首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A highly sensitive, rapid assay method has been developed and validated for the analysis of hyperoside in beagle dog plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves extraction of hyperoside and ginsenoside Re (IS) from beagle dog plasma. Chromatographic separation was carried out on an Agilent Zorbax XDB‐C18 (100 × 2.1 mm, 1.8 µm) column by isocratic elution with acetonitrile and water (50:50, v/v) at a flow rate of 0.25 mL/min with a total run time of 2.0 min. The MS/MS ion transitions monitored were 464.4 → 463.4 for hyperoside and 947.12 → 969.60 for IS. Linear responses were obtained for hyperoside ranging from 10 to 5000 ng/mL. The intra‐and inter‐day precisions (RSDs) were <5.38 and 3.39% and the extraction recovery ranged from 94.39 to 100.78% with an RSD <3.82%. Stability studies showed that hyperoside was stable in preparation and analytical process. The results indicated that the validated method was successfully used to determine the concentration–time profiles of hyperoside. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
In this study, a sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the quantification of demethylzeylasteral in rat plasma. Electrospray ionization was operated in the negative ion mode while demethylzeylasteral and oleanolic acid (internal standard) were measured by selected reaction monitoring (demethylzeylasteral: m/z 479.2 → 436.0; oleanolic acid: m/z 454.9 → 407.2). This LC–MS/MS method had good selectivity, sensitivity, accuracy and precision. The pharmacokinetic profiles of demethylzeylasteral were subsequently examined in Wistar rats after oral or intravenous administration.  相似文献   

3.
A sensitive, specific and rapid LC‐ESI‐MS/MS method has been developed and validated for the quantification of epacadostat in mouse plasma using tolbutamide as an internal standard (IS) as per regulatory guidelines. Sample preparation was accomplished through a protein precipitation. Chromatographic separation was performed on an Atlantis dC18 column using a binary gradient using mobile phase A (acetonitrile) and B (0.2% formic acid in water) at a flow rate of 0.90 mL/min. Elution of epacadostat and IS occurred at ~2.41 and 2.51 min, respectively. The total chromatographic run time was 3.2 min. A linear response function was established in the concentration range of 1.07–533 ng/mL. The intra‐ and inter‐day accuracy and precision were in the ranges of 1.81–12.9 and 3.80–11.1%, respectively. This novel method has been applied to a pharmacokinetic study in mice.  相似文献   

4.
A simple, specific, sensitive and rapid LC‐ESI‐MS/MS method has been developed and validated for the quantification of 4‐methylpyrazole in dog plasma using N‐methylnicotinamide‐d4 as an internal standard (IS) as per regulatory guidelines. Sample preparation was accomplished through a simple protein precipitation. Chromatographic separation of 4‐methylpyrazole and the IS was performed on a monolithic (Chromolith RP18e) column using an isocratic mobile phase comprising 0.2% formic acid in water and acetonitrile (20:80, v/v) at a flow rate of 1.0 mL/min. Elution of 4‐methylpyrazole and the IS occurred at ~1.60 and 1.56 min, respectively. The total chromatographic run time was 3.2 min. A linear response function was established in the concentration range of 4.96–4955 ng/mL. The intra‐ and inter‐day accuracy and precision were in the ranges 1.81–12.9 and 3.80–11.1%, respectively. This novel method has been applied to a pharmacokinetic study in dogs.  相似文献   

5.
A sensitive, selective and rapid LC–ESI–MS/MS method has been developed and validated for the quantification of copanlisib in mouse plasma using enasidenib as an internal standard (IS) as per regulatory guideline. Copanlisib and the IS were extracted from mouse plasma using ethyl acetate as an extraction solvent and chromatographed using an isocratic mobile phase (0.2% formic acid–acetonitrile; 25:75, v/v) on a HyPURITY C18 column. Copanlisib and the IS eluted at ~0.95 and 2.00 min, respectively. The MS/MS ion transitions monitored were m/z 481.1 → 360.1 and m/z 474.0 → 456.0 for copanlisib and the IS, respectively. The calibration range was 3.59–3588 ng/mL. The intra‐ and inter‐batch accuracy and precision (RE and RSD) across quality controls met the acceptance criteria. Stability studies showed that copanlisib was stable in mouse plasma for one month. This novel method has been applied to a pharmacokinetic study in mice.  相似文献   

6.
Hinokiflavone has drawn a lot of attention for its multiple biological activities. In this study, a sensitive and selective method for determination of hinokiflavone in rat plasma was developed for the first time, using liquid chromatography–tandem mass spectrometry (LC–MS/MS). Amentoflavone was used as an internal standard. Separation was achieved on a Hypersil Gold C18 column with isocratic elution using methanol–water (65:35, v /v) as mobile phase at a flow rate of 0.3 mL/min. A triple quadrupole mass spectrometer operating in the negative electrospray mode with selected reaction monitoring was used to detect the transitions of m/z 537 → 284 for hinokiflavone and m/z 537 → 375 for IS. The LOQ was 0.9 ng/mL with a linear range of 0.9–1000 ng/mL. The intra‐ and inter‐day accuracy (RE%) ranged from −3.75 to 6.91% and from −9.20 to 2.51% and the intra‐ and inter‐day precision (RSD) was between 0.32–14.11 and 2.85–10.04%. The validated assay was successfully applied to a pharmacokinetic study of hinokiflavone in rats. The half‐life of drug elimination at the terminal phase was 6.10 ± 1.86 h, and the area under the plasma concentration‐time curve from time zero to the time of last measurable concentration and to infinity values obtained were 2394.42 ± 466.86 and 2541.93 ± 529.85 h ng/mL, respectively.  相似文献   

7.
A highly sensitive, rapid assay method has been developed and validated for the analysis of polyphyllin H in beagle dog plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves extraction of polyphyllin H and ginsenoside Re (IS) from beagle dog plasma. Chromatographic separation was carried out on an Agilent Zorbax XDB‐C18 (100 × 2.1 mm, 1.8μm) column by isocratic elution with acetonitrile and water (50:50, v/v) at a flow rate of 0.25 mL/min with a total run time of 2.5 min. The MS/MS ion transitions monitored were 870.46 → 869.6 for polyphyllin H and 947.12 → 969.60 for IS. Linear responses were obtained for polyphyllin H ranging from 1 to 50 ng/mL. The intra‐and inter‐day precisions (RSDs) were <1.77 and 3.39% and the extraction recovery ranged from 91.89 to 93.33% with RSD <2.68%. Stability studies showed that polyphyllin H was stable in the preparation and analytical process. The results indicated that the validated method was successfully used to determine the concentration–time profiles of polyphyllin H. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
A simple and reliable liquid chromatography–mass spectrometry (LC–MS) method was developed for simultaneous determination of saikosaponin A, saikosaponin B1, saikosaponin C, saikosaponin D and saikosaponin F in rat plasma using glycyrrhetinic acid as an internal standard (IS). The separation was operated on a Waters BEH C18 column. The mobile phases of gradient elution consisted of acetonitrile (A) and 0.1% aqueous acetic acid (B). The mass spectrometric detection was accomplished in multiple reaction monitoring mode. The five saponins displayed good linearity (r2 > 0.9996). The lower limits of quantitation of saikosaponin A, saikosaponin B1, saikosaponin C, saikosaponin D and saikosaponin F were determined to be 2.9, 2.3, 3.5, 2.9 and 3.1 ng/mL, respectively. Moreover, the intra‐ and inter‐day precisions of the five saponins showed an RSD within 2.96%, whereas the accuracy (RE) ranged from ?2.28 to 2.78%. Finally, the developed method was fully validated and applied to a comparative pharmacokinetic study of the five bioactive saponins in rats following oral administration of crude and vinegar‐processed Bupleurum scorzonerifolium.  相似文献   

9.
A simple, specific and sensitive LC‐MS/MS method was developed and validated for the determination of mesalazine in beagle dog plasma. The plasma samples were prepared by protein precipitation, then the separation of the analyte was achieved on a Waters Spherisorb C6 column (150 × 4.6 mm, 5 µm) with a mobile phase consisting of 0.2% formic acid in water–methanol (20:80, v/v). The flow rate was set at 1.0 mL/min with a split ratio of 3:2. Mass spectrometric detection was achieved by a triple‐quadrupole mass spectrometer equipped with an electrospray source interface in positive ionization mode. Quantitation was performed using selected reaction monitoring of precursor–product ion transitions at m/z 154 → m/z 108 for mesalazine and m/z 285 → m/z 193 for diazepam (internal standard). The linear calibration curve of mesalazine was obtained over the concentration range 50–30,000 ng/mL. The matrix effect of mesalazine was within ±9.8%. The intra‐ and inter‐day precisions were <7.9% and the accuracy (relative error) was within ±3.5%. The validated method was successfully applied to investigate the pharmacokinetics of mesalazine in healthy beagle dogs after rectal administration of mesalazine suppository. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
Genipin (GP), an active metabolite of geniposide (GE), exhibits more potent pharmacological effects than its parent compound. In this paper, a sensitive LC‐MS/MS method was developed and fully validated for the simultaneous determination of GE and GP in rat plasma. We found that GP degraded rapidly in rat plasma at room temperature as a result of irreversible binding with the endogenous nucleophiles in plasma. GP was stable when the sample's pH was ≤4.0. The degradation of GP in rat plasma was well prevented by immediate addition of 5% glacial acetic acid to the freshly collected plasma. The detection was performed on a tandem mass spectrometer coupled with electrospray ionization source in negative mode. Quantification was conducted by multiple reaction monitoring of the transitions [M + CH3COO] m/z 447.3 → 225.3 for GE and [M − H] m/z 225.2 → 123.1 for GP. The method exhibited high sensitivity (LLOQ 1 ng/mL for GE and 0.2 ng/mL for GP) by selecting the acetate adduct ions as the precursor ions for GE. The robust developed method was successfully applied to a pharmacokinetic study in rats after oral administration of GE.  相似文献   

11.
Isomers β‐asarone and α‐asarone have recently been demonstrated to have differential pharmacological activities . Here, we report an LC–MS/MS method developed using acetonitrile to extract two isomeric phenylpropenes from rat plasma. Separation was achieved using a XDB‐C18 column (100 × 2.1 mm; i.d., 1.8 μm) with a mobile phase of methanol–0.1% formic acid (55:45, v/v) at a flow rate of 0.3 mL/min. Calibration curves ranging from 5.20 to 2080 ng/mL for β‐asarone and from 3.68 to 1470 ng/mL for α‐asarone were linear (r2 ≥ 0.9938) with the lower limits of quantification being 5.20 and 3.68 ng/mL for both isomers. Intravenous administration of β‐asarone (2.22 mg/kg) and α‐asarone (2.36 mg/kg) in rats yielded half‐lives of 13.40 ± 4.11 and 28.88 ± 7.82 min with clearance values of 0.196 ± 0.062 mL/min/kg and 0.112 ± 0.012 mL/min/kg for β‐asarone and α‐asarone, respectively.  相似文献   

12.
A liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) method has been developed and validated for the quantification of tunicamycin in rat plasma as per regulatory guideline. Chromatography of tunicamycin and the IS in the processed plasma samples was achieved on an X‐Terra phenyl column using a binary gradient (mobile phase A, acetonitrile and mobile phase B, 5 mm ammonium formate) elution at a flow rate of 0.6 ml/min. LC–MS/MS was operated under the multiple reaction monitoring mode using the electrospray ionization technique in positive ion mode and the transitions of m/z 817.18 → 596.10, 831.43 → 610.10, 845.29 → 624.10, 859.23 → 638.10 and 309.24 → 163.20 were used to quantitate homologs A–D and the IS, respectively. The total chromatographic run time was 4.5 min. The correlation coefficient (r2) was >0.99 for all homologs with accuracy 90.7–107.4% and precision 0.74–15.1%. The recovery of homologs was 78.6–90.2%. No carryover was observed and the matrix effect was minimal. Tunicamycin four homologs were found to be stable on the bench‐top for 6 h, for up to three freeze–thaw cycles, in the injector for 24 h and for 1 month at ?80 ° C. The applicability of the validated method has been demonstrated in a rat pharmacokinetic study.  相似文献   

13.
Triptolide is one of the main active ingredients of Tripterygium wilfordii Hook. F. In this study, a sensitive LC–MS/MS method was established and validated to determine the concentration of triptolide in rat plasma. Triptolide and an internal standard [(5R)‐5‐hydroxytriptolide] were extracted from 100 μL of rat plasma with acetonitrile, and the dried residue was then reconstituted and reacted with benzylamine to produce benzylamine triptolide and benzylamine (5R)‐5‐hydroxytriptolide. Derivatization increased the sensitivity of triptolide detection by ~100‐fold. Quantification was performed using a QTRAP 5500 tandem mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode with an ion transition m/z 468.5 → 192.0 for benzylamine triptolide and m/z 484.3 → 192.1 for benzylamine (5R)‐5‐hydroxytriptolide. Good linearity was observed in the range of 0.030–100 ng/mL with a lower limit of quantitation of 0.030 ng/mL. The intra‐ and inter‐day precision was <6.5%, and the accuracy ranged from ?11.7 to ?4.4%. The recovery remained consistent and was reproducible at different concentrations. This method was successfully applied to the study of triptolide drug–drug interactions in Sprague–Dawley rats. With the use of itraconazole (40 mg/kg, p.o.) as a CYP3A inhibitor, the plasma exposure of triptolide in rats was increased by 36%.  相似文献   

14.
Cabozantinib (CBZ) is used for the treatment of progressive, metastatic medullary thyroid cancer. Its major oxidative metabolite is cabozantinib N‐oxide (CBN), which contains a structural alert associated with mutagenicity, yet the pharmacokinetics studies lack the simultaneous investigation of CBN and dose proportionality. In the current study a simple LC–MS/MS method was developed and validated for the simultaneous estimation and pharmacokinetic investigation of CBZ and CBN in rat plasma. The analytes were separated on a Waters Atlantics C18 column (2.1 × 150 mm, 3 μm). The mass spectrometry analysis was conducted in positive ionization mode with multiple reaction monitoring. Good linearity was observed over the concentration ranges of 0.500–5000 ng/mL for CBZ and 0.525–2100 ng/mL for CBN. The extraction recoveries were constant and the intra‐ and inter‐batch precision and accuracy were acceptable for the analysis of biological samples. The method was successfully applied for the simultaneous estimation of CBZ and CBN in a pharmacokinetic study in Sprague–Dawley rats. After oral administration of CBZ (1, 5 and 12.6 mg/kg), although CBZ showed dose proportionality, the metabolite CBN showed obvious nonlinear elimination pharmacokinetics with greater than dose‐proportional increases in exposure.  相似文献   

15.
A rapid, sensitive and reproducible LC–MS/MS method was developed and validated to determine iguratimod in human plasma. Sample preparation was achieved by protein precipitation with acetonitrile. Chromatographic separation was operated on an Ultimate® XB‐C18 column (2.1 × 50 mm, 3.5 μm, Welch) with a flow rate of 0.400 mL/min, using a gradient elution with acetonitrile and water which contained 2 mm ammonium acetate and 0.1% formic acid as the mobile phase. The detection was performed on a Triple Quad™ 5500 mass spectrometer coupled with an electrospray ionization interface under positive‐ion multiple reaction monitoring mode with the transition ion pairs of m/z 375.2 → 347.1 for iguratimod and m/z 244.3 → 185.0 for agomelatine (the internal standard), respectively. The method was linear over the range of 5.00–1500 ng/mL with correlation coefficients ≥0.9978. The accuracy and precision of intra‐ and inter‐day, dilution accuracy, recovery and stability of the method were all within the acceptable limits and no matrix effect or carryover was observed. As a result, the main pharmacokinetic parameters of iguratimod were as follows: Cmax, 1074 ± 373 ng/mL; AUC0–72, 13591 ± 4557 ng h/mL; AUC0–∞, 13,712 ± 4613 ng h/mL; Tmax, 3.29 ± 1.23 h; and t1/2, 8.89 ± 1.23 h.  相似文献   

16.
17.
A simple and sensitive method based on ultra‐high‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) has been developed for the determination of TM‐2, which was a novel semi‐synthetic taxane derivative in beagle dog plasma. Cabazitaxel was chosen as internal standard. Following extraction by methyl tert‐butyl ether, the chromatographic separation was achieved on a Thermo Syncronis C18 column (50 × 2.1 mm, 1.7 µm) by gradient elution within a runtime of 3.5 min. The mobile phase consisted of (A) acetonitrile and (B) 2 mmol/L ammonium acetate in water. The detection was accomplished using positive ion electrospray ionization in multiple reaction monitoring mode. The MS/MS ion transitions were monitored at m/z 812.39 → 551.35 for TM‐2 and 836.36 → 555.26 for IS, respectively. The method was linear for TM‐2 (r = 0.9924) ranging from 2.5 to 1000 ng/mL. The intra‐day and inter‐day precisions (relative standard deviation) were within 8.0 and 17.6%, respectively, and the accuracy (relative error) was less than 2.3%. The extraction recovery ranged from 83.1 to 97.1%. The reliable method was successfully applied to a pharmacokinetic study of TM‐2 in beagle dogs after intravenous drip with different doses of 0.6, 1.2, and 2.4 mg/kg, respectively. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A simple and sensitive liquid chromatography tandem mass spectrometry method was validated for simultaneous quantification of evodiamine and its metabolites 10‐hydroxyevodiamine (M1), 18‐hydroxyevodiamine (M2), 10‐hydroxyevodiamine‐glucuronide (M3) and 18‐hydroxy‐ evodiamine‐glucuronide (M4) in rat plasma for the first time. The analytes were extracted with acetonitrile and separated on a C18 column within 3 min. The detection was achieved in positive selected reaction monitoring mode with precursor‐to‐product transitions at m/z 304.1 → 161.1 for evodiamine, m/z 320.1 → 134.1 for M1, m/z 320.1 → 150.1 for M2, m/z 496.2 → 134.1 for M3, m/z 496.2 → 171.1 for M4 and m/z 349.2 → 305.1 for camptothecin (internal standard). The linearity was evident over the tested concentration ranges with correlation coefficients >0.9991. The lower limits of quantification for evodiamine, M1, M2, M3 and M4 were 0.1, 0.1, 0.1, 0.25 and 0.25 ng mL−1, respectively. Extraction recoveries and matrix effects of the analytes were within the ranges of 84.51–97.21 and 90.13–103.30%, respectively. The accuracy (relative error) ranged from −8.14 to 7.23% while the intra‐ and inter‐day precisions (relative standard deviation) were < 9.31%. The validated assay was successfully applied for the pharmacokinetic study of evodiamine, M1, M2, M3 and M4 in rat. The current study will be helpful in understanding the in vivo disposition of evodiamine.  相似文献   

19.
A highly sensitive, specific and rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) analytical method has been developed and validated for the determination of ospemifene in human plasma using ospemifene‐d4 as an internal standard. Solid‐phase extraction technique with Phenomenex Strata X‐33 μm polymeric sorbent cartridges (30 mg/1 mL) was used to extract the analytes from the plasma. The chromatographic separation was achieved on Agilent Eclipse XDB‐Phenyl, 4.6 × 75 mm, 3.5 μm column using the mobile phase composition of methanol and 20 mm ammonium formate buffer (90:10, v/v) at a flow rate of 0.9 mL/min. A detailed method validation was performed as per the US Food and Drug Administration guidelines and the calibration curve obtained was linear (r2 = 99) over the concentration range 5.02–3025 ng/mL. The API‐4500 MS/MS was operated under multiple reaction monitoring mode during the analysis. The proposed method was successfully applied to a pharmacokinetic study in healthy human volunteers after oral administration of an ospemifene 60 mg tablet under fed conditions.  相似文献   

20.
Yiqifumai Injection is a lyophilized powder preparation widely used to treat coronary heart disease. However, its in vivo bioactive components and pharmacokinetic behavior remain unknown. Therefore a sensitive and specific LC–MS/MS was developed and validated for the simultaneous quantification of eight saponins and four lignans in beagle dog plasma. The plasma samples were pretreated by protein precipitation with methanol–acetonitrile (1:1, v/v). Chromatographic separation of all the 12 analytes and estazolam (internal standard, IS) was successfully accomplished on an Ultimate® XB‐C8 column (100 × 2.1 mm, 3 μm) with a gradient elution system. The total running time was 8 min with a flow rate of 0.40 mL/min. Acquisition of mass spectrometric data was performed via positive electrospray ionization in multiple reaction monitoring mode. The assay was fully validated in terms of selectivity, linear range, lower limit of quantitation, precision, accuracy, matrix effect, recovery and stability. This validated method was successfully applied to the pharmacokinetics of 12 bioactive components after intravenous administration of Yiqifumai Injection to beagle dogs at a dose of 0.541 g/kg.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号