首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Red pigment-concentrating hormone (RPCH), an octapeptide found in crustaceans and insects with the sequence pGlu-Leu-Asn-Phe-Ser-Pro-Gly-Trp-NH2, is an N- and C-terminally blocked uncharged peptide. These structural features are shared with many members of the larger adipokinetic hormone (AKH)/RPCH peptide family in insects. We have applied vacuum UV matrix-assisted laser desorption/ionization (MALDI)-Fourier transform ion cyclotron mass spectrometry (FTMS) to the direct analysis of crustacean sinus gland tissues, using 2,5-dihydroxybenzoic acid (DHB) as the MALDI matrix, and have found that RPCH is detected in the cationized, [M + Na]+, form under conditions where other peptides in the direct tissue spectra are protonated without accompanying [M + Na]+ or [M + K]+ satellite peaks. The [M + H]+ ion for RPCH is not detected in tissue samples or for an RPCH standard, even when care is taken to eliminate metal ions. This behavior is not unprecedented; however, both direct tissue spectra and SORI-CID spectra provide no clues to suggest that the ionizing agent is a metal cation. In this communication, we characterize the MALDI-FTMS ionization and SORI-CID mass spectra of the [M + Na]+ and [M + K]+ ions from RPCH, and report on the detection of this neuropeptide in sinus gland tissues from the lobster Homarus americanus and the kelp crab Pugettia producta. We describe two strategies, an on-probe extraction procedure and a salt-doping approach, that can be applied to previously analyzed MALDI tissue samples to enhance and unmask sodiated peptides that may otherwise be mistaken for novel neuropeptides.  相似文献   

2.
Fine metal or metal oxide powder as an alternative to conventional organic matrices in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been utilized successfully for lower molecular mass analytes, poly(ethylene glycol) 200 (PEG 200) and methyl stearate. Eleven kinds of particle, Al, Mn, Mo, Si, Sn, SnO2, TiO2, W, WO3, Zn and ZnO, were evaluated. The analyte was mixed with a metal or metal oxide powder (inorganic matrix) with particle diameter of tens of micrometers and liquid dispersant, followed by application to the sample target. Using a commercial MALDI-TOFMS instrument equipped with an internal 337 nm pulsed nitrogen laser, the analytes, PEG 200 and methyl stearate, were ionized as the alkali metal ion adducted molecules [M+Na]+ or [M+K]+ when the inorganic matrices Mn, Mo, Si, Sn, TiO2, W, WO3, Zn or ZnO were used. In the case of an Al matrix, PEG 200 was ionized as [M+K]+, whereas methyl stearate was ionized as [M+H]+ and [M+Al]+. These particles have potential as the matrix for MALDI. During our examination, however, only SnO2 particles did not ionize either PEG 200 or methyl stearate. Based on our protocol, when TiO2 powder was suspended with liquid paraffin, PEG 200 and methyl stearate gave their MALDI-TOF mass spectra with the lowest background noise and highest intensity. TiO2 powder seemed to be a broad potential matrix for low molecular mass polar or non-polar analytes. The results suggested that bulk particles caused rapid heating/vaporization processes and ionized analyte molecules under irradiation with a pulsed UV laser. The present method can be readily applied to obtain the low background noise MALDI-TOF mass spectra of small-sized compounds.  相似文献   

3.
D-Glucose and 19 glucose derivatives were investigated by positive and negative ion matrix assisted laser desorption/ionization time-of-flight mass spectrometry using 2,5-dihydroxybenzoic acid (DHB) as the matrix. The set of substrates includes oligomers of amylose and cellulose, native alpha-, beta-, and gamma-cyclodextrin, and chemically modified beta- and gamma-cyclodextrins. These analytes were chosen to modulate molecular weight, polarity, and capability of establishing noncovalent interactions with guest molecules. In the negative-ion mode, the DHB matrix gave rise to charged multicomponent adducts of type [M + DHB - H]- (M = oligosaccharide) selectively for those analytes matching the following conditions: (i) underivatized chemical structure and (ii) number of glucose units > or = 4. In the positive-ion polarity, only some amylose and cellulose derivatives and methylated beta-cyclodextrins provided small amount of cationized adducts with the matrix of type [M + DHB + X]+ (X = Na or K), along with ubiquitous [M + X]+ ions. The results are discussed by taking into account analyte-matrix association phenomena, such as hydrogen bond and inclusion phenomena, as a function of the molecular structure of the analyte. The conclusions derived by mass spectrometric data are compared with the X-ray diffraction data obtained on a single crystal of the 1:1 alpha-cyclodextrin - DHB noncovalent adduct.  相似文献   

4.
A sensitive and selective method for the determination of alpha-cyclodextrin in human plasma is described using beta-cyclodextrin as an internal standard. After protein precipitation with perchloric acid, the analytes were isolated from human plasma by solid-phase extraction on Bond Elut C18 cartridges. The compounds were chromatographed on a narrow-bore aminopropyl column (125 x 2 mm i.d., 5 microm) and analyzed by electrospray ionization mass spectrometry in the positive selected-ion mode using the [M+NH4]+ ion. The lower limit of quantitation was 5 ng ml(-1) of human plasma. Linear calibration curves were obtained over the concentration range 5-1000 ng ml(-1) of human plasma. The intra- and inter-assay precisions were <18% and the accuracy was <10.5% over the entire concentration range. During the method development, the ionization efficiencies of the analytes in plasma samples originating from different sources were examined to overcome the matrix effect problems caused by co-eluting endogenous compounds. The method was successfully applied to pharmacokinetic studies in human volunteers.  相似文献   

5.
The structural analysis of small drug molecules by directly coupling thin-layer chromatography (TLC) with postsource-decay (PSD) matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is reported. The applicability of this technique is shown using two examples: the TLC-PSD MALDI analysis of two representatives of nonsteroidal antiinflammatory drugs (tenoxicam and piroxicam) and the analysis of the pharmaceutically active compound UK-137,457 and one of its related substances UK-124,912. The matrices alpha-cyano-4-hydroxycinnamic acid (alpha-CHCA) and graphite are used to investigate the effect of the precursor ion selection on the TLC-PSD MALDI spectra of the drug molecules studied. Although alpha-CHCA enhances the [M+H]+ ion formation graphite produces in general only sodium adducts. Structural differentiation of tenoxicam and piroxicam is possible only by selecting the sodium adduct of both drug molecules as precursor ions. In the case of the TLC-PSD MALDI analysis of UK-137,457 and its related substance UK-124,912 at the 1% level, the PSD spectra obtained in alpha-CHCA by selecting the protonated adduct of the small molecules as precursor ions shows distinguishable dissociation patterns containing structurally significant information.  相似文献   

6.
Matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry was investigated for the simultaneous detection of several metabolites, as applicable to global metabolite analysis (metabolomics). The commonly employed organic matrices alpha-cyano-4-hydroxycinnamic acid and 3,5-dihydroxybenzoic acid, in both the crystalline and ionic liquid forms, were investigated. The employment of a low matrix-to-analyte molar ratio suppressed matrix peaks and was effective in detecting all the metabolites with a unique mass in a 30-metabolite synthetic cocktail, albeit to varying degrees. These matrix-suppressed laser desorption/ionisation (MSLDI) analyses were performed in the positive ion mode, and metabolites were detected as the protonated [M+H]+, sodiated [M+Na]+ or potassiated [M+K]+ species. The spectral signals were dominated by basic metabolites. It was possible to detect components of a synthetic cocktail when it was spiked quantitatively into a microbial extract, demonstrating the feasibility of using the technique for detecting metabolite signals in a complex biological matrix. However, analyte suppression effects were noted when the relative proportion of one analyte was allowed to increasingly dominate the others in a mixture. The implications of the findings with respect to applications in metabolomic investigations are discussed.  相似文献   

7.
建立了高效液相色谱-电喷雾飞行时间质谱联用技术快速鉴别高沸点多环芳烃的方法。多环芳烃经色谱柱分离后,通过柱后添加AgNO3溶液诱导其在电喷雾离子源中电离,生成多环芳烃[M]+及其复合[M+Ag]+和[2M+Ag]+特征离子,根据所获得的各特征离子的精确分子量和分子式,可实现多环芳烃类化合物的快速鉴别。将本方法用于美国环保局(USEPA)规定的16种优先控制多环芳烃及原油中多环芳烃类化合物的分析鉴别,结果表明,四环以上的PAHs质谱信号良好,说明本方法适用于四环以上的高分子量、高沸点多环芳烃类化合物的分析鉴别。  相似文献   

8.
A series of hexa- to decapeptides (molecular mass range 800-1200) were labeled with naphthalene-2,3-dicarboxaldehyde, which preferentially reacts with the primary amino groups of a peptide. A highly stable peptide conjugate is formed, which allows selective analysis by fluorescence at excitation and emission wavelengths of 420 and 490 nm, respectively. After removal of unreacted compounds, the peptide conjugates were characterized by matrix-assisted laser desorption/ionization (MALDI) time-of-flight and nano-electrospray ionization (ESI) ion trap mass spectrometry. They readily form both [M + H]+ ions by MALDI and both [M + H]+ and [M + 2H]2+ ions by ESI. Furthermore, the fragmentation behavior of the N-terminally tagged peptides, exhibiting an uncharged N-terminus, was investigated applying post-source decay fragmentation with a curved field reflector and collision-induced dissociation with a quadrupole ion trap. Fragmentation is dominated in both cases by series of a-, b- and y-type ions and [M + H - HCN]+ ions. Peptide bonds adjacent to the fluorescence label were less susceptible to cleavage than the bonds of the non-derivatized peptide ions. In general, the resulting fragment ion patterns were less complex than those of the underivatized peptides.  相似文献   

9.
Silver ion complexes of peptides [M + (Ag)n]+, M = angiotensin I or substance P where n = 1–8 and 17–23 for angiotensin I and n = 1–5 for substance P, are identified and characterized using matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS). The Ag+ coordination number exceeds the number of available amino acid residues in angiotensin I whereas the number of observed complexes in substance P is less than the number of amino acid residues in it. The larger coordination number of angiotensin I with Ag+ indicates the simultaneous binding of several Ag+ ions to the amino acid residue present in it. The lower number of observed complexes in substance P suggests the binding of two or more residues to one Ag+ ion. The presence of trifluoroacetic acid in the peptide samples reduces the Ag+ coordination ability in both the peptides which indicates that the basic residues in it are already protonated and do not participate in the Ag+‐binding process. The Ag+ ion also forms a complex with the α‐cyano‐4‐hydroxycinnamic acid (CHCA) matrix and is observed in the MALDI mass spectra and the formation of [CHCA + Ag]+, [CHCA + AgNO3]+ and [(CHCA)2 + Ag]+ ions is due to the high binding affinity of Ag+ to the CN group of CHCA. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
The mass spectra of peptides obtained with different matrices were compared using a matrix-assisted laser desorption/ionization (MALDI) ion source and a multi-turn time-of-flight (TOF) mass spectrometer, MULTUM-IMG, which has been developed at Osaka University. Two types of solid matrices, alpha-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB), and a liquid matrix made from a mixture of 3-aminoquinoline and CHCA were used. When measuring the peak signal intensity of human angiotensin II [M+H]+ from a fixed sample position, the liquid matrix produced a stable signal over 1000 laser shots, while the signal obtained with CHCA and DHB decayed after about 300 and 100 shots, respectively. Significant differences in the mass resolving power were not observed between the spectra obtained with the three matrices. Signal peak areas were measured as a function of the cycle number in a multi-turn ion trajectory, i.e., the total flight time over a millisecond time scale. For both [M+H]+ of human angiotensin II and bovine insulin, the decay of the signal peak area was the most significant with CHCA, while that measured with DHB was the smallest. The results of the mean initial ion velocity measurements suggested that the extent of metastable decomposition of the analyte ions increased in order of DHB, the liquid matrix, and CHCA, which is consistent with the difference in the decay of the signal peak area as the total flight time increased.  相似文献   

11.
12.
Tong H  Sze N  Thomson B  Nacson S  Pawliszyn J 《The Analyst》2002,127(9):1207-1210
Solid phase microextraction (SPME) with matrix assisted laser desorption/ionization (MALDI) introduction was coupled to mass spectrometry and ion mobility spectrometry. Nicotine and myoglobin in matrix 2,5-dihydroxybenzonic acid (DHB), enkephalin and substance P in alpha-cyano-4-hydroxy cinnaminic acid were investigated as the target compounds. The tip of an optical fiber was silanized for extraction of the analytes of interest from solution. The optical fiber thus served as the sample extraction surface, the support for the sample plus matrix, and the optical pipe to transfer the laser energy from the laser to the sample. The MALDI worked under atmospheric pressure, and both an ion mobility spectrometer and a quadrupole/time-of-flight mass spectrometer were used for the detection of the SPME/MALDI signal. The spectra obtained demonstrate the feasibility of the SPME with MALDI introduction to mass spectrometry instrumentation.  相似文献   

13.
In the matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS) analysis of various compounds synthesized in our laboratory, strong [M - H]+ ion peaks were often observed for the molecules with tertiary amino groups. In this work, the MALDI TOF MS behavior of two groups of compounds that incorporate tertiary amino moieties was investigated. One group is bisurea dimethylanilines (BUDMAs) prepared for the study of molecular recognition in thermoplastic elastomers, and the other group is the poly(propylene imine) diaminobutane dendrimers. The results clearly demonstrate the appearance of the [M - H]+ ions. In order to understand the possible mechanisms for the generation of these ions, a series of model compounds, ranging from primary to tertiary amines, were investigated. Unlike the tertiary amines, no [M - H]+ ion peaks were recorded for the primary amines, and only barely detectable ones, if any, for some secondary amines. It appears that the tertiary amino groups play an important role in the formation of these ions. In addition to MALDI TOF MS analysis, these samples were also applied to electrospray ionization (ESI) MS where no [M - H]+ ions were observed. The results indicate that the generation of [M - H]+ ion is due to the unique MALDI conditions and is likely to be formed via dehydrogenation of a protonated tertiary amine resulting in an N=C double bond. The absence of [M - H]+ ion peaks for the primary and secondary amines is probably because upon their formation these ions could easily transfer one proton to the corresponding amines in the MALDI gas-phase plume, yielding neutral imines that cannot be detected by MS.  相似文献   

14.
The role of propionitrile in the production of [M+H]+ under atmospheric pressure photoionization (APPI) was investigated. In dopant-assisted APPI using acetone and anisole, protonated acetone and anisole radical cations were the most prominent ions observed. In dopant-free or direct APPI in acetonitrile, however, a major ion in acetonitrile was detected and identified as propionitrile, using high accuracy mass measurement and collision induced dissociation studies. Vaporizing ca. 10(-5) M althiazide and bendroflumethazide under direct APPI in acetonitrile produced their corresponding protonated species [M+H]+. In addition to protonated acetonitrile, its dimers, and acetonitrile/water clusters, protonated propionitrile, propionitrile dimer, and propionitrile/water clusters were also observed. The role of propionitrile, an impurity in acetonitrile and/or a possible product of ion-molecule reaction, in the production of [M+H]+ of althiazide and bendroflumethazide was further investigated in the absence of dopant using propionitrile-d5. The formation of [M+D]+ species was observed, suggesting a possible role of propionitrile in the protonation process. Additionally, an increase in the [M+H]+ signal of althiazide and bendroflumethazide was observed as a function of propionitrile concentration in acetonitrile. Theoretical data from the literature supported the assumption that one possible mechanism, among others, for the formation of [M+H]+ could be attributed to photo-initiated isomerization of propionitrile. The most stable isomers of propionitrile, based on their calculated ionization energy (IE) and relative energy (DeltaE), were assumed to undergo proton transfer to the analytes, and mechanisms were proposed.  相似文献   

15.
It has been described that ion yield in both positive- and negative-ion matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) of peptides is often inhibited by trace amounts of alkali metals and that the MALDI mass spectra are contaminated by the interfering peaks originating from traces of alkali metals, even when sample preparation is carefully performed. Addition of serine to the commonly used MALDI matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) significantly improved and enhanced the signals of both protonated and deprotonated peptides, [M+H](+) and [M-H](-). The addition of serine to CHCA matrix eliminated the alkali-metal ion adducts, [M+Na](+) and [M+K](+), and the CHCA cluster ions from the mass spectra. Serine and serinephosphate as additives to CHCA enhanced and improved the formation of molecular-related ions of phosphopeptides in negative-ion MALDI mass spectra.  相似文献   

16.
Negative ion production from peptides and proteins was investigated by matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) mass spectrometry. Although most research on peptide and protein identification with ionization by MALDI has involved the detection of positive ions, for some acidic peptides protonated molecules are not easily formed because the side chains of acidic residues are more likely to lose a proton and form a deprotonated species. After investigating more than 30 peptides and proteins in both positive and negative ion modes, [M–H] ions were detected in the negative ion mode for all peptides and proteins although the matrix used was 2,5‐dihydroxybenzoic acid (DHB), which is a good proton donor and favors the positive ion mode production of [M+H]+ ions. Even for highly basic peptides without an acidic site, such as myosin kinase inhibiting peptide and substance P, good negative ion signals were observed. Conversely, gastrin I (1‐14), a peptide without a highly basic site, will form positive ions. In addition, spectra obtained in the negative ion mode are usually cleaner due to absence of alkali metal adducts. This can be useful during precursor ion isolation for MS/MS studies. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

17.
Reduction of analytes in ionization processes often obscures the determination of molecular structure. The reduction of analytes is found to take place in various desorption/ionization methods such as fast atom bombardment (FAB), secondary ion mass spectrometry (SIMS), matrix‐assisted laser desorption/ionization (MALDI) and desorption ionization on porous silicon (DIOS). To examine the extent of the reduction reactions taking place in electrospray droplet impact (EDI) processes, reduction‐sensitive dyes and S‐nitrosylated peptide were analyzed by EDI. No reduction was observed for methylene blue. While methyl red has a lower reduction potential than methylene blue, the reduction product ions were detected. For S‐nitrosylated peptide, protonated molecule ion [M + H]+ and NO‐eliminated molecular ion [M − NO + H]+• were observed but reduction reactions are largely suppressed in EDI compared with that in MALDI. As such, the analytes examined suffer from little reduction reactions in EDI. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
This paper reports the use of an experimental matrix-assisted laser desorption/ionisation (MALDI) ion source fitted to a quadrupole time-of-flight (Q-Tof) mass spectrometer for the analysis of carbohydrates, particularly the N-linked glycans from glycoproteins. Earlier work on the Q-Tof instrument, using electrospray ionisation, gave excellent MS/MS spectra, particularly from the [M + Na]+ ions, but suffered from the major disadvantages that the signal was often split between singly and multiply charged ions and that sensitivity fell dramatically as the molecular weight of the carbohydrate rose. The MALDI ion source did not suffer from these problems and the instrument produced excellent MS and MS/MS spectra from small amounts of complex, underivatised glycans as well as those derivatised at the reducing terminus. Positive ion MS spectra of sialylated glycans recorded on the new instrument were much less complex than those recorded with a conventional MALDI-TOF instrument because of the absence of ions resulting from metastable (post-source decay, (PSD)) fragmentations occurring in the flight tube. However, considerable fragmentation by loss of sialic acid still occurred. MS/MS spectra of the [M + Na]+ ions from all compounds were almost identical to those recorded earlier with the electrospray-Q-Tof combination and far superior to MALDI-PSD spectra recorded with reflectron-TOF instruments. Spectra are shown for neutral and sialylated N-linked glycans from chicken ovalbumin, riboflavin binding protein, alpha1-acid glycoprotein, bovine fetuin and ribonuclease B, both as free glycans and as those derivatised at their reducing termini. The technique was applied to the structural determination of N-linked glycans from human secretory IgA and Apo-B 100 from human low-density lipoprotein.  相似文献   

19.
Fatty acid amides are a class of compounds with newly discovered biological activity. The ion trap mass spectrometric characteristics of silylated fatty acid amides were examined. Silylation of primary fatty acid amides is required prior to gas chromatography owing to thermal instability of the underivatized compound. The trimethylsilylated amides do not yield a molecular ion under normal electron ionization conditions (70 eV). With methane as a chemical ionization gas, the [M+H]+ ion appears. The [M+H]+ ion also appears when the helium buffer gas pressure is increased in the ion trap. There are three fragments other than the [M+H]+ peak that are predominant in the ion trap mass spectra of these compounds. Two of the fragments have been reported previously, namely the m/z 59 and the [M-71]+ fragments. The fragment of m/z 72 was identified and is the result of a rearrangement. Isotopic labeling was used to confirm fragment identity and the composition of the rearrangement products. Fragmentation patterns were affected by the amide chain length and concentration.  相似文献   

20.
Positive ion mass spectral fragmentation of new N-carbamoyl/N-thiocarbamoyl derivatives of narcotine and compounds closely related to it are reported and discussed. The techniques used include electron impact (EI), fast-atom bombardment (FAB), matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) and electrospray ionization tandem mass spectrometry (ESI-MS/MS). Prominent peaks in the mass spectra of these compounds appear to involve C-C bond cleavage beta to the amine nitrogen with loss of the 4,5-dimethoxy(1H)isobenzofuranone moiety from their molecular ions, along with another prominent peak at m/z 382. No molecular ion peaks of these compounds were recorded in EI, whereas intense [M + H]+ ion peaks were observed in FAB and ESI spectra. MALDI also yielded [M + H]+ ion peaks in good agreement with FAB and ESI studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏