首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new diffusion-based solid-phase microextraction (SPME) time-weighted average (TWA) field water sampling device was developed and investigated by field trial. The sampler is constructed with copper tube and caps and a commercial SPME fiber assembly. The device possesses all advantages of SPME; it is solvent-free, reusable, combines sampling, isolation and enrichment into one step, and the fiber can be directly injected into a gas chromatograph for analysis with a commercial SPME fiber holder, without further treatment. Field trials in Laurel Creek (Waterloo, Ont., Canada) and Hamilton Harbour (Hamilton, Ont., Canada) illustrated that the device is durable, easy to deploy, and the mass uptake of the device is independent of the face velocity. The device provides good precision [relative standard deviations (RSDs) are less than 20%] and the data obtained with this device are quite comparable to those obtained with the spot sampling method, which demonstrates that the newly developed SPME water sampling device is suitable for long-term monitoring of organic pollutants in water.  相似文献   

2.
A stainless steel cell with an in-cell solid-phase microextraction (SPME) sampling device is proposed to investigate the permeation of dichloromethane, 1,2-dichloroethane, and benzene through a high-density polyethylene (HDPE) membrane. The advantage of using SPME as a direct sampling device in the collection chamber is that it is a simple and sensitive means to monitor the concentrations of organic compounds in the collection medium for a closed-loop test system. Compared with the permeation results for an ASTM F739 cell, the standardized breakthrough times were shorter and the permeability coefficients were greater using the alternative cell. Although the optimum SPME sampling parameters should be obtained in advance, the in-cell SPME method can be an appropriate approach to determine the resistance of polymeric membranes to permeation by organic solvents.  相似文献   

3.
A solid-phase microextraction (SPME) method was developed for air monitoring of organic solvents frequently used in chemical laboratories (namely pentane, dimethyl ether, acetone, acetonitrile, dichloromethane, hexane, ethylacetate, tetrahydrofurane, cyclohexane, benzene, and toluene). SPME sampling conditions and chromatographic separation were optimised. Linearity of response for each component of the mixture was tested. Standard solutions containing all the compounds, at three different concentrations, were analysed in triplicate and the relative standard deviations (RSDs) were calculated. The method was applied to the monitoring of indoor air in a research chemical laboratory. An SPME fibre was used as a sampling device inside the laboratory. Moreover an SPME fibre was used as a portable sampling device in order to determine the effective human exposure. Comparison of the portable and fixed sampling device showed differences in the amount of solvents associated with activities performed nearby.  相似文献   

4.
This article presents the results of an exploratory application of the Solid Phase MicroExtraction (SPME) technique to the analysis of BTEX (benzene, toluene, ethylbenzene and xylenes) at the microg/m3 level in outdoor and indoor air. The salient features of the method validation are reported. As shown by the various examples of field sampling described, SPME technique appears as a method of choice for fast qualitative analysis and quantitative determination of Volatile Organic Compounds (VOC). The small dimensions of the SPME sampling system and the short sampling time let envisage its utilisation for the rapid diagnostic of outdoor and indoor air quality.  相似文献   

5.
The use of solid-phase microextraction (SPME) for in vivo sampling of drugs and metabolites in the bloodstream of freely moving animals eliminates the need for blood withdrawal in order to generate pharmacokinetics (PK) profiles in support of pharmaceutical drug discovery studies. In this study, SPME was applied for in vivo sampling in mice for the first time and enables the use of a single animal to construct the entire PK profile. In vivo SPME sampling procedure used commercial prototype single-use in vivo SPME probes with a biocompatible extractive coating and a polyurethane sampling interface designed to facilitate repeated sampling from the same animal. Pre-equilibrium in vivo SPME sampling, kinetic on-fibre standardization calibration and liquid chromatography–tandem mass spectrometry analysis (LC–MS/MS) were used to determine unbound and total circulating concentrations of carbamazepine (CBZ) and its active metabolite carbamazepine-10,11-epoxide (CBZEP) in mice (n = 7) after 2 mg/kg intravenous dosing. The method was linear in the range of 1–2000 ng/mL CBZ in whole blood with acceptable accuracy (93–97%) and precision (<17% RSD). The single dose PK results obtained using in vivo SPME sampling compare well to results obtained by serial automated blood sampling as well as by the more conventional method of terminal blood collection from multiple animals/time point. In vivo SPME offers the advantages of serial and repeated sampling from the same animal, speed, improved sample clean-up, decreased animal use and the ability to obtain both free and total drug concentrations from the same experiment.  相似文献   

6.
Headspace solid phase microextraction (headspace SPME) has been demonstrated to be an excellent solvent-free sampling method. One of the major factors contributing to the success of headspace SPME is the concentrating effect of the fiber coating toward organic compounds. The affinity of the fiber coating toward very volatile analytes, such as chloromethane, may, however, not be large enough for detection at the parts per trillion concentration level. Static headspace analysis, on the other hand, is very effective for these very volatile compounds. As analyte volatility decreases, the sensitivity of static headspace analysis drops. The complementary nature of these two sampling methods can be exploited by combining the SPME device with a gastight syringe. The sensitivity of the new sampling device is better than that of SPME for very volatile compounds or that of static headspace analysis for less volatile compounds. This new method can sample a wide range of compounds from chloromethane (b.p. −24°C) to bromoform (b.p. 149°C) with estimated limits of detection at the low parts per trillion level.  相似文献   

7.
Solid phase micro-extraction (SPME) was used to collect air samples of semi-volatile organophosphate triesters, a group of compounds that are commonly used as flame retardants/plasticisers and have therefore become ubiquitous indoor air pollutants. SPME is a simple sampling technique with several major advantages, including time-efficiency and low solvent consumption. Analyte losses also tend to be relatively low. In quantitative SPME, measurements are normally taken after the analyte has reached partitioning equilibrium between the fibre and the sample matrix. However, equilibrium sampling of semi-volatile compounds in air with SPME often takes several hours. Clearly, time-weighted average (TWA) sampling using SPME under non-equilibrium conditions could be considerably faster. So, in this study, the possibility of sampling organophosphate triesters under non-equilibrium conditions was tested. The most important variables proved to be the fibre coating and the air velocity during sampling. The highest uptake rate was obtained with polydimethylsiloxane (PDMS, 100 m). The rate for this fibre was 150-fold higher than obtained with PDMS/DVB and Carbowax/DVB, both 65 m. Contrary to theoretical expectations, the uptake rate appeared to be constant for all tested air velocities over the fibre surface >7 cm/s. These findings suggest that the uptake rate for non-equilibrium SPME sampling is independent of the sampling flow above this flow rate, which would considerably enhance the robustness and flexibility of the method. Applying this method for TWA sampling, with sampling periods of 1 h, detection limits lower than 2 ng/m3 for individual organophosphate esters were obtained.  相似文献   

8.
In vivo solid-phase microextraction (SPME) can be used to sample the circulating blood of animals without the need to withdraw a representative blood sample. In this study, in vivo SPME in combination with liquid–chromatography tandem mass spectrometry (LC–MS/MS) was used to determine the pharmacokinetics of two drug analytes, R,R-fenoterol and R,R-methoxyfenoterol, administered as 5 mg kg−1i.v. bolus doses to groups of 5 rats. This research illustrates, for the first time, the feasibility of the diffusion-based calibration interface model for in vivo SPME studies. To provide a constant sampling rate as required for the diffusion-based interface model, partial automation of the SPME sampling of the analytes from the circulating blood was accomplished using an automated blood sampling system. The use of the blood sampling system allowed automation of all SPME sampling steps in vivo, except for the insertion and removal of the SPME probe from the sampling interface. The results from in vivo SPME were compared to the conventional method based on blood withdrawal and sample clean up by plasma protein precipitation. Both whole blood and plasma concentrations were determined by the conventional method. The concentrations of methoxyfenoterol and fenoterol obtained by SPME generally concur with the whole blood concentrations determined by the conventional method indicating the utility of the proposed method. The proposed diffusion-based interface model has several advantages over other kinetic calibration models for in vivo SPME sampling including (i) it does not require the addition of a standard into the sample matrix during in vivo studies, (ii) it is simple and rapid and eliminates the need to pre-load appropriate standard onto the SPME extraction phase and (iii) the calibration constant for SPME can be calculated based on the diffusion coefficient, extraction time, fiber length and radius, and size of the boundary layer. In the current study, the experimental calibration constants of 338.9 ± 30 mm−3 and 298.5 ± 25 mm−3 are in excellent agreement with the theoretical calibration constants of 307.9 mm−3 and 316.0 mm−3 for fenoterol and methoxyfenoterol respectively.  相似文献   

9.
Four sampling techniques, solid-phase microextraction (SPME), supercritical fluid extraction (SFE), steam distillation (SD), and solvent extraction (SE), were compared for the analysis of volatile constituents from a traditional Chinese medicine (TCM) of the dried ripe fruit of Fructus Amomi (Sha Ren). A total of 38 compounds were identified by gas chromatography/mass spectrometry. Different SFE and SPME parameters (modifier content, extraction pressure, and temperature for SFE and fibers, extraction temperature, and time for SPME) were studied. The results by SFE and SPME were compared with those obtained by conventional SD and SE methods. The results showed that SFE and SPME are better sample preparation techniques than SD and SE. Due to SFE's requirement for expensive specialized instrumentation, the simplicity, low cost, and speed of SPME make it a more appropriate technique for extraction of volatile constituents in TCMs.  相似文献   

10.
The popular solid phase micro extraction (SPME) device and method is compared with SnifProbe (Gordin and Amirav in J Chromatogr A 903:155–172, 2000) in their application for coffee aroma sampling for its analysis. The main difference between SPME and SnifProbe is in the relative motion of the sampled air. While SPME is based on static air sampling and the achievement of equilibrium, SnifProbe is based on active air pumping through the adsorption trap. A second important difference concerns the sample introduction into the GC injector for its intra injector thermal desorption. SPME is based on the use of a special syringe for sample introduction without any change to the injector, while SnifProbe requires a ChromatoProbe for sample introduction. We found that as a result of these differences, while SnifProbe provides a more faithful (representative) headspace and aroma sample collection, SPME is characterized by major compound dependent sample bias. In addition, SnifProbe enabled much faster sample collection than SPME. Since SnifProbe uses the ChromatoProbe for sample introduction into the GC, bigger sample collection/trapping devices such as silicone tubing can be used, and as a result, over ten times superior SnifProbe sensitivity (versus SPME) was demonstrated. Additional SnifProbe and SPME features are compared and discussed.  相似文献   

11.
Solid-phase microextraction (SPME) and capillary electrophoresis (CE) are two of the main inventions that shaped 20th Century analytical chemistry. SPME is an effective microscale sampling and sample preparation technique, and CE is a high-efficiency microanalytical method. Online coupling of SPME with CE can be a powerful combination because of the significant advantages of the two techniques. The progress in the development of online SPME-CE coupling is surveyed in this review. Problems encountered and solutions reported are highlighted.  相似文献   

12.
Field air analysis with SPME device   总被引:5,自引:0,他引:5  
Solid-phase microextraction (SPME) devices were used for a wide scope of air-monitoring including field sampling and analysis of volatile organic compounds (VOCs), formaldehyde, and particulate matter (PM) in air. Grab (instantaneous) and time-weighted average (TWA) sampling were accomplished using exposed and retracted SPME fibers, respectively. Sampling time varied from 1 to 75 min, followed by analysis with a gas chromatograph (GC). A portable GC equipped with unique, in-series detectors: photoionization (PID), flame ionization (FID), and dry electrolytic conductivity (DELCD), provided almost real-time analysis and speciation for common VOCs during an indoor air quality surveys. Indoor air samples collected with SPME devices were compared with those collected using conventional National Institute for Occupational Safety and Health (NIOSH) methods. Air concentrations measured with the SPME device were as low as 700 parts-per-trillion (ppt) for semi-volatile organic compounds. SPME methodology proved to be more sensitive than conventional methods, and provided a simple approach for fast, cost-effective sampling and analysis of common VOCs in indoor air. SPME technology combined with fast portable GC reduced the sampling and analysis time to less than 15 min. The configuration offered the conveniences of immediate on-site monitoring and decision making, that are not possible with conventional methods. In addition, SPME fibers were applied to sampling of particulate matter in diesel engine exhaust. Linear uptake and particulate build-up on the fiber were observed. Preliminary research suggests that SPME fibers could also be applied to sampling of airborne particulate matter.  相似文献   

13.
A new and simple method for benzene, toluene, ethylbenzene and o-xylene (BTEX) quantification in vehicle exhaust was developed based on diffusion-controlled extraction onto a retracted solid-phase microextraction (SPME) fiber coating. The rationale was to develop a method based on existing and proven SPME technology that is feasible for field adaptation in developing countries. Passive sampling with SPME fiber retracted into the needle extracted nearly two orders of magnitude less mass (n) compared with exposed fiber (outside of needle) and sampling was in a time weighted-averaging (TWA) mode. Both the sampling time (t) and fiber retraction depth (Z) were adjusted to quantify a wider range of Cgas. Extraction and quantification is conducted in a non-equilibrium mode. Effects of Cgas, t, Z and T were tested. In addition, contribution of n extracted by metallic surfaces of needle assembly without SPME coating was studied. Effects of sample storage time on n loss was studied. Retracted TWA–SPME extractions followed the theoretical model. Extracted n of BTEX was proportional to Cgas, t, Dg, T and inversely proportional to Z. Method detection limits were 1.8, 2.7, 2.1 and 5.2 mg m−3 (0.51, 0.83, 0.66 and 1.62 ppm) for BTEX, respectively. The contribution of extraction onto metallic surfaces was reproducible and influenced by Cgas and t and less so by T and by the Z. The new method was applied to measure BTEX in the exhaust gas of a Ford Crown Victoria 1995 and compared with a whole gas and direct injection method.  相似文献   

14.
An in situ application of solid-phase microextraction (SPME) as a sampling and sample preparation method coupled to HPLC-MS/MS for direct monitoring of ochratoxin A (OTA) distribution at different locations in a single cheese piece is proposed. To be suited to the acidic analyte, the extraction phase (carbon-tape SPME fiber) was acidified with aqueous solution of HCl at pH 2, instead of the traditional sample pre-treatment with acids before SPME sampling. For calibration, kinetic on-fiber-standardization was used, which allowed the use of short sampling time (20 min) and accurate quantification of the OTA in the semi-solid cheese sample. In addition, the traditional kinetic calibration that used deuterated compounds as standards was extended to use a non-deuterated analogue ochratoxin B (OTB) as the standard of the analyte OTA, which was supported by both theoretical discussion and experimental verification. Finally, the miniaturized SPME fiber was adopted so that the concentration distribution of OTA in a small-sized cheese piece could be directly probed. The detection limit of the resulting SPME method in semi-solid gel was 1.5 ng/mL and the linear range was 3.5–500 ng/mL. The SPME–LC-MS/MS method showed good precision (RSD: ∼10%) and accuracy (relative recovery: 93%) in the gel model. The direct cheese analysis showed comparable accuracy and precision to the established liquid extraction. As a result, the developed in situ SPME–LC-MS/MS method was sensitive, simple, accurate and applicable for the analysis of complicated lipid-rich samples such as cheese.  相似文献   

15.
Solid phase microextraction (SPME), a simple, fast and promising sampling technique, has been widely used for complex sample analysis. However, complex matrices could modify the absorption property of coatings as well as the uptake kinetics of analytes, eventually biasing the quantification results. In the current study, we demonstrated the feasibility of a developed calibration method for the analysis of polycyclic aromatic hydrocarbons (PAHs) in complex milk samples. Effects of the complex matrices on the SPME sampling process and the sampling conditions were investigated. Results showed that short exposure time (pre-equilibrium SPME, PE-SPME) could increase the lifetime of coatings, and the complex matrices in milk samples could significantly influence the sampling kinetics of SPME. In addition, the optimized sampling time, temperature and dilution factor for PAHs were 10 min, 85 °C and 20, respectively. The obtained LODs and LOQs of all the PAHs were 0.1–0.8 ng/mL and 1.4–4.7 ng/mL, respectively. Furthermore, the accuracy of the proposed PE-SPME method for milk sampling was validated by the recoveries of the studied compounds in two concentration levels, which ranged from 75% to 110% for all the compounds. Finally, the proposed method was applied to the screening of PAHs in milk samples.  相似文献   

16.
The aim of the study was to analyse BTEX compounds (benzene, toluene, ethylbenzene, xylenes) in air by solid phase micro-extraction/gas chromatography/mass spectrometry (SPME/GC/MS), and this article presents the features of the calibration method proposed. Examples of real-world air analysis are given. Standard gaseous mixtures of BTEX in air were generated by dynamic dilution. SPME sampling was carried out under non-equilibrium conditions using a Carboxen/PDMS fibre exposed for 30 min to standard gas mixtures or to ambient air. The behaviour of the analytical response was studied from 0 to 65 g/m3 by adding increasing amounts of BTEX to the air matrix. Detection limits range from 0.05 to 0.1 g/m3 for benzene, depending on the fibre. Inter-fibre relative standard deviations (reproducibility) are larger than 18%, although the repeatability for an individual fibre is better than 10%. Therefore, each fibre should be considered to be a particular sampling device, and characterised individually depending on the required accuracy. Sampling indoor and outdoor air by SPME appears to be a suitable short-delay diagnostic method for volatile organic compounds, taking advantage of short sampling time and simplicity.  相似文献   

17.
Solid-phase microextraction (SPME) was evaluated as a tool for headspace sampling of tobacco samples. Several experimental parameters (e.g. sampling temperature, pH, moisture, and the type of SPME fibers) were optimized to improve sampling efficiency in two aspects; maximum adsorption and selective adsorption of volatile components onto SPME fibers. The effect of these parameters was often dominated by the physical and chemical nature (e.g. volatility, polarity) of target compounds, thus, SPME sampling conditions can be adjusted to favor a selected group of compounds, such as organic acids in tobacco.  相似文献   

18.
Epichlorohydrin is used frequently in many industrial processes. Exposure to this pollutant could induce harmful effects. The present work developed a novel solid phase microextraction (SPME) method for time weighted average determination of epichlorohydrin in the air by GC/MS. CAR/PDMS in 0.5?cm retracted mode was selected and the effect of environmental parameters on sampling properties of SPME was examined. Experimental sampling rate for epichlorohydrin (8.89?×?10?3?cm3/min) was slightly less than theoretical value (9.059?×?10?3?cm3/min). There was no significant difference among sampling rates at different temperature and velocities but relative humidity had a significant effect on the sampling rate. Limit of detection for SPME method was 0.8?ng per sample, which is good enough in comparison with the NIOSH 1010 method. Comparison of the results between the developed SPME and the NIOSH 1010 method on standard test atmosphere and field showed satisfactory agreement (y?=?1.162x?+?1.8 r 2?=?0.992 and y?=?1.009x+0.76 r 2?=?0.98 respectively).  相似文献   

19.
Methyl tert-butyl ether (MTBE) is commonly used as chemical additive to increase oxygen content and octane rating of reformulated gasoline. Despite its impact on enhancing cleaner combustion of gasoline, MTBE poses a threat to surface and ground water when gasoline is released into the environment. Methods for onsite analysis of MTBE in water samples are also needed. A less common technique for MTBE detection from water is ion mobility spectrometry (IMS). We describe a method for fast sampling and screening of MTBE from water by solid phase microextraction (SPME) and IMS. MTBE is adsorbed from the head space of a sample to the coating of SPME fiber. The interface containing a heated sample chamber, which couples SPME and IMS, was constructed and the SPME fiber was introduced into the sample chamber for thermal desorption and IMS detection of MTBE vapors. The demonstrated SPME-IMS method proved to be a straightforward method for the detection of trace quantities of MTBE from waters including surface and ground water. We determined the relative standard deviation of 8.3% and detection limit of 5 mg L−1 for MTBE. Because of short sampling, desorption, and detection times, the described configuration of combined SPME and IMS is a feasible method for the detection of hazardous substances from environmental matrices.  相似文献   

20.
固相微萃取-气相色谱/质谱分析栀子花的头香成分   总被引:30,自引:0,他引:30  
刘百战  高芸 《色谱》2000,18(5):452-455
 分别用固相微萃取和动态顶空法分离栀子鲜花的头香成分,用GC/MS技术分析鉴定,并用GC/MS总离子流色谱峰的峰面积进行归一化定量。在固相微萃取方法中,共鉴定了54种化学成分,占总峰面积的99.98%。主要成分(质量分数)依次为金合欢烯(64.86%)、罗勒烯(29.33%)、芳樟醇(2.74%)、惕各酸顺式叶醇酯(1.34%)和苯甲酸甲酯(0.25%)等。经与动态顶空法的分析结果比较发现,固相微萃取法不仅操作简便,而且具有较高的采样灵敏度,获得的化学成分的信息量多于动态顶空法。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号