首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
本文基于适配体识别和生物条形码放大策略,以MCF-7细胞和粘蛋白(MUC1)为目标物,MUC1的特异性适配体(rcDNA)为分子识别物质,Ru(phen)32+为信号物质,rcDNA通过巯基自组装于金电极表面作为传感界面,发卡DNA (hpDNA)和rcDNA通过巯基自组装在金纳米粒子(AuNP)表面合成的hpDNA/...  相似文献   

2.
A novel strategy for selective collection and detection of breast cancer cells (MCF-7) based on aptamer–cell interaction was developed. Mucin 1 protein (MUC1) aptamer (Apt1) was covalently conjugated to magnetic beads to capture MCF-7 cell through affinity interaction between Apt1 and MUC1 protein that overexpressed on the surface of MCF-7 cells. Meanwhile, a nano-bio-probe was constructed by coupling of nucleolin aptamer AS1411 (Apt2) to CdTe quantum dots (QDs) which were homogeneously coated on the surfaces of monodispersed silica nanoparticles (SiO2 NPs). The nano-bio-probe displayed similar optical and electrochemical performances to free CdTe QDs, and remained high affinity to nucleolin overexpressed cells through the interaction between AS1411 and nucleolin protein. Photoluminescence (PL) and square-wave voltammetric (SWV) assays were used to quantitatively detect MCF-7 cells. Improved selectivity was obtained by using these two aptamers together as recognition elements simultaneously, compared to using any single aptamer. Based on the signal amplification of QDs coated silica nanoparticles (QDs/SiO2), the detection sensitivity was enhanced and a detection limit of 201 and 85 cells mL−1 by PL and SWV method were achieved, respectively. The proposed strategy could be extended to detect other cells, and showed potential applications in cell imaging and drug delivery.  相似文献   

3.
An ultrasensitive aptamer-based bio bar code immunomagnetic separation and electrochemiluminescence (IM-ECL) method for the detection of protein is developed. The target protein is captured by biotin-labeled aptamer (biotin probe) and [Ru(bpy)3]2+ (TBR)-Au bio bar code-labeled aptamer (ECL nanoprobe), to form a double aptamer–protein sandwich complex. The complex is then immobilized on the streptavidin microbeads through biotin–streptavidin linkage and detected by ECL assay. The ECL signal of the target protein is amplified by the TBR-bio bar code DNAs. As an example, platelet-derived growth factor B-chain homodimer (PDGF-BB) was detected by the method. Experimental results show that the detection limit of the assay is 1 pM of PDGF-BB. A calibration curve with a linearity range from 1 pM to 10 nM is established, thus, make quantitative analysis possible. The method has been used to detect PDGF-BB in fetal calf serum with minimum background interference. Due to the wide availability of aptamer for numerous proteins, this aptamer-based bio bar code IM-ECL method holds great promise in protein detection.  相似文献   

4.
王晓飞  张婷  王冰  漆红兰  张成孝 《电化学》2019,25(2):223-231
基于点击化学和重氮盐法的双共价键固定化方法,制备了一种高灵敏、可重复使用的电化学发光(ECL)适体传感器. 该方法以可卡因为分析物,以可卡因适体为分子识别物质,以钌联吡啶衍生物为ECL信号物质. 采用电化学方法在玻碳电极表面重氮化叠氮苯胺,通过点击反应连接炔基功能化的钌联吡啶衍生物标记可卡因适体,获得适体传感器. 该传感器在共反应剂存在下,产生弱的电化学发光信号,可卡因存在下,电化学发光信号增加. 基于此,建立了“信号增强”型检测可卡因的电化学发光分析新方法. 电化学发光信号与可卡因浓度在0.1 nmol·L-1 ~ 100 nmol·L-1范围内呈良好的线性关系,检出限为60 pmol·L-1. 该传感器具有良好的稳定性,可重复多次使用. 该双共价键法在构建ECL传感器方面具有很好的应用前景.  相似文献   

5.
Two simple and sensitive electrochemical approaches for Mucin1 (MUC1) tumor marker using magnetic beads coupling screen‐printed arrays were developed. The single‐use bioassays are based on a sandwich format in which aptamers or antibodies were coupled respectively to Streptavidin or Protein G‐modified magnetic beads. The bioreceptor‐modified beads are used to capture the MUC1 protein from the sample and sandwich assay is performed by the addition of a labeled secondary aptamer or antibody. The enzyme alkaline phosphatase and its substrate (1‐naphthyl phosphate) are then used for the electrochemical detection by differential pulse voltammetry (DPV). The analytical performances of the designed bioassays were compared in terms of sensitivity, selectivity and reproducibility. Using the optimized conditions, a linear range from 0 to 0.28 nM was obtained, with 0.19 nM LOD using antibody‐based and 0.07 nM LOD using aptamer‐based sandwich assay in MUC1 buffered solutions. The results also showed that the aptamer‐based approach exhibited higher selectivity for MUC1, allowing the detection of the protein in complex matrices. The developed aptasensor for MUC1 detection was applied on serum samples obtained from cancer patients, providing promising perspectives for clinical applications.  相似文献   

6.
A novel electrochemiluminescence (ECL) aptasensor was proposed for sensitive and cost-effective detection of the target thrombin adopted an aptamer-based sandwich format. To detect thrombin, capture aptamers labeled with gold nanoparticles (AuNPs) were first immobilized onto the thio-silanized ITO electrode surface through strong Au-S bonds. After catching the target thrombin, signal aptamers tagged with ECL labels were attached to the assembled electrode surface. As a result, an AuNPs-capture-aptamer/thrombin/ECL-tagged-signal-aptamer sandwich type was formed. Treating the resulting electrode surface with tri-n-propylamine (TPA) and applying a swept potential to the electrode, ECL response was generated which realized the detection of target protein. Spectroscopy and electrochemical impedance techniques were used to characterize and confirm the fabrication of the ECL aptasensor. AuNPs amplification and smart sensor fabrication art were implemented for the sensitive and cost-effective detection purpose. Signal-to-dose curve excellently followed a sandwich format equation and could be used to quantify the protein, and the detection limit was estimated to be 10 nM. Other forms of thrombin such as β- and γ-thrombins had negligible response, which indicated a high specificity of α-thrombin detection. The aptasensor opened up new fields of aptamer applications in ECL domain, a highly sensitive technique, and had a promising perspective to be applied in microarray analysis.  相似文献   

7.
A solid-state electrochemiluminescence sensing platform based on ferrocene-labeled structure-switching signaling aptamer (Fc-aptamer) for highly sensitive detection of small molecules is developed successfully using adenosine as a model analyte. Such special sensing platform included two main parts, an electrochemiluminescence (ECL) substrate and an ECL intensity switch. The ECL substrate was made by modifying the complex of Au nanoparticle and Ruthenium (II) tris-(bipyridine) (Ru(bpy)32+-AuNPs) onto Au electrode. An anti-adenosine aptamer labeled by ferrocene acted as the ECL intensity switch. A short complementary ssDNA for the aptamer was applied to hybridizing with the aptamer, yielding a double-stranded complex of the aptamer and the ssDNA on the electrode surface. The introduction of adenosine triggered structure switching of the aptamer. As a result, the ssDNA was forced to dissociate from the sensing platform. Such structural change of the aptamer resulted in an obvious ECL intensity decrease due to the increased quenching effect of Fc to the ECL substrate. The analytic results were sensitive and specific.  相似文献   

8.
构建了一种可再生型三磷酸腺苷(ATP)适配体计时库仑电化学传感器.将一条短链DNA通过AuS键自组装固定在电极表面, ATP的核酸适配体与该短链DNA杂交而结合在电极表面.带负电的DNA通过静电吸引结合电解液中的六氨合钌(RuHex)阳离子.当传感器和靶分子ATP孵育后,ATP与核酸适配体结合,使适配体链从电极表面解离,电极表面吸附的DNA量减少,结合RuHex的量随之降低.通过计时库仑技术检测RuHex响应信号降低的量 ,可以对ATP进行定量测定.此传感器的电化学响应信号与ATP浓度对数值呈线性关系,线性检测范围为0.001~100 μmol/L,检出限(S/N=3)为0.5 nmol/L.此传感器检测靶分子ATP后,可以通过简单的操作步骤再生,再生5次后的响应信号为初始信号的90%以上.采用此传感器检测大鼠脑透析液中ATP的含量为(19.2±3.7) nmol/L (n=3).  相似文献   

9.
An ultrasensitive and signal‐on electrochemiluminescence (ECL) aptasensor to detect target protein (thrombin or lysozyme) was developed using the host‐guest recognition between a metallocyclodextrin complex and single‐stranded DNA (ss‐DNA). The aptasensor uses both the photoactive properties of the metallocyclodextrins named multi‐tris(bipyridine)ruthenium(II)‐β‐cyclodextrin complexes and their specific recognition with ss‐DNA, which amplified the ECL signal without luminophore labeling. After investigating the ECL performance of different multi‐tris(bipyridine)ruthenium(II)‐β‐cyclodextrin (multi‐Ru‐β‐CD) complexes, tris‐tris(bipyridine)‐ruthenium(II)‐β‐cyclodextrin (tris(bpyRu)‐β‐CD) was selected as a suitable host molecule to construct an atasensor. First, double‐stranded DNA (ds‐DNA) formed by hybridization of the aptamer and its target DNA was attached to a glassy carbon electrode via coupling interaction, which showed low ECL intensity with 2‐(dibutylamino) ethanol (DBAE) as coreactant, because of the weak recognition between ds‐DNA and tris(bpyRu)‐β‐CD. Upon addition of the corresponding protein, the ECL intensity increased when target ss‐DNA was released because of the higher stability of the aptamer‐protein complex than the aptamer‐DNA one. A linear relationship was observed in the range of 0.01 pmol/L to 100 pmol/L between ECL intensity and the logarithm of thrombin concentrations with a limited detection of 8.5 fmol/L (S/N=3). Meanwhile, the measured concentration of lysozyme was from 0.05 pmol/L to 500 pmol/L and the detection limit was 33 fmol/L (S/N=3). The investigations of proteins in human serum samples were also performed to demonstrate the validity of detection in real clinical samples. The simplicity, high sensitivity and specificity of this aptasensor show great promise for practical applications in protein monitoring and disease diagnosis.  相似文献   

10.
A sensitive electrochemiluminescence (ECL) biosensor for the specific DNA sequence of hepatitis C virus (HCV) was developed based on the efficient quenching effect of the ferrocene cluster functionalized gold nanoparticles (Fc@AuNPs) on the ECL of electrodeposited silica@Ru(bpy)32+-chitosan-graphene oxide nanocomposite (SiO2@Ru−CS−GO). Graphene oxide (GO) can accelerate electron transfer rate, thus improving the ECL of Ru(bpy)32+ on electrode surface. The molecular beacons (MB) was fixed to SiO2@Ru−CS−GO by glutaraldehyde (GA) using the Schiff reaction between amino groups of chitosan (CS) and MB. The ECL of SiO2@Ru−CS−GO was depressed greatly by the Fc@AuNPs labelled at the end of MB, then, a stronger ECL was observed when the distance between Fc@AuNPs and SiO2@Ru−CS−GO increased after the hybridization of target DNA with MB. Under optimum conditions, the restored ECL intensity increased linearly with the target DNA concentration in the range of 1.0×10−16∼1.0×10−10 mol ⋅ L−1, and the limit of detection (LOD) is 1.4×10−17 mol ⋅ L−1. The proposed method exhibits acceptable stability and reproducibility. In general, the constructed HCV biosensor can be used for the sensitive detection of HCV in human serum, suggesting potential application prospects in bioanalysis.  相似文献   

11.
A novel [Ru(bpy)2(dcbpy)NHS] labeling/aptamer‐based biosensor combined with gold nanoparticle amplification for the determination of lysozyme with an electrochemiluminescence (ECL) method is presented. In this work, an aptamer, an ECL probe, gold nanoparticle amplification, and competition assay are the main protocols employed in ECL detection. With all the protocols used, an original biosensor coupled with an aptamer and [Ru(bpy)2(dcbpy)NHS] has been prepared. Its high selectivity and sensitivity are the main advantages over other traditional [Ru(bpy)3]2+ biosensors. The electrochemical impedance spectroscopy (EIS) and atomic force microscopy (AFM) characterization illustrate that this biosensor is fabricated successfully. Finally, the biosensor was applied to a displacement assay in different concentrations of lysozyme solution, and an ultrasensitive ECL signal was obtained. The ECL intensity decreased proportionally to the lysozyme concentration over the range 1.0×10?13–1.0×10?8 mol L?1 with a detection limit of 1.0×10?13 mol L?1. This strategy for the aptasensor opens a rapid, selective, and sensitive route for the detection of lysozyme and potentially other proteins.  相似文献   

12.
Wang X  Zhou J  Yun W  Xiao S  Chang Z  He P  Fang Y 《Analytica chimica acta》2007,598(2):242-248
A sensitive and selective aptasensor using tri(2,2′-bipyridyl)ruthenium(II)-doped silica nanoparticles (Ru(bpy)32+-doped SNPs) as DNA tags for detection of thrombin is developed based on the target protein-induced strand displacement of the DNA probe. For the proposed aptasensor, the aptamer was assembled on the surface of the Au electrode through Au-S binding. The hybridization event between the DNA probe labeled by the Ru(bpy)32+-doped SNPs and the aptamer was evaluated by electrogenerated chemiluminescence (ECL) measurements. Then, the DNA probe was displaced by thrombin and the binding event between the thrombin and the aptamer was monitored by ECL measurements again. The difference of ECL intensity (ΔIECL) of the two events could be used to quantify the thrombin. Other proteins, such as bovine serum albumin and bovine hemoglobin, had almost negligible ΔIECL. Under the optimal conditions, the ΔIECL was linearly related to the concentration of the thrombin in the range of 10 fM to 10 pM and the detection limit was down to 1.0 fM since SNPs containing a large number of Ru(bpy)32+ molecules were labeled on the DNA probe.  相似文献   

13.
In this study, we for the first time presented an efficient, accurate, rapid, simple and ultrasensitive detection system for small molecule ochratoxin A (OTA) by using the integration of loop-mediated isothermal amplification (LAMP) technique and subsequently direct readout of LAMP amplicons with a signal-on electrochemiluminescent (ECL) system. Firstly, the dsDNA composed by OTA aptamer and its capture DNA were immobilized on the electrode. After the target recognition, the OTA aptamer bond with target OTA and subsequently left off the electrode, which effectively decreased the immobilization amount of OTA aptamer on electrode. Then, the remaining OTA aptamers on the electrode served as inner primer to initiate the LAMP reaction. Interestingly, the LAMP amplification was detected by monitoring the intercalation of DNA-binding Ru(phen)32+ ECL indictors into newly formed amplicons with a set of integrated electrodes. The ECL indictor Ru(phen)32+ binding to amplicons caused the reduction of the ECL intensity due to the slow diffusion of Ru(phen)32+–amplicons complex to the electrode surface. Therefore, the presence of more OTA was expected to lead to the release of more OTA aptamer, which meant less OTA aptamer remained on electrode for producing LAMP amplicons, resulting in less Ru(phen)32+ interlaced into the formed amplicons within a fixed Ru(phen)32+ amount with an obviously increased ECL signal input. As a result, a detection limit as low as 10 fM for OTA was achieved. The aptasensor also has good reproducibility and stability.  相似文献   

14.
Liu DY  Xin YY  He XW  Yin XB 《The Analyst》2011,136(3):479-485
Electrochemiluminescence (ECL)-based biosensors are often used in the field of DNA- and protein-assay. Although ruthenium complex-based ECL is sensitive, its high exciting potential may lead to oxidation damage to biomolecules. For the first time, a non-damaging, low potential ECL aptasensor was constructed for bioassay with lysozyme as a model. After a single-stranded anti-lysozyme aptamer was attached to a gold electrode, a double stranded (ds)-DNA formed with its complementary strand. Ru(phen)(3)(2+), as an ECL probe, was intercalated into the ds-DNA. The hybridization of lysozyme with its aptamer led to the dissociation of ds-DNA because of the high stability of the aptamer-lysozyme and therefore the Ru(phen)(3)(2+) intercalated into ds-DNA was released. A low potential ECL was observed at the ds-DNA-modified electrode because ds-DNA was able to preconcentrate tripropylamine (TPA) and acted as the acceptor of the protons released from protonated TPAH(+). While the DNA sequence (anti-lysozyme aptamer) was used as the special recognition element for lysozyme, the formed ds-DNA also provided a micro-environment for low potential ECL. The low potential ECL aptasensor achieved the determination of lysozyme with a detection limit of 0.45 pM. The day-to-day precision (RSDs, n = 5) for the determination of lysozyme was lower than 5%, showing the reliability of the aptasensor. The regeneration of the aptasensor confirmed that the low potential for ECL could decrease oxidation damage to biomolecules. Further, the proposed method was successfully used to analyze diluted egg white sample directly. The protocol exhibited a promising platform for sensitive bioassay and could be further applied for the development of other low potential ECL sensing systems.  相似文献   

15.
One solid-state electrochemiluminescence(ECL) protein biosensor based on the competing reaction and substitute reaction between protein-to-DNA aptamer and DNA-to-DNA aptamer was proposed.Additionally,the biosensor was based on ECL photo-quenching effect of ferrocene(Fc) to tris(2,2'-bipyridyl)ruthenium(II)(Ru(bpy)32+).It was built up by modification of Au nanoparticles(AuNPs) and Ru(bpy)3 2+ on one Au electrode firstly,and then self-assembly of one special double-stranded DNA(dsDNA) onto the electrode.This ...  相似文献   

16.
本文应用核酸适配体构建了一种新型的电致化学发光检测蛋白体系。两个核酸适配体结合凝血酶的两个不同位点,利用这两核酸适配体与凝血酶的高亲和力构建三明治传感体系检测凝血酶。一个核酸适配体固定在金电极上用来捕获凝血酶,另一个标记有包裹电致化学发光活性物Ru(bpy)32+的二氧化硅纳米颗粒,用来检测电致化学发光信号。此核酸适配体传感器对凝血酶具有特异识别性,电致化学发光信号与凝血酶的浓度直接相关,非特异性识别的牛血红蛋白、牛血清白蛋白不干扰测定。由于在检测的核酸适配体上标记的纳米颗粒包裹有多个发光活性物,因此大大提高了发光效率和灵敏度,此法对凝血酶的线性响应范围为2.0 fmol•L-1~2.0 pmol•L-1,检测限可达1.0 fmol•L-1。  相似文献   

17.
The electrochemiluminescence (ECL) aptasensor was prepared for the detection of Mucin 1 based on its specific recognition by aptamer immobilized on multi‐functionalized graphene oxide nanocomposite, which was prepared with N‐(4‐aminobutyl)‐N‐ethylisoluminol (ABEI) and aptamer chemically bound to the surface of magnetic GO (nanoFe3O4@GO). ABEI and aptamer acted as the electrochemiluminophore and the capture device for Mucin 1 respectively. NanoFe3O4@GO brought multi‐functionalized graphene oxide nanocomposite attracted on the surface of magnetic glass carbon electrode through magnetism, enabled all the ABEI immobilized electrochemically active due to its good conductivity and thus then facilitated the sensitive detection of Mucin 1. In addition, the ECL aptasensor can be prepared through a one‐step process. Under optimal conditions, the ECL intensity of the aptasensor decreased proportionally to the logarithmic concentrations of Mucin 1 in the range of 0.005–1000 ng mL?1. This aptasensor displays good specificity, stability, reproducibility and application. This method has a large potential because such a multi‐functionalized graphene oxide nanocomposite also may be applied to other ECL‐based aptasensors.  相似文献   

18.
The electrochemical and electrochemiluminescence (ECL) detection of cell lines of Burkitt’s lymphoma (Ramos) by using magnetic beads as the separation tool and high‐affinity DNA aptamers for signal recognition is reported. Au nanoparticles (NPs) bifunctionalized with aptamers and CdS NPs were used for electrochemical signal amplification. The anodic stripping voltammetry technology employed for the analysis of cadmium ions dissolved from CdS NPs on the aggregates provided a means to quantify the amount of the target cells. This electrochemical method could respond down to 67 cancer cells per mL with a linear calibration range from 1.0×102 to 1.0×105 cells mL?1, which shows very high sensitivity. In addition, the assay was able to differentiate between target and control cells based on the aptamer used in the assay, indicating the wide applicability of the assay for diseased cell detection. ECL detection was also performed by functionalizing the signal DNA, which was complementary to the aptamer of the Ramos cells, with tris(2,2‐bipyridyl) ruthenium. The ECL intensity of the signal DNA, replaced by the target cells from the ECL probes, directly reflected the quantity of the amount of the cells. With the use of the developed ECL probe, a limit of detection as low as 89 Ramos cells per mL could be achieved. The proposed methods based on electrochemical and ECL should have wide applications in the diagnosis of cancers due to their high sensitivity, simplicity, and low cost.  相似文献   

19.
A novel aptamer biosensor for cancer cell assay has been reported on the basis of ultrasensitive electrochemical detection. The assay uses the aptamer as a capture probe to recognize and bind the tumor marker on the surface of the cancer cells, forming an aptamer-based sandwich structure for MCF-7 cells detection. Functionalized nanoporous materials, porous graphene oxide/Au composites (GO/Au composites) and porous PtFe alloy have been introduced into the biosensor. Owing to the large surface area and versatile porous structure, the use of nanoporous materials can significantly improve the analysis performance of the biosensors by loading of large amounts of molecules and accelerating diffusion rate. Under the optimized experimental conditions, the proposed aptamer biosensor exhibited excellent analytical performance for MCF-7 cells determination, ranging from 100 to 5.0 × 107 cells mL−1 with the detection limit of 38 cells mL−1. The biosensor showed good selectivity, acceptable stability and reproducibility, and developed a highly sensitive and selective method for cancer cells detection.  相似文献   

20.
The detection of biomarkers is of great significance in the diagnosis of numerous diseases,especially cancer.Herein,we developed a sensitive and universal fluorescent aptasensor strategy based on magnetic beads,DNA G-quadruplex,and exonuclease Ⅲ(Exo Ⅲ).In the presence of a target protein,a label-free single strand DNA(ssDNA)hybridized with the aptamer was released as a trigger DNA due to specific recognition between the aptamer and target.Subsequently,ssDNA initiates the ExoⅢ-aided recycling to amplify the fluorescence signal,which was caused by N-methylmesoporphyrin IX(NMM)insertion into the G-quadruplex structure.This proposed strategy combines the excellent specificity between the aptamer and target,high sensitivity of the fluorescence signal by G-quadruplex and ExoⅢ-aided recycling amplification.We selected(50-1200 nmol/L)MUC1,a common tumor biomarker,as the proof-of-concept target to test the specificity of our aptasenso r.Results reveal that the sensor sensitively and selectively detected the target protein with limits of detection(LODs)of 3.68 and 12.83 nmol/L in buffer solution and 10%serum system,respectively.The strategy can be easily applied to other targets by simply substituting corresponding aptamers and has great potential in the diagnosis and monitoring of several diseases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号