首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
We previously demonstrated the separation of proteins by isoelectric focusing (IEF) over pH 4-8 immobilized pH gradients (IPGs) over 54 cm (Poland et al., Electrophoresis 2003, 24, 1271). Here we show that similar results can be conveniently achieved using commercially available IPGs of appropriate pH ranges positioned end-on-end in series during electrophoresis, which we term "daisy chain IEF". Proteins efficiently electrophorese from one IPG to another during IEF by traversing buffer-filled porous bridges between the serial IPGs. A variety of materials can function as bridges, including paper, polyacrylamide gels or even IPGs. The quality of two-dimensional (2-D) protein patterns is not apparently worse than that generated by conventional IEF using the same individual IPGs. A major advantage of this method is that sample is consumed efficiently, without the requirement for preliminary steps, such as chamber IEF. This advantage is pronounced when working with extremely limited sources of samples, such as with clinical biopsies or cellular subfractions. The present study was limited by the commercial availability of suitable pH gradients. Proteomics analyses could be further improved if commercial vendors would manufacture IPGs with suitable pH ranges to achieve high resolution (approximately 100 cm) IEF separation of proteins in one electrophoretic step over the pH range 2-12.  相似文献   

2.
Repeatedly usable immobilized pH gradient in a monolithic capillary column   总被引:2,自引:0,他引:2  
Yang C  Zhu G  Zhang L  Zhang W  Zhang Y 《Electrophoresis》2004,25(12):1729-1734
Glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA) were used to synthesize a monolithic capillary column containing reactive epoxy groups. Glutaraldehyde was introduced and linked to the monolith after a process of amination. An aqueous solution of commercial carrier ampholytes (CAs, Ampholine) was focused in such a polymer column. The primary amino groups of CAs reacted with glutaraldehyde along the capillary. CAs were immobilized at different positions in the column according to their isoelectric points (pI), resulting in a monolithic immobilized pH gradient (M-IPG). Isoelectric focusing (IEF) was performed without CAs in such an M-IPG column. Due to the covalent attachment of the CAs this M-IPG can be repeatedly used after its preparation. Good stability, linearity, and reproducibility were obtained.  相似文献   

3.
Wu XZ  Zhang LH  Onoda K 《Electrophoresis》2005,26(3):563-570
Carrier ampholyte-free isoelectric focusing (IEF) sample injection (concentration) for capillary electrophoresis (CE) is realized in a single capillary. A short section of porous capillary wall was made near the injection end of a capillary by HF etching. In the etching process, an electric voltage was applied across the etching capillary wall and electric current was monitored. When an electric current through the etching capillary was observed, the capillary wall became porous. The etched part was fixed in a vial, where NaOH solution with a certain concentration was added during the sample injection. The whole capillary was filled with pH 3.0 running buffer. The inlet end vial was filled with protein sample dissolved in the running buffer. An electric voltage was applied across the inlet end vial and etched porous wall. A neutralization reaction occurs at the boundary (interface) of the fronts of H+ and OH-. A pH step or sharp pH gradient exists across the boundary. When positive protein ions electromigrate to the boundary from the sample vial, they are isoelectricelly focused at points corresponding to their pH. After a certain period of concentration, a high voltage is applied across the whole capillary and a conventional CE is followed. An over 100-fold concentration factor has been easily obtained for three model proteins (bovine serum albumin, lysozyme, ribonuclease A). Furthermore, the IEF sample concentration and its dynamics have been visually observed with the whole-column imaging technique. Its merits and remaining problem have been discussed, too.  相似文献   

4.
Xanthine oxidase (XOD) is a key enzyme in the human body to produce uric acid, and its inhibitor can be used for the treatment of hyperuricemia and gout. In this study, an online CE-based XOD immobilized enzyme microreactor (IMER) was developed for the enzyme kinetics assays and inhibitor screening. After 30 consecutive runs, the XOD activity remained about 95.6% of the initial immobilized activity. The Michaelis–Menten constant (Km) of the immobilized XOD was determined as 0.39 mM using xanthine as substrate. The half-maximal inhibitory concentration and inhibition constant of the known inhibitor 4-aminopyrazolo[3,4-d]pyrimidine on XOD were determined as 11.9 and 5.2 μM, respectively. Then, the developed method was applied to evaluate the XOD inhibitory activity of 10 flavonoids, which indicated that dihydroquercetin, quercetin, biochanin A, and epicatechin had significant inhibitory effect on XOD. In addition, molecular docking results verified that the binding energy of the flavonoids with enzyme were in line with their inhibitory activity determined by XOD–IMER. Therefore, the developed XOD–IMER is a potential tool for the primary screening of XOD inhibitors from natural products.  相似文献   

5.
Membrane proteins were separated by high resolution two-dimensional (2-D) electrophoresis. On isoelectric focusing (IEF) with immobilized pH gradients severe protein losses in the resulting 2-D map were observed when compared with carrier ampholyte-based IEF. This has been noticed for two different biological systems, namely the chloroplast envelope of spinach and the endocytic vesicles from Dictyostelium discoideum. The possible mechanisms of these losses on immobilized pH gradients are discussed.  相似文献   

6.
新型固定化pH梯度毛细管等电聚焦方法用于蛋白分离   总被引:1,自引:0,他引:1  
通过化学键合建立一种固定化pH梯度的方法,用于毛细管等电聚焦分离蛋白质.采用微流控泵驱动毛细管内的聚焦区带,通过调节泵的流量,从而调节聚焦区带的迁移速度.该方法避免了自由溶液聚焦时两性电解质所带来的影响,实现了高灵敏度及检测波长自由选择等优点,适用于两步法毛细管电泳等电聚焦分离蛋白质等两性电解质.本文考察了对牛血清白蛋白和血红蛋白两种蛋白质混合物的分离,证明了该方法可行.  相似文献   

7.
In an attempt to prepare quasi-isoelectric buffers as BGEs for CE, carrier ampholytes (CAs) (Ampholine, pH 7-9; Servalyt, pH 7-9; Bio-Lyte, pH 8-10 and Pharmalyte, pH 8-10.5) have been subdivided with the Rotofor into 20 fractions, of ca. 0.1 pH unit span, whose composition has been studied by CZE-MS. The results have allowed identifying the number of different molecular mass compounds present in every commercial brand, as well as the number of isoforms (having identical mass, but representing positional isomers) associated with a given M(r) value. Ampholine is composed of 29 species, for a total of 85 different isoforms; Bio-Lyte is made of 43 compounds, for a total of 136 isoforms; Pharmalyte comprises 58 different M(r) chemicals, for a total of 102 isoforms and Servalyt is constituted by 65 species, for a total of 306 compounds (all of these values to be considered as minimum numbers, as detected by the present methodology). Surprisingly, and contrary to theory, a very large proportion (up to 70%) of these species are 'poor carrier ampholytes', in that they are unable to focus and are evenly distributed along the generated pH gradient in the electric field. Paradoxically, the pH gradient is created and sustained by the minority of species (30% for three brands, up to 50% for Pharmalyte) that appear to focus at their pI position into reasonably sharp zones. Even in the narrowest pI fraction, up to 20 different compounds can be detected. It is concluded that very few amines with different useful pK values are utilized for the synthesis and that a new generation of CAs with a more diversified population of amines with proper pK values within the given pH intervals should be sought. Ampholine, the poorest of the commercial brands, appears to be still made with the original synthesis devised by Vesterberg, i.e. by reacting a concoction of oligoamines with alpha,beta-unsaturated acids.  相似文献   

8.
The four classical modes of electrophoresis of protein molecules (sodium dodecyl sulphate electrophoresis, SDS-PAGE, isoelectric focusing, IEF, and immobilized pH gradients, IPGs, two-dimensional maps, 2D, and capillary electrophoresis, CE) are here reviewed, with special emphasis on recent innovations. Thus, in the case of SDS-PAGE, a novel method, consisting in focusing SDS-protein micelles against a gradient of cationic charges grafted onto a polyacrylamide gel is presented. In the case of IEF, the recent decoding of the structure, polydispersity, molecular mass distribution and buffering properties of the soluble carrier ampholyte buffers are here discussed. In regard to two dimensional mapping, recent instrumentation for performing 2D maps in horizontal, large gel slabs (up to 30 cm × 40 cm) and in a radial format for the SDS dimension is here evaluated. Finally, in the case of CE, three major applications are presented: a thorough study of capillary IEF and of all experimental variables, a method of importance in screening of rDNA products; the possibility of running proteins and peptide separations in very acidic, amphoteric, isoelectric buffers in absence of any capillary coating; finally, the possibility of producing a facile, user friendly, covalent coating of the wall silanols via bonding of quaternarized piperazines endowed with an iodinated tail. In acidic, volatile buffers, such protein/peptide runs can be directly interfaced with mass spectrometry instrumentation.  相似文献   

9.
Yang L  Chen C  Chen Y  Shi J  Liu S  Guo L  Xu H 《Analytica chimica acta》2010,683(1):136-142
A novel method for monitoring of enzyme reaction and inhibition with high temporal resolution was developed by using optically gated vacancy capillary electrophoresis (OGVCE) with laser-induced fluorescence (LIF) detection and immobilized enzyme. Trypsin cleavage reaction and inhibition were investigated by the presented OGVCE-LIF assay, using carboxyfluorescein (FAM) end-labeled Angiotensin as the substrate and commercially available immobilized trypsin. The substrate and the product were continuously loaded into the capillary by the electroosmotic flow while the immobilized enzyme remained in the sample vial. Substrate consumption and product formation were monitored simultaneously at 5 s interval during the whole reaction time. The enzymatic reaction rates obtained from the substrate and the product were highly consistent. The enzyme activity and the Michaelis constants of trypsin cleavage reaction, as well as the inhibition constant (for reversible competitive inhibitor) and the inhibition fraction (for irreversible inhibitor), were obtained. It was showed that the reported OGVCE-LIF method can perform fast, accurate, sensitive and reproducible CE enzyme assay with high temporal resolution, thus has great potential in application of the enzyme-substrate systems with fast reaction rate and the fluorescent substrate and products.  相似文献   

10.
This review article describes the significant recent developments in analysis of proteins by capillary electromigration (CE) methods (zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography and electrochromatography) during the period 2011–2015. Improvements in sample preparation, preconcentration, suppression of adsorption and control of electroosmotic flow, separations by particular CE methods, and the detection schemes used in the analysis of proteins are discussed. Innovative applications of the above CE methods for quality control of protein biopharmaceuticals, protein determination in complex biomatrices, peptide mapping of proteins, and determination of physicochemical parameters of proteins are presented.  相似文献   

11.
Recently the use electric field gradient focusing (EFGF) to enhance focusing of proteins has been proposed and explored to provide significant improvement in separation resolution. The objective of EFGF is to focus proteins of specific electrophoretic mobilities at distinct stationary locations in a column or channel. This can be accomplished in a capillary by allowing the electric potential to vary in the streamwise direction. Because the electric field is varying, so also is the electrokinetic force exerted on the proteins and the electroosmotic velocity of the buffer solution. Due to the varying electric field, the Taylor diffusion characteristics will also vary along the column, causing a degradation of peak widths of some proteins, dependent on their equilibrium positions and local velocity distributions. The focus of this paper is an analysis that allows characterization of the local Taylor diffusion and resulting protein band peak width as a function of the local magnitude of the EOF relative to the average fluid velocity for both cylindrical and rectangular channels. In general the analysis shows that as the ratio of the local electroosmotic velocity to the average velocity deviates from unity, the effective diffusion increases significantly. The effectiveness of EFGF devices over a range of protein diffusivities, capillary diameters, flow velocities, and electric field gradient is discussed.  相似文献   

12.
《Electrophoresis》2017,38(3-4):486-493
A new method for screening tyrosinase inhibitors from traditional Chinese medicines (TCMs) was successfully developed by capillary electrophoresis with reliable online immobilized enzyme microreactor (IMER). In addition, molecular docking study has been used for supporting inhibition interaction between enzyme and inhibitors. The IMER of tyrosinase was constructed at the outlet of the capillary by using glutaraldehyde as cross‐linker. The parameters including enzyme reaction, separation of the substrate and product, and the performance of immobilized tyrosinase were investigated systematically. Because of using short‐end injection procedure, the product and substrate were effectively separated within 2 min. The immobilized tyrosinase could remain 80% active for 30 days at 4°C. The Michaelis–Menten constant of tyrosinase was determined as 1.78 mM. Kojic acid, a known tyrosinase inhibitor, was used as a model compound for the validation of the inhibitors screening method. The half‐maximal inhibitory concentration of kojic acid was 5.55 μM. The method was successfully applied for screening tyrosinase inhibitors from 15 compounds of TCM. Four compounds including quercetin, kaempferol, bavachinin, and bakuchiol were found having inhibitory potentials. The results obtained in this work were supported by molecular docking study.  相似文献   

13.
Current algorithms for the calculation of peptide or protein pI, based on the charge associated with individual amino acids, can calculate pI values to within +/-0.2 pI units. Here, we present a new pI calculation algorithm that takes into account the effect of adjacent amino acids on the pI value. The algorithm accounts for the effect of adjacent amino acids+/-3 residues away from a charged aspartic or glutamic acid, as well as effects on the free C terminus, and applies a correction term to the corresponding pK values. The correction increments are derived from a 5000-peptide training set using a genetic optimization approach. The accuracy of the new pI values obtained with this method approaches the error associated with the manufacture of the IPG strip (<+/-0.03 pI units). The approach is demonstrated for cytosolic cell extracts derived from the breast-cancer cell line DU4475, and from membrane preparations from human lung-tissue samples. One potential application of a more highly accurate pI calculation is data filtering of MS/MS outputs that will allow for more complex database searches including gene finding, and validation, and detection of coding single-nucleotide polymorphisms in their expressed form.  相似文献   

14.
We report the first application of hydrophobic interaction between graphene oxide (GO) and negatively charged enzymes to fabricate CE-integrated immobilized enzyme microreactors (IMERs) by a simple and reliable immobilization procedure based on layer by layer assembly. L -lactate dehydrogenase (L -LDH), which is negatively charged during the enzymatic reaction, is selected as the model enzyme. Various spectroscopic techniques, including SEM, FTIR, and UV-vis are used to characterize the fabricated CE-IMERs, demonstrating the successful immobilization of enzymes on the negatively charged GO layer in the capillary surface. The IMER exhibits excellent repeatability with RSDs of inter-day and batch-to-batch less than 3.49 and 6.37%, respectively, and the activity of immobilized enzymes remains about 90% after five-day usage. The measured Km values of pyruvate and NADH of the immobilized L -LDH are in good agreement with those obtained by free enzymes. The results demonstrate that the hydrophobic interactions and/or π-π stacking is significant between the GO backbone and the aromatic residues of L -LDH and favorable to fabrication of CE-integrated IMERs. Finally, the method is successfully applied to the determination of pyruvate in beer samples.  相似文献   

15.
In this work, we demonstrate the potential use of immobilized pH gradient isoelectric focusing as a first dimension in shotgun proteomics. The high resolving power and resulting reduction in matrix ionization effects due to analyzing peptides with almost the exact same physiochemical properties, represents a significant improvement in performance over traditional strong cation-exchange first-dimensional analysis associated with the shotgun proteomics approach. For example, using this technology, we were able to identify more than 6000 peptides and > 1200 proteins from the cytosolic fraction of Escherichia coli from approximately 10 microg of material analyzed in the second-dimensional liquid chromatography-tandem mass spectrometry experiment. Sample loads on the order of 1 mg can be resolved to 0.25 isoelectric point (pI) units, which make it possible to analyze organisms with significantly larger genomes/proteomes. Accurate pI prediction can then be employed using currently available algorithms to very effectively filter data for peptide/protein identification, and thus lowering the false-positive rate for cross-correlation-based peptide identification algorithms. By simplifying the protein mixture problem to tryptic peptides, the effect of specific amino acids on pI prediction can be evaluated as a function of their position in the peptide chain.  相似文献   

16.
In this work, the development of a packed immobilized enzyme reactor (IMER) and its integration to a capillary electrophoresis microchip is described. The present microchip design differs from others, in the fact that the same design could be used with or without the particles and, just by changing the material used to pack the IMER, different analytes can be detected. The applied procedure involves the separation of the target analyte by capillary electrophoresis (CE), which is then coupled to a post‐column IMER that produces H2O2. The H2O2 produced is finally detected downstream at the surface of a working electrode. Glucose was detected above 100 μM by packing particles modified with glucose oxidase at the end of the separation channel. The analytical performance of the microchip‐CE has been demonstrated by performing the separation and detection of glucose and noradrenaline. Additions of fructose showed no effect on either the peak position or the peak magnitude of glucose. The microchip‐CE‐IMER was also used to quantify glucose in carbonated beverages with good agreement with other reports.  相似文献   

17.
An integrated platform consisting of protein separation by CIEF with monolithic immobilized pH gradient (M‐IPG), on‐line digestion by trypsin‐based immobilized enzyme microreactor (trypsin‐IMER), and peptide separation by CZE was established. In such a platform, a tee unit was used not only to connect M‐IPG CIEF column and trypsin‐IMER, but also to supply adjustment buffer to improve the compatibility of protein separation and digestion. Another interface was made by a Teflon tube with a nick to couple IMER and CZE via a short capillary, which was immerged in a centrifuge tube filled with 20 mmol/L glutamic acid, to exchange protein digests buffer and keep electric contact for peptide separation. By such a platform, under the optimal conditions, a mixture of ribonuclease A, myoglobin and BSA was separated into 12 fractions by M‐IPG CIEF, followed by on‐line digestion by trypsin‐IMER and peptide separation by CZE. Many peaks of tryptic peptides, corresponding to different proteins, were observed with high UV signals, indicating the excellent performance of such an integrated system. We hope that the CE‐based on‐line platform developed herein would provide another powerful alternative for an integrated analysis of proteins.  相似文献   

18.
Zhang P  Gao M  Zhu S  Lei J  Zhang X 《Journal of chromatography. A》2011,1218(47):8567-8571
In this report, laser radiation (808nm) for the first time was employed to enhance the efficiency of proteolysis through immobilized enzyme reactor (IMER). IMER based monolithic support was prepared in the fused-silica capillary via a simple two-step procedure including acryloylation on trypsin surface and in situ aqueous polymerization/immobilization. The feasibility and high efficiency of the laser-assisted IMER were demonstrated by the digestion of bovine serum albumin (BSA), cytochrome c (Cyt-c) and β-casein. The digestion process was achieved in 60s. The peptides were identified by MALDI-TOF-MS, yielding the sequence coverage of 33% for BSA, 73% for Cyt-c and 22% for β-casein. The comparisons between the in-solution digestion and on IMER reaction with/without laser assistance were made. To further confirm its efficiency in proteome analysis, the laser-assisted IMER was also applied to the analysis of one fraction of human serum sample through two-dimensional (2-D) separation of strong anion exchange/reversed-phase liquid chromatography (SAX/RPLC). After a database search, 49 unique peptides corresponding to 5 proteins were identified. The results showed that the laser-assisted IMER provides a promising platform for the high-throughput protein identification.  相似文献   

19.
将氨基酰化酶通过戊二醛固定在毛细管内壁,制备毛细管酶微反应器,用毛细管区带电泳对毛细管酶微反应器的酶解产物进行分离,以生成物的峰面积优化底物N-乙酰-DL-蛋氨酸的酶解条件。实验结果表明,在温度37℃的条件下,10μg/mL N-乙酰-DL-蛋氨酸磷酸盐缓冲溶液(pH7.5)以4μL/min的速度通过15 cm长的毛细管酶微反应器,具有良好的酶解效果。利用毛细管酶微反应器对底物N-乙酰-DL-蛋氨酸进行酶解,每天酶解5次,10天后酶活仅下降了8.66%,说明制备的毛细管酶微反应器具有良好的稳定性。  相似文献   

20.
Our group recently reported on the application of protein-doped monolithic silica columns for immobilized enzyme reactor chromatography, which allowed screening of enzyme inhibitors present in mixtures using mass spectrometry for detection. The enzyme was immobilized by entrapment within a bimodal meso/macroporous silica material prepared by a biocompatible sol-gel processing route. While such columns proved to be useful for applications such as screening of protein-ligand interactions, significant amounts of entrapped proteins leached from the columns owing to the high proportion of macropores within the materials. Herein, we describe a detailed study of factors affecting the morphology of protein-doped bioaffinity columns and demonstrate that specific pH values and concentrations of poly(ethylene glycol) can be used to prepare essentially mesoporous columns that retain over 80% of initially loaded enzyme in an active and accessible form and yet still retain sufficient porosity to allow pressure-driven flow in the low μL/min range. Using the enzyme γ-glutamyl transpeptidase (γ-GT), we further evaluated the catalytic constants of the enzyme entrapped in capillary columns with different silica morphologies as a function of flowrate and backpressure using the enzyme reactor assay mode. It was found that the apparent activity of the enzyme was highest in mesoporous columns that retained high levels of enzyme. In such columns, enzyme activity increased by ∼2-fold with increases in both flowrate (from 250 to 1000 nL/min) and backpressure generated (from 500 to 2100 psi) during the chromatographic activity assay owing to increases in kcat and decreases in KM, switching from diffusion controlled to reaction controlled conditions at ca. 2000 psi. These results suggest that columns with minimal macropore volumes (<5%) are advantageous for the entrapment of soluble proteins for bioaffinity and bioreactor chromatography.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号