首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An inductively coupled plasma mass spectrometer (ICP-MS) was used as an ion chromatographic detector for the speciation of iodine and bromine. Gradient elution using NH4NO3 at pH 10 allowed the chromatographic separation of ionic iodine (I- and IO3-) and bromine (Br- and BrO3-) species in less than 8 min. Effluents from the ion-exchange column were delivered to the nebulization system of ICP-MS for the determination of I and Br. The potentially interfering 38Ar40ArH+ and 40Ar40ArH+ at the bromine masses m/z 79 and 81 were significantly reduced in intensity (by approximately two orders of magnitude) by using 0.6 mL min(-1) O2 as a reactive cell gas in the dynamic reaction cell (DRC). Moreover, the signal-to-background ratio at iodine mass m/z 127 increased significantly when O2 was used as the reaction gas. The detection limits were in the range of 0.001-0.002 and 0.03-0.04 ng mL(-1) for various I and Br compounds, respectively, based on the peak height. The relative standard deviation of the peak areas for five injections of a 2 ng mL(-1) I-, IO3- and 20 ng mL(-1) Br-, BrO3- mixture was in the range of 3-4%. The concentrations of I and Br compounds have been determined in selected water and urine samples. The spike recoveries were in the range of 94-102% for all of the determinations. This method has also been applied to determine various I and Br compounds in an NIST RM 8435 whole-milk powder reference material and a seaweed sample obtained locally. A microwave-assisted extraction method was used to extract these compounds, which were quantitatively leached with a 10% mass/volume (m/v) tetramethylammonium hydroxide (TMAH) solution in a focused microwave field within a period of 6 min. The major components of I and Br in milk powder and seaweed were I- and Br-.  相似文献   

2.
Chen JH  Wang KE  Jiang SJ 《Electrophoresis》2007,28(22):4227-4232
A CE-inductively coupled plasma mass spectrometric (CE-ICP-MS) method for iodine and bromine speciation analysis is described. Samples containing ionic iodine (I(-) and IO(3)(-)) and bromine (Br(-) and BrO(3)(-)) species are subjected to electrophoretic separation before injection into the microconcentric nebulizer (CEI-100). The separation has been achieved in a 50 cm length x 75 microm id fused-silica capillary. The electrophoretic buffer used is 10 mmol/L Tris (pH 8.0), while the applied voltage is set at -8 kV. Detection limits are 1 and 20-50 ng/mL for various I and Br compounds, respectively, based on peak height. The RSD of the peak areas for seven injections of 0.1 microg/mL I(-), IO(3)(-) and 1 microg/mL Br(-), BrO(3)(-) mixture is in the range of 3-5%. This method has been applied to determine various iodine and bromine species in NIST SRM 1573a Tomato Leaves reference material and a salt and seaweed samples obtained locally. A microwave-assisted extraction method is used for the extraction of these compounds. Over 87% of the total iodine and 83% of the total bromine are extracted using a 10% m/v tetramethylammonium hydroxide (TMAH) solution in a focused microwave field within a period of 10 min. The spike recoveries are in the range of 94-105% for all the determinations. The major species of iodine and bromine in tomato leaves, salt, and seaweed are Br(-), IO(3)(-), I(-), and Br(-), respectively.  相似文献   

3.
An inductively coupled plasma mass spectrometer (ICP-MS) with a rapid sample-preparative procedure was used for the determination of selenium in blood serum. Blood serum was prepared by dilution in an acidic solution consisting of nitric acid (1%), X-triton (0.1%) and 1-butanol (0.8%). A calibration curve was established for 1-40 microg mL(-1) (r(2)>0.99). The limit of detection was 0.5 microg mL(-1). Repeatability and intermediate precision were satisfactory with relative standard deviations (RSD) of 2.0% and 3.2%, respectively. This method was easily applied to reference materials with satisfactory accuracy. Good correlation (r(2)=0.96) was observed between ICP-MS and atomic absorption spectrometry (AAS) for the determination of (82)Se in blood serum from 23 patients. These results suggest that the sample preparative procedure coupled with ICP-MS can be used for the routine determination of (82)Se in human blood serum.  相似文献   

4.
A precise, accurate, and sensitive UV spectrophotometric method was developed and validated for routine quantification of total bioflavonoids, expressed as rutin, from a topical oil-in-water pharmaceutical emulsion containing the extract of Trichilia catigua Adr. Juss and Ptychopetalum olacoides Bentham. The method was validated experimentally, and the data were treated rigorously by statistical analysis. The following analytical parameters were assessed: linearity, specificity, intra- and interrun precision measured as relative standard deviation (RSD, %), intra- and interrun accuracy (E, %), recovery (Rec., %), limit of detection (LOD, microg/mL), and limit of quantification (LOQ, microg/mL). The UV spectrophotometric method was linear (r = 0.9995) for standard rutin over the concentration range of 5.0-15.0 microg/mL with specificity for total bioflavonoids (expressed as rutin) at 361.0 nm with an absence of interferents from the complex matrix; RSD of < or = 1.79%, intrarun (E = 97.88 +/- 1.75 to 99.0 +/- 0.33%) and interrun (E = 98.38 +/- 1.12 to 100.79 +/- 1.30%) accuracy; Rec. = 98.64 +/- 0.42 to 100.74 +/- 0.41%; LOD = 0.20 microg/mL; and LOQ = 0.30 microg/mL.  相似文献   

5.
Part of a comprehensive study on the comparison of different extraction methods, GC-MS(/MS) and LC-MS/MS detection methods and modes, for the analysis of soya samples is described in this paper. The validation of an acetone-based extraction method for analysis of 169 pesticides in soya, using LC-MS/MS positive and negative electrospray ionisation (ESI) mode, is reported. Samples (5 g) were soaked with 10 g water and subsequently extracted with 100 mL of a mixture of acetone, dichloromethane and light petroleum (1:1:1), in the presence of 15 g anhydrous sodium sulphate. After centrifugation, aliquots of the extract were evaporated and reconstituted in 1.0 mL of methanol, before direct injection of the final extract (corresponding with 0.05 g soya mL(-1)) into the LC-MS/MS system. Linearity, r(2) of calibration curves, instrument limit of detection/quantitation (LOD/LOQ) and matrix effect were evaluated, based on seven concentrations measured in 6-fold. Good linearity (at least r(2)> or =0.99) of the calibration curves was obtained over the range from 0.1 or 0.25 to 10.0 ng mL(-1), corresponding with pesticide concentrations in soya bean extract of 2 or 5-200 microg kg(-1). Instrument LOD values generally were 0.1 or 0.25 ng mL(-1). Matrix effects were negligible for approximately 90% of the pesticides. The accuracy, precision and method LOQ were determined via recovery experiments, spiking soya at 10, 50, 100 microg kg(-1), six replicates per level. In both ESI modes, method LOQ values were mostly 10 or 50 microg kg(-1) and more than 70% of pesticides analysed by each mode met the acceptability criteria of recovery (70-120%) and RSD (< or =20%), at one or more of the three levels studied. A fast, easy and efficient method with acceptable performance was achieved for a difficult matrix as soya, without cleanup.  相似文献   

6.
A new liquid chromatography with tandem mass spectrometry method was developed and validated for the simultaneous determination of trifolirhizin, (–)‐maackiain, (–)‐sophoranone, and 2‐(2,4‐dihydroxyphenyl)‐5,6‐methylenedioxybenzofuran from Sophora tonkinensis in rat plasma using chlorpropamide as an internal standard. Plasma samples (50 μL) were prepared using a simple deproteinization procedure with 150 μL of acetonitrile containing 100 ng/mL of chlorpropamide. Chromatographic separation was carried out on an Acclaim RSLC120 C18 column (2.1 × 100 mm, 2.2 μm) using a gradient elution consisting of 7.5 mM ammonium acetate and acetonitrile containing 0.1% formic acid (0.4 mL/min flow rate, 7.0 min total run time). The detection and quantitation of all analytes were performed in selected reaction monitoring mode under both positive and negative electrospray ionization. This assay was linear over concentration ranges of 50–5000 ng/mL (trifolirhizin), 25–2500 ng/mL ((–)‐maackiain), 5–250 ng/mL ((–)‐sophoranone), and 1–250 ng/mL 2‐(2,4‐dihydroxyphenyl)‐5,6‐methylenedioxybenzofuran) with a lower limit of quantification of 50, 25, 5, and 1 ng/mL for trifolirhizin, (–)‐maackiain, (–)‐sophoranone, and 2‐(2,4‐dihydroxyphenyl)‐5,6‐methylenedioxybenzofuran, respectively. All the validation data, including the specificity, precision, accuracy, recovery, and stability conformed to the acceptance requirements. The results indicated that the developed method is sufficiently reliable for the pharmacokinetic study of the analytes following oral administration of Sophora tonkinensis extract in rats.  相似文献   

7.
In this study, the development and validation of an analytical method for the assay of 4,7-phenanthroline-5,6-dione I (dione I) using high-performance liquid chromatography (HPLC) and the determination of its synthetic impurities by employing the method in HPLC-mass spectrometry with atmospheric-pressure chemical ionization and photodiode-array UV detection is reported. The results show that dione I is eluted as a spectrally pure peak resolved from its impurities. 5-Bromo,4-7-phenanthroline is identified as the main impurity. This is supported by elemental analysis of the dione I, which demonstrated the presence of bromine. Validation parameters such as specificity and selectivity, linearity, accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ), ruggedness, stability, and system suitability, which are evaluated for this method. The LOD and LOQ are 2.0 microg/mL and 50 microg/mL with a 0.50% relative standard deviation (%RSD), respectively. The calibration curves showed good linearity over the concentration range of 0.05-1.50 mg/mL. The correlation coefficient is > 0.9991 in each case. The %RSD values for intra- and interday precision studies are < 0.40%.  相似文献   

8.
Analysis of glucose and other carbohydrates are often performed by use of normal phase HPLC methods with acetonitrile as major eluent coupled with evaporative light-scattering detector (ELSD) or by use of anion-exchange ion chromatography (IC) methods with NaOH as eluent coupled with pulsed amperimetric electrochemical detector. In this work, a novel method for the determination of carbohydrates by IC in conjunction with a self-regenerating suppressor and an ELSD detector was investigated. Three carbohydrates (glucose, fructose, and sucrose) were separated using a KOH eluent generator to avoid the effect of carbon dioxide absorption in the alkaline eluent. Due to the use of the suppressor, non-volatile components were removed and a low salt background (K+ approximately 0.070 microg/mL) can be obtained so the suppressed eluent could directly go into an ELSD detector without obvious interference of inorganic salts. After examining the changes in retention and resolution, an optimized method was established (for IC: using 32 mM KOH as the eluent at a flow rate of 1 mL/min; for ELSD: operated at 95 degrees C, 4.0 bar nitrogen with a gas flow rate of 2.0 L/min) and the linearity, reproducibility, and the limit of detection (LOD) for the three carbohydrates were further evaluated. Regression equations revealed acceptable linearity (correlation coefficients=0.994-0.998) across the working-standard range (100-1000 microg/mL for glucose and sucrose, 150-1000 microg/mL for fructose) and LODs of glucose, fructose, and sucrose were 93, 126, and 90 microg/mL, respectively. This method has successfully been applied to the determination of the three carbohydrates in carbonated cola drinks and fruit juices. The recoveries were between 95 and 113% (n=3) for different carbohydrates.  相似文献   

9.
A novel method for the non-derivatization liquid chromatographic determination of streptomycin (STR) and dihydrostreptomycin (DHSTR) was developed and validated based on evaporative light scattering detection (ELSD). Utilizing a ThermoHypersil BetaBasic C18 analytical column, evaporation temperature of 50 degrees C and pressure of nebulizing gas (nitrogen) of 3.5 bar, the optimized mobile phase was 1.25 mL L(-1) TFA aqueous solution, in an isocratic mode at a rate of 1.0 mL min(-1). STR was eluted at 5.6 min and DHSTR at 7.8 min with a resolution of 4.4. Linear calibration curves were obtained from 2 to 120 microg mL(-1) (r > 0.9990) for STR and 2-75 microg mL(-1) (r > 0.9994) for DHSTR, with a LOD equal to 0.7 and 0.5 microg mL(-1), respectively. The developed method was applied for the assay of STR and DHSTR (sulfate) in pharmaceutical raw materials and formulations, while the simultaneous direct determination of sulfate was feasible (tR = 2.5 min, LOD = 1.4 microg mL(-1), double logarithmic calibration curve in the range of 4-50 microg mL(-1), r > 0.9998). Modified isocratic mobile phase (H2O-ACN, 90:10, v/v, containing 1.25 mL L(-1) TFA), was used for the determination of streptomycin B impurity in STR sulfate raw material and a gradient mobile phase (H2O-ACN containing TFA) was used for the determination of DHSTR in the presence of penicillinG procaine. The developed method was also applied for the assay of commercial formulations (STR powder and DHSTR injection solution and suspension) (%recovery 98-102, %RSD < 1.3, n = 3 x 3), for the determination of STR in bacteria culture medium (%recovery 99.6, %RSD = 0.8, n = 3 x 3), and for the determination of DHSTR in human plasma (2.0-23.0 microg mL(-1)) after solid phase extraction using carboxylate cartridges (%recovery 98.4-101.8, %RSD = 3.2, n = 3 x 3).  相似文献   

10.
A CZE method was developed, which separates 2',3'-dideoxyadenosine-5'-triphosphate (ddATP) from other metabolites and endogenous nucleotides at high concentrations (20-200 microg/mL) to allow UV detection. To enhance sensitivity, fluorescence detection which requires prior derivatization of compounds was examined. Precapillary derivatization of ddATP in the presence of N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDAC) with dansyl ethylenediamine (dansyl EDA) was faster and stable compared to that of 4,4-difluoro-5,7-dimethyl-4-bora-3a,4a-diaza-s-indacene-3-propionyl ethylenediamine (BODIPY FL EDA). Reaction conditions, reagent concentrations and detection parameters were optimized and highest derivatization efficiency was achieved in 0.1 M 1-methylimidazole buffer (pH 8.0) with 140 mM EDAC in 1-methylimidazole buffer and 30 mM dansyl EDA in DMF for 90 min at 60 degrees C. Dansyl EDA derivatives of ddATP, 2'-deoxyadenosine-5'-triphosphate (dATP) and ATP were comigrating with the CZE method; therefore, a MEKC method was developed and optimized for repeatable separations. Upon dansylation, sensitivity of ddATP with fluorescence detection (LOQ = 12 ng/mL) was 160 times higher than UV detection (LOQ = 1.9 microg/mL).  相似文献   

11.
An implementation of the Dionex IonPac AS12A analytical column with an element-specific ICP-MS detection is described for the simultaneous determination of halogen and oxyhalogen anions, sulfate, phosphate, selenite, selenate and arsenate. The chromatographic separation was achieved in less than 4 min with an aqueous 11 mM (NH4)2CO3 (pH 11.2, adjusted with aqueous ammonia) as eluent. Special emphasis was given to optimize the ICP-MS detection conditions for the reliable detection (RSD<5%) of bromate and bromide at a bromine concentration level of 1.0 microg l(-1) with 50 microl sample injection volume. In order to achieve the highest detector response for bromine species an ultrasonic nebulizer equipped with a membrane desolvator had to be employed. The detection limits (S/N=3, sample injection volume 50 microl) obtained with the IC-ICP-MS after the optimization were 0.67 microg l(-1) for BrO3-, 0.47 microg l(-1) for Br-, 69 microg l(-1) for ClO2-, 4 microg l(-1) for Cl-, 47 microg l(-1) for ClO3-, 13 microg l(-1) for SO4(2-), 36 microg l(-1) for PO4(3-), 0.4 microg l(-1) for SeO3(2-), 0.3 microg l(-1) for SeO4(2-), and 0.4 microg l(-1) for AsO4(3-).  相似文献   

12.
We report 355 nm photodissociation studies of molecular bromine (Br2) trapped in solid parahydrogen (pH2) and orthodeuterium (oD2). The product Br atoms are observed via the spin-orbit transition ((2)P(1/2)<-- (2)P(3/2)) of atomic bromine. The quantum yield (Phi) for Br atom photoproduction is measured to be 0.29(3) in pH2 and 0.24(2) in oD2, demonstrating that both quantum solids have minimal cage effects for Br2 photodissociation. The effective Br spin-orbit splitting increases when the Br atom is solvated in solid pH2 (+1.1%) and oD2 (+1.5%); these increases are interpreted as evidence that the solvation energy of the Br ground fine structure state ((2)P(3/2)) is significantly greater than the excited state ((2)P(1/2)). Molecular bromine induced H2 infrared absorptions are detected in the Q1(0) and S1(0) regions near 4150 and 4486 cm(-1), respectively, which allow the relative Br2 concentration to be monitored as a function of 355 nm photolysis.  相似文献   

13.
A rapid, sensitive and specific method to quantify bromazepam in human plasma using diazepam as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using diethyl ether-hexane (80 : 20, v/v). The extracts were analyzed by high-performance liquid chromatography (HPLC) coupled to electrospray tandem mass spectrometry (MS/MS). Chromatography was performed isocratically on a Genesis C(18) analytical column (100 x 2.1 mm i.d., film thickness 4 microm). The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 5.0-150 ng ml(-1) (r(2) > 0.9952). The limit of quantification was 5 ng ml(-1). This HPLC/MS/MS procedure was used to assess the bioequivalence of two bromazepam 6 mg tablet formulations (bromazepam from Medley SA Indústria Farmacêutica as the test formulation and Lexotan from Produtos Roche Químico e Farmacêutico SA as the reference formulation). A single 6 mg dose of each formulation was administered to 24 healthy volunteers (12 males and 12 females). The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. Since the 90% CI for C(max), AUC(last), AUC(0-240 h) (linear) and AUC((0- infinity )) ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration, it was concluded that the bromazepam formulation from Medley is bioequivalent to the Lexotan formulation for both the rate and the extent of absorption.  相似文献   

14.
A procedure for the simultaneous determination of bromine and iodine by inductively coupled plasma (ICP) mass spectrometry was investigated. In order to prevent the decrease in the ionization efficiencies of bromine and iodine atoms caused by the introduction of water mist, electrothermal vaporization was used for sample introduction into the ICP mass spectrometer. To prevent loss of analytes during the drying process, a small amount of tetramethylammonium hydroxide solution was placed as a chemical modifier into the tungsten boat furnace. After evaporation of the solvent, the analytes instantly vaporized and were then introduced into the ICP ion source to detect the (79)Br(+), (81)Br(+), and (127)I(+) ions. By using this system, detection limits of 0.77 pg and 0.086 pg were achieved for bromine and iodine, respectively. These values correspond to 8.1 pg mL(-1) and 0.91 pg mL(-1) of the aqueous bromide and iodide ion concentrations, respectively, for a sampling volume of 95 microL. The relative standard deviations for eight replicate measurements were 2.2% and 2.8% for 20 pg of bromine and 2 pg of iodine, respectively. Approximately 25 batches were vaporizable per hour. The method was successfully applied to the analysis of various certified reference materials and practical situations as biological and aqueous samples. There is further potential for the simultaneous determination of fluorine and chlorine.  相似文献   

15.
A forced degradation study on glibenclamide was performed under conditions of hydrolysis, oxidation, dry heat, and photolysis and a high-performance column liquid chromatographic-ultraviolet (HPLC-UV) method was developed to study degradation behavior of the drug under the forced conditions. The degradation products formed under different forced conditions were characterized through isolation and subsequent infrared/nuclear magnetic resonance/mass spectral analyses, or through HPLC/mass spectrometric (HPLC/MS) studies. The drug degraded in 0.1 M HCI and water at 85 degrees C to a major degradation product, 5-chloro-2-methoxy-N-2-(4-sulfamoylphenyl)ethyl]benzamide (III), and to a minor product, 1-cyclohexyl-3-[[4-(2-aminoethyl)-phenyl]sulfonyl]urea (IV). Upon prolonged heating in the acid, the minor product IV disappeared, resulting in formation of 5-chloro-2-methoxy-benzoic acid (II) and an unidentified product (I). Heating of the drug in 0.1 M NaOH at 85 degrees C yielded II and IV as the major products and I and III as the minor products. The drug and the degradation products formed under different conditions were optimally resolved on a C18 column using ammonium acetate buffer (0.025 M, pH 3.5)-acetonitrile (45 + 55) mobile phase at a flow rate of 0.6 mL/min, with detection at 230 nm. The method was validated for linearity, precision, accuracy, and specificity. Limit of detection (LOD) and limit of quantitation (LOQ) values were also determined. The method could be successfully applied for simultaneous quantification of glibenclamide and the major product, III. The response of the method was linear in a narrow [0.4-10 micro/mL, correlation coefficient (r2) = 0.9982] and a wide (0.4-500 microg/mL, r2 = 0.9993) concentration range for glibenclamide, and in the concentration range of 0.025-50 microg/mL (r2 = 0.9998) for III. The method proved to be precise and accurate for both glibenclamide and III. It was specific for the drug and also selective for each degradation product, and LOQ values for the drug were 0.1 and 0.4 microg/mL, whereas those for III were 0.010 and 0.025 microg/mL, respectively.  相似文献   

16.
A new method for the determination of nine haloacetic acids (HAAs) with ion chromatography (IC) coupled to inductively coupled plasma mass spectrometry (ICP-MS) was developed. With the very hydrophilic anion-exchange column and steep gradient of sodium hydroxide, the nine HAAs could be well separated in 15 min. After suppression with an ASRS suppressor that was introduced in between IC and ICP-MS, the background was much decreased, the interference caused by sodium ion present in eluent was removed, and the sensitivities of HAAs were greatly improved. The chlorinated and brominated HAAs could be detected as 35ClO and 79Br without interference of the matrix due to the elemental selective ICP-MS. The detection limits for mono-, di-, trichloroacetic acids were between 15.6 and 23.6 microg/l. For the other six bromine-containing HAAs, the detection limits were between 0.34 and 0.99 microg/l. With the pretreatment of OnGuard Ag cartridge to remove high concentration of chloride in sample, the developed method could be applied to the determination of HAAs in many drinking water matrices.  相似文献   

17.
An ultraviolet spectrophotometric method was validated for total flavonoid quantitation, as rutin equivalents, present in the Trichilia catigua Adr. Juss (Meliaceae) and Ptychopetalum olacoides Bentham (Olacaceae) commercial extract. Parameters as linearity, interval (range), specificity, estimated limit of detection (LOD, microg/mL), estimated limit of quantitation (LOQ, microg/mL), recovery (R, %), precision or relative standard deviation (RSD, %), and accuracy (E, %) were established. The analytical method was validated according to the experimental results: correlation coefficient (r = 0.9997); interval (RSD = 0.15-0.47%; E = 98.98-101.24%); specificity to total flavonoids quantitation, as rutin equivalents, at wavelength 361.0 nm; LOD = 0.09 microg/mL and LOQ = 0.27 microg/mL; R = 99.36-102.14%; adequate intra- and interrun precision (0.30-0.49% and 0.31-0.81%), and intra- and interrun accuracy (100.60-102.38% and 98.58-100.38%).  相似文献   

18.
A general approach, still few exploited so far and never associated with microbore-LC, consisting of detection of various lipid classes (i.e. phospholipids, triglycerides, ceramides and glycosphingolipids) by non-covalent association with 1,6-diphenyl-1,3,5-hexatriene (DPH) fluorescence probe is developed. This mode of detection was coupled with non-aqueous reversed-phase microbore-LC (C18) by using classical post-column fluorescence detection. The classical LC system was first adapted to microbore-chromatography (internal diameter 1 mm) without apparatus miniaturization of the solvent delivery system and the detection cell. For this purpose, the detection parameters (probe concentration, post-column flow rate, post-column reactor length and post-column system temperature) were optimized by a central composite design (CCD) using a mixture of phosphatidylcholine (PC) species as a lipid model and DPH (lambda(ex) = 350 nm, lambda(em) = 430 nm) as a fluorescence probe. The optimal conditions of detection for the various molecular species of PC were determined for a DPH concentration of 3.35 micromol/L, a post-column flow rate of 0.5 mL/min, a reactor length of 1.4 m and a temperature of 35 degrees C. The fluorescence response was linear over a wide range of PC species from 5 microg/mL to 100 microg/mL and the lower limit of detection (signal/noise = 3) was about 1 microg/mL, that is equivalent to evaporative light scattering detection (ELSD). Others molecular species of various classes of lipids, i.e. triglycerides, ceramides and glycosphingolipids were also easily detected. Thus, this study demonstrated the versatility of the proposed system of detection which was shown to be sensitive, easy to perform, non-destructive and allowed, in contrast to ELSD, for a linear response with various polarity lipid classes.  相似文献   

19.
An accurate, simple, reproducible, and sensitive HPLC method was developed and validated for the simultaneous determination of atorvastatin calcium, ezetimibe, and fenofibrate in a tablet formulation. The analyses were performed on an RP C18 column, 150 x 4.60 mm id, 5 pm particle size. The mobile phase methanol-acetonitrile-water (76 + 13 + 11, v/v/v), was pumped at a constant flow rate of 1 mL/min. UV detection was performed at 253 nm. Retention times of atorvastatin calcium, ezetimibe, and fenofibrate were found to be 2.25, 3.68, and 6.41 min, respectively. The method was validated in terms of linearity, precision, accuracy, LOD, LOQ, and robustness. The response was linear in the range 2-10 microg/mL (r2 = 0.998) for atorvastatin calcium, 2-10 microg/mL (r2 = 0.998) for ezetimibe, and 40-120 microg/mL (r2 = 0.998) for fenofibrate. The developed method can be used for routine quality analysis of the drugs in the tablet formulation.  相似文献   

20.
A rapid and sensitive method was developed for the screening, quantification and confirmation of ethyl glucuronide (EG) and ethyl sulfate (ES) as biomarkers for alcohol administration to racehorses using liquid chromatography coupled on-line with triple quadrupole tandem mass spectrometry. Urine sample aliquots (0.1 mL) were pre-treated by protein precipitation. Separation of EG and ES was achieved on an Ultra PFP column. Isocratic elution with a flush step was performed using 0.1% formic acid in water (A) and 0.1% formic acid in acetonitrile (B). Analysis was performed by negative electrospray ionization in multiple reaction monitoring mode. The retention times for EG and ES were 1.7 +/- 0.30 and 3.4 +/- 0.30 min, respectively. The internal standard used was d(5)-ethyl glucuronide with a retention time of 1.7 +/- 0.30 min. The entire separation was completed in <5 min. The limit of detection (LOD) and of quantification (LOQ) for both analytes were 100 ng/mL (S/N > or =3) and 500 ng/mL, respectively. The limit of confirmations (LOC) for EG and ES were 500 ng/mL and 1.0 microg/mL, respectively. The assay was linear over a concentration range of 0.5-100 microg/mL (r(2) > 0.995). Intra- and inter-day accuracy and precision were less than 15%. The analytes were stable in urine for 24 h at room temperature, 10 days at 4 degrees C and 21 days at -20 degrees C and -70 degrees C. Ion suppression or enhancement due to matrix effect was negligible. The measurement uncertainty was <14% for EG and <25% for ES. This method was successfully used for the quantification of EG and ES in urine samples following alcohol administration to research horses and for screening and confirmation of EG and ES in urine samples obtained from racehorses post-competition. The method is simple, rapid, inexpensive, and reliably reproducible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号