalleled. These data will be valuable for the selection of methods for inspection of food-derived S. aureus.  相似文献   

9.
Five different food types were analyzed by the Reveal for E. coli O157:H7 8-Hour Test System (Reveal 8) and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM) culture method or the U.S. Department of Agriculture Food Safety Inspection Service (FSIS) culture method for the presence of E. coli O157:H7. A total of 27 laboratories representing academia and private industry in the United States and Canada participated. Food types were inoculated with E. coli O157:H7 at 2 different levels: a high level where predominantly positive results were expected, and a low level where fractional recovery was anticipated. During this study, 1,110 samples and controls were analyzed by both the Reveal 8 and by BAM or FSIS by each of the collaborators (2,220 samples in total). For each set of samples, 740 were artificially inoculated with E. coli O157:H7, and 370 were uninoculated controls. The Reveal 8 detected 528 presumptive positives of which 487 were confirmed positive by the BAM culture method. In comparison, BAM and FSIS detected 489 of the 740 artificially contaminated samples as positive. In an additional in-house study performed only on chilled and frozen raw ground beef, 240 artificially inoculated samples were analyzed by both the Reveal 8 and by FSIS. The Reveal 8 detected and confirmed 104 samples as positive compared to 79 confirmed positive by FSIS.  相似文献   

10.
Following an industry request, a study was undertaken to validate a minor change to the Unique method for testing fruit juice. Twenty foods were tested in the original precollaborative study for TECRA Unique Salmonella test (2000.07). To validate the modification for juice, both the modified method (42 degrees C module incubation with a 5 h replication step) and the current AOAC Method 2000.07 (37 degrees C incubation with a 4 h replication step) were compared with the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM; 8th Ed., 1998) reference method, which uses lactose broth as pre-enrichment medium. Twenty uninoculated replicates, 20 replicates with low-level inoculum (target 1-5 cells/25 g), and 20 replicates with high-level inoculum (target 10-50 cells/25 g) were tested for a single batch of fresh orange juice in accordance with AOAC requirements. There was exact agreement between the 2 Unique methods for all samples and exact agreement between the 2 Unique methods and the BAM method for the uninoculated and high-level inoculum samples. For low-level inoculum, 17 samples were confirmed positive with the new Unique method, 17 with AOAC Method 2000.07, and 14 with the BAM method.  相似文献   

11.
A rehydratable dry-film plating method for Escherichia coli, the Petrifilm E. coli/Coliform (EC) Count Plate in foods, has been compared with the AOAC INTERNATIONAL most probable number (MPN) method. Eleven laboratories participated in the collaborative study. Three E. coli levels in 8 samples each of frozen raw ground turkey, frozen raw ground beef, and frozen cooked fish were tested in duplicate. Mean log counts for the Petrifilm plate procedure were not significantly different from those for the MPN procedure for cooked fish samples inoculated with low or high inocula levels, for samples of raw turkey inoculated at medium level, and for beef inoculated at low, medium, and high levels. Repeatability and reproducibility variances of the Petrifilm EC Plate method recorded at 24 h were as good as or better than those of the MPN method. The dry rehydratable film method for enumerating confirmed E. coli in poultry, meats, and seafood has been adopted first action by AOAC INTERNATIONAL.  相似文献   

12.
The practice of detecting and enumerating all oxidase-negative, glucose-fermenting-Gram-negative rods (i.e., the family Enterobacteriaceae) is used to indicate unsanitary or inadequate food processing conditions. The objective of this interlaboratory collaborative study was to evaluate and compare the methods described in Standard Methods for the Examination of Dairy Products (SMEDP) and the Compendium of Methods for the Microbiological Examination of Foods (Compendium) with a commercial product, the 3M Petrifilm Enterobacteriaceae Count Plate, for the recovery of Enterobacteriaceae in foods. Six foods--cheddar cheese, milk, flour, frozen prepared meals, frozen broccoli, and nut pieces--were analyzed for Enterobacteriaceae by 12 collaborating laboratories. For each food tested, the collaborators received 8 blind test portions consisting of a control test portion and 3 levels of inoculated test portion, each in duplicate. Each test portion was tested by the Petrifilm Enterobacteriaceae Count Plate method as well as the SMEDP or Compendium methods. The precision estimates (repeatability or within-laboratory variation, and reproducibility or between-laboratory variation) were calculated with standard statistical techniques.  相似文献   

13.
The Assurance Gold Salmonella EIA, BAX for Screening/Salmonella, and GENE-TRAK Salmonella DLP rapid assays were compared with official cultural methods described in the Bacteriological Analytical Manual (BAM) for analysis of alfalfa sprouts and sprout irrigation water for the presence of Salmonella. The lower limits of detection of 4 serovars of Salmonella cells (S. tennessee, S. muenchen, S. mbandanka, and S. cubana) in pure culture were determined as approximately log10 2, 5, and 6 for the BAX, GENE-TRAK, and Gold EIA, respectively. Despite its low detection limit, the BAX did not perform as well as the other assays in analyzing contaminated sprouts and sprout irrigation water. For 4 different lots of sprouts and sprout irrigation water samples inoculated with the 4 serovars at low [1-2 colony forming units (CFU/g)] and high (68-180 CFU/g) levels, the BAX detected Salmonella in 58/64 (90.6%) of the samples, compared with 64/64 (100%) by the GENE-TRAK, Gold EIA, and BAM methods. Assay performance was also compared for analysis of naturally contaminated sprouts and sprout irrigation water with 3 lots of alfalfa sprouted seeds associated with different salmonellosis outbreaks. Positive assay results for the naturally contaminated samples were Gold EIA 41, GENE-TRAK 36, BAM 33, and BAX 13.  相似文献   

14.
The VIDAS Immuno-concentration Salmonella ICS)/VIDAS Salmonella (SLM) immunoassay method for the detection of Salmonella was compared to the Bacteriological Analytical Manual (BAM)/AOAC culture method in a collaborative study. Thirty-two laboratories participated in the evaluation. Each laboratory tested one or more of the 6 test products: milk chocolate, nonfat dry milk, dried whole egg, soy flour, ground black pepper, and ground raw turkey. The 2 methods were in agreement for 1,266 of the 1,440 samples. Of the 174 samples not in agreement, 69 were VIDAS CS/SLM-positive and BAM/AOAC-negative and 105 were VIDAS ICS/SLM-negative and BAM/AOAC-positive.  相似文献   

15.
The VIDAS Immuno-concentration Salmonella (ICS) plus selective plate method (Hektoen enteric, bismuth sulfite, Salmonella identification) method for the detection of Salmonella was compared to the Bacteriological Analytical Manual (BAM)/AOAC culture method in a collaborative study. Thirty-two laboratories participated in the evaluation. Each laboratory tested one or more of the 6 test products: milk chocolate, nonfat dry milk, dried whole egg, soy flour, ground black pepper, and ground raw turkey. The 2 methods were in agreement for 1,283 of the 1,440 test samples. Of the 157 test samples not in agreement, 82 were VIDAS ICS plus selective plate-positive and BAM/AOAC-negative, and 75 were VIDAS ICS plus selective plate-negative and BAM/AOAC-positive.  相似文献   

16.
The VIDAS Immuno-concentration Salmonella (ICS) plus selective plate method (Hektoen enteric, xylose lysine desoxycholate, bismuth sulfite) method for the detection of Salmonella was compared to the Bacteriological Analytical Manual (BAM)/AOAC culture method in a collaborative study. Thirty-two laboratories participated in the evaluation. Each laboratory tested one or more of the 6 test products: milk chocolate, nonfat dry milk, dried whole egg, soy flour, ground black pepper, and ground raw turkey. The 2 methods were in agreement for 1,297 of the 1,455 samples. Of the 158 samples not in agreement, 82 were VIDAS ICS plus selective plate-positive and BAM/AOAC-negative, and 76 were VIDAS ICS plus selective plate-negative and BAM/AOAC-positive.  相似文献   

17.
Alternative methods of reducing oxygen during anaerobic enrichment in the Bacteriological Analytical Manual (BAM) Shigella culture method were evaluated and compared to the current and less practical GasPak method. The alternative anaerobic methods included the use of reducing agents in Shigella broth and reducing culture container headspace volume to minimize atmospheric effects on oxygen concentration in Shigella broth during enrichment. The reducing agents evaluated were sodium thioglycollate, L-cystine, L-cysteine, titanium(III) citrate, and dithiothreitol, each at concentrations of 0.1, 0.05, and 0.01%. The use of Oxyrase for Broth with the enrichment medium (Shigella broth) was evaluated at concentrations of 10, 20 and 30 microL/mL. Recoveries of chill- and freeze-stressed S. sonnei strains 357 and 20143 were determined with each anaerobic method, including the GasPak method, using inoculation levels ranging from 10(0)to 10(3) cells. For each anaerobic method, strain, inoculation level, and stress type, 5 replicate enrichments were evaluated by streaking to MacConkey agar for isolation. The numbers of cultures with each method from which S. sonnei was isolated were used to compare the alternative anaerobic methods to the GasPak method. The alternative anaerobic method with which chill- and freeze-stressed S. sonnei strains 357 and 20143 were isolated most consistently was the use of Oxyrase for Broth in Shigella broth at a concentration of 20 microL/mL. This method was compared to the GasPak anaerobic method in evaluations on the recovery of S. sonnei strains 357 and 20143 from artificially contaminated test portions of parsley, cilantro, green onions, strawberries, carrots, and celery. A third anaerobic method included the use of 0.5 cm mineral oil overlay on cultures containing Oxyrase for Broth at concentrations of 20 microL/mL. Recovery rates of strain 357 were significantly greater (p < 0.05) with the GasPak method than with Oxyrase for Broth, with and without the 0.5 cm mineral oil overlay, for test portions of parsley, cilantro, and celery. When Oxyrase for Broth was used with Shigella broth, strain 357 was isolated at higher rates from all produce types, except cilantro, when 0.5 cm mineral oil overlay was applied to enrichment cultures. The use of mineral oil overlay with Oxyrase for Broth also improved recovery of strain 20143 from test portions of all produce types except green onion and strawberries. These differences were significant (p < 0.05) with parsley, carrots, and cilantro (1 of 2 evaluations). No statistically significant differences (p > 0.05) between the GasPak and Oxyrase for Broth anaerobic methods occurred when mineral oil overlay was used with Oxyrase for Broth. The use of Oxyrase for Broth with a 0.5 cm mineral oil overlay is a practical alternative for anaerobic enrichment with the BAM method in the analysis of some produce types. Differences in recovery among the different produce types and methods occurred between S. sonnei strains 357 and 20143, emphasizing the need for additional S. sonnei strains in future evaluations.  相似文献   

18.
Casein δ34S of 725 samples of cheese from all over the world were measured using IRMS. δ34S alone made it possible to establish characteristic ranges of values for two types of Italian cheese (Grana Padano PDO and Parmigiano Reggiano PDO) and for the different regions and provinces of both the Grana Padano PDO and the Parmigiano Reggiano PDO zones. Moreover, δ34S of PDO Italian samples were compared to both Italian (not PDO) and foreign competitive cheese samples. In all the cases, sulfur isotopic ratio analysis was a powerful tool to fix characteristic ranges of values for cheeses coming from different countries and to improve the information given by other isotopic parameters.  相似文献   

19.
To obviate the need for multilocus sequencing, a method using denaturing gradient gel electrophoresis (DGGE) was developed for the multilocus sequence typing (MLST) of Staphylococcus aureus isolates. Sequence types (STs) were obtained on the basis of sequences of polymerase chain reaction (PCR) products from seven housekeeping genes and compared to the reference MLST database. The melt curves, sequences and DGGE profiles were compared for 100 STs (i) to determine PCR conditions with 40-mer GC-clamps attached to the forward and reverse primers; (ii) to choose single restriction enzyme sites for digestion of PCR products into two fragments each with a GC-clamp attached and (iii) to optimize DGGE conditions. When the DGGE types (DT) were analyzed, the majority of DTs (76/100) were accurately classified into one ST (95% of nucleotide changes were detected), 10 DTs were classified into one of two STs corresponding to a single nucleotide ambiguity and 14 DTs were classified into 3 or 4 STs corresponding to 4 or 5 nucleotide ambiguities. A combination of STs and DTs were used to obtain septuplet sets of STs (7-ST) for 25 S. aureus isolates. When compared to the reference MLST database, one methicillin-resistant S. aureus (MRSA) isolate had the same genotype as the first MRSA clone. The DGGE-MLST method can be used as a rapid, accurate and 20-fold less expensive method than DNA sequencing for the detection of all sequence types. This combined laboratory and in silico approach could have wide applicability not only to MLST methods for other bacteria but to the screening of multilocus nucleotide differences deposited in other mutation databases.  相似文献   

20.
An independent laboratory study of the BAX for Screening/E. coli O157:H7 kit was conducted at the National Food Laboratory, Inc., Dublin, CA, to complete AOAC Performance Tested Method certification. The BAX system kit was compared with the BAM culture method and a modified BAM culture method for detection of E. coli O157:H7 in ground beef. The BAX system kit detected the target organism at levels approximately 10-fold lower than those that gave positive BAM results. This study validated product claims, and Performance Tested Method status was granted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号