首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Mass-selected polyatomic cations and anions, produced by electrosonic spray ionization (ESSI), were deposited onto polycrystalline Au or fluorinated self-assembled monolayer (FSAM) surfaces by soft landing (SL), using a rectilinear ion trap (RIT) mass spectrometer. Protonated and deprotonated molecules, as well as intact cations and anions generated from such molecules as peptides, inorganic catalysts, and fluorescent dyes, were soft-landed onto the surfaces. Analysis of the modified surfaces was performed in situ by Cs+ secondary ion mass spectrometry (SIMS) using the same RIT mass analyzer to characterize the sputtered ions as that used to mass select the primary ions for SL. Soft-landing times as short as 30 s provided surfaces that yielded good quality SIMS spectra. Chemical reactions of the surfaces modified by SL were generated in an attached reaction chamber into which the surface was transferred under vacuum. For example, a surface on which protonated triethanolamine had been soft landed was silylated using vapor-phase chlorotrimethylsilane before being returned still under vacuum to the preparation chamber where SIMS analysis revealed the silyloxy functionalization. SL and vapor-phase reactions are complementary methods of surface modification and in situ surface analysis by SIMS is a simple way to characterize the products produced by either technique.  相似文献   

2.
This work reports a comparison of oligomer and fragment ion intensities resulting from primary ion bombardment with several primary ion sources (Bin+, C60+, and Cs+) at various energies in secondary ion mass spectrometry (SIMS). Although the use of polyatomic primary ions are of great interest due to increased secondary ion efficiency and yield, we demonstrate that monatomic primary ions result in increased oligomer ion yield for polymers prepared as submonolayer films on silver substrates. The enhancement of oligomer secondary ion yield with monatomic ions is evidence that monatomic primary ions have a shallower sampling depth than polyatomic ions, resulting from a collision cascade that is less energetic at the sample surface. The results are also consistent with a lower degree of fragmentation of the resultant secondary ions, which is observed when evaluating the fragmentation data and the spectral data.  相似文献   

3.
Static secondary ion mass spectrometry (S-SIMS) emerges as one of the most adequate methods for the surface characterisation of polymers with an information depth of essentially one monolayer. The continuing search for increased analytical sensitivity and specificity has led to exploring the use of polyatomic primary ions as an alternative to the traditionally applied monoatomic projectiles. As part of a systematic investigation on polyatomic bombardment of organic and inorganic solids, this paper focuses on selected polyesters. Mass spectra and ion yields are compared for layers deposited on silicon wafers by spincoating solutions with different concentrations of poly(epsilon-caprolactone) (PCL), poly(butylene adipate) (PBA) and poly(ethylene adipate) (PEA). Accurate mass measurements have been used to support the assignment of the ions and link the composition of the detected ions to the analyte structure. Use of polyatomic projectiles increases the yield of structural ions with a factor of +/-15, +/-30 and +/-10 for PCL, PBA and PEA, respectively, in comparison to bombardment with Ga+ primary ions, while the molecular specificity is improved by the detection of additional high m/z ions.  相似文献   

4.
This article reviews the recent progress in the understanding of kiloelectronvolt particle interactions with organic solids, including atomic displacements in a light organic medium, vibrational excitation and desorption of fragments and entire molecules. This new insight is the result of a combination of theoretical and experimental approaches, essentially molecular dynamics (MD) simulations and secondary ion mass spectrometry (SIMS). Classical MD simulations provide us with a detailed microscopic view of the processes occurring in the bombarded target, from the collision cascade specifics to the scenarios of molecular emission. Time-of-flight SIMS measures the mass and energy distributions of sputtered ionized fragments and molecular species, a precious source of information concerning their formation, desorption, ionization and delayed unimolecular dissociation in the gas phase. The mechanisms of energy transfer and sputtering are compared for bulk molecular solids, organic overlayers on metal and large molecules embedded in a low-molecular weight matrix. These comparisons help understand some of the beneficial effects of metal substrates and matrices for the analysis of molecules by SIMS. In parallel, I briefly describe the distinct ionization channels of molecules sputtered from organic solids and overlayers. The specific processes induced by polyatomic projectile bombardment, especially fullerenes, are discussed on the basis of new measurements and calculations. Finally, the perspective addresses the state-of-the-art and potential developments in the fields of surface modification and analysis of organic materials by kiloelectronvolt ion beams.  相似文献   

5.
The application of polyatomic primary ions is a strongly developing branch of static secondary ion mass spectrometry (S-SIMS), since these projectiles allow a significant increase in the secondary ion yields to be achieved. However, the different limitations and possibilities of certain polyatomic primary ions for use on specific functional classes of samples are still not completely known. This paper compares the use of monoatomic and polyatomic primary ions in S-SIMS for thin layers of polylactic acid (PLA), obtained by spin-coating solutions on silicon wafers. Bombardment with Ga+, Xe+ and SF5+ primary ions allowed the contribution of the projectile mass and number of atoms in the gain in ion yield and molecular specificity (relative importance of high m/z and low m/z signals) to be assessed. Samples obtained by spin-coating solutions with increasing concentration showed that optimal layer thickness depended on the primary ion used. In comparison with the use of Ga+ projectiles, the yield of structural ions increased by a factor of about 1.5 to 2 and by about 7 to 12 when Xe+ and SF5+ primary ion bombardment were applied, respectively. A detailed fragmentation pattern was elaborated to interpret ion signal intensity changes for different projectiles in terms of energy deposition and collective processes in the subsurface, and the internal energy of radical and even-electron precursor ions.  相似文献   

6.
Recent developments in desorption/ionisation mass spectrometry techniques have made their application to biological analysis a realistic and successful proposition. Developments in primary ion source technology, mainly through the advent of polyatomic ion beams, have meant that the technique of secondary ion mass spectrometry (SIMS) can now access the depths of information required to allow biological imaging to be a viable option.Here the role of the primary ion C60+ is assessed with regard to molecular imaging of lipids and pharmaceuticals within tissue sections. High secondary ion yields and low surface damage accumulation are demonstrated on both model and real biological samples, indicating the high secondary ion efficiency afforded to the analyst by this primary ion when compared to other cluster ion beams used in imaging. The newly developed 40 keV C60+ ion source allows the beam to be focused such that high resolution imaging is demonstrated on a tissue sample, and the greater yields allow the molecular signal from the drug raclopride to be imaged within tissue section following in vivo dosing.The localisation shown for this drug alludes to issues regarding the chemical environment affecting the ionisation probability of the molecule; the importance of this effect is demonstrated with model systems and the possibility of using laser post-ionisation as a method for reducing this consequence of bio-sample complexity is demonstrated and discussed.  相似文献   

7.
Imaging mass spectrometry provides both chemical information and the spatial distribution of each analyte detected. Here it is demonstrated how imaging mass spectrometry of tissue at subcellular resolution can be achieved by combining the high spatial resolution of secondary ion mass spectrometry (SIMS) with the sample preparation protocols of matrix-assisted laser desorption/ionization (MALDI). Despite mechanistic differences and sampling 10(5) times less material, matrix-enhanced (ME)-SIMS of tissue samples yields similar results to MALDI (up to m/z 2500), in agreement with previous studies on standard compounds. In this regard ME-SIMS represents an attractive alternative to polyatomic primary ions for increasing the molecular ion yield. ME-SIMS of whole organs and thin sections of the cerebral ganglia of Lymnaea stagnalis demonstrate the advantages of ME-SIMS for chemical imaging mass spectrometry. Subcellular distributions of cellular analytes are clearly obtained, and the matrix provides an in situ height map of the tissue, allowing the user to identify rapidly regions prone to topographical artifacts and to deconvolute topographical losses in mass resolution and signal-to-noise ratio.  相似文献   

8.
In the secondary ion mass spectrometry (SIMS) of organic substances, the molecular weight of the intact ions currently detectable is at best only as high as 1000 Da, which for all practical purposes prevents the technique from being applied to biomaterials of higher mass. We have developed SIMS instrumentation in which the primary ions were argon cluster ions having a kinetic energy per atom, controlled down to 1 eV. On applying this instrumentation to several peptides and proteins, the signal intensity of fragment ions was decreased by a factor of 102 when the kinetic energy per atom was decreased below 5 eV; moreover, intact ions of insulin (molecular weight (MW): 5808) and cytochrome C (MW: 12 327) were detected without using any matrix. These results indicate that fragmentation can be substantially suppressed without sacrificing the sputter yield of intact ions when the kinetic energy per atom is decreased to the level of the target's dissociation energy. This principle is fully applicable to other biomolecules, and it can thus be expected to contribute to applications of SIMS to biomaterials in the future. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Sputtering of solid surfaces by using a focused ion beam is the basis for secondary ion mass spectrometry (SIMS) and sputtered neutral mass spectrometry (SNMS). The ion bombardment initiates not only redistribution of sample atoms but also massive changes in the surface and near surface composition of the bombarded area due to the sputter process and implantation of the primary ions. Changes in the matrix-composition affects the secondary ion yields and therefore a steady state (sputter equilibrium) has to be reached before SIMS data can give quantifiable results. SNMS is much less affected by those yield effects and therefore a combination of SIMS and SNMS can establish a basis for interpretation of SIMS data before the steady state is reached. In order to determine the effects of primary ion incorporation, we applied different primary ion species successively to generate different equilibria. An oxygen ion beam oxidizes the sample surface and by using a rare gas primary ion (PI) this oxide can be removed and analyzed.  相似文献   

10.
We demonstrate depth profiling of polymer materials by using large argon (Ar) cluster ion beams. In general, depth profiling with secondary ion mass spectrometry (SIMS) presents serious problems in organic materials, because the primary keV atomic ion beams often damage them and the molecular ion yields decrease with increasing incident ion fluence. Recently, we have found reduced damage of organic materials during sputtering with large gas cluster ions, and reported on the unique secondary ion emission of organic materials. Secondary ions from the polymer films were measured with a linear type time‐of‐flight (TOF) technique; the films were also etched with large Ar cluster ion beams. The mean cluster size of the primary ion beams was Ar700 and incident energy was 5.5 keV. Although the primary ion fluence exceeded the static SIMS limit, the molecular ion intensities from the polymer films remained constant, indicating that irradiation with large Ar cluster ion beams rarely leads to damage accumulation on the surface of the films, and this characteristic is excellently suitable for SIMS depth profiling of organic materials. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
Static secondary ion mass spectrometry (S-SIMS) is one of the potentially most powerful and versatile tools for the analysis of surface components at the monolayer level. Current improvements in detection limit (LOD) and molecular specificity rely on the optimisation of the desorption-ionisation (DI) process. As an alternative to monoatomic projectiles, polyatomic primary ion (P.I.) bombardment increases ion yields non-linearly. Common P.I. sources are Ga+ (liquid metal ion gun (LMIG), SF5+ (electron ionisation) and the newer Au(n)+, Bi(n)q+ (both LMIG) and C60+ (electron ionisation) sources. In this study the ion yield improvement obtained by using the newly developed ion sources is assessed. Two dyes (zwitterionic and/or thermolabile polar functionalities on a largely conjugated backbone) were analysed as a thin layer using Ga+, SF5+, C60+, Bi+, Bi3(2+) and Bi5(2+) projectiles under static conditions. The study aims at evaluating the improvement in LOD, useful and characteristic yield and molecular specificity. The corrected total ion count values for the different P.I. sources are compared for different instruments to obtain a rough estimate of the improvements. Furthermore, tentative ionisation and fragmentation schemes are provided to describe the generation of radical and adduct ions. Characteristic ion yields are discussed for the different P.I. sources. An overview of the general appearances of the mass spectra obtained with the different P.I. sources is given to stress the major improvement provided by polyatomic P.I.s in yielding information at higher m/z values.  相似文献   

12.
Secondary ion mass spectrometry (SIMS) for biomolecular analysis is greatly enhanced by the instrumental combination of orthogonal extraction time-of-flight mass spectrometry with massive gold cluster primary ion bombardment. Precursor peptide molecular ion yield enhancements of 1000, and signal-to-noise improvements of up to 20, were measured by comparing SIMS spectra obtained using Au(+) and massive Au(400) (4+) cluster primary ion bombardment of neat films of the neuropeptide fragment dynorphin 1-7. Remarkably low damage cross-sections were also measured from dynorphin 1-7 and gramicidin S during prolonged bombardment with 40 keV Au(400) (4+). For gramicidin S, the molecular ion yield increases slightly as a function of Au(400) (4+) beam fluence up to at least 2 x 10(13) Au(400) (4+)/cm(2). This is in marked contrast to the rapid decrease observed when bombarding with ions such as Au(5) (+) and Au(9) (+). When gramicidin S is impinged with Au(5) (+), the molecular ion yield decreases by a factor of 10 after a fluence of only 8 x 10(12) ions/cm(2). Comparison of these damage cross-sections implies that minimal surface damage occurs during prolonged Au(400) (4+) bombardment. Several practical analytical implications are drawn from these observations.  相似文献   

13.
A study of phenylalanine films of different thicknesses from submonolayer to 55 nm on Si wafers has been made using Bin+ and C60+ cluster primary ions in static SIMS. This shows that the effect of film thickness on ion yield is very similar for all primary ions, with an enhanced molecular yield at approximately 1 monolayer attributed to substrate backscattering. The static SIMS ion yields of phenylalanine at different thicknesses are, in principle, the equivalent of a static SIMS depth profile, without the complication of ion beam damage and roughness resulting from sputtering to the relevant thickness. Analyzing thin films of phenylalanine of different thicknesses allows an interpretation of molecular bonding to, and orientation on, the silicon substrate that is confirmed by XPS. The large crater size for cluster ions has interesting effects on the secondary ion intensities of both the overlayer and the substrate for monolayer and submonolayer quantities. This study expands the capability of SIMS for identification of the chemical structure of molecules at surfaces. © Crown copyright 2010.  相似文献   

14.
The capability of secondary ion mass spectrometry (SIMS) to perform atomic and molecular in‐depth analysis in complex nanometric‐metallized thin polymer films used to manufacture capacitors is demonstrated through three different case studies related to failure analysis. The excellent repeatability and sensitivity of the technique allow us to study the degradation process of the nanometric‐metallized layer in the capacitor films and the accurate location of the metal‐polymer interface. The analysis of the sample is challenging due to the extreme difference in conductivity between layers, and the reduced thickness of the metallization grown on top of a rough polymeric base. However, SIMS has provided reliable and reproducible results with relative standard deviation (RSD) values better than 1.5% in the metallic layer thickness estimation. The detailed information of atomic and molecular ion in‐depth distributions provided by SIMS depth profiling has allowed the identification of different factors (demetallization, generation of interstitial oxide regions, and diffusion processes or modification in the metallization thickness) that can be directly related to the origin of the lack of performance of the mounted devices. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
With the implementation of focused primary ion beams, secondary ion mass spectrometry (SIMS) has become a significant technique in the rapidly emerging field of mass spectral imaging in the biological sciences. Liquid metal ion guns (LMIG) offered the prospect of sub-100 nm spatial resolution, however this aspiration has yet to be reached for molecular imaging. This brief review shows that using LMIG the limitations of the static limit and low ionization probability will restrict useful imaging to around 2 μm spatial resolution with high-yield molecules. The only prospect of going beyond this in the absence of factors of 100 increase in ionization probability is to use polyatomic ion beams such as C60+, for which bombardment induced damage is low. In these cases sub-micron imaging becomes possible, using voxels together with molecular depth profiling and 3D imaging. The discussion shows that conventional ToF-SIMS instrumentation then becomes a limitation in that the pulsed ion beam has a very low duty cycle which results in inordinately long analysis times, and pulsing the beam means that high-mass resolution and high spatial resolution are mutually incompatible. New instrumental configurations are described that allow the use of a dc ion beam and separate the mass spectrometry for the ion formation process. Early results from these instruments suggest that sub-micron analysis and imaging with high mass resolution and good ion yields are now realizable, although the low ion yield issue still needs to be solved.  相似文献   

16.
17.
This report provides detailed experimental results of thermal and surface characterization on untreated and surface‐treated halloysite nanotubes (HNTs) obtained from two geographic areas. Surface characterization techniques, including XPS and time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) were used. ToF‐SIMS surface analysis experiments were performed with both atomic and cluster ion beams. Higher ion yields and more high‐mass ions were obtained with the cluster ion beams. Static ToF‐SIMS spectra were analyzed with principal component analysis (PCA). Morphological diversities were observed in the samples although they mainly contained tubular structures. Thermogravimetric data indicated that aqueous hydrogen peroxide solution could remove inorganic salt impurities, such as alkali metal salts. The amount of grafting of benzalkonium chloride of HNT surface was determined by thermogravimetic analysis. PCA of ToF‐SIMS spectra could distinguish the samples mined from different geographical locations as well as among surface‐treated and untreated samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
For more than three decades, time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) has been used for elemental depth profiling. In recent years, cluster primary ion sources (principally, C60+, Bin+, and Aun+) have become widely available, and they can greatly enhance the signal intensity of molecular ions (10–1000 times). Understanding the performance of cluster ion analysis beams used in elemental depth profiling can greatly assist normal ToF‐SIMS users in choosing the optimal analysis beam for depth profiling work. Presently, however, the experimental data are lacking, and such choices are difficult to make. In this paper, hydrogen and deuterium depth profiling were studied using six different analysis beams—25 keV Bi+, Bi3+, Bi5+, 50 keV Bi32+, 10 keV C60+, and 20 keV C602+. The effort shows that cluster primary ions do enhance H? and D? yields, but the enhancement is only about 1.5–4.0 times when compared to atomic Bi+ ions. Because the currents of atomic ion analysis beams are much stronger than the currents of cluster ion analysis beams for most commercial ToF‐SIMS instruments, the atomic ion analysis beams can provide the strongest H? and D? signal intensities, and may be the best choices for hydrogen and deuterium depth profiling. In addition, two representative nuclides, 30Si and 18O, were also studied and yielded results similar to those of H? and D?. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
Polyatomic primary ions have been applied recently to the depth profiling of organic materials by secondary ion mass spectrometry (SIMS). Polyatomic primary ions offer low penetration depth and high damage removal rates in some polymers, but the relationship between polymer chemistry and degradation under polyatomic primary ion bombardment has not been studied systematically. In this study, positive and negative ion time‐of‐flight SIMS (ToF‐SIMS) was used to measure the damage of ~100 nm thick spin‐cast poly(methyl methacrylate) (PMMA), poly(methyl acrylate) (PMA) and poly(methacrylic acid) (PMAA), films under extended (~2 × 1014 ions cm?2) 5 keV SF5+ bombardment. These polymers were compared to determine the effect of the main chain and pendant methyl groups on their degradation under SF5+ bombardment. The sputter rate of PMMA was approximately twice that of PMA or PMAA and the rate of damage accumulation was higher for PMA and PMAA than PMMA, suggesting that the main chain and pendant methyl groups played an important role in the degradation of these polymers under SF5+ bombardment. These results are consistent with the literature on the thermal and radiation‐induced degradation of these polymers, which show that removal of the main chain or pendant methyl groups reduces the rate of depolymerization and increases the rate of intra‐ or intermolecular cross‐linking. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号