首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Experiments have been carried out to study the ‘heavy fragments’ emitted at wide angles in the interaction of 3.65 A GeV 16O ions with a thick Cu target, using a stack of CR-39 track detectors. Diametric distribution in a stack registering 16O-beam halo are compared with diameters observed in a stack placed downstream at an angle of 25°. There is a strong indication that the heavy fragments are scattered at large angles.  相似文献   

2.
As a frame work of the study for the latent track size measurement using atomic force microscope, we have measured the minute etch pits and the extremely small amount of bulk etch of CR-39 at the beginning of chemical etching, and obtained its growth curves in nanometer dimensions. The pieces of CR-39 were exposed to 6 MeV/nC and Fe ions with normal incidence angle and were etched in 70°C 7 N NaOH solution for 0.5,1,2,3,5 min. The diameters of latent track were estimated to be 17 nm for Fe ions and 8 nm for C ions, respectively. These values are comparable to the experimental data on the average ‘track core diameters’ that have been obtained by various experimental techniques.  相似文献   

3.
Recently, several new etchants have been reported for CR-39 detector (Molten Ba(OH)2. 8H2O as an etchant for CR-39 detector, Radiat. Meas. 37 (2003) 205; Discovery of new etchants for CR-39 detector, Radiat. Meas. (2004)). We have made further progress in this direction and have unveiled two more new etchants which are reported in this article. CR-39 detectors were irradiated with fission fragments and alpha particles from a thin 252Cf disc source. The irradiated detectors were then etched in our newly introduced etching solutions as well as in conventionally used 6 M NaOH aqueous solution at 70 degrees C. The newly prepared etching solutions included NaOH dissolved in methanol and NaOH dissolved in methanol + water. Optimum values of NaOH concentration in methanol as well as in methanol + water were determined. Optimum etching temperatures were also determined for both the above-mentioned etchants. From fission and alpha track diameters, bulk etching rate (VB), track etching rate (VT) and etching efficiency (eta) were determined and compared with that obtained for 6 M NaOH at 70 degrees C. Both the newly introduced etchants were found more efficient than the conventionally used 6 M aqueous NaOH (64%) at 70 degrees C and have relatively much smaller etching time.  相似文献   

4.
We studied the track response for the copolymer of CR-39 monomer with N-isopropylacrylamide (NIPAAm) as well as etching properties. It was found that copoly (CR-39/NIPAAm/Naugard 445) composed in wieght ratio of 99/1/0.01 is highly sensitive to low LET particles in the region below 10 keV/μm of LET and able to record normally incident particles of LET down to 1.5 keV/μm, recording protons up to the energy of 27 MeV. These results were compared with the responses for two types of CR-39 detectors containing a small quantity of antioxidant. The threshold energy proton registration is discussed.  相似文献   

5.
The effect of infrared radiation on the etching characteristics of CR-39 plastic track recorder has been studied. CR-39, which is commonly employed in cosmic rays studies is found to be affected by IR radiations. The changes in the bulk etch rate, in the track etch rate and in etching efficiency due to infrared radiation exposure of CR-39 are discussed on the basis of scission and cross linking during infrared exposure.  相似文献   

6.
This paper reports results of track registration for fast particles from the hot spot sparked inside a metal target. CR-39 track detectors placed in the ion pinhole camera, a magnetic analyzer, and Thomson-type mass-spectrometer in order were used to obtain images of the hot spot and to determine spectra of the fast particles. Using track detectors in the pinhole camera, we have obtained specific split images. The “average etch rate ratio versus track length” locus for track sample groups is depicted by means of squared diameters asymptotic method. Our analysis shows the majority of tracks belong to hydrogen nuclei. The track loci for the detectors from the pinhole or analyzers turn out to be split into two parallel streaks that have been interpreted as a proton–deuteron doublet. Data obtained using the Thomson analyzer clearly demonstrate the equal numbers of protons and deuterons for some parallel parabola sections.  相似文献   

7.
After reporting the excellent etching properties of molten Ba(OH)2 8H2O as an etchant, we now report some more new and efficient etchants for CR-39 detector. CR-39 detectors were irradiated with fission fragments and alpha particles with a thin 252Cf source. The irradiated detectors were etched in a number of our newly introduced etching solutions as well as in conventionally used 6 M NaOH at 70 degrees C. The newly prepared etching solutions included NaOH/ethanol and NaOH/1-propanol. Processing conditions were optimized for these etchants. From fission and alpha track diameters, bulk etching velocity (VB), track etching velocity (VT), etching efficiency (eta) and their activation energies were determined and compared with that obtained for 6M NaOH at 70 degrees C.  相似文献   

8.
A review was given for our recent studies on the latent tracks in CR-39 nuclear track detector. The radial size of track core has been determined through UV spectral measurements combined to the model of track overlapping and by AFM observations of slightly etched detectors. The track core radius was found to be about a few nano-meters and almost proportional to the cubic root of stopping power. As a control study, the etching properties of CR-39, irradiated by low-LET radiation, has been examined. The observed depth dependence and dose-rate dependence of the bulk etch rate of the irradiated CR-39 were explained that the damage formation process was governed by the reaction between the radiation induced radicals and the oxygen supplied from the air. This indicated that latent tracks in CR-39 are produced through local radiation induced oxidation process along the ion paths. Studies on vibration spectra, near-IR, FT-IR and Raman spectra, of CR-39 have also been carried out to estimate the chemical structure of the latent tracks. The creation of OH group in irradiated CR-39 has been confirmed.  相似文献   

9.
The samples of CR-39(DOP) and SR-90 polymer track detectors have been exposed to -particles from 241Am source in an exposure unit. The temperature of the detectors during irradiation has been varied from −30°C to 70°C. These exposed samples have been etched in 6.25 N NaOH solution at 60°C for various etching times. The variation of sensitivity of these detectors as a function of registration temperature has been studied. It has been observed that at the fixed registration temperature, the sensitivity of SR-90 is more than CR-39(DOP) polymer track detector. However, the enhancement in sensitivity with the decrease in registration temperature is more pronounced in case of CR-39(DOP) than SR-90.  相似文献   

10.
Systematic measurements of swelling of CR-39 nuclear track detector (NTD) due to irradiation with fission fragments and alpha particles over a wide range of fluences from 252Cf are presented here. Precisely designed and optimized exposure and chemical etching experiments were employed to unfold the structure of radiation induced surface damage. Delays in the startup of the chemical etching of latent tracks in low radiation fluence detectors are measured and are found to contain important information about structure of the surface damage. Simple atomic scale pictures of radiation induced surface damage and its chemical etching are developed using measurements of radiation induced swelling of CR-39 detectors and nuclear track parameters. The computer code SRIM2010 was utilized for the calculations of basic features of latent tracks of fission fragments and alpha particles in CR-39. Another computer code TRACK_VISION was used to compute parameters of etched tracks. Computations and experimental findings in the paper coherently compose a realistic picture of radiation damage.  相似文献   

11.
CR-39 is a highly sensitive etched track detector for neutron monitoring and dosimetry applications but its dose equivalent response is strongly direction dependent with respect to the incident neutrons. This is considered to be a major drawback for their use. In the present study, an attempt has been made to develop a pyramid shaped dosimeter, which consists of polyethylene material of thickness 1 mm with the provision to hold three CR-39 films at an angle of 35° to each other. The response of CR-39 in this configuration under optimum electrochemical etching at elevated temperature have been found nearly angular independent and therefore the dosimeter can be used for neutron monitoring, i.e. personnel as well as area monitoring.  相似文献   

12.
Total internal reflection technique is examined critically for the measurement of apex angle of the prism. Recognition of the critical boundary completely specifies the apex angle ‘A’ of the prism by keeping constant the ratio of refractive index of sample fluid (n1=1.4) to that of glass (n2=1.7). Recording of observations in the laboratory is dependent upon whether the apex angle ‘A’ of prism is greater than or less than or equal to critical angle ‘rc’. The minimum value of error function ‘χ’ in the proximity of Abbe angle explain the choice of Abbe type instruments and shown invariant by relating positive ‘+’ and the negative angle of emergence ‘’. Using ray-tracing technique, an expression for the length of the critical boundary ‘l’ is derived and is shown as a measure of the apex angle ‘A’ of the prism.

The choice of the realistic grazing condition leads us to two turning points for which error function ‘χ’ is minimal and yields appropriate option of the measurement of apex angle ‘A’ of the prism. It is further shown that the small error ‘ζ’ crept in the apex angle ‘A’ of the prism can lead to a significant error in the design of Pulfrich type instruments.

Experimental measurements are in-line with the predictions made.  相似文献   


13.
Dating quaternary sediments by thermoluminescence (TL) or optically stimulated luminescence (OSL) calls for a detailed knowledge of the luminescence of feldspars. TL of the various alkali feldspars ((K, Na) Si3AlO8) display many common features, and some of these cause great difficulties for dating. After long storage following ionizing irradiation, the TL of most alkali feldspars is known to fade away by “anomalous fading”, which is incompatible with dating. This effect had been attributed to tunnel recombination. Following irradiation, a very intense tunnelling afterglow is observed at temperatures down to liquid nitrogen, in accordance with the observed rate of fading. This emission has a Gaussian spectrum entirely in the infrared (IR) with a maximum at 1.7 eV. It displays an important thermal quenching from 77 to 300 K. Its intensity is related with the ‘disorder’ of the crystal lattice. At higher temperatures, in TL proper, two emission bands can be separated. One is the well-studied complex visible emission, distributed over the spectral region from UV to orange, but mostly ‘blue’. The other is the ‘infrared’ band already observed at lower temperatures, which is attributed to Fe3+ ions. These two bands are clearly separated, with the spectral maxima, respectively, below and above 600 nm. They have also different kinetics, the glow peaks temperatures are different. But these two different bands are also coupled in many ways, they have parallel growth and fading. With ‘disordered’ feldspars, the ‘blue’ emission displays anomalous fading, which is stronger than that of the ‘infrared’. The infrared emission is more stable, which may be interesting for the purpose of dating.  相似文献   

14.
A neutron personal dosemeter using CR-39 as a detector and hydrogenated materials as proton converters for fast neutron detection plus an air layer for thermal neutron detection is being developed in our laboratory. To increase the CR-39 response to thermal neutrons, the air converter was substituted with Nylon in some dosemeters. Several dosemeters with these two configurations were mounted on a water-filled phantom and exposed under different incidence angles (0, 30 and 60) to: (i) Three ISO neutron sources (241Am–Be, bare 252Cf and moderated 252Cf with Cd shielding), and (ii) two realistic neutron sources (SIGMA and moderated 252Cf) at the IRSN (Cadarache) facilities. The irradiated detectors were electrochemically etched and evaluated in order to determine their dose equivalent response in terms of Hp(10,α). The results obtained are compared to those obtained from Monte Carlo simulations using the MCNPX code.  相似文献   

15.
In this work, we have studied the effect of the radiation damage caused by the incident particles on the activation energy of etching for CR-39 samples. The damage produced by the incident particle is expressed in terms of the linear energy transfer (LET). CR-39 samples from American Acrylic were irradiated to three different LET particles. These are N (LET200 = 20 KeV/μm) as a light particle, Fe (LET200 = 110 KeV/μm) as a medium particle and fission fragments (ff) from a 252Cf source as heavy particles. In general the bulk etch rate was calculated using the weight difference method and the track etch rate was determined using the track geometry at various temperatures (50–90 °C) and concentrations (4–9 N) of the NaOH etchant. The average activation energy Fb related to the bulk etch rate vb was calculated from ln vb vs. l/T. The average activation energy Et related to the track etch rate vt was estimated from ln vt vs. l/T. It is shown that activation energy of etching is a constant value for CR-39 detector where Et was found to be independent on the damage produced by the incident particle.  相似文献   

16.
We present the results of a study of the magnetic switching properties of arrays of narrow Co(1 0 0) epitaxial ring magnets, with outer diameters between 1 and 2 μm, varying inner diameters and varying film thickness. We discuss measurements and the results of numerical computations of the switching fields for the transition from the vortex state to the ‘onion’ state. A large dependence on the ring width and the film thickness is found.  相似文献   

17.
Samples made of the CR-39 and PM-355 plastic nuclear track detectors (NTDs) as well as of the CN films were irradiated with quasi-monoenergetic beams of protons, alphas, N+-, and O+-ions produced by various accelerators. For different samples an energy value of the particle beams was changed from several hundreds keV to 3 or 4.5 MeV. After irradiation the detector samples were etched chemically under controlled conditions during periods lasting from 2 hrs to 20 hrs. Every 2 hrs track diameters were measured by means of an optical microscope. Differences in the crater diameters in the detectors etched in steps, and those etched continously, have been found to be smaller than 10 percent. The paper results detailed calibration diagrams showing a dependence of track diameters on the ion energy value for different etching times.  相似文献   

18.
Several types of copolymers of CR-39 were prepared to find its usefulness as a nuclear track detector of high sensitivity. Track responses of these copolymers were investigated by irradiating energetic ions from proton through Ar. The copolymer of CR-39 monomer with N-isopropylacrylamide (NIPAAm) shows higher sensitivity than that of pure CR-39 for low LET particles such as protons. Preliminary results are reported for the track responses of copolymers (CR-39/NIPAAm) with various contents of NIPAAm as well as the etching properties.  相似文献   

19.
In the current work, alpha particle spectroscopy is investigated experimentally by utilizing the over-etched track lengths in the CR-39 detector. CR-39 samples were exposed perpendicularly to alpha particles emitted from 241Am with an energy ranging from 0.5 to 5.5 MeV. CR-39 samples were etched in 6.25 N NaOH at (70±0.5)°C for different durations. The track diameter and track length were measured under an optical microscope. The results show that, the energy-over-etched track length calibration curve is monotonic, in other words, the over-etched track length is a monotonic function in alpha particle energy. On the other hand, the energy-diameter calibration curve is degenerated, i.e. alpha track diameter is non-monotonic function in alpha particle energy. These results suggest that the CR-39 detector could be used as a wide range alpha particles spectrometer using an energy-over-etched track length calibration curve.  相似文献   

20.
A study has been made on the UV-VIS and FTIR spectra of CR-39 plastics irradiated with 50 kVp tube X-rays in the dose range 0ndash;45 MR. The optical transmittance over the wavelength region of 200–1000nm decreases with the X-ray exposure, much greater decrease being observed in the UV region. The IR absorption spectra of the irradiated samples show the presence of two new strong absorption bands at the frequencies 655 and 2340 cm−1, indicative of the gas CO2 produced inside the plastic.The absorbance of these bands increases linearly with the X-ray dose.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号