Accelerated Simulation Study of Space Charge Effects in Quadrupole Ion Traps Using GPU Techniques 总被引:1,自引:0,他引:1
Xingchuang Xiong Wei Xu Xiang Fang Yulin Deng Zheng Ouyang 《Journal of the American Society for Mass Spectrometry》2012,23(10):1799-1807
Space charge effects play important roles in the performance of various types of mass analyzers. Simulation of space charge effects is often limited by the computation capability. In this study, we evaluate the method of using graphics processing unit (GPU) to accelerate ion trajectory simulation. Simulation using GPU has been compared with multi-core central processing unit (CPU), and an acceleration of about 390 times have been obtained using a single computer for simulation of up to 105 ions in quadrupole ion traps. Characteristics of trapped ions can be investigated at detailed levels within a reasonable simulation time. Space charge effects on the trapping capacities of linear and 3D ion traps, ion cloud shapes, ion motion frequency shift, mass spectrum peak coalescence effects between two ion clouds of close m/z are studied with the ion trajectory simulation using GPU. 相似文献
2.
Space charge effects play important roles in ion trap operations, which typically limit the ion trapping capacity, dynamic range, mass accuracy, and resolving power of a quadrupole ion trap. In this study, a rhombic ion excitation and ejection method was proposed to minimize space charge effects in a linear ion trap. Instead of applying a single dipolar AC excitation signal, two dipolar AC excitation signals with the same frequency and amplitude but 90° phase difference were applied in the x- and y-directions of the linear ion trap, respectively. As a result, mass selective excited ions would circle around the ion cloud located at the center of the ion trap, rather than go through the ion cloud. In this work, excited ions were then axially ejected and detected, but this rhombic ion excitation method could also be applied to linear ion traps with ion radial ejection capabilities. Experiments show that space charge induced mass resolution degradation and mass shift could be alleviated with this method. For the experimental conditions in this work, space charge induced mass shift could be decreased by ~50%, and the mass resolving power could be improved by ~2 times at the same time. 相似文献
3.
4.
M Guna 《Journal of the American Society for Mass Spectrometry》2012,23(9):1602-1608
Boundary-Activated Dissociation (BAD) of multiple charge ions has been investigated in a low pressure linear ion trap (LIT) in the presence of nonlinear DC fields. Nonlinear DC fields allowed ions to be stored for a long duration at working points beyond the βy?=?0 stability boundary of the regular quadrupole fields. The ions reached large stable radial amplitude trajectories gaining high kinetic energies from the drive RF field. This led to collision activation and the formation of fragments. Experimental and simulation data showed that the degree of fragmentation was strongly dependent on the q value, Mathieu stability parameter, and the strengths of nonlinear fields. In the absence of the nonlinear fields the fragmentation efficiency was 0?% at q?=?0.23 and 17?% at q?=?0.4. In the presence of nonlinear fields BAD efficiency increased to up to 94?% at q?=?0.23 and 84?% at q?=?0.4. The broadening of the stability diagram at the βy?=?0 boundary also enabled the observation of fragment ions with higher mass-to-charge ratios (m/z) than the m/z of the precursor ions thus overcoming a major drawback of BAD of multiple-charged ions. 相似文献
5.
Black DM Payne AH Glish GL 《Journal of the American Society for Mass Spectrometry》2006,17(7):932-938
Collisional cooling rates of infrared excited ions are measured in a quadrupole ion trap (QIT) mass spectrometer at different combinations of temperature and pressure. Measurements are carried out by monitoring fragmentation efficiency of leucine enkephalin as a function of irradiation time by an infrared laser after a short excitation and incrementally increasing cooling periods. Cooling rates are observed to be directly related to bath gas pressure and inversely related to bath gas temperature. The cooling rate at typical ion trap operating pressure (1 mTorr) and temperature (room T) is faster than can be measured. At elevated temperature and the lowest pressure used for the studies, the rate of collisional cooling becomes negligible compared to the rate of radiative cooling. 相似文献
6.
Evan Xuguang Chen Michael Gehm Ryan Danell Mitch Wells Jeffrey T. Glass David Brady 《Journal of the American Society for Mass Spectrometry》2014,25(7):1295-1304
Conventionally, quadrupole ion trap mass spectrometers eject ions of different mass-to-charge ratio (m/z) in a sequential fashion by performing a scan of the rf trapping voltage amplitude. Due to the inherent sparsity of most mass spectra, the detector measures no signal for much of the scan time. By exploiting this sparsity property, we propose a new compressive and multiplexed mass analysis approach—multi Resonant Frequency Excitation (mRFE) ejection. This new approach divides the mass spectrum into several mass subranges and detects all the subrange spectra in parallel for increased mass analysis speed. Mathematical estimation of standard mass spectrum is demonstrated while statistical classification on the parallel measurements remains viable because of the sparse nature of the mass spectra. This method can reduce mass analysis time by a factor of 3–6 and increase system duty cycle by 2×. The combination of reduced analysis time and accurate compound classification is demonstrated in a commercial quadrupole ion trap (QIT) system. Figure
? 相似文献
7.
Infrared multiphoton photodissociation (IRMPD) in a quadrupole ion trap is not selective for a parent ion. Product ions are
decreased in abundance by continuous sequential dissociation and may be lost below the low mass cut-off. The IRMPD process
is made selective by resonantly exciting trapped ions into an axially offset laser path. Product ions form and collisionally
relax out of the laser path to accumulate in the center of the trap. The technique, termed selective broadband (SB) IRMPD,
limits sequential dissociation to preserve first generation product ion abundance. The abundances of larger product ions are
maximized by completely dissociating the parent ion, but continuous sequential dissociation does not form small product ions
below the low mass cut-off associated with conventional IRMPD. Smaller product ions are further increased in abundance in
another tandem mass spectrum by performing sequential stages of SB-IRMPD, adjusting the trapping rf amplitude to dissociate
larger product ions at the same qz range. Thermal assistance is used to perform SB-IRMPD at higher bath gas pressures for increased sensitivity. 相似文献
8.
The fragmentation patterns obtained by ultraviolet photodissociation (UVPD) and collision-induced dissociation (CID) in a
quadrupole ion trap mass spectrometer were compared for peptides modified at their C-termini and at acidic amino acids. Attachment
of Alexa Fluor 350 or 7-amino-4-methyl-coumarin chromophores at the C-terminal and acidic residues enhances the UV absorptivity
of the peptides and all fragment ions that retain the chromophore, such as the y ions that contain the chromophore-modified
C-terminus. Whereas CID results in the formation of the typical array of mainly y-type and a/b-type fragment ions, UVPD produces
predominantly a/b-type ions with greatly reduced abundances of y ions. Immonium ions, mostly ones from aromatic or basic amino
acids, are also observed in the low m/z range upon UVPD. UVPD of peptides containing two chromophore moieties (with one at the C-terminus and another at an acidic
residue) results in even more efficient photodissociation at the expense of the annihilation of almost all diagnostic b and
y ions containing the chromophore. 相似文献
9.
Francis O. Talbot Stephen V. Sciuto Rebecca A. Jockusch 《Journal of the American Society for Mass Spectrometry》2013,24(12):1823-1832
Laser-induced fluorescence is used to visualize populations of gaseous ions stored in a quadrupole ion trap (QIT) mass spectrometer. Presented images include the first fluorescence image of molecular ions collected under conditions typically used in mass spectrometry experiments. Under these “normal” mass spectrometry conditions, the radial (r) and axial (z) full-width at half maxima (FWHM) of the detected ion cloud are 615 and 214 μm, respectively, corresponding to ~6 % of r 0 and ~3 % of z 0 for the QIT used. The effects on the shape and size of the ion cloud caused by varying the pressure of helium bath gas, the number of trapped ions, and the Mathieu parameter q z are visualized and discussed. When a “tickle voltage” is applied to the exit end-cap electrode, as is done in collisionally activated dissociation, a significant elongation in the axial, but not the radial, dimension of the ion cloud is apparent. Finally, using spectroscopically distinguishable fluorophores of two different m/z values, images are presented that illustrate stratification of the ion cloud; ions of lower m/z (higher q z ) are located in the center of the trapping region, effectively excluding higher m/z (lower q z ) ions, which form a surrounding layer. Fluorescence images such as those presented here provide a useful reference for better understanding the collective behavior of ions in radio frequency (rf) trapping devices and how phenomena such as collisions and space-charge affect ion distribution. Figure
? 相似文献
10.
Zhou X Xiong C Xu G Liu H Tang Y Zhu Z Chen R Qiao H Tseng YH Peng WP Nie Z Chen Y 《Journal of the American Society for Mass Spectrometry》2011,22(2):386-398
The potential distribution in the curved quadrupole is exactly characterized by the Laplace equation, and an approximate solution to the Laplace equation is calculated. We represent the Laplace equation under the coordinates named minimal rotation frame (MRF) and derive an expression on the hexapole and octopole superposition. Our conclusion is in agreement with the results by the numerical (SIMION) method. Based on the Poincare-Lighthill-Kuo (PLK) method reported in our previous work, the nonlinear effects of ion motion are investigated in detail. The frequency shift of ion motion can be well eliminated by coupling the hexapole component with a positive octopole component, and the transmission efficiency of ions is found to decrease dramatically with the increase of the ionic kinetic energy in the z-direction. Furthermore, the transmission characteristics of ions are discussed with regards to the phase-space theory. The results show that the centrifugally introduced axis shift is mainly responsible for the ion losses. A modified direct current (dc) voltage supply pattern is hence proposed to compensate for this effect. 相似文献
11.
Caiqiao Xiong Xiaoyu Zhou Ning Zhang Lingpeng Zhan Suming Chen Zongxiu Nie 《Journal of the American Society for Mass Spectrometry》2014,25(11):1882-1889
Paul trap working in the second stability region has long been recognized as a possible approach for achieving high-resolution mass spectrometry (MS), which however is still far away from the experimental implementations because of the narrow working area and inefficient ion trapping. Full understanding of the ion motional behavior is helpful for solving the problem. In this article, the ion motion in a superimposed octopole field, which was characterized by the nonlinear Mathieu equation, was solved analytically using Poincare-Lighthill-Kuo (PLK) method. This method equivalently described the nonlinear disturbance by an effective quadrupole field with perturbed Mathieu parameters, a u ′ and q u ′ , which would bring huge convenience in the studies of nonlinear ion dynamics and was, therefore, used for rapid evaluation of the nonlinear effects of ion motion. Fourth-order Runge-Kutta method (4th R-K) indicated the error of PLK for characterizing the frequency shift of ion motion was within 15%. Figure
? 相似文献
12.
The kinetic energy released in the major charge-separation reactions of [C7H8]++ [C7H7]++ and [C7H6]++ formed from toluene, and in the corresponding reactions of toluene-α-d3, toluene-d8 and 2,3,4,5,6-toluene-d6 has been measured. Some fragmenting [C7]++ ions are linear; in certain cases they have cyclic structures while in others ‘coiling’ of a linear ion to allow hydrogen transfer in the transition state is suggested. From relative metastable ion abundance data it is apparent that nearly complete H/D randomization accompanies these slow reactions. 相似文献
13.
Qiankun Dang Fuxing Xu Liang Wang Xiaohua Huang Xinhua Dai Xiang Fang Rizhi Wang Chuan-Fan Ding 《Journal of the American Society for Mass Spectrometry》2016,27(4):596-606
The ion enhanced activation and collision-induced dissociation (CID) by simultaneous dipolar excitation of ions in the two radial directions of linear ion trap (LIT) have been recently developed and tested by experiment. In this work, its detailed properties were further studied by theoretical simulation. The effects of some experimental parameters such as the buffer gas pressure, the dipolar excitation signal phases, power amplitudes, and frequencies on the ion trajectory and energy were carefully investigated. The results show that the ion activation energy can be significantly increased by dual-direction excitation using two identical dipolar excitation signals because of the addition of an excitation dimension and the fact that the ion motion radius related to ion kinetic energy can be greater than the field radius. The effects of higher-order field components, such as dodecapole field on the performance of this method are also revealed. They mainly cause ion motion frequency shift as ion motion amplitude increases. Because of the frequency shift, there are different optimized excitation frequencies in different LITs. At the optimized frequency, ion average energy is improved significantly with relatively few ions lost. The results show that this method can be used in different kinds of LITs such as LIT with 4-fold symmetric stretch, linear quadrupole ion trap, and standard hyperbolic LIT, which can significantly increase the ion activation energy and CID efficiency, compared with the conventional method. 相似文献
14.
L. A. Hamlow Y. Zhu Zachary J. Devereaux N. A. Cunningham G. Berden J. Oomens M. T. Rodgers 《Journal of the American Society for Mass Spectrometry》2018,29(11):2125-2137
Modifications to a Paul-type quadrupole ion trap mass spectrometer providing optical access to the trapped ion cloud as well as hardware and software for coupling to a table-top IR optical parametric oscillator laser (OPO) are detailed. Critical experimental parameters for infrared multiple photon dissociation (IRMPD) on this instrument are characterized. IRMPD action spectra, collected in the hydrogen-stretching region with this instrument, complemented by spectra in the IR fingerprint region acquired at the FELIX facility, are employed to characterize the structures of the protonated forms of 2-thiouridine, [s2Urd+H]+, and 4-thiouridine, [s4Urd+H]+. The measured spectra are compared with predicted linear IR spectra calculated at the B3LYP/6-311+G(d,p) level of theory to determine the conformers populated in the experiments. This comparison indicates that thiation at the 2- or 4-positions shifts the protonation preference between the 2,4-H tautomer and 4-protonation in opposite directions versus canonical uridine, which displays a roughly equal preference for the 2,4-H tautomer and O4 protonation. As found for canonical uridine, protonation leads to a mixture of conformers exhibiting C2′-endo and C3′-endo sugar puckering with an anti nucleobase orientation being populated for both 2- and 4-thiated uridine. 相似文献
15.
David Derkits Alex Wiseman Russell F. Snead Martina Dows Jasmine Harge Jared A. Lamp Scott Gronert 《Journal of the American Society for Mass Spectrometry》2016,27(2):339-343
A new, variable-temperature mass spectrometer system is described. By applying polyimide heating tape to the end-cap electrodes of a Bruker (Bremen, Germany) Esquire ion trap, it is possible to vary the effective temperature of the system between 40 and 100°C. The modification does not impact the operation of the ion trap and the heater can be used for extended periods without degradation of the system. The accuracy of the ion trap temperatures was assessed by examining two gas-phase equilibrium processes with known thermochemistry. In each case, the variable-temperature ion trap provided data that were in good accord with literature data, indicating the effective temperature in the ion trap environment was being successfully modulated by the changes in the set-point temperatures on the end-cap electrodes. The new design offers a convenient and effective way to convert commercial ion trap mass spectrometers into variable-temperature instruments. 相似文献
16.
The vanadium trapping effect of Mg and La containing additives in cracking catalyst contaminated with 2300 ppm Ni and 4700 ppm V has been analyzed by microactivity test (MAT) and imaging secondary ion mass spectrometry (SIMS). The results of SIMS imaging are consistent with cracking activity data and show that the La/spinel is a superior vanadium trap for the fluid catalytic cracking of hydrocarbons (FCC) operation. La/spinel serves as a dual function additive for both vanadium trap and SOx removal. The optimum amount of La/spinel added to the cracking catalyst is about 15% by weight. This results in an increased catalytic activity, an increase in gasoline yield, and a decrease in coke and gas factors. The MgAl2O4 phase of Mg/Al2O3 additive is found capable of trapping vanadium while its MgO of Mg/Al2O3 phase can migrate to zeolite particles (the active component of the FCC catalyst) that, in turn, causes a decline in the activity of that catalyst. 相似文献
17.
18.
Dalton T. Snyder R. Graham Cooks 《Journal of the American Society for Mass Spectrometry》2016,27(12):1914-1921
A method of fragmenting ions over a wide range of m/z values while balancing energy deposition into the precursor ion and available product ion mass range is demonstrated. In the method, which we refer to as “multigenerational collision-induced dissociation”, the radiofrequency (rf) amplitude is first increased to bring the lowest m/z of the precursor ion of interest to just below the boundary of the Mathieu stability diagram (q = 0.908). A supplementary AC signal at a fixed Mathieu q in the range 0.2–0.35 (chosen to balance precursor ion potential well depth with available product ion mass range) is then used for ion excitation as the rf amplitude is scanned downward, thus fragmenting the precursor ion population from high to low m/z. The method is shown to generate high intensities of product ions compared with other broadband CID methods while retaining low mass ions during the fragmentation step, resulting in extensive fragment ion coverage for various components of complex mixtures. Because ions are fragmented from high to low m/z, space charge effects are minimized and multiple discrete generations of product ions are produced, thereby giving rise to “multigenerational” product ion mass spectra. 相似文献
19.
Examination of the collisional cooling effect of the buffer gases on ion trapping and detection in an ion trap mass spectrometer has been undertaken by the SIMION 3D program. Computation for the kinetic energy of ions under various conditions was used to account for the effects of collisional cooling of ions. Several parameters that may affect the collisional cooling effects of ions are evaluated including the existence and the variation of pressure of the buffer gas; the temperature of the ion trap; the size of the inner radius of the ion trap electrodes; the mass to charge ratio of ions; the alternative buffer gases and the qz. values which establish the ion trap trapping environment. 相似文献
20.
Thomas Junkers Edgar H. H. Wong Zachary Szablan Thomas P. Davis Martina H. Stenzel Christopher Barner‐Kowollik 《Macromolecular rapid communications》2008,29(6):503-510
A pathway for marking of polymer chains with radical spin traps during pulsed laser polymerization in free radical polymerization is presented. By introducing a so‐called marker that forms a non‐propagating radical at (or shortly after) the incidence of a laser pulse, a polymer subdistribution is generated by specifically terminating propagating radicals via combination with such a marker radical. The generated polymer subdistribution can subsequently be imaged by modern soft‐ionization mass spectrometry. Herein, the general methodology of the method in which such marker is generated via reaction of an initiating radical with a nitrone is demonstrated on the examples of BA and VAc.