共查询到20条相似文献,搜索用时 0 毫秒
1.
E. P. Medyantseva R. M. Varlamova D. A. Gimaletdinova A. N. Fattakhova G. K. Budnikov 《Journal of Analytical Chemistry》2008,63(3):275-279
An amperometric biosensor based on a platinum screen-printed electrode and immobilized monoamine oxidase is developed to determine antidepressants of different classes. Petylyl, pyrazidol, and flu-oxetine can be determined with determination limits of 8 × 10?9, 8 × 10?7, and 8 × 10?10 M, respectively. A procedure is proposed for determining fluoxetine in tablets. It is shown that petylyl can be selectively determined by an immunochemical technique using the developed biosensor and immobilized antibodies in the concentration range from 1 × 10?4 to 1 × 10?8 M. 相似文献
2.
Poly(ethylene glycol)-modified glucose oxidase was immobilized in a poly(vinyl alcohol) cryogel membrane, obtained by a freezing-thawing cyclic process, to obtain a suitable amperometric glucose sensor. The covalent linkage between PEG and GOD molecule improved the physical immobilization of enzyme in the polymeric matrix, by decreasing its loss in time. Sensor behaviour was evaluated electrochemically with a hydrogen peroxide electrode. The glucose content in standard solutions was determined and linear calibration curves in the 5x10(-5)-5x10(-3) mol l(-1) range were obtained. The kinetic parameters in the immobilized system were evaluated and analytical characteristics of sensor, including stability and influence of pH and temperature, were determined. 相似文献
3.
Tyrosinase from a plant source Amorphophallus companulatus was immobilized on eggshell membrane using glutaraldehyde. Among the three different approaches used for immobilization, activation of eggshell membrane by glutaraldehyde followed by enzyme adsorption on activated support could stabilize the enzyme tyrosinase and was found to be effective. Km and Vmax values for dopamine hydrochloride calculated from Lineweaver-Burk plot were 0.67 mM and 0.08 mM min−1, respectively. Studies on effect of pH showed retention of more than 90% activity over a pH range 5.0-6.5. Membrane bound enzyme exhibited consistent activity in the temperature range 20-45 °C. Shelf life of immobilized tyrosinase system was found to be more than 6 months when stored in phosphate buffer at 4 °C. An electrochemical biosensor for dopamine was developed by mounting the tyrosinase immobilized eggshell membrane on the surface of glassy carbon electrode. Dopamine concentrations were determined by the direct reduction of biocatalytically liberated quinone species at −0.19 V versus Ag/AgCl (3 M KCl). Linearity was observed within the range of 50-250 μM with a detection limit of 25 μM. 相似文献
4.
Biosensors for determination of glucose with glucose oxidase immobilized on an eggshell membrane 总被引:1,自引:0,他引:1
A glucose biosensor using an enzyme-immobilized eggshell membrane and oxygen electrode for glucose determination has been fabricated. Glucose oxidase was covalently immobilized on an eggshell membrane with glutaraldehyde as a cross-linking agent. The glucose biosensor was fabricated by positioning the enzyme-immobilized eggshell membrane on the surface of a dissolved oxygen sensor. The detection scheme was based on the depletion of dissolved oxygen content upon exposure to glucose solution and the decrease in the oxygen level was monitored and related to the glucose concentration. The effect of glutaraldehyde concentration, pH, phosphate buffer concentration and temperature on the response of the glucose biosensor has been studied in detail. Common matrix interferents such as ethanol, d-fructose, citric acid, sodium benzoate, sucrose and l-ascorbic acid did not give significant interference. The resulting sensor exhibited a fast response (100 s), high sensitivity (8.3409 mg L−1 oxygen depletion/mmol L−1 glucose) and good storage stability (85.2% of its initial sensitivity after 4 months). The linear response is 1.0×10−5 to 1.3×10−3 mol L−1 glucose. The glucose content in real samples such as commercial glucose injection preparations and wines was determined, and the results were comparable to the values obtained from a commercial glucose assay kit based on a spectrophotometric method. 相似文献
5.
Cholesterol oxidase (ChOx) and cholesterol esterase (ChEt) have been covalently immobilized onto tetraethylorthosilicate (TEOS) sol-gel films. The tetraethylorthosilicate sol-gel/ChEt/ChOx enzyme films thus prepared have been characterized using scanning electron microscopic (SEM), UV-vis spectroscopic, Fourier-transform-infrared (FTIR) spectroscopic and amperometric techniques, respectively. The results of photometric measurements carried out on tetraethylorthosilicate sol-gel/ChEt/ChOx reveal thermal stability up to 55 °C, response time as 180 s, linearity up to 780 mg dL−1 (12 mM), shelf life of 1 month, detection limit of 12 mg dL−1 and sensitivity as 5.4 × 10−5 Abs. mg−1 dL−1. 相似文献
6.
7.
《Journal of membrane science》1997,127(1):1-7
Radiation induced grafting of acrylic acid (AA) onto 40 μm polytetrafluoroethylene (PTFE) films was carried out by the direct method of multiple (discrete) and single irradiation form 60Co source at different doses up to 100 kGy and room temperature. Depending on the method, the grafting takes place either on the surface layer or within the polymer matrix. The graft copolymers synthesized (PTFE-g-PAA) were transformed into ionomers by treatment with KOH. Both forms were used as carriers for immobilization of enzymes. The copolymers in H- and K-forms were activated by the acylazide method and glucose oxidase (GOD) was immobilized on them. The most suitable proved to be the ionomers PTEE-g-COOK obtained by single irradiation, possessing activity of ca. 120 mU/cm2. Enzyme biosensor was designed based on Clark-type electrode and the active membranes prepared, where the membrane plays both the roles of enzyme and oxygen membrane. It can be used for determination of glucose in solutions. 相似文献
8.
Ana Calvo-Pérez Olga Domínguez-Renedo María Asunción Alonso-Lomillo María Julia Arcos-Martínez 《Mikrochimica acta》2013,180(3-4):253-259
We have developed screen–printed carbon electrodes for the determination of tyramine (Tyr) via plasma amine oxidase. The enzyme was immobilized on the carbon working electrode by cross–linking it with bovine serum albumin using glutaraldehyde. The employment of the mediator hydroxymethylferrocene lowers the working potential to +260 mV (vs. a screen–printed Ag/AgCl reference electrode). The effects of pH, potential and mediator concentration were optimized and resulted in reproducibility and repeatability values of 8.6 % and 8.7 %, respectively. Response is linear in the range from 2 to 164 μM, and the limit of detection is 2.0?±?0.18 μM. The effects of potentially interfering biogenic amines such as putrescine, cadaverine, histamine, spermine, spermidine and tryptamine were also evaluated. The biosensor was successfully applied to the determination of Tyr in cheese. Figure
Amperometric determination of tyramine using a biosensor based on the immobilization of polyamine oxidase (PAO) enzyme on a disposable screen-printed carbon electrode. 相似文献
9.
A simple method is described to determine sulfite in beer samples using a fill and flow channel biosensor. A droplet of sample is placed into the inlet of a rectangular flow cell and begins to flow through the channel by capillarity. The flow is maintained and controlled by a porous outlet plug of defined porosity. In a rectangular flow cell, the sample solution flows through three consecutive zones: over a predictor electrode, an enzyme layer and a detector electrode. Together these three zones enable the differentiation between current due to sulfite and current due to other electroactive species in the sample. The predictor electrode is located upstream, and on the opposite channel wall to the enzyme layer and detector electrode, and is poised at the same potential (+0.65 V versus Ag/AgCl) as the detector electrode. On this electrode, the current contribution from all species in the sample solution that are oxidized at that potential is determined. The enzyme layer contains sulfite oxidase, which, in the process of oxidizing sulfite, produces hydrogen peroxide, which itself is reduced by excess sulfite. The current at the downstream detector electrode is therefore different from that at the predictor electrode as a result of the enzyme reaction and the difference of the currents, corrected for the dimensions of the electrodes, is proportional to the concentration of sulfite. The method enables a straightforward correction of the interfering current at the detector electrode and a determination of the analyte concentration. The effect of interferences from ascorbic acid, ethanol, sorbic acid and tartaric acid in the detection of sulfite is efficiently removed. The concentration of sulfite in a sample of beer measured by the biosensor is equivalent to that measured using a reference method based on the AOAC-recommended Monier-Williams method. 相似文献
10.
Bhawna Batra Suman Lata Rooma Devi Sandeep Yadav Chandra Shekhar Pundir 《Journal of Solid State Electrochemistry》2012,16(12):3869-3876
An amperometric tyramine biosensor was constructed based on covalent immobilization of black gram tyramine oxidase onto citric acid-capped silver nanoparticles bound to surface of Au electrode through cysteine self-assembled monolayer. The enzyme electrode was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and cyclic voltametry. The biosensor showed optimum response within 8 s, when polarized at 0.25 V, pH 8.5, and 35 °C, with linearity from 0.017 to 0.25 mM and a detection limit of 0.01 mM. The biosensor was employed for measurement of tyramine in beer and sauce. The mean analytical recovery of added tyramine in beer at 0.36 and 0.72 mM were 97.2?±?2.7 and 95.8?±?4.1 %, respectively, and within and between batches coefficients of variation were 0.33–0.38 and 0.34–0.62 %, respectively. The enzyme electrode lost 35 % of its initial activity after its 100 uses, over a period of 2 months, when stored at 4 °C. 相似文献
11.
《Electrochemistry communications》2007,9(3):454-458
Xathine oxidase was chemically modified with β-cyclodextrin-branched carboxymethylcellulose and further supramolecularly immobilized on a gold electrode, previously coated with a monolayer of 1-adamantanyl residues. The electrode was employed for constructing an amperometric biosensor device, which showed linear response (poised at +700 mV vs. Ag/AgCl) toward xanthine concentration between 300 μM and 10.4 mM at pH 7.0. The biosensor reached 95% of steady-state current in about 14 s and its sensitivity was 8.2 mA/M cm2. The enzyme electrode retained 93% of its initial activity after 3 weeks of storage at 4 °C in 50 mM sodium phosphate buffer, pH 7.0. The supramolecular nature of the immobilization approach was confirmed by cyclic voltammetry. 相似文献
12.
M. Alves Da Silva M. Helena Gil J. S. Redinha Ana M. Oliveira Brett J. L. Costa Pereira 《Journal of polymer science. Part A, Polymer chemistry》1991,29(2):275-279
The immobilization of glucose oxidase on hydrolyzed nylon-6,6 was studied. Various spacers were introduced on the support before the coupling of the enzyme. Best results were obtained when the membrane was covered with denatured bovine serum albumin (BSA) before spacer coupling and immobilization of glucose oxidase (GOD). The influence of various factors (pH, ionic strength, etc.) on the activity of the free and immobilized enzyme was investigated. It was found that the behavior of the fixed glucose oxidase and the free enzyme is very similar. The covalently immobilized enzyme had a lifetime of around 2 months (50% of initial activity). 相似文献
13.
Journal of Solid State Electrochemistry - A biosensor for trace mercury ions based on glucose oxidase (GOD) immobilized on liposome microreactor and chitosan (CS) nanocomposite through... 相似文献
14.
In this paper, a polydopamine (PDA) film is electropolymerized on the surface of bilayer lipid membrane (BLM) which is immobilized with horseradish peroxidase (HRP). The coverage of the PDA film on HRP/BLM electrode is monitored by electrochemical impedance spectroscopy (EIS). The electrocatalytic reduction of H2O2 at the PDA/HRP/BLM electrode is studied by means of cyclic voltammetry (CV). The biosensor has a fast response to H2O2 of less than 5 s and an excellent linear relationship is obtained in the concentration range from 2.5 × 10−7 to 3.1 × 10−3 mol L−1, with a detection limit of 1.0 × 10−7 mol L−1 (S/N = 3). The response current of BLM/HRP/PDA biosensor retains 84% of its original response after being stored in 0.1 mol L−1 pH 7.0 PBS at 4 °C for 3 weeks. The selectivity, repeatability, and storage stability of PDA/HRP/BLM biosensor are greatly enhanced by the coverage of polydopamine film on BLM. 相似文献
15.
The use of biotinylated alginate as an immobilization matrix of enzymes on the surface of the amperometric transducer is described herein. The model used is that of the well-established glucose detection. Several types of immobilization protocols were tested. In the exception of one protocol, biotin labeled glucose oxidase was shown to first require conjugation with avidin, before its immobilization onto a biotin-alginate gel matrix. The response of the biosensors to incremental additions of glucose, was measured by potentiostating the modified electrodes at 0.6 V/SCE. The permeability of the modified electrodes was thereafter measured by using rotating disk electrode (RDE) voltammetry with ferrocenemonocarboxylic acid as the electroactive probe. 相似文献
16.
Asha Chaubey Manju Gerard V. S. Singh B. D. Malhotra 《Applied biochemistry and biotechnology》2001,96(1-3):303-311
Tetraethylorthosilicate (TEOS)-derived sol-gel films were utilized for the immobilization of lactate dehydrogenase (LDH) by
physical adsorption and sol-gel/LDH/sol-gel sandwich configuration. An attempt was made to ascertain the optimum pH and temperature
for the immobilized LDH. It was shown that TEOS-derived sol-gel films containing physically adsorbed LDH exhibited linearity
from 0.5 to 4 mM, whereas those containing LDH in sandwich configuration showed linearity from 0.5 to 3 mM
l-lactate. These sol-gel films, immobilized with LDH, were found to be stable for about 4 weeks at 4–10°C. 相似文献
17.
An amperometric glucose biosensor was developed based on the immobilization of glucose oxidase in the organically modified
silicate (ormosil)-polyvinyl acetate (PVA) matrix onto a Prussian Blue (PB)-modified glassy carbon electrode. A higher stability
PB-modified electrode was prepared by the electrochemical deposition of FeCl3, K3[Fe(CN)6] and ethylenediamine tetraacetic acid (EDTA) under cyclic voltammetric (CV) conditions. The effects of the potential range
of CV conditions, electrolyte cations, applied potential, pH, temperature and co-existing substances were investigated. The
detection limit of the glucose biosensor was 8.1 μmol·L−1 (S/N = 3) with a linear range from 20 μmol·L−1 to 2 mmol·L−1 (R = 0.9965). The biosensor presented a fast response and good selectivity. Additionally, excellent reproducibility and stability
of the biosensor were observed.
Supported by the National High Technical Development Project (863 project) Foundation (Grant No. 2006AA09Z160) and the National
Natural Science Foundation of China (Grant No. 20775064) 相似文献
18.
Poly(ethylene glycol) methyl ether methacrylate (PEGMEM) microparticles were synthesized and glucose oxidase (GOx) was immobilized within the microparticles. An amperometric biosensor was fabricated using the microparticles with GOx as biological component. The enzyme immobilization method was optimized by investigating the influence of monomer concentration and cross-linker content used in the preparation of the microparticles in the response of the biosensor. The best analytical results were obtained with the microparticles prepared with 0.21 M PEGMEM and 0.74% cross-linking. Furthermore, we have investigated the influence on the biosensor behaviour of parameters such as working potential, pH, temperature and enzymatic load. In addition, analytical properties such as sensitivity, linear range, response time and detection limit were determined. The biosensor was used to determine glucose in human serum samples and to avoid common interferents present in human serum such as uric and ascorbic acids. A Nafion layer was deposited on the electrode surface with satisfactory results. The useful lifetime of the biosensor was at least 520 days. 相似文献
19.
Lucy Gilbert Simon Browning Andrew T. A. Jenkins John P. Hart 《Mikrochimica acta》2010,170(3-4):331-336
An amperometric biosensor for phosphate ion is described that is based on a cobalt phthalocyanine modified screen-printed carbon electrode (CoPC-SPCE). The biosensor operation is based on the enzyme pyruvate oxidase (PyOd) which catalyses the oxidative decarboxylation of pyruvate, in the presence of inorganic phosphate and O2, to acetyl phosphate, hydrogen peroxide (H2O2) and CO2. The transducer allows the electrocatalytic oxidation of H2O2 in order to generate the analytical signal. The enzyme was immobilised onto the CoPC-SPCE using a sandwich format. The inner membrane was formed in situ by depositing an acetone solution containing cellulose acetate first onto the transducer surface. The enzyme and cofactors were then deposited onto this layer and allowed to dry; finally a second aliquot of the cellulose acetate solution was deposited onto the enzyme layer and allowed to dry. The biosensor was characterised by amperometry in stirred solution to produce current-voltage curves and for calibration studies. From these it was deduced that a reliable electrocatalytic response was obtained for phosphate ion; an operating potential of +0.4 V was selected for the analysis of urine samples. The precision of the response for urine analysis and recovery data for potable water suggests that the biosensor could have applications in clinical and environmental monitoring. 相似文献
20.
Junping Dong Xiaojuan Zhou Hongbin Zhao Jiaqiang Xu Youbao Sun 《Mikrochimica acta》2011,174(3-4):281-288
Ferrocene (Fc) was encapsulated in the cavities of a NaY zeolite by vapor diffusion via sublimation at below 100?°C. The resulting Fc@NaY zeolite composite was investigated by power X-ray diffraction, diffuse reflectance UV?Cvis and FT-IR spectroscopy, and by cyclic voltammetry. The results indicated that Fc was encapsulated into the zeolite whose microporous structure had remained intact. The Fc in the silica matrix had retained its electroactivity and did not leach out. A glucose biosensor was obtained by immobilization of the modified zeolite and glucose oxidase on a carbon paste electrode. It displays a linear response to glucose (from 0.8???M to 4.0?mM), a detection limit of 0.2???M, and a response time of 4?s. The good performance of the biosensor is ascribed to the biocompatibility of the zeolite and presence of Fc which facilitates the electron transfer from the enzyme to the surface of the electrode. Figure
Reagentless glucose biosensor is constructed by immobilization of glucose oxidase on a ferrocene@NaY zeolite composite. The biosensor displays very good responses to the different concentrations of glucose. 相似文献