首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In the present work, dispersive liquid-liquid microextraction based on solidification of floating organic drop was developed as a simple and rapid technique for separation of silver ions from aqueous samples. In this technique, 700 μL 0.02% of 5-(4'-dimethylamino benzyliden)-rhodanine (chelating agent) was added into the 10 mL analyte sample in a test tube and 30.0 μL 1-undecanol (extraction solvent) was injected shortly thereafter. The test tubes were sonicated, centrifuged and then some effective parameters on extraction and complex formation, such as type and volume of extraction and disperser solvent, pH, the amount of chelating agent and extraction time were optimized. The effect of the interfering ions on the analytes recovery was also investigated. The calibration graph was linear in the range of 0.10-10.0 ng mL(-1) with detection limit of 0.056 ng mL(-1) (n=8). The relative standard deviation (RSD) was ±4.3% (n=8, C=5.0 ng mL(-1)) and the enrichment factor was 250.0. The proposed method was applied for extraction and determination of silver in different water samples.  相似文献   

2.
建立了悬浮固化分散液液微萃取(SFO-DLLME)结合高效液相色谱(HPLC)快速测定水样中6种邻苯二甲酸酯(PAEs)的分析方法。通过对影响萃取效率因素的优化,确定了最佳萃取条件:十二烷醇萃取剂20 μL、萃取温度60℃、离子强度20 g/L、萃取时间1 min。6种PAEs在2~2000 μg/L范围内呈良好的线性关系,相关系数(r)为0.9995~0.9999,检出限(S/N=3)为0.3~0.6 μg/L。对自来水、湖水、江水、污水、海水、市售塑料瓶装纯净水和矿泉水进行测定,能检测到部分PAEs。对加标水样进行回收率试验(10、100和1000 μg/L),6种PAEs的回收率为84.9%~94.5%,相对标准偏差为4.1%~6.8%(n=5)。该法环保、简单,可用于实际水样中6种PAEs的检测分析。  相似文献   

3.
建立了以十一醇为萃取剂,吡咯烷二硫代甲酸铵(APDC)为螯合剂的浮动液滴固化分散液相微萃取-火焰原子吸收光谱法(DLLME-SFO-FAAS)测定环境样品中痕量镉的分析方法;优化了分散剂、萃取剂的类型和体积,考察了溶液pH值、APDC浓度以及萃取温度和时间对萃取效率的影响.结果表明,该法检出限(3σ)为0.14μg/L...  相似文献   

4.
A rapid, sensitive and environmentally friendly method for the analysis of 14 anilines in water samples by dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME-SFO) prior to gas chromatography–mass spectrometry (GC-MS) was developed and optimized. In the proposed method, cyclohexane was used as the extraction solvent as its toxicity was much lower than that of the solvent usually used in dispersive liquid–liquid microextraction (DLLME). In the optimized conditions, the method exhibited good analytical performance. Based on a signal-to-noise ratio of 3, limits of detection for anilines were in the range of 0.07 to 0.29 μg L−1, and the linear range was 0.5–200 μg L−1 with regression coefficients (r 2) higher than 0.9977. It was efficient for qualitative and quantitative analysis of anilines in water samples. The relative standard deviations varied from 2.9 to 8.6 % depending on different compounds indicating good precision. Tap water and river water were selected for evaluating the application to real water samples. The relative recoveries of anilines for the two real samples spiked with 10 μg L−1 anilines were in the scope of 78.2–114.6 % and 77.3–115.6 %, respectively.  相似文献   

5.
A dispersive liquid-liquid microextraction method based on solidification of a floating organic drop (DLLME-SFO) was developed for HPLC determination of β-carotene in human serum. A narrow-neck glass tube was used for simple and rapid collection of the solidified organic phase from aqueous surface after its centrifugation and cooling in a water bath. Acetone and 2-decanol were used as the disperser and organic phases, respectively. Effects of salt concentration and phase volumes on the extraction of the analyte were optimized using a central composite design method. During the optimization, a spectrophotometric method was used for determinations. Under the optimized conditions, an extraction recovery of 99.0 ± 2.4% was obtained for five replicated analyses of β-carotene with an enrichment factor of 40. A detection limit of 0.08 μg/mL was achieved. The proposed method was successfully applied to the determination of β-carotene in human serum samples.  相似文献   

6.
A novel dispersive liquid-liquid microextraction based on solidification of floating organic drop (DLLME-SFO) for separation/preconcentration of ultra trace amount of vanadium and its determination with the electrothermal atomic absorption spectrometry (ETAAS) was developed. The DLLME-SFO behavior of vanadium (V) using N-benzoyl-N-phenylhydroxylamine (BPHA) as complexing agent was systematically investigated. The factors influencing the complex formation and extraction by DLLME-SFO method were optimized. Under the optimized conditions: 100 μL, 200 μL and 25 mL of extraction solvent (1-undecanol), disperser solvent (acetone) and sample volume, respectively, an enrichment factor of 184, a detection limit (based on 3Sb/m) of 7 ng L−1 and a relative standard deviation of 4.6% (at 500 ng L−1) were obtained. The calibration graph using the preconcentration system for vanadium was linear from 20 to 1000 ng L−1 with a correlation coefficient of 0.9996. The method was successfully applied for the determination of vanadium in water and parsley.  相似文献   

7.
何静  叶曦雯  汤志旭  牛增元  罗忻  邹立 《色谱》2020,38(6):679-686
建立了悬浮固化-分散液液微萃取结合液相色谱-串联质谱测定纺织废水中5种痕量磷系阻燃剂的方法。通过对萃取过程中萃取剂、分散剂的种类与体积、盐浓度、溶液pH值等对萃取效率的影响因素优化,确立了最佳萃取条件。采用了密度小于水的十一烷醇(400μL)为萃取剂,甲醇(300μL)为分散剂,控制溶液pH值在6~9之间,NaCl添加量为2 g,萃取时间为涡旋2 min。在优化的萃取条件下,该方法在2~100μg/L均有良好的线性关系,相关系数大于0.995,除二(2,3-二溴丙基)磷酸酯(BIS)的检出限为5μg/L外,三(2-氯乙基)磷酸酯(TCEP)、三(1,3-二氯-异丙基)磷酸酯(TDCP)、三(1-氮丙啶基)氧化膦(TEPA)和三(2,3-二溴丙基)磷酸酯(TRIS)的检出限均为2μg/L。后整理、染色和印花等实际废水样品加标试验表明,方法的平均回收率为71.6%~114.5%, RSD为2.7%~11.2%(n=6)。对11个样品进行检测,其中3个废水样品检出TCEP与TDCP化合物,含量为2.6~3.4μg/L。本方法简单,快速,灵敏度好且环保绿色,能够对纺织废水中的5种痕量磷系阻燃剂...  相似文献   

8.
建立了以二乙基二硫代氨基甲酸钠为配位剂,十二醇为萃取剂,乙醇为分散剂的悬浮固化分散液-液微萃取—火焰原子吸收光谱法测定水样中痕量铅的方法。详细探讨了影响萃取效率的因素。优化条件为:二乙基二硫代氨基甲酸钠的用量为10-6 mol,十二醇体积为90.00μL,乙醇体积为1.00 mL,pH为7.00。在最佳条件下,铅的检出限为1.12μg/L,富集倍率为16.00,线性范围5.00~600.00μg/L,对含有20.00μg/L和600.00μg/L Pb的标准溶液平行萃取测定11次,测定结果的RSD分别为3.73%和2.62%。本方法应用于自来水、河水及海水中痕量铅的分析,加标回收率为90.10%~100.70%。  相似文献   

9.
In the present study, a new and versatile liquid-phase microextraction method is described. This method requires very simple and cheap apparatus and also a small amount of organic solvent. Eight microliters of 1-undecanol was delivered to the surface of solution containing analytes and solution was stirred for a desired time. Then sample vial was cooled by inserting it into an ice bath for 5 min. The solidified 1-undecanol was transferred into a suitable vial and immediately melted; then, 2 μL of it was injected into a gas chromatograph for analysis.Some polycyclic aromatic hydrocarbons (PAHs) were used as model compounds for developing and evaluating of the method performance. Analysis was carried out by gas chromatography/flame ionization detection (GC/FID).Several factors influencing the microextraction efficiency, such as the nature and volume of organic solvent, the temperature and volume of sample solution, stirring rate and extraction time were investigated and optimized. The applicability of the technique was evaluated by determination of trace amounts of PAHs in environmental samples. Under the optimized conditions, the detection limits (LOD) of the method were in the range of 0.07-1.67 μg L−1 and relative standard deviations (R.S.D.) for 10 μg L−1 PAHs were <7%. A good linearity (r2 > 0.995) in a calibration range of 0.25-300.00 μg L−1 was obtained. After 30 min extraction duration, enrichment factors were in the range of 594-1940. Finally, the proposed method was applied to the determination of trace amounts of PAHs in several real water samples, and satisfactory results were resulted. Since very simple devices were used, this new technique is affordable, efficient, and convenient for extraction and determination of low concentrations of PAHs in water samples.  相似文献   

10.
In this study, the steroid hormone levels in river and tap water samples were determined by using a novel dispersive liquid-liquid microextraction method based on the solidification of a floating organic drop (DLLME-SFO). Several parameters were optimized, including the type and volume of the extraction and dispersive solvents, extraction time, and salt effect. DLLME-SFO is a fast, cheap, and easy-to-use method for detecting trace levels of samples. Most importantly, this method uses less-toxic solvent. The correlation coefficient of the calibration curve was higher than 0.9991. The linear range was from 5 to 1000 μg L−1. The spiked environmental water samples were analyzed using DLLME-SFO. The relative recoveries ranged from 87% to 116% for river water (which was spiked with 4 μg L−1 for E1, 3 μg L−1 for E2, 4 μg L−1 for EE2 and 9 μg L−1 for E3) and 89% to 102% for tap water (which was spiked with 6 μg L−1 for E1, 5 μg L−1 for E2, 6 μg L−1 for EE2 and 10 μg L−1 for E3). The detection limits of the method ranged from 0.8 to 2.7 μg L−1 for spiked river water and 1.4 to 3.1 μg L−1 for spiked tap water. The methods precision ranged from 8% to 14% for spiked river water and 7% to 14% for spiked tap water.  相似文献   

11.
A novel,simple,rapid,efficient and environment-friendly method for the determination of trace copper in cereal samples was developed by using dispersive liquid-liquid microextraction based on solidification of floating organic drop(DLLME-SFO) followed by flame atomic absorption spectrometry.In the DLLME-SFO,copper was complexed with 8-hydroxy quinoline and extracted into a small volume of 1-dodecanol,which is of low density,low toxicity and proper melting point near room temperature. The experimental parameters affecting the extraction efficiency were investigated and optimized.Under the optimum conditions, the calibration graph exhibited linearity over the range of 0.5—500 ng/mL with the correlation coefficient(r) of 0.9996.The enrichment factor was 122 and the limit of detection was 0.1 ng/mL.The method was applied to the determination of copper in the complex matrix samples such as rice and millet with the recoveries for the spiked samples at 5.0 and 10.0 u,g/g falling in the range of 92.0-98.0%and the relative standard deviation of 3.9-5.7%.  相似文献   

12.
袁继委  王金成  徐威力  徐方曦  卢宪波 《色谱》2020,38(11):1308-1315
多环芳烃和酞酸酯是国际公认的优控污染物,因此准确快速地测定水中多环芳烃和酞酸酯非常重要。凝固漂浮有机液滴-分散液液微萃取(DLLME-SFO)是一种简便、快速、环境友好、灵敏度高的样品前处理技术。采用DLLME-SFO同时测定地表水中多环芳烃和酞酸酯的分析方法鲜有报道。该文采用凝固漂浮有机液滴-分散液液微萃取富集技术,结合高效液相色谱紫外/荧光法,建立了同时测定地表水中16种多环芳烃和6种酞酸酯的分析方法。考察优化了影响萃取效率的主要因素,包括萃取剂的种类和用量、分散剂的种类和用量、萃取时间和离子强度等。优化后的萃取实验条件为:5.0 mL水样,10μL十二醇为萃取溶剂,500μL甲醇为分散溶剂,涡旋振荡时间2 min,氯化钠用量0.2 g。目标化合物经多环芳烃专用色谱柱(SUPELCOSILTM LC-PAH, 150 mm×4.6 mm, 5μm)结合乙腈-水梯度洗脱分离,16种多环芳烃除苊烯外采用荧光检测,苊烯和6种酞酸酯采用紫外检测,外标法定量。结果表明,22种目标化合物的基质加标回收率为60.2%~113.5%,相对标准偏差为1.9%~14.3%;多环芳...  相似文献   

13.
A new dispersive liquid-liquid microextraction based on solidification of floating organic droplet method (DLLME-SFO) was developed for the determination of five kinds of polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. In this method, no specific holder, such as the needle tip of microsyringe and the hollow fiber, is required for supporting the organic microdrop due to the using of organic solvent with low density and proper melting point. Furthermore, the extractant droplet can be collected easily by solidifying it in the lower temperature. 1-Dodecanol was chosen as extraction solvent in this work. A series of parameters that influence extraction were investigated systematically. Under optimal conditions, enrichment factors (EFs) for PAHs were in the range of 88-118. The limit of detections (LODs) for naphthalene, diphenyl, acenaphthene, anthracene and fluoranthene were 0.045, 0.86, 0.071, 1.1 and 0.66 ng mL−1, respectively. Good reproducibility and recovery of the method were also obtained. Compared with the traditional liquid-phase microextraction (LPME) and dispersive liquid-liquid microextraction (DLLME) methods, the proposed method obtained about 2 times higher enrichment factor than those in LPME. Moreover, the solidification of floating organic solvent facilitated the phase transfer. And most importantly, it avoided using high-density and toxic solvent in the traditional DLLME method. The proposed method was successfully applied to determinate PAHs in the environmental water samples. The simple and low-cost method provides an alternative method for the analysis of non-polar compounds in complex environmental water.  相似文献   

14.
A dispersive liquid–liquid microextraction procedure based on solidification of floating organic droplet has been investigated for the determination of fungicides (cyprodinil, difenoconazole, myclobutanil, and spiroxamine) in sediments by HPLC with diode array detection. In the overall extraction process, the extraction solvents can be separated easily from the sample solution, and the experiment time was shortened. Moreover, several parameters such as the type and volume of the extraction solvent and dispersive solvent, centrifugal speed, extraction time, and salt effect that affect the extraction efficiencies of the target fungicides were studied and optimized. Under the optimized conditions, the LOD for the target analytes were in the range of 0.1–0.5 μg/g. Satisfactory recoveries of the target analytes in the sediment samples were 81.00–99.00%, with RSDs (n = 5) that ranged from 1.8 to 6.5%. Finally, the simple, sensitive, and environmentally friendly method was successfully applied to determine the target fungicides in actual sediment samples.  相似文献   

15.
A simple dispersive liquid-liquid microextraction (DLLME) method based on solidification of a floating organic drop (DLLME-SFO) technique combined with gas chromatography/electron-capture detection (GC/ECD) or gas chromatography/mass spectrometry (GC/MS) has been developed. The proposed method is simple, low in cost, and of high precision. It overcomes the most important problem in DLLME, the high-toxic solvent used. Halogenated organic compounds (HOCs) in water samples were determined as the model compounds. The parameters optimized for the DLLME-SFO technique were as follows: A mixture of 0.5 mL acetone, containing 10 microL 2-dodecanol (2-DD-OH), was rapidly injected by syringe into the 5 mL water sample. After centrifugation, the fine 2-DD-OH droplets (8+/-0.5 microL) were floated at the top of the screwcap test tube. The test tube was then cooled in an ice bath. After 5 min the 2-DD-OH solvent had solidified and was then transferred into a conical vial; it melted quickly at room temperature and 3 microL (for GC/ECD) or 2 microL (for GC/MS) of it was injected into a gas chromatograph for analysis. The limit of detection (LOD) for this technique was 0.005-0.05microgL(-1) for GC/ECD and was 0.005-0.047 microgL(-1) for GC/MS, respectively. The linear range of the calibration curve of DLLME-SFO was from 0.01 to 500 microgL(-1) with a coefficient of estimation (r2)>0.996 for GC/ECD and was from 0.02 to 500 microgL(-1) with a coefficient of estimation (r2)>0.996 for GC/MS.  相似文献   

16.
SPE joined with dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME‐SFO) as a novel technique combined with GC with electron‐capture detection has been developed as a preconcentration technique for the determination of organochlorine pesticides (OCPs) in water samples. Aqueous samples were loaded onto multiwalled carbon nanotubes as sorbent. After the elution of the desired compounds from the sorbent by using acetone, the DLLME‐SFO technique was performed on the obtained solution. Variables affecting the performance of both steps such as sample solution flow rate, breakthrough volume, type and volume of the elution, type and volume of extraction solvent and salt addition were studied and optimized. The new method provided an ultra enrichment factor (8280–28221) for nine OCPs. The calibration curves were linear in the range of 0.5–1000 ng/L, and the LODs ranged from 0.1–0.39 ng/L. The RSD, for 0.01 μg/L of OCPs, was in the range of 1.39–13.50% (n = 7). The recoveries of method in water samples were 70–113%.  相似文献   

17.
A novel and sensitive dispersive liquid–liquid microextraction method based on the solidification of the floating organic drop combined with high‐performance liquid chromatography and ultraviolet detection was used for the determination of atorvastatine in blood serum samples. The chromatographic separation of atorvastatin was carried out using methanol as the mobile phase organic modifier. Various parameters affecting the extraction efficiency were optimized, such as the kind and volume of extraction solvent (1‐undecanol) and disperser solvent (acetonitrile), pH, and the extraction time. The calibration curve was linear in the range of 0.2–6000 μg/L of atorvastatin (r2 = 0.995) with a limit of detection of 0.07 μg/L. The relative standard deviation for 100 μg/L of atorvastatin in human plasma was 8.4% (n = 4). The recoveries of plasma samples spiked with atorvastatin were in the range of 98.8–113.8%. The obtained results showed that the proposed method is fast, simple, and reliable for the determination of very low concentrations of atorvastatin in human plasma samples.  相似文献   

18.
朱婧  李明昕  王倩  任琳  郑波  雍莉  邹晓莉 《色谱》2016,34(11):1120-1125
建立了悬浮固化分散液液微萃取-毛细管电泳法同时测定水中磺酰脲类除草剂残留的方法。以十二醇为萃取剂、甲醇为分散剂,采用悬浮固化分散液液微萃取技术对水样进行分离提取,并结合毛细管电泳法进行测定。该方法可以有效提取、分离、检测水中残留的微量苯磺隆、吡嘧磺隆、苄嘧磺隆等9种磺酰脲类除草剂,各待测物在10.0~1000 μg/L范围内线性关系良好,相关系数r≥0.992,方法检出限为2.40~7.50 μg/L,方法精密度为6.55%~13.9%。将该方法用于实际水样的测定,取得了较满意的结果,加标回收率为82.0%~104%。该方法简便快速,适合水中磺酰脲类除草剂的同时测定。  相似文献   

19.
付博  张吉苹  周璐  姜晖 《色谱》2017,35(5):533-537
建立了漂浮液滴固化分散液液微萃取(DLLME-SFO)方法,以脂肪酸作为萃取剂,以甲醇作为分散剂,与高效液相色谱联用检测了环境水样中3种烷基苯酚。对影响前处理方法的因素进行了详细考察,在最佳萃取条件(60μL萃取剂辛酸、600μL分散剂甲醇、pH值为2.0~8.0、10 mL水样中加入0.5 g NaCl)下,3种烷基苯酚在20~1 500μg/L范围内具有良好的线性关系,相关系数不小于0.998 5,3种目标化合物的检出限为0.45~0.61μg/L,富集倍数为145~169,实际样品中3个水平的加标回收率为80.1%~109.9%。该方法将脂肪酸作为萃取剂,与HPLC联用实现了烷基苯酚的富集与检测,为环境水样中烷基苯酚的检测提供了对环境友好的前处理新方法。  相似文献   

20.
王宇  朱成华  邹晓莉  黄黎志  严冬 《色谱》2013,31(11):1076-1080
建立了溶剂去乳化-悬浮固化分散液液微萃取技术结合气相色谱-质谱联用技术同时测定水样中8种有机氯农药的方法。以正十六烷作为萃取剂,将其与分散剂丙酮混合后,快速注入水样,获得乳化体系并完成萃取;然后加入丙酮作为去乳化剂破坏乳化体系,不需要经过离心即能使两相分层;经冰浴冷冻使其固化后,取出上层凝固的有机相(正十六烷)在室温下融化,取上清液进行GC-MS分析。考察了萃取剂、分散剂、去乳化剂的种类和体积,水样盐浓度和pH值对萃取效率的影响。结果表明,8种有机氯农药在0.025~2.00 μg/L范围内有良好的线性关系(r=0.9995~0.9999), 8种有机氯农药的检出限为0.012~0.024 μg/L,精密度为3.15%~4.53%,富集倍数为96~101。将该方法应用于农田池塘水的测定,加标回收率为96.77%~102.93%,精密度为2.68%~4.86%。方法快速灵敏,有机溶剂消耗少,对环境友好,操作简便,适用于水中有机氯农药的批量分析,并为实现其样品前处理的自动化提供了技术和方法学的支持。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号