共查询到20条相似文献,搜索用时 0 毫秒
1.
The adenosine triphosphate (ATP) binding-cassette (ABC) transporters are a superfamily of cellular proteins that have been partly implicated as a cause of multidrug resistance (MDR) in cancer cells. The ABC superfamily consists of P-glycoprotein, multidrug resistance-associated proteins (MRP) and breast cancer-related proteins, of which MRP is of particular interest because of its ability to efflux a broader range of substrates. Since MRP1 is the most prominent member of the MRP family, a simple technique is needed for its quantification. We developed a simple, fast (total analysis time of 3h) capillary electrophoresis immunoassay (CEIA) for the quantification of MRP1 in cancer cells. MRP1 antibody was labeled with fluorescein isothiocyanate. The labeled antibody was incubated with the cell lysate for a fixed interval (1h), after which the cell lysate mixture was directly injected into the capillary to separate the complex of MRP1 and its antibody from free antibody. The noncompetitive CEIA method had a limit of detection of 0.2 nM and a good linear range (1.7-14.9×10(4) cells), and was fairly reproducible (RSD<10%). The results showed that two cell lines, A549 and RDES, expressed MRP1 in the absence of doxorubicin (DOX), with A549 registering a higher expression. Compared to DOX-free cancer cells, there was an acceleration of MRP1 expression during the 12h-exposure to DOX, after which the level of expression remained nearly constant as the intracellular accumulation of DOX decreased. The results obtained in this work indicate that the developed CEIA method is useful for relative quantification of MRPs in cancer cells. 相似文献
2.
Several computational approaches employ the high complementarity of plant miRNAs to target mRNAs as a filter to recognize miRNA. Numerous non-conserved miRNAs are known with more recent evolutionary origin as a result of target gene duplication events. We present here a computational model with knowledge inputs from reported non-conserved mature miRNAs of Oryza sativa (rice). Sequence- and structure-based approaches were used to retrieve miRNA features based on rice Argonaute protein and develop a multiple linear regression (MLR) model (r2 = 0.996, q2cv = 0.989) which scored mature miRNAs as predicted by the MaturePred program. The model was validated by scoring test set (q2 = 0.990) and computationally predicted mature miRNAs as external test set (q2test = 0.895). This strategy successfully enhanced the confidence of retrieving most probable non-conserved miRNAs from the rice genome. We anticipate that this computational model would recognize unknown non-conserved miRNA candidates and nurture the current mechanistic understanding of miRNA sorting to unveil the role of non-conserved miRNAs in gene silencing. 相似文献
3.
4.
In this article we present a novel droplet microfluidic chip enabling amplification-free detection of single pathogenic cells. The device streamlines multiple functionalities to carry out sample digitization, cell lysis, probe-target hybridization for subsequent fluorescent detection. A peptide nucleic acid fluorescence resonance energy transfer probe (PNA beacon) is used to detect 16S rRNA present in pathogenic cells. Initially the sensitivity and quantification abilities of the platform are tested using a synthetic target mimicking the actual expression level of 16S rRNA in single cells. The capability of the device to perform "sample-to-answer" pathogen detection of single cells is demonstrated using E. coli as a model pathogen. 相似文献
5.
The feasibility of microwave-accelerated derivatization for capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection was evaluated. The derivatization reaction was performed in a domestic microwave oven. Histidine (His), 1-methylhistidine (1-MH) and 3-methylhistidine (3-MH) were selected as test analytes and fluorescein isothiocyanate (FITC) was chosen as a fluorescent derivatizing reagent. Parameters that may affect the derivatization reaction and/or subsequent CE separation were systematically investigated. Under optimized conditions, the microwave-accelerated derivatization reaction was successfully completed within 150 s, compared to 4-24 h in a conventional water-bath derivatization process. This will remarkably reduce the overall analysis time and increase sample throughput of CE-LIF. The detection limits of this method were found to be 0.023 ng/mL for His, 0.023 ng/mL for 1-MH, and 0.034 ng/mL for 3-MH, respectively, comparable to those obtained using traditional derivatization protocols. The proposed method was characterized in terms of precision, linearity, accuracy and successfully applied for rapid and sensitive determination of these analytes in human urine. 相似文献
6.
In order to maintain a consistent supply of rice globally, control of pathogens affecting crop production is a matter of due concern. Rice yellow mottle virus(RYMV) is known to cause a variety of symptoms which can result in reduced yield. Four ORFs can be identified in the genome of RYMV encoding for P1 (ORF1), Polyprotein (processed to produce VPg, protease, helicase, RdRp4) (ORF2), putative RdRp (ORF3) and capsid/coat protein (ORF4). This research was aimed at identifying genome encoded miRNAs of O. sativa that are targeted to the genome of Rice Yellow Mottle Virus (RYMV). A consensus of four miRNA target prediction algorithms (RNA22, miRanda, TargetFinder and psRNATarget) was computed, followed by calculation of free energies of miRNA-mRNA duplex formation. A phylogenetic tree was constructed to portray the evolutionary relationships between RYMV strains isolated to date. From the consensus of algorithms used, a total of seven O. sativa miRNAs were predicted and conservation of target site was finally evaluated. Predicted miRNAs can be further evaluated by experiments involving the testing of the success of in vitro gene silencing of RYMV genome; this can pave the way for development of RYMV resistant rice varieties in the future. 相似文献
7.
8.
Casado-Terrones S Cortacero-Ramírez S Carrasco-Pancorbo A Segura-Carretero A Fernández-Gutiérrez A 《Analytical and bioanalytical chemistry》2006,386(6):1835-1847
The performance of two capillary electrophoresis (CE) instruments, one commercial and one homemade device, were compared for
the determination of derivatised aminated compounds with fluorescein isothiocyanate (FITC). The commercial CE system first
uses an argon ion laser as excitation source; the homemade CE device uses an inexpensive blue-light-emitting diode (LED) as
the light source and a charge-coupled device (CCD) as the detection system. After fine optimisation of several separation
parameters in both devices, a co-electroosmotic flow CE methodology was achieved in coated capillary tubing with 0.001% hexadimetrine
bromide (HDB), and 50 mmol L−1 sodium borate at pH 9.3 with 20% 2-propanol for the determination of several amines and aminoacids. Analytical performances,
applicability in beer samples and other aspects such as cost or potential for miniaturization have been compared for both
devices. 相似文献
9.
10.
Capillary array electrophoresis (CAE) is an important high throughput analytical technique. Laser-induced fluorescence (LIF) has been the dominant detection method for CAE owing to its low limit of detection (LOD) and wide linear dynamic range (LDR). Linear LIF scanners were first used in CAE because linear motions of an objective match well with a common planar array of capillaries. A problem with linear scanners is that the motor is required accelerating/decelerating so that all capillaries can be properly scanned, which makes motion control complicated and reduces the duty cycle. Rotary scanners were developed to overcome this problem. While rotary scanners have been successfully applied in CAE, the capillaries have to be arranged in a circular format, which can be inconvenient in some cases. In this report, we describe a cam-based LIF scanner as an alternative technique for CAE detection. In this system, a rotary motor is mechanically linked with a capillary holder via a cam. During operation, the motor carries the cam in a rotary motion that drives an array of capillaries on the holder to move back and forth across the objective for fluorescence detection. Using this design, the capillaries can be parallel-arranged in a plane while the motor acceleration/deceleration is avoided. To demonstrate the feasibility of this approach, we constructed a prototype instrument with a constant-velocity scanning distance of ∼10 mm, a scanning frequency of 3 Hz and a duty cycle of ∼70%. The scanner exhibited a LOD of 69 pM of fluorescein and a LDR of 3.5 orders of magnitude. Multiplexed capillary SDS-PAGE was performed on this scanner for protein separations. 相似文献
11.
A unique laser-induced fluorescence (LIF) reader equipped with a turbidimetric system was developed for a sandwich-type immunoassay using nanoparticles. The system was specifically designed to reduce experimental error caused by particle loss, aggregation and sinking, and to improve analytical performance through ratiometric measurement of the fluorescence with respect to the turbidimetric absorbance. For application to determine the concentration of salinomycin, magnetic nanoparticles (MNPs) and FITC-doped silica nanoparticles (colored balls) immobilized with antibody were synthesized for magnetic extraction and for tagging as a fluorescence probe, respectively. The detection limit of about 39 pg mL−1 was obtained, which was an improvement of about 2-fold compared to that obtained without employment of the turbidimetric system. Calibration linearity and sensitivity were also improved, with increase from 0.8601 to 0.9905 in the R2-coefficient and by 1.92-fold for the curve slope, respectively. The developed LIF reader has the potential to be used for fluorescence measurements using various nanomaterials, such as quantum dots. 相似文献
12.
An improved automated continuous sample introduction system for microfluidic capillary electrophoresis (CE) is described. A sample plate was designed into gear-shaped and was fixed onto the shaft of a step motor. Twenty slotted reservoirs for containing samples and working electrolytes were fabricated on the “gear tooth” of the plate. A single 7.5-cm long Teflon AF-coated silica capillary serves as separation channel, sampling probe, as well as liquid-core waveguide (LCW) for light transmission. Platinum layer deposited on the capillary tip serves as the electrode. Automated continuous sample introduction was achieved by scanning the capillary tip through the slots of reservoirs. The sample was introduced into capillary and separated immediately in the capillary with only about 2-nL gross sample consumption. The laser-induced fluorescence (LIF) method with LCW technique was used for detecting fluorescein isothiocyanate (FITC)-labeled amino acids. With electric-field strength of 320 V/cm for injection and separation, and 1.0-s sample injection time, a mixture of FITC-labeled arginine and leucine was separated with a throughput of 60/h and a carryover of 2.7%. 相似文献
13.
Blank problems in the detection of gold by electrothermal atomisation and laser-induced fluorescence
H. Beissler G. A. Petrucci P. Cavalli N. Omenetto 《Spectrochimica Acta Part B: Atomic Spectroscopy》1999,54(14):2115-2120
The limit of detection of gold by electrothermal atomisation and double-resonance laser-induced atomic fluorescence can reach the low femtogram level as absolute amount of gold deposited in the furnace. At these high sensitivities, even dry firings of the graphite tube may result in a signal, which is unequivocally attributed to atomic fluorescence of the gold content of the tube released during atomisation. The occurrence and the analytical relevance of such blank signals are presented and discussed in this note. 相似文献
14.
Lapainis T Scanlan C Rubakhin SS Sweedler JV 《Analytical and bioanalytical chemistry》2007,387(1):97-105
A laser-induced native fluorescence detection system optimized for analysis of indolamines and catecholamines by capillary
electrophoresis is described. A hollow-cathode metal vapor laser emitting at 224 nm is used for fluorescence excitation, and
the emitted fluorescence is spectrally distributed by a series of dichroic beam-splitters into three wavelength channels:
250–310 nm, 310–400 nm, and >400 nm. A separate photomultiplier tube is used for detection of the fluorescence in each of
the three wavelength ranges. The instrument provides more information than a single-channel system, without the complexity
associfated with a spectrograph/charge-coupled device-based detector. With this instrument, analytes can be separated and
identified not only on the basis of their electrophoretic migration time but also on the basis of their multichannel signature,
which consists of the ratios of relative fluorescence intensities detected in each wavelength channel. The 224-nm excitation
channel resulted in a detection limit of 40 nmol L−1 for dopamine. The utility of this instrument for single-cell analysis was demonstrated by the detection and identification
of the neurotransmitters in serotonergic LPeD1 and dopaminergic RPeD1 neurons, isolated from the central nervous system of
the well-established neurobiological model Lymnaea stagnalis. Not only can this system detect neurotransmitters in these individual neurons with S/N>50, but analyte identity is confirmed on the basis of spectral characteristics.
Lapainis and Scanlan contributed equally to this work. 相似文献
15.
在有源发光玻璃的制备过程中,通常需要掺杂微量元素,用于改善玻璃的发光性能,因此在生产过程中进行快速检测非常重要.本实验针对激光诱导击穿光谱技术(LIBS)分析玻璃中微量元素灵敏度不足的问题,利用激光诱导荧光辅助激光诱导击穿光谱技术(LIBS-LIF)检测了玻璃中3种微量元素Yb,Al和P.使用波长可调谐激光激发等离子体中的Yb+离子、Al原子和P原子,并对这3种粒子在激光诱导荧光中的跃迁过程进行了分析.结果表明,通过激光诱导荧光辅助激光诱导击穿光谱技术,Yb+离子、Al原子和P原子的光谱强度分别增强了23,50和8倍,大幅度提高了LIBS分析的灵敏度. 相似文献
16.
A laser-induced fluorescence microscopic system based on optical parametric oscillation has been constructed as a tunable detector for microchip analysis. The detection limit of sulforhodamine B (Ex. 520 nm, Em. 570 nm) was 0.2 mol, which was approximately eight orders of magnitude better than with a conventional fluorophotometer. The system was applied to the determination of fluorescence-labeled DNA (Ex. 494 nm, Em. 519 nm) in a microchannel and the detection limit reached a single molecule. These results showed the feasibility of this system as a highly sensitive and tunable fluorescence detector for microchip analysis. 相似文献
17.
《化学:亚洲杂志》2017,12(15):1895-1899
We report a fast and sensitive method for the multiplexed detection of miRNAs by combining mass signal amplification and isotope‐labeled signal reporter molecules. In our strategy, target miRNAs are captured specifically by immobilized DNAs on gold nanoparticles (AuNPs), which carry a large number of small molecules, called amplification tags (Am‐tags), as the reporter for the detection of target miRNAs. For multiplexed detection, we designed and synthesized four Am‐tags containing 0, 4, 8, 12 isotopes so that they had same molecular properties but different molecular weights. By observing the mass signals of the Am‐tags on AuNPs decorated along with different probe DNAs, four types of miRNAs in a sample could be easily discriminated, and the relative amounts of these miRNAs could be quantified. The practicability of our strategy was further verified by measuring the expression levels of two miRNAs in HUVECs in response to different CuSO4 concentrations. 相似文献
18.
Valerie A. Frerichs Jennifer K. Herrmann Alfredo Aguirre Luis A. Coln 《Microchemical Journal》2004,78(2):135-142
An analytical method was developed to determine the undecapetide substance P (SP) based on capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection. SP was derivatized with the fluorogenic reagent 2,3-naphthalenedicarboxaldehyde (NDA) prior to injection into the CE-LIF system. The pre-column derivatization scheme combined with injection enhancement techniques extends the detectability of SP to the subnanomolar level. Limit of detection (LOD) of 100 pM was achieved without pre-concentrating the sample prior to injection. The reproducibility for six different preparations of a standard sample containing 5 nM of SP was 6.8% RSD and that of the CE migration time was 0.08% RSD. The method was used to determine SP in a saliva sample. 相似文献
19.
Melissa N. Dunkle 《Microchemical Journal》2006,82(1):100-107
A fluorescein-labeled estradiol derivative was assessed for use in affinity capillary electrophoresis (ACE) in a competitive immunoassay format, in which the fluorescently labeled estradiol competed with unlabeled estradiol for a mouse anti-estradiol antibody. The preparation of the labeled estradiol produced a mixture of fluorescein-containing compounds that led to multiple peaks in the electropherogram and to which the antibody responded differently. Two of the components of the mixture, towards which the mouse antibody showed most affinity, were isolated using fraction collection via capillary electrophoresis (CE). The two fractions of the labeled estradiol products isolated by CE were characterized using mass spectrometric methods. The two active fluorescein-conjugated products differed in the carboxylate on the fluorescein moiety, one having a methyl group instead of the acidic hydrogen for the other. The estradiol antibody showed a stronger binding for the conjugate containing the methyl group, as determined from the estimated binding constants using Scatchard analysis. The isolated fractions of labeled estradiol were shown to be applicable to the ACE immunoassay method. 相似文献
20.
Lilian Cristina Trevizan Dário Santos Jr. Ricardo Elgul Samad Nilson Dias Vieira Jr. Lidiane Cristina Nunes Iolanda Aparecida Rufini Francisco José Krug 《Spectrochimica Acta Part B: Atomic Spectroscopy》2009
Laser induced breakdown spectroscopy (LIBS) has been evaluated for the determination of micronutrients (B, Cu, Fe, Mn and Zn) in pellets of plant materials, using NIST, BCR and GBW biological certified reference materials for analytical calibration. Pellets of approximately 2 mm thick and 15 mm diameter were prepared by transferring 0.5 g of powdered material to a 15 mm die set and applying 8.0 tons cm− 2. An experimental setup was designed by using a Nd:YAG laser operating at 1064 nm (200 mJ per pulse, 10 Hz) and an Echelle spectrometer with ICCD detector. Repeatability precision varied from 4 to 30% from measurements obtained in 10 different positions (8 laser shots per test portion) in the same sample pellet. Limits of detection were appropriate for routine analysis of plant materials and were 2.2 mg kg− 1 B, 3.0 mg kg− 1 Cu, 3.6 mg kg− 1 Fe, 1.8 mg kg− 1 Mn and 1.2 mg kg− 1 Zn. Analysis of different plant samples were carried out by LIBS and results were compared with those obtained by ICP OES after wet acid decomposition. 相似文献