首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and rapid method is described for the quantitative extraction and determination of Cd and Pb in mussel tissue (Mytilus edulis). The method is based on the quantitative ultrasound-assisted extraction (i.e. sample mass at mg level) of the two metals using diluted nitric acid as extractant. The extraction procedure is carried out in autosampler cups of the graphite furnace (typically, less than 20 mg). A two-level full factorial design (24) was applied to optimize the variables influencing the ultrasound extraction process. These variables were: extraction time, ultrasound amplitude, nitric acid concentration and particle size. Optimization results showed that acid concentration and particle size were the more significant variables. Determination of Cd and Pb in extracts obtained after ultrasound treatment was carried out by Electrothermal Atomic Absorption Spectrometry. The method was validated by statistically comparing the metal contents found with the certified ones corresponding to the BCR 278 mussel tissue. No significant differences were observed for P = 0.05. LODs for Cd and Pb in mussel tissue were 0.019 and 0.37 μg g–1. RSDs values (corresponding to between-batch precision for n = 5) were 2.2 and 6.7% for Cd and Pb, respectively. The method was applied to measure the contents of Cd and Pb in mussels used as pollution bioindicators from the Galician coast (Ria de Vigo, Spain). Received: 30 June 1998 / Revised: 17 September 1998 / Accepted: 22 September 1998  相似文献   

2.
The uptake of Cr, Mn, Ni, Cu, Zn, Cd and Pb in soft tissue of Perna perna mussels and their shells has been studied in aquarium experiments in which mussels were exposed for 30 or 60 days to seawater spiked with different concentrations of these contaminants (125 and 500 μg L−1). Tissue samples were analyzed after acid digestion by conventional solution nebulization ICP–MS. Laser ablation ICP–MS was used for the quantitative determination of trace elements in different areas of the corresponding shells. With the exception of Mn and Zn, all other elements studied showed a significant concentration enhancements in soft tissue, with the magnitude of this enhancement following the order: Cr > Ni > Cd > Cu > Pb. A corresponding increase in most contaminants, although less pronounced, was also observed in the newly formed growth rings of mussel shells, contributing to the validation of Perna perna mussel shell as a bioindicator of toxic elements.  相似文献   

3.
A selective method of elution for the extraction of heavy metals from sea waters on a chelating resin.The extraction of heavy metals in sea water with Chelex 100 prior to their determination by atomic absorption spectrometry (a.a.s.) with electrothermal atomization is discussed. Maximum retention of heavy metals is not obtained with the resin in the H+ form, because it is gradually transformed in contact with sea water by the fixation of alkali and alkaline-earth cations which are eluted simultaneously with the heavy metals and interfere during a.a.s. The separation of heavy metals is quantitative on Chelex 100 in the Ca2+ form; treatment with dilute acetic acid (1 + 99) eliminates the alkali and alkaline-earth metals fixed on the resin before elution or the heavy metals. Elution with 1 M nitric acid gives simultaneous and quantitative recovery of Cu, Pb, Ni, Zn, Cd and Co; intermediate elution with 0.01 M nitric acid isolates Zn, Cd and Co from Cu and Pb, which are subsequently eluted with 1 M nitric acid.  相似文献   

4.
The contents of V, Cr, Co, Ni, Cu, Ga, Rb, Cd, Ba, and Pb in the soft tissue of blue mussel (Mytilus edulis) were determined by a high resolution inductively coupled plasma mass spectrometry (HR-ICPMS) method. Sample digestions were performed in closed microwave vessels using nitric acid and hydrogen peroxide. Using HR-ICPMS it is possible to resolve the analytical peaks from otherwise interfering polyatomic ions with a mass resolution setting of 4000 (Cr, Ni, Cu). The proposed method was validated using a mussel tissue reference material (NIST SRM 2974). The proposed method was applied to real samples of blue mussel from seven sites in the inlet “Limfjorden”, Denmark, and the levels of trace elements found were compared with the levels found in an earlier study. For the mussel samples large inter-regional differences in trace element concentrations in the tissues were recorded. The mussels from the different sites could be separated using principal component analysis (PCA). Comparison with the levels of trace elements in mussels found in 1982 showed that the trace elemental contamination has increased during the last 15 years. From the data obtained, mussel tissue appears to be good bio-indicator for identification of coastal areas exposed to metallic contaminants.  相似文献   

5.
An ultrasound-assisted solvent extraction procedure has been optimised to speed up total polycyclic aromatic hydrocarbons (T-PAHs) extraction from mussel soft tissue. The T-PAHs releases have been evaluated by spectrofluorimetry (excitation and fluorescence emission wavelengths of 300 and 382 nm, respectively, and using chrysene as calibrant). Variables such as sonication time, ultrasound frequency, n-hexane volume, dichloromethane volume, number of repeated extractions with n-hexane and number of repeated extraction with dichloromethane were simultaneously studied by applying a Plackett-Burman design (PBD) approach. Results showed that ultrasound frequency and n-hexane and dichloromethane volumes were statistically significant variables (confidence interval of 95%). These last two variables were finally optimised by using central composite designs (CCD), yielding optimum n-hexane and dichloromethane volumes of 2.5 and 6.5 ml, respectively. The lowest T-PAHs releasing at high ultrasound frequency (35 kHz) led to choice the lowest ultrasound frequency (17 kHz) to perform the extraction. Variables such as sonication time and number of repeated extraction with n-hexane or dichloromethane were statistically non-significant and they were fixed at 10 min and the extraction with n-hexane and dichloromethane were performed once. The limit of detection was 0.021 μg g−1 (referred to dried mass), the repeatability of the overall method was 4.7% (n = 9) and the analytical recoveries were between 98 and 105%. The proposed method was finally applied to 16 mussel samples (Mytilus galloprovincialis) from Ría de Arousa estuary (Galicia, northwest Spain).  相似文献   

6.
《Analytical letters》2012,45(13):2101-2110
A solid phase extraction (SPE) technique using an activated carbon column was developed for the extraction of trace levels of Cd, Ni, Pb, and Zn in aqueous solution which was obtained from the digestion of fish tissue. Ammonium pyrrolidin edithiocarbamate (APDC) was used to form metallic complexes that could be retained in a SPE column which was packed with powder activated carbon. The analytes were eluted from the column by nitric acid in acetone. The metal concentrations were determined by flame and graphite atomic absorption spectroscopy. The effects of flow rate, APDC concentration, and pH were investigated. The proposed method was validated. The method detection limits were 11.7, 13.4, 10.1, and 25.3 µg kg?1 for Cd, Ni, Pb, and Zn, respectively. The recoveries and RSDs were within the range of 81.9–101.1% and 0.6–6.0%, respectively. The method has potential merit for heavy metal determination in fish tissue.  相似文献   

7.
Three different ultrasonic-based sample treatment approaches, the automated ultrasonic slurry sampling, the ultrasonic assisted acid solid-liquid extraction (ASLE) and the enzymatic probe sonication (EPS) were compared and discussed for the determination of Cd and Pb by ET-AAS in biological reference materials. The sample mass chosen to perform the analysis was 10 mg and the liquid volume was 1 ml of nitric acid 1 M. The best results were obtained with the slurry procedure with which it was possible accurate and precise determination of the Cd and Pb content in four of the five reference materials studied. Optimum performance (total metal extraction) of ASLE assisted by ultrasound for Cd was only achieved in two of the four materials assessed whereas total Pb recovery was only possible in three of the five samples. Total extraction with the enzymatic probe sonication was only obtained for Cd in oyster tissue. Neither ASLE nor EPS were able to extract Cd or Pb from spruce needles. Pb concentration obtained after EPS was found to be highly dependent from sample centrifugation speed and time.  相似文献   

8.
An on-line solid phase micro-column extraction and determination system for trace Cd and Pb in nuclear fuel grade uranium compounds was established. The preconcentration of trace elements Cd and Pb from uranium compounds was achieved by adsorbing Cd and Pb on CL-7301 resin in hydroiodic acid media, while the uranyl ion passed through. The method coupled with flame atomic absorption spectrometry (FAAS) was applied to analysis trace Cd and Pb in real samples. The preconcentration factors obtained by this method were 320 and 180 each for Cd and Pb, respectively. Under the optimized conditions, the detection limits corresponding to three times the standard deviation of the blank were found to be 0.13 ng·mL−1 and 0.37 ng·mL−1 for Cd and Pb, respectively. The relative standard deviation (RSD) and the recoveries of standard addition (spiked with 1–5 ng of Cd and Pb) were of <5% (n = 10) and 96.2%–102.3%, respectively. Precision was also evaluated and found to be ≤4.3% (N = 11). The proposed method was successfully used for the determination of trace Cd and Pb in commercially available uranium compounds (e.g., uranyl acetate and triuranium octoxide).  相似文献   

9.
A three factor Doehlert design was applied to optimize the extraction of elements in marine invertebrate samples (oyster, mussel and clam) using centrifugation with diluted acids. The factors were: concentration of acid mixture (HCl + HNO3 + H3CCOOH; 1–3 mol L− 1), centrifugation time (10–40 min), and rotation velocity (6000–10,000 rpm). In order to evaluate the ultrasound effect on the extraction of trace metals, a portion of the certified oyster tissue sample (NIST 1556b; 0.250 g) was sonicated for 15 min and then the solution was centrifuged at the optimized conditions. The optimized procedure was then applied to nine marine invertebrate samples (oysters, clams and mussels) collected at Todos os Santos Bay, Bahia, Brazil. The optimized condition of the developed method was: 20 min of centrifugation at 9000 rpm using the acid mixture 1.0 mol L− 1. The effect of sonication prior centrifugation was very variable, but it promoted a significant increase in the extraction (12 to 44%) of some trace elements. Moreover, the combination of the centrifugation with sonication offered other advantages, such as improvement of the precision and accuracy, both demonstrated using the oyster tissue reference sample. The results of major and trace elements in marine invertebrate samples showed that elements such us Cd and Cu in oyster samples and Zn in mussel and clam samples were above recommendations, suggesting that its consumption may impose health risks.  相似文献   

10.
Two single-step extraction procedures validated by BCR, extraction with 0.43 mol dm−3 acetic acid and 0.05 mol dm−3 EDTA, are used for assessing bioavailable species of Pb and Cd in soils. After an extensive study of interferences of humic substances and using standard additions procedures, the extractable contents of Pb and Cd have been determined by DPASV directly in soil extracts with a good reproducibility (RSD varied from 1.0 to 7.9 %). Pb(II) and Cd(II) were released from complex in EDTA extracts by pH adjustment to 1 with 1 mol dm−3 HCl. The results were compared with those obtained with atomic absorption spectrometry and indicated reasonable agreement of both methods. Exchangeable forms represented 0.2 to 3.3 % and 13.0 to 63.6 % of total content of Pb and Cd in soils, respectively. EDTA extraction released from soils 7.9 to 29.9 % and 33.5 to 59.6 % of total content of Pb and Cd, respectively.  相似文献   

11.
Focused microwave-assisted digestion and ultrasound leaching have been applied for the extraction of Pb, Cd, Cr, Cu, Fe, Zn, Ca, and Mg from raw meat. Semimembranous muscle (SM) of raw pig ham was used for optimizing both the digestion and extraction steps by multivariate approaches. The detection and quantification limits were 0.5 and 0.9 g kg–1 for Pb, 0.06 and 0.1 g kg–1 for Cd, 0.2 and 1.2 g kg–1 for Cr, 0.4 and 3 g kg–1 for Cu, 0.04 and 0.1 mg kg–1 for Fe, 0.012 and 0.017 mg kg–1 for Zn, 0.3 and 0.4 mg kg–1 for Ca, and 0.01 and 0.03 mg kg–1 for Mg. The precision, expressed as relative standard deviation (RSD), ranged between 2.5 and 9.6% for focused microwave-assisted digestion and between 3.5 and 10.6% for ultrasound leaching. The methods were then compared with a reference method and applied to a certified reference material (bovine muscle 184, from the BCR). The t-test, applied to the results obtained from focused microwave-assisted digestion, revealed that they are in agreement (p>0.01) with the certified and estimated values in the case of Pb, Cd, Cr, Cu, Fe, Ca, Mg, and Zn but not in that of Fe. In the case of ultrasound leaching, only the extraction of Pb, Cu, and Ca was quantitative. The method based on microwave digestion provides more accurate and precise results than ultrasound leaching. These new procedures have many advantages with regards to conventional methods, namely, reduction of the extraction time, simplification of the process, avoidance of chemical emissions to the atmosphere, and no losses of metals by volatilization.  相似文献   

12.
Continuous ultrasound-assisted extraction has been coupled with preconcentration and flame atomic absorption spectrometry for the determination of cadmium and lead in mussel samples. Experimental designs were used for the optimisation of the leaching and preconcentration steps. The use of diluted nitric acid as extractant in the continuous mode at a flow rate of 3.5 ml min−1 and room temperature was sufficient for quantitative extraction of these trace metals. A minicolumn containing a chelating resin (Chelite P, with aminomethylphosphoric acid groups) was proved as an excellent material for the quantitative preconcentration of cadmium and lead prior to their flame atomic absorption detection. A flow injection manifold was used as interface for coupling the three analytical steps, which allowed the automation of the whole analytical process. A good precision of the whole procedure (2.0 and 2.3%), high enrichment factors (20.5 and 11.8) and a detection limit of 0.011 and 0.25 μg g−1 for cadmium and lead, respectively, were obtained for 80 mg of sample. The sample throughputs were ca. 16 and 14 samples h−1 for cadmium and lead, respectively. The accuracy of the analytical procedures was verified by using a standard reference material (BCR 278-R, mussel tissue) and the results were in good agreement with the certified values. The method was successfully applied to the determination of trace amounts of cadmium and lead in mussel samples from the coast of Galicia (NW, Spain).  相似文献   

13.
A method for the determination of Ag, Cd, Cu, Pb and Tl in fuel alcohol by isotope dilution electrothermal vaporization inductively coupled plasma mass spectrometry (ID ETV-ICP-MS) is proposed. The analytes were separated in two groups: Ag and Cu were determined without modifier and Cd, Pb and Tl with the use of Pd as chemical modifier. The employed ETV operational conditions were pyrolysis temperature of 800 °C for Cd, Pb and Tl and of 900 °C for Ag and Cu and vaporization temperature of 2400 °C for both groups. Seven common, one with additive and one anhydrous fuel ethanol samples were analyzed. The spiked and reference isotopes were, respectively, 109Ag and 107Ag, 112Cd and 111Cd, 63Cu and 65Cu, 206Pb and 208Pb and 203Tl and 205Tl. The added amounts of the enriched isotope material were the same for all samples: 4.6 ng of 109Ag, 5 ng of 112Cd, 21.1 ng of 63Cu, 9 ng of 206Pb and 0.21 ng of 203Tl. The blank was bi-distilled ethanol, acidified with 0.3% (v/v) nitric acid, as the samples. The limits of detection (LODs) were calculated as three times the standard deviation of the concentrations in the blank (n = 10) and were, in μg L−1, for Ag: 0.02, for Cd: 0.08, for Cu: 0.1, for Pb: 0.05 and for Tl: 0.001. The obtained concentrations in the samples were in agreement with those obtained by external calibration (EC), according to the paired t-test. The isotope dilution (ID) showed to be a robust, fast and simple calibration technique for the analysis of fuel ethanol.  相似文献   

14.
The contents of V, Cr, Co, Ni, Cu, Ga, Rb, Cd, Ba, and Pb in the soft tissue of blue mussel (Mytilus edulis) were determined by a high resolution inductively coupled plasma mass spectrometry (HR-ICPMS) method. Sample digestions were performed in closed microwave vessels using nitric acid and hydrogen peroxide. Using HR-ICPMS it is possible to resolve the analytical peaks from otherwise interfering polyatomic ions with a mass resolution setting of 4,000 (Cr, Ni, Cu). The proposed method was validated using a mussel tissue reference material (NIST SRM 2974). The proposed method was applied to real samples of blue mussel from seven sites in the inlet "Limfjorden", Denmark, and the levels of trace elements found were compared with the levels found in an earlier study. For the mussel samples large inter-regional differences in trace element concentrations in the tissues were recorded. The mussels from the different sites could be separated using principal component analysis (PCA). Comparison with the levels of trace elements in mussels found in 1982 showed that the trace elemental contamination has increased during the last 15 years. From the data obtained, mussel tissue appears to be good bio-indicator for identification of coastal areas exposed to metallic contaminants.  相似文献   

15.
A dynamic ultrasound-assisted extraction step is proposed for the quantitative extraction of Cd and Pb from plant leaves prior to determination by electrothermal atomic absorption spectrometry (ETAAS). Beech leaves (a certified reference material—CRM 100—where the target analytes were not certified) were used for optimizing the extraction step by a multivariate approach. The samples (0.25 g) were subjected to dynamic ultrasound-assisted extraction with dilute nitric acid as extractant. The method was validated with a certified reference material BCR-062 (olive leaves) where both Cd and Pb are certified. The good agreement between the certified values and those found using the proposed method demonstrates its usefulness. The repeatability was 2.0 and 0.9% and the within-laboratory reproducibility was 7.1 and 2.8% for Cd and Pb, respectively. The precision of the method, together with its efficiency, rapidity, low cost and environmental acceptability makes it a good alternative for the determination of trace metals from plant material.  相似文献   

16.
A systematic evaluation of different variables affecting the enzymatic hydrolysis of mussel soft tissue by five enzymes, three proteases (pepsin, pancreatin and trypsin), lipase and amylase, has been carried out for the determination of trace elements (As, Al, Cd, Cr, Cu, Fe, Mn, Ni, Pb and Zn) by inductively coupled plasma-atomic emission spectrometry (ICP-AES). Enzymatic hydrolysis methods offers advantages such as a less species alteration, safer laboratory conditions and a less contaminant wastes. The enzymatic hydrolysis was performed in an incubation camera Boxcult with orbital and horizontal shaker. Variables affecting the enzymatic hydrolysis process were simultaneously studied by applying a Plackett-Burman design (PBD). For a confidence interval of 95%, the significant factors for all enzymes and for most of the elements were the pH, the incubation temperature and the ionic strength. These significant factors were optimized later by using a central composite design (CCD), which gave optimum conditions at pH of 1, incubation temperature of 37 °C and ionic strength fixed by sodium chloride at 0.2 M when using pepsin. For pancreatin, trypsin, lipase and amylase there were found two different optimum condition sets. The first one involves the use of a 0.5 M phosphate buffer (ionic strength), at a pH of 6 and at an incubation temperature of 37 °C, which allows the quantitative extraction of Al, Cr, Mn, Pb and Zn. The second conditions set employees a 0.1 M phosphate buffer (ionic strength), a pH of 9 and an incubation temperature at 37 °C, and it results adequate to extract As, Cd, Cu, Fe and Ni. Analytical performances, repeatability of the over-all procedure and accuracy, by analyzing DORM-1, DORM-2 and TORT-1 certified reference materials, were finally assessed for each enzyme. Good agreement with certified values has been assessed for most of the elements (As, Cd, Cr, Cu, Mn, Ni, Pb and Zn) when using trypsin, pepsin and/or pancreatin, except for Cd and Pb in DORM-1 and DORM-2 because of the certified contents in such certified reference materials are lower than the limit of detection (0.10 and 0.16 μg g−1 for Cd and Pb, respectively, for the use of trypsin).  相似文献   

17.
A solid phase extraction system for separation and preconcentration of trace amounts of Pb(II), Ni(II), Cd(II) and Cu(II) is proposed. The procedure is based on the adsorption of Pb2+, Ni2+, Cd2+ and Cu2+ ions on a column of 1-(2-pyridylazo)-2-naphthol (PAN) immobilised on surfactant-coated clinoptilolite prior to their determinations by Flame Atomic Absorption Spectroscopy (FAAS). The effective parameters including pH, sample volume, sample flow rate and eluent flow rate were also studied. The analytes collected on the column were eluted with 5 mL of 1 mol L?1 nitric acid. A concentration factor of 180 can be achieved by passing 900 mL of sample through the column. The detection limits (3 s) for Cd, Cu, Pb and Ni were found to be 0.28, 0.12, 0.44 and 0.46 µg L?1, respectively. The relative SDs at 10 µg L?1 (n = 10) for analytes were in the range of 1.2–1.4%. The method was applied to the determination of Pb, Ni, Cd and Cu in water samples.  相似文献   

18.
A simple, fast and reliable method is described for the quantitative extraction of Sb and Co from inorganic environmental matrices containing variable amounts of silicates prior to their determination by electrothermal-atomic absorption spectrometry. The method is based on the ultrasound-assisted extraction of both elements using the mixture 20% v/v HF + 20% v/v HNO3 as extractant. The extraction procedure was carried out in closed Eppendorf vials immersed in a cup-horn sonoreactor for 20?min. Once extraction has been accomplished, the supernatant liquid is separated from the solid phase and subsequently transferred into the autosampler of the instrument. A two-level full factorial design (24) was applied for screening optimisation of the variables influencing the ultrasonic extraction. These variables were: sonication time; amplitude of the ultrasound energy; nitric and hydrofluoric acid concentrations. MLDs were 0.20 and 0.06?µg?·?g?1 for Sb and Co, respectively. Between-batch precision values, expressed as relative standard deviations (n?=?3), were less than 5.5 and 9.6% for Sb and Co, respectively. The method was evaluated using a wide variety of inorganic certified reference materials, such as SRM 2702 (Marine Sediment), SRM 2782 (Industrial Sludge), BCR 176R (Fly Ash), SRM 1633b (Coal Fly Ash) SRM 2710 (Montana Soil) and SRM 2711 (Montana Soil).  相似文献   

19.
We have immobilized iminodiacetic acid on mesoporous Fe3O4@SiO2 microspheres and used this material for efficient and cost effective method of magnetic solid phase extraction (SPE) of trace levels of Cd, Mn and Pb. The microspheres were characterized by infrared spectroscopy, scanning electron microscopy and transmission electron microscopy. The loaded microspheres can be easily separated from the aqueous sample solution by applying an external magnetic field. The effects of pH, sample volume, concentration and volume of eluent, and of interfering ions were investigated in detail. The method has detection limit of 0.16, 0.26 and 0.26?ng?L?1 for the ions of Cd, Mn and Pb, respectively, and the relative standard deviations (RSDs, c?=?1???g?L?1, n?=?7) are 4.8%, 4.6% and 7.4%. The method was successfully applied to the determination of these metals in biological and environmental samples using ICP-MS. Two certified reference materials were analyzed, and the results coincided well with the certified values.
Figure
Mesoporous Fe3O4@SiO2@IDA magnetic particles for fast and selective magnetic solid phase extraction of trace Cd, Mn and Pb from environmental and biological samples followed by inductively coupled plasma mass spectrometry detection.  相似文献   

20.
The determination of Pb(II) and Cd(II) in different sample matrices, including drinking water, distilled spirits and fruit wine, was carried out by flame atomic absorption spectrometry (FAAS) after pre-concentration using homogeneous liquid-liquid extraction (HLLE). First, the HLLE method was optimised with lead diethyldithiocarbamate (Pb-DDTC) complex which was extracted with a perfluorooctanoate anion (PFOA?) dissolved in lithium hydroxide under acidic conditions. The optimum extraction conditions, using 0.01 M DDTC, 0.05 M PFOA?, 3 M HCl and 1 mL of 30 vol. % acetone, were obtained. The Pb-DDTC complex in the nitric acid digest of the samples (50–150 mL) was extracted quantitatively into a drop of 100 μL of sediment phase. The sediment phase dissolved in 1 vol. % HNO3 with at least 3–5 mL of the final volume was then determined by FAAS, affording a pre-concentration factor of 10–50. Hence, the HLLE method afforded an increase in both sensitivity and selectivity for the metal determination by conventional FAAS, resulting in ultra-trace level detection of Pb(II) in all samples analysed (drinking water, 9.2–23 ng mL?1; distilled spirits, 23–50 ng mL?1; fruit wine, 24–53 ng mL?1). In addition, the proposed method could successfully be applied to Cd(II) determination in these samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号