首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The abuse of synthetic esters of natural steroids such as testosterone and estradiol in cattle fattening and sports is hard to detect via routine urine testing. The esters are rapidly hydrolysed in vivo into substances which are also endogenously present in urine. An interesting alternative can be provided by the analysis of the administered synthetic steroids themselves, i.e., the analysis of intact steroid esters in hair by liquid chromatography tandem mass spectrometry (LC/MS/MS). However, retrospective estimation of the application date following a non-compliant finding is hindered by the complexity of the kinetics of the incorporation of steroid esters in hair. In this study, the incorporation of intact steroid esters in hair following pour-on treatment has been studied and critically compared with results from intramuscular treatment. To this end animals were pour-on treated with a hormone cocktail containing testosterone cypionate, testosterone decanoate and estradiol benzoate in different carriers. The animals were either treated using injection and pour-on application once or three times having 1 week between treatments using injection and pour-on application. Animals were slaughtered from 10–12 weeks after the last treatment. Both hair and blood plasma samples were collected and analysed by LC/MS/MS. From the results, it is concluded that after single treatment the levels of steroid esters in hair drop to CCβ levels (5–20 μg/kg) after 5–7 weeks. When treatment is repeated two times, the CCβ levels are reached after 9–11 weeks. Furthermore, in plasma, no steroid esters were detected; not even at the low microgramme per litre level but—in contrast with the pour-on application—after i.m. injection, significant increase of 17β-testosterone and 17β-estradiol were observed. These observations suggest that transport of steroid esters after pour-on application is not only performed by blood but also by alternative fluids in the animal so probably the steroid esters are already hydrolysed and epimerized before entering the blood.  相似文献   

2.
Stilbenes and zeranol are nonsteroidal estrogenic growth promoters which are banned in the European Union (EU) for use in food-producing animals by Council Directive 96/22/EC. A liquid chromatography–tandem mass spectrometry (LC-MS/MS) method was developed for the screening and confirmation of stilbenes (diethylstilbestrol, dienestrol, hexestrol) and resorcylic acid lactones (zeranol and its metabolites taleranol and zearalanone as well as the mycotoxins α-zearalenol, β-zearalenol and zearalenone) in bovine urine. The method permits the confirmation and quantification of stilbenes and resorcylic acid lactones at levels below 1 μg L−1 and 1.5 μg L−1, respectively. The validation was carried out according to Commission Decision 2002/657/EC, Chap. 3.1.3 “alternative validation” by a matrix-comprehensive in-house validation concept. Decision limit CCα, detection capability CCβ, recovery, repeatabiliy, within-laboratory reproducibility and the uncertainty of measurement were calculated. Furthermore, a factorial effect analysis was carried out to identify factors that have a significant influence on the method. Factors considered to be relevant for the method in routine analysis (e.g. operator, matrix condition, storage duration of the extracts before measurement, different cartridge lots, hydrolysis conditions) were systematically varied on two levels. The factorial analysis showed that different cartridge lots, storage durations and matrix conditions can exert a relevant influence on the method.  相似文献   

3.
The direct quantification of deoxynivalenol glucuronide (DON-GlcA) by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and its application as a biomarker of exposure to the Fusarium mycotoxin deoxynivalenol (DON) is reported. Usually, DON exposure is estimated from dietary average intakes or by measurement of the native toxin in urine after enzymatic hydrolysis with β-glucuronidase. These methods are time-consuming, expensive, and fail to determine the ratio of DON to DON-GlcA in a simple one-step procedure. One of the main reasons for the use of indirect methods is the unavailability of DON-GlcA standards. Consequently, DON-3-O-glucuronide (D3GlcA) was synthesized and used to develop a method allowing quantification of both DON and D3GlcA by a simple “dilute and shoot” approach without the need for any cleanup. Limit of detection and apparent recovery of D3GlcA was 3 μg l−1 and 88%, respectively. The identity of D3GlcA in human urine was confirmed by comparison with LC-MS/MS measurements of the synthetically produced D3GlcA standard which was also used for external calibration. The applicability of the method was demonstrated through the analysis of urine samples obtained from a volunteer during regular and cereal-restricted diet, respectively. In regular-diet urine samples, D3GlcA was quantified in concentrations >30 μg l−1 by this approach.  相似文献   

4.
An anti-ketamine molecularly imprinted polymer (MIP) was synthesized and used as the sorbent in a solid-phase extraction protocol to isolate ketamine and norketamine from human hair extracts prior to LC-MS/MS analysis. Under optimised conditions, the MIP was capable of selectively rebinding ketamine, a licensed anaesthetic that is widely misused as a recreational drug, with an apparent binding capacity of 0.13 μg ketamine per mg polymer. The limit of detection (LOD) and lower limit of quantification (LLOQ) for both ketamine and norketamine were 0.1 ng/mg hair and 0.2 ng/mg hair, respectively, when 10 mg hair were analysed. The method was linear from 0.1 to 10 ng/mg hair, with correlation coefficients (R 2) of better than 0.99 for both ketamine and norketamine. Recoveries from hair samples spiked with ketamine and norketamine at a concentration of 50 ng/mg were 86% and 88%, respectively. The method showed good intra- and interday precisions (<5%) for both analytes. Minimal matrix effects were observed during the LC-MS/MS analysis of ketamine (ion suppression −6.8%) and norketamine (ion enhancement +0.2%). Results for forensic case samples demonstrated that the method successfully detected ketamine and norketamine concentrations in hair samples with analyte concentrations ranging from 0.2 to 5.7 ng/mg and from 0.1 to 1.2 ng/mg, respectively.  相似文献   

5.
A fully automated method has been developed for analysis of eighteen antibacterial compounds, including penicillins, cephalosporins and sulfonamides, in animal feed with limits of quantification in the range 0.25–5.79 μg kg−1. The method is based on pressurized liquid extraction of 3 g homogenized feed with water and online clean-up of 500 μL of the extract with C18HD cartridges. The purified sample was directly analysed by liquid chromatography–electrospray tandem mass spectrometry (SPE–LC–ESI-MS–MS). Chromatographic separation was achieved within 10 min by use of a C12 Phenomenex Hydro-RP reversed-phase analytical column and a mobile phase gradient (water + 0.1% formic acid–methanol + 0.1% formic acid). The method was validated, revealing capability for detection of concentrations as low as 0.09 μg kg−1, decision limits (CCα) and detection capabilities (CCβ) in the range 10–174 μg kg−1 and 22–182 μg kg−1, respectively, and inter-day precision ranging from 0.7 to 8.3%. Recovery, with internal standard correction, was in the range 93–134% for all analytes. The method was then applied to analysis of fifteen feed samples, nine of which contained at least one antimicrobial at concentrations between 0.006 and 1.526 mg kg−1. The performance data and results from the method were compared with those from a previous method developed by our group, using offline SPE, by analyzing the same set of samples by both methods. The online SPE approach resulted in slightly improved sensitivity, with LODs of 0.09–2.12 μg kg−1 compared with 0.12–3.94 μg kg−1 by the offline approach. In general, better recovery was achieved by use of online purification (for 72% of the analytes) and the correlation between the two methods was good. The main advantages of the new online method are rapid and automated sample pre-treatment, and reduction of sample manipulation, enabling high-throughput analysis and highly accurate results. Because of all these characteristics, the proposed method is applicable and could be deemed necessary within the field of food control and safety.  相似文献   

6.
Captan and folpet are fungicides largely used in agriculture. They have similar chemical structures, except that folpet has an aromatic ring unlike captan. Their half-lives in blood are very short, given that they are readily broken down to tetrahydrophthalimide (THPI) and phthalimide (PI), respectively. Few authors measured these biomarkers in plasma or urine, and analysis was conducted either by gas chromatography coupled to mass spectrometry or liquid chromatography with UV detection. The objective of this study was thus to develop simple, sensitive and specific liquid chromatography–atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) methods to quantify both THPI and PI in human plasma and urine. Briefly, deuterated THPI was added as an internal standard and purification was performed by solid-phase extraction followed by LC/APCI-MS/MS analysis in negative ion mode for both compounds. Validation of the methods was conducted using spiked blank plasma and urine samples at concentrations ranging from 1 to 250 μg/L and 1 to 50 μg/L, respectively, along with samples of volunteers and workers exposed to captan or folpet. The methods showed a good linearity (R 2 > 0.99), recovery (on average 90% for THPI and 75% for PI), intra- and inter-day precision (RSD, <15%) and accuracy (<20%), and stability. The limit of detection was 0.58 μg/L in urine and 1.47 μg/L in plasma for THPI and 1.14 and 2.17 μg/L, respectively, for PI. The described methods proved to be accurate and suitable to determine the toxicokinetics of both metabolites in human plasma and urine.  相似文献   

7.
This paper describes optimization and validation of a method for sulfadiazine determination in milk samples based on sulfadiazine derivatization with fluorescamine followed by excitation–emission (fluorescence) measurement. For both the optimization and the validation, a comparison between zero-order and first-order signals has been made, showing the advantages of using first-order signals. In the optimization the effects of the temperature of the derivatization reaction, the amount of fluorescamine and the derivatization time on the instrumental signal (maximum intensity or the net analyte signal) are studied by a factorial experimental design, with the optimal values of these factors which give the highest signal being 22 °C for the reaction temperature, 50 μl fluorescamine and 20 min of derivatization time. The validation of the method under the optimal experimental conditions shows that the analytical method is fit-for-purpose, with values of the capability of detection (CCβ) of 4.3 μg l−1 at a sulfadiazine concentration of zero and with probabilities of a false positive and a false negative of 5%. Around the permitted limit (established for the sulfonamides at 100 μg l−1), CCβ is 112 μg l−1. The precision, as the intermediate reproducibility, was established as 1.2 and 3.3 μg l−1 around 0 and 100 μg l−1, respectively. In the application to milk samples spiked with sulfadiazine a mean recovery of around 90% was obtained with a standard deviation of about 8% (14 samples of different concentrations).  相似文献   

8.
A specific, sensitive and robust liquid chromatography tandem mass spectrometry method for determining oxytetracycline, tetracycline, chlortetracycline and doxycycline in royal jelly and honey samples is presented. Extraction of drug residues was performed by ammonium acetate buffer as extractant followed by a clean-up with metal chelate affinity chromatography and solid-phase extraction. Tetracycline analysis was performed using liquid chromatography–electrospray ionisation–tandem mass spectrometry. The presented method is the first validated for royal jelly and in accordance with the requirements set by Commission Decision 2002/657/EC. Recoveries of the methods, calculated spiking the samples at 5.0, 10.0, 20.0 and 30.0 μg kg−1, were 79% to 90% for honey and 77% to 90% for royal jelly. The intra-day precision (RSD) ranged between 8.1% and 15.0% for honey and from 9.1% to 16.3% for royal jelly, while inter-day precision values were from 10.2% to 17.6% and from 10.6% to 18.4% respectively for honey and royal jelly. Linearity for the four analytes was calculated from 5.0 to 50.0 μg kg−1. The decision limits (CCα) ranged from 6.2 to 6.4 μg kg−1 and from 6.1 to 6.5 μg kg−1 for honey and royal jelly, respectively. Detection capabilities values (CCβ) ranged between 7.2 and 7.7 μg kg−1 and from 7.3 to 7.9 μg kg−1 respectively for honey and royal jelly. The developed method is currently in use for confirmation of the official control analysis of honey and royal jelly samples.  相似文献   

9.
Liquid chromatography–tandem mass spectrometry (LC-MS/MS) and gas chromatography–mass spectrometry (GC-MS) have been compared for the analysis of 2-isopropyl thioxanthone (ITX) and 2-ethylhexyl-4-dimethylaminobenzoate (EHDAB). Pressurized liquid extraction (PLE) was applied for the extraction of ITX and EHDAB from milk and milk-based beverages. Samples were homogenized with sea sand and anhydrous sodium sulfate, and were extracted with ethyl acetate at 100 °C and 10.3 × 106 Pa in one cycle of 10 min at 90% flush. Both, GC-MS and LC-MS/MS were suitable to determine these photoinitiators in the PLE extracts, providing appropriate identification and quantification. The recoveries obtained ranged from 70 to 99% for ITX and from 70 to 95% for EHDAB. These recoveries were equal as those obtained by a conventional liquid–liquid partitioning with acetonitrile and tert-butyl methyl ether–hexane. The quantification limits using GC-MS, based on a signal-to-noise ratio of 10, were 0.5 μg/L for ITX and 1 μg/L for EHDAB. The repeatability of the method, as indicated by the relative standard deviations, was within the range 0.9–16.1%. The same parameters calculated using LC-MS/MS result in quantification limits of 0.1 μg/L for ITX and 0.02 μg/L for EHDAB and repeatability within the range 5.2–19.4%. These results pointed out that both techniques are appropriate to determine these compounds in food samples. The method was applied to milk and milk-based beverages from different supermarkets. The ITX and EHDAB contents ranged from 2.5 to 325 μg/L and from 8 to 126 μg/L, respectively. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

10.
A sensitive liquid chromatography–tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of 13 steroidal anti-inflammatory drugs in bovine milk is presented. Due to their weakly acid nature, analytes were separated by ion suppression reversed phase chromatography and detected in positive-ion mode by a high flow electrospray source. Dexamethasone-d4 was used as internal standard. The sample preparation was simple and reliable; it included acidic deproteinization of milk followed by sample enrichment and clean-up, utilizing a C18 solid phase extraction cartridge. Recoveries exceeded 70% with an intra-day precision not larger than 12%. The efficiency of the sample clean-up and internal standardization rendered negligible the matrix effect, estimated by comparing standard and matrix-matched calibration curves. A small-scale reconnaissance was carried out on several raw and whole fresh milk samples. A large number of analyzed samples showed a chromatographic peak, in the retention time window of cortisol, at levels included between its decision limit (CCα) and detection capability (CCβ). As a result of a heat-induced transformation, an isomeric product of triamcinolone was observed during the extract evaporation. Since this rearrangement might occur during the milk pasteurization process, LC-MS/MS and 1H-NMR investigations were performed out to conclusively differentiate the two isomers. One- and two-dimensional proton NMR spectra were able to identify the transformation product as 9a-fluoro-11b,16a-trihydroxy-17b-hydroxymethyl-D-homoandrosta-1,4-diene-3,17a-dione.  相似文献   

11.
A method is developed for the determination of β-blockers in serum and urine at levels of 0.5 μg/mL. The technique uses a combination of solid phase extraction (SPE) with in situ derivatization and supercritical fluid extraction (SFE) with subsequent gas chromatography mass spectrometry. The optimization of the SFE step shows that a static extraction period can be eliminated. The method gives good linearity (r = 0.991–0.999) and repeatability in the concentration range of 0.5 to 5 μg/mL. Relative standard deviations for oxprenolol, propanolol and metoprolol were less than 5% in serum and 5–11% in urine. Received: 23 May 1997 / Revised: 28 July 1997 / Accepted: 5 August 1997  相似文献   

12.
Marine biotoxins pose a significant food safety risk when bioaccumulated in shellfish, and adequate testing for biotoxins in shellfish is required to ensure public safety and long-term viability of commercial shellfish markets. This report describes the use of a benchtop Orbitrap system for liquid chromatography–mass spectrometry (LC-MS) screening of multiple classes of biotoxins commonly found in shellfish. Lipophilic toxins such as dinophysistoxins, pectenotoxins, and azaspiracids were separated by reversed phase LC in less than 7 min prior to MS data acquisition at 2 Hz with alternating positive and negative scans. This approach resulted in mass accuracy for analytes detected in positive mode (gymnodimine, 13-desmethyl spirolide C, pectenotoxin-2, and azaspiracid-1, -2, and -3) of less than 1 ppm, while those analytes detected in negative mode (yessotoxin, okadaic acid, and dinophysistoxin-1 and -2) exhibited mass errors between 2 and 4 ppm. Hydrophilic toxins such as domoic acid, saxitoxin, and gonyautoxins were separated by hydrophilic interaction LC (HILIC) in less than 4 min, and MS data was collected at 1 Hz in positive mode, yielding mass accuracy of less than 1 ppm error at a resolving power of 100,000 for the analytes studied (m/z 300–500). Data were processed by extracting 5 ppm mass windows centered around the calculated masses of the analytes. Limits of detection (LOD) for the lipophilic toxins ranged from 0.041 to 0.10 μg/L (parts per billion) for the positive ions, 1.6–5.1 μg/L for those detected in negative mode, while the domoic acid and paralytic shellfish toxins yielded LODs ranging from 3.4 to 14 μg/L. Toxins were detected in mussel tissue extracts free of interference in all cases.  相似文献   

13.
In the present work, a high-performance liquid chromatography–tandem mass spectrometry method has been developed for the residue analysis of chloramphenicol (CAP) in several food matrices. Following the addition of D5-CAP as internal standard, egg, honey, and milk were extracted and cleaned by means of solid-phase extraction, utilizing multi-walled carbon nanotubes as sorbent. The extracts were separated on a Halo fused-core C18 column (50 mm × 2.1 mm, 2.7 μm) and quantified by a 4000 Q-trap mass spectrometer equipped with a TurboIonSpray™ interface using electrospray ionization and multiple-reaction monitoring mode. The method validation was performed according to the criteria of Commission Decision 2002/657/EC. The decision limit (CCα) and detection capability (CCβ) of CAP in milk were calculated for m/z 320.8 > 151.9. Due to the existence of slight signal suppression, quantification was performed by matrix-matched calibration curves, ranging from 0.1 to 100 ng mL−1, with regression coefficients of 0.9993, 0.9998, and 0.9997 for egg, honey, and milk, respectively. Mean recoveries of the CAP ranged from 95.8% to 102.3%, with the corresponding intra- and inter-day variation (relative standard deviation) less than 7.13% and 8.89%, respectively. The limit of detection and limit of quantification of the method were also reported. This method successfully applied to several food matrixes (egg, honey, and milk) and can serve as a monitoring tool to avoid unacceptable levels of residues of CAP entering the food chain.  相似文献   

14.
Various extraction techniques can be combined with column liquid chromatography (LC) and ultraviolet (UV) or mass spectrometric (MS) detection for the determination of synthetic corticosteroids in biological matrices. Target analysis of low concentrations of 25 microg/kg of dexamethasone in feed can be performed by combining immunoaffinity chromatography (IAC) and LC with UV detection. A straightforward multi-analyte procedure is obtained by tandem solid-phase extraction (SPE) and subsequent LC-UV. However, the limits of detection for feed samples are then relatively poor, viz. 100 microg/kg. A multi-analyte method which meets modern demands of about 5 microg/kg detection limit requires one-step SPE combined with LC-MS analysis. As regards urine corticosteroids can be determined down to a level of 0.5 microg/l by either SPE-LC-MS- MS or SPE(IAC)-LC-MS.  相似文献   

15.
An EU project, FAIR5-CT-1997-3443, has been undertaken to distinguish illegal use of zeranol from consumption of food contaminated with Fusarium spp. toxin. One of the tasks was development of screening and confirmatory methods of analysis. This paper describes a new method based on two-step clean-up and GC–MS analysis. The first clean-up step is matrix-dependant; the second is applicable to both urine and meat. The MS is operated in negative chemical ionisation mode. The method is quantitative for zeranol and taleranol, α- and β-zearalenol, and zearalenone and qualitative for zearalanone. Validation was performed according to the latest EU performance criteria (Commission Decision 2002/657). For analysis of urine and for the method (μg L−1) were 0.06–0.11 for zeranol, 0.07–0.12 for taleranol, 0.07–0.11 for α-zearalenol, 0.21–0.36 for β-zearalenol, 0.35–0.60 for zearalenone, and 0.19–0.33 zearalanone. Within-laboratory reproducibility was 16.2, 11.2, 31.9, 30.1, 26.6, and 54.2% for zeranol, taleranol, α-zearalenol, β-zearalenol, zearalenone, and zearalanone, respectively. It was found that all the compounds are stable in urine at −20°C for at least a year. Part of the validation program was organisation of a small proficiency study (ringtest) and a correlation study with an LC–MS–MS method developed by the Veterinary Science Division (VSD; Belfast, UK-NI). This study showed there was good correlation between results from both laboratories. The method can be used for quantitative analysis discriminating illegal use of zeranol from consumption of zearalenone-contaminated food.  相似文献   

16.
This paper presents a general screening method, based on liquid chromatography/mass spectrometry (LC/MS), for the simultaneous detection in human urine of 72 xenobiotics (21 diuretics, 16 synthetic glucocorticoids, 17 beta-adrenergic drugs, 10 stimulants, 5 anti-oestrogens and 3 anabolic steroids), excreted free or as glucuro-conjugates in urine. Although the method has been specifically designed and evaluated in view of its potential application to anti-doping analyses, it can also be effective in other areas of analytical toxicology. Sample preparation was based on two liquid/liquid separation steps (performed at alkaline and at acid pH, respectively) of hydrolyzed human urine, and then an assay by LC/MS-MS in positive and negative ionization mode using an electrospray ionization source (ESI) and multiple reaction monitoring (MRM) as the acquisition mode. The overall time needed for an LC run was less than 15 minutes. All compounds showed good reproducibility in terms of both the retention times (CV%<1) and the relative abundances of the diagnostic transitions (CV%<10). The limits of detection (LOD) were in the range of 1–50 ng/mL for glucocorticoids, anti-oestrogens and steroids, and 50–500 ng/mL for diuretics, beta-adrenergic drugs and stimulants, thus satisfying the minimum required performance limits (MRPL) set by the World Anti-Doping Agency (WADA) for the accredited anti-doping laboratories.  相似文献   

17.
A 13-min LC–MS method was developed for the determination of daptomycin, a new potent antibiotic, in peritoneal fluid, blood plasma, and urine of patients receiving renal replacement therapy. Chromatography was performed on a C18 column and detection was performed by a single-quadrupole mass spectrometer coupled to LC via an electrospray interface (ESI). The column effluent was also monitored at 370 nm using a photodiode-array detector. The developed method provided a linear dynamic range for concentrations from 0.5 μg mL−1 to 100 μg mL−1. Method precision and accuracy were found to be satisfactory for clinical application, thus the method was successfully used for the analysis of daptomycin in pharmacokinetic studies. The drug was preventively administered against Gram-positive infections to 19 clinical patients undergoing peritoneal dialysis. Peritoneal fluid, blood plasma, and urine samples were collected at 13 time points over a period of 48 h. Clinical samples were analysed following simple sample-preparation procedures and daptomycin was unambiguously detected and quantified.  相似文献   

18.
Analysis of the major drugs of abuse in meconium has been established in clinical practice for detecting fetal exposure to illicit drugs, particularly for the ready availability of the sample and ease of collection from diapers, compared with neonatal hair and urine. Very little is known about the occurrence and detection possibilities of therapeutic and licit drugs in meconium. Meconium specimens (n = 209) were collected in delivery hospitals, from infants of mothers who were suspected to be drug abusers. A targeted analysis method by liquid chromatography–triple quadrupole mass spectrometry (LC-MS/MS) was developed for abused drugs: amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, morphine, codeine, 6-monoacetylmorphine, oxycodone, methadone, tramadol, buprenorphine, and norbuprenorphine. A separate LC-MS/MS method was developed for 11-nor-∆9-tetrahydrocannabinol-9-carboxylic acid. A screening method based on LC coupled to time-of-flight MS was applied to a broad spectrum of drugs. As a result, a total of 77 different compounds were found. The main drug findings in meconium were as follows: local anesthetics 82.5% (n = 172), nicotine or its metabolites 61.5% (n = 129), opioids 48.5% (n = 101), stimulants 21.0% (n = 44), hypnotics and sedatives 19.0% (n = 40), antidepressants 18.0% (n = 38), antipsychotics 5.5% (n = 11), and cannabis 3.0% (n = 5). By revealing drugs and metabolites beyond the ordinary scope, the present procedure helps the pediatrician in cases where maternal denial is strong but the infant seems to suffer from typical drug-withdrawal symptoms. Intrapartum drug administration cannot be differentiated from gestational drug use by meconium analysis, which affects the interpretation of oxycodone, tramadol, fentanyl, pethidine, and ephedrine findings.  相似文献   

19.
Quantification of F(2)-isoprostanes is considered a reliable index of the oxidative stress status in vivo. Several immunoassays and chromatography/mass spectrometry-based assays are available for 15-F(2t)-isoprostane quantification. However, it remains unclear if results of immunoassays using different assays can be compared with those of liquid chromatography/mass spectrometry (LC/MS) assays. Previous studies comparing enzyme-linked immunosorbent assay (ELISA) and more specific gas chromatography/mass spectrometry assays have already indicated that ELISAs may overestimate 15-F(2t)-isoprostane concentrations in human plasma. Concentrations of 15-F(2t)-isoprostane in 25 human plasma and urine samples were measured by three commercially available ELISA assays (Assay Designs, Cayman Chemical and Oxford Biomedical Research) and compared with the concentrations measured with a validated, semi-automated high-throughput HPLC tandem mass spectrometry assay (LC/LC-MS/MS). All three ELISAs measured substantially higher 15-F(2t)-isoprostane concentrations (2.1-182.2-fold higher in plasma; 0.4-61.9-fold higher in urine) than LC/LC-MS/MS. Utilization of solid-phase extraction (SPE) columns, especially isoprostane affinity purification columns, brought ELISA isoprostane urine concentrations closer to the LC/LC-MS/MS results. However, SPE did not have much of an effect on ELISA plasma concentrations which remained significantly higher than corresponding LC/LC-MS/MS results. A poor correlation not only between LC/LC-MS/MS and immunoassay results, but also among the immunoassays was found. Especially in plasma, ELISAs grossly overestimate 15-F(2t)-isoprostane concentrations and are not comparable with each other or with LC/LC-MS/MS. It is most disturbing that a sample with relatively high concentrations measured with one ELISA may show low concentrations with another ELISA, and vice versa, potentially affecting the conclusions drawn from such data. The use of specific mass spectrometry-based assays seems advisable.  相似文献   

20.
Benzylpiperazine (BZP) is an amphetamine-type stimulant, which was legally available in New Zealand and widely used in “Party Pills” until reclassification as a Class C drug in April 2008. BZP was included as part of a multi-analyte method developed for hair screening using high-performance liquid chromatography triple quadrupole mass spectrometry (LC-MS/MS). A 20-mg sample of hair is extracted and partially purified using mixed-mode solid-phase extraction cartridges prior to analysis by LC-MS/MS. The method was developed as a broad screen for drugs of abuse (including amphetamines, opiates, and benzodiazepines), with only the BZP results being presented here. The assay was validated and found to be linear over the range of 0.085 to 8.65 ng/mg with correlation coefficient of r 2 ≥ 0.99. Blank hair samples spiked with BZP at 0.22 and 2.16 ng/mg gave intra- and inter-day precision coefficients of variation of ≤10% (n = 6 per day, 3 days) at both levels and calculated extraction efficiencies of 78% and 91%, respectively. The results from the samples submitted to the laboratory for BZP analysis showed 11% were positive (n = 126). The mean BZP level was 3.9 ng/mg (range, 0.4–33 ng/mg; the result was extrapolated when above the calibration). These data are the first available showing the levels expected from users of BZP.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号