首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Gas chromatography (GC) coupled to mass spectrometry (MS) operated in selected ion monitoring (SIM) mode is currently the method of choice for the determination of the toxic contaminant ethyl carbamate in alcoholic beverages. However, even after extensive sample cleanup over diatomaceous earth columns, the identity of ethyl carbamate often cannot be ascertained with confidence, due to inconsistent ratios of the SIM ions m/z 62, 74 and 44 because the qualifier ions are highly susceptible to interferences. Therefore, a new method combining GC and tandem MS using a triple-quadrupole instrument is introduced to determine ethyl carbamate in stone-fruit spirits. For quantitative analysis the characteristic transitions of m/z 74 --> 44 and m/z 62 --> 44 for ethyl carbamate as well as m/z 64 --> 44 for the deuterated internal standard ethyl carbamate-d5 were monitored in the multiple reaction monitoring (MRM) mode. In the validation studies, ethyl carbamate exhibited good linearity with a regression coefficient of 1.000. The limits of detection and quantitation were 0.01 and 0.04 mg/L. The recovery of the method was 100.4 +/- 9.4%. The precision never exceeded 7.8% (intraday) and 10.1% (interday) and the trueness never exceeded 11.3% (intraday) and 12.2% (interday) at any of the concentrations examined, indicating good assay accuracy. A good agreement of analytical results between a previously developed GC/MS SIM method and the GC/MS/MS MRM procedure was found (R=0.987). Regarding the validation data, the procedure is sensitive, selective and reproducible. The applicability of the developed method was demonstrated by the investigation of 70 stone-fruit spirits from commercial trade. The ethyl carbamate concentration of the samples ranged between 0.07 and 7.70 mg/L (mean 1.21 mg/L). The main advantage of the developed GC/MS/MS method is the reliability of the results without the need for time-consuming confirmatory analyses.  相似文献   

2.
Oxidized deoxynucleosides are widely used as biomarkers for DNA oxidation and oxidative stress assessment. Although gas chromatography mass spectrometry is widely used for the measurement of multiple DNA lesions, this approach requires complex sample preparation contributing to possible artifactual oxidation. To address these issues, a high performance liquid chromatography (HPLC)-tandem mass spectrometric (LC-MS/MS) method was developed to measure 8-hydroxy-2'-deoxyguanosine (8-OH-dG), 8-hydroxy-2'-deoxyadenosine (8-OH-dA), 2-hydroxy-2'-deoxyadenosine (2-OH-dA), thymidine glycol (TG), and 5-hydroxy-methyl-2'-deoxyuridine (HMDU) in DNA samples with fast sample preparation. In order to selectively monitor the product ions of these precursors with optimum sensitivity for use during quantitative LC-MS/MS analysis, unique and abundant fragment ions had to be identified during MS/MS with collision-induced dissociation (CID). Positive and negative ion electrospray tandem mass spectra with CID were compared for the analysis of these five oxidized deoxynucleosides. The most abundant fragment ions were usually formed by cleavage of the glycosidic bond in both positive and negative ion modes. However, in the negative ion electrospray tandem mass spectra of 8-OH-dG, 2-OH-dA, and 8-OH-dA, cleavage of two bonds within the sugar ring produced abundant S1 type ions with loss of a neutral molecule weighing 90 u, [M - H - 90]-. The signal-to-noise ratio was similar for negative and positive ion electrospray MS/MS except in the case of thymidine glycol where the signal-to-noise was 100 times greater in negative ionization mode. Therefore, negative ion electrospray tandem mass spectrometry with CID would be preferred to positive ion mode for the analysis of sets of oxidized deoxynucleosides that include thymidine glycol. Investigation of the fragmentation pathways indicated some new general rules for the fragmentation of negatively charged oxidized nucleosides. When purine nucleosides contain a hydroxyl group in the C8 position, an S1 type product ion will dominate the product ions due to a six-membered ring hydrogen transfer process. Finally, a new type of fragment ion formed by elimination of a neutral molecule weighing 48 (CO2H4) from the sugar moiety was observed for all three oxidized purine nucleosides.  相似文献   

3.
Four oxidation products formed during the allomerisation reaction of chlorophyll a in methanol have been separated and identified using normal phase high-performance liquid chromatography (NP-HPLC) coupled with atmospheric pressure chemical ionisation (APCI) tandem mass spectrometry (MS/MS) and photodiode array detection. Fragmentation pathways of the main stereoisomers of the four major products, Mg-purpurin-7 dimethyl phytyl ester, 15(1)-MeO-lact-chl a, 13(2)-MeO-chl a and 13(2)-HO-chl a, have been assigned using APCI-MS(n) aided by examination of deuteriated counterparts of the purpurin and the lactone. Diagnostic fragmentations have been determined, including those for Mg-purpurin-7 dimethyl phytyl ester and 15(1)-MeO-lact-chl a, which display very similar full MS and MS/MS spectra. The use of NP-HPLC offers a rapid and efficient method which, combined with MS/MS, reduces reliance on precursor ion mass for assignment of structure in the allomerisation reaction where major and minor components are often isobaric.  相似文献   

4.
A method for the quantitative enantioselective analysis of amphetamine in human plasma by gas chromatography/negative ion chemical ionization mass spectrometry (GC/NICI-MS) is presented. Five-fold deuterated analogues of both enantiomers were used as internal standard. Plasma sample preparation was performed by a rapid liquid-liquid extraction using n-hexane. Derivatization with (S)-(-)-N-(heptafluorobutyryl)prolyl chloride was accomplished directly in the n-hexane extract to avoid loss of amphetamine during sample concentration. The method was validated in the expected concentration range of 0.006 for a pharmacokinetic study. Calibration curves were linear within a range 0.006-50 ng/mL plasma. Precision and accuracy were acceptable over the entire calibration range. Baseline separation of the enantiomers was easily achieved on a 15-m nonchiral apolar column. The method is simple and robust, and has been applied to the batch analysis of amphetamine enantiomers.  相似文献   

5.
Humic substances were analysed by atmospheric pressure chemical ionisation (APCI) and electrospray ionisation (ESI) mass spectrometry in positive and negative modes. Using APCI the average m/z range of humic substances was reduced 5-fold compared to ESI. High-resolution time-of-flight mass spectrometry revealed the formation of multiply charged molecules in the ESI mode. Moreover, it was possible to obtain daughter ion mass spectra of humic substances by nanospray tandem mass spectrometry. The size-exclusion chromatography elution profile of humic substances was highly influenced by the pH of the analyte solution. By contrast, the pH had no significant influence on the observed mass spectra of humic substances.  相似文献   

6.
A sensitive procedure for the determination of estrogens in urine has been developed, using enzymatic hydrolysis and ether extraction followed by capillary gas chromatography with negative chemical ionisation mass spectrometry (GC/NCI-MS) of the pentafluorobenzoyl derivatives. These derivatives were superior for GC/NCI-MS to trifluoroacetyl, heptafluorobutyl, pentadecafluorooctanoyl and perfluorotolyl derivatives, giving characteristic negative molecular ions as the base peak for each of the naturally occurring estrogens estrone, estradiol and estriol, and for the synthetic estrogen ethynylestradiol used in contraceptive pills. The method was also suitable for determination of some metabolites of estrone and estradiol. The specificity and sensitivity of the GC/NCI-MS method simplifies sample preparation. Recovery of spiked samples was in the range 84-101% for the natural estrogens based on additions to increase the concentration by 5 and 1 microg L(-1). The repeatability of the method was 1-8% for all estrogens.  相似文献   

7.
A sensitive and selective method has been developed for the simultaneous detection in blood of eleven trichothecenes of widely varying polarity. The procedure involved precipitation of blood proteins with acetone followed by a clean-up using reversed-phase Sep-Pak C18 cartridges. The extracted trichothecenes were derivatised as their pentafluoropropionyl esters, separated using capillary gas chromatography and detected using electron-capture negative ion chemical ionisation with methane reagent gas and selected-ion monitoring. Optimum sensitivity and selectivity were obtained using low source temperatures (60 degrees C indicated) and high source pressures (1 Torr indicated). Detection limits on 1-ml blood samples were in the range 0.1-5 ppb. The method was readily adaptable to the detection of other trichothecenes. A protocol was used which minimised the risk of cross-contamination. The method was validated in collaborative studies by the successful analysis of 42 blood samples spiked and submitted blind by two independent laboratories for analysis.  相似文献   

8.
A procedure to analyze ethyl carbamate (EC) by gas chromatography/mass spectrometry was optimized and validated. Deuterated EC (d5-EC) was added to the samples as an internal standard followed by extraction with polystyrene crosslinked polystyrene cartridges using minimal volumes of ethyl acetate. The EC response was measured in selective ion monitoring (SIM) mode and found to be linear in the range between the limit of quantitation (10 micro/L) and 1000 microg/L. EC recoveries varied from 92 to 112%, with the average value of 100 +/- 8%. The procedure compared well (r2 = 0.9970) with the existing AOAC Official Method with the added benefits of minimal solvent usage and reduced matrix interferences.  相似文献   

9.
建立了气相色谱-三重四极杆串联质谱(GC-MS/MS)同时测定调味品中氨基甲酸乙酯(EC)和氯丙醇(3-氯-1,2-丙二醇(3-MCPD)和2-氯-1,3-丙二醇(2-MCPD))的方法。样品添加同位素内标后,采用ExtrelutTM NT有机硅藻土填料进行基质固相分散萃取,先用正己烷淋洗除杂,再用乙酸乙酯-乙醚(20:80, v/v)混合溶剂洗脱被测物,洗脱液经浓缩后采用GC-MS/MS多反应监测(MRM)模式测定。EC、3-MCPD和2-MCPD的方法检出限依次为2、5和5 μg/kg,线性范围依次为5~1000 μg/kg(r=0.9997)、10~1000 μg/kg(r=0.9991)和10~1000 μg/kg(r=0.9995)。酱油、料酒(黄酒)、沙拉酱和方便面调味料4种基体中在20、100和400 μg/kg 3个水平加标测定的平均回收率和相对标准偏差(RSD,n=7)范围分别为EC: 87.7%~104%(RSD为4.3%~10.7%)、3-MCPD: 90.1%~109%(RSD为2.6%~10.2%)、2-MCPD: 90.9%~103%(RSD为3.0%~9.5%)。在部分酱油、料酒和方便面调味料中同时检测到了EC、3-MCPD和2-MCPD,在部分沙拉酱中检测到了EC或3-MCPD。该法准确、快速,适用于调味品中EC、3-MCPD和2-MCPD的同时检测。  相似文献   

10.
A non-aqueous reversed-phase liquid chromatographic method coupled to electrospray ionisation (ESI) tandem mass spectrometry was developed for the analysis of triacylglycerols (TGs). The synthetic TGs studied were separated according to their equivalent carbon number with a gradient of methanol (containing 0.01% (v/v) formate adjusted to pH 5.3 with ammonia) and chloroform. ESI mass spectra of TGs yielded positive ion current signals for [M + NH(4)](+) and [M + NH(4)-RCOONH(4)](+). The mass spectra also showed signals believed to arise from [M + K](+). Collision-induced dissociation (CID) of the [M + NH(4)](+) precursor ion yielded [M + NH(4) - RCOONH(4)](+), [RCO + 74](+) and [RCO](+) product ions as aids for the structural elucidation of the TGs. In addition, [RCO - 18](+) and small amounts of [RCO - 2](+) product ions were also found. The latter ions were observed only for TGs containing unsaturated fatty acids. CID of ammoniated 1-stearoyl-2-oleoyl-3-linoleoyl-glycerol (18:0/18:1/18:2) indicated that neutral loss of the sn-2 fatty acid was energetically less favourable than loss of the fatty acid from the sn-1 or sn-3 position.  相似文献   

11.
The electrospray ionisation ion trap tandem mass spectrometry (ESI-MS(n)) of selected antidepressant drugs, i.e., citalopram, fluoxetine, mirtazapine, paroxetine, sertraline, and venlafaxine, has been investigated. Sequential product ion fragmentation experiments (MS(n)) have been performed in order to elucidate the degradation pathways for the [M+H](+) ions and their predominant product ions. These MS(n) experiments show certain characteristic fragmentations in that functional groups are generally cleaved from the ring systems as molecules such as H(2)O, amines and phenols. When an aromatic entity is present in a drug molecule together with a nitrogen-containing saturated ring structure as with mirtazapine, fragmentation initially occurs at the latter ring with the former being predictably resistant to fragmentation. Also, when an amine-containing drug molecule such as fluoxetine also contains a functional group, which liberates a phenol with a significantly lower DeltaH(f) (0) value than that of the corresponding amine, the phenol is preferentially liberated. The structures of product ions proposed for ESI-MS(n) can be supported by electrospray ionisation quadrupole-time-of-flight tandem mass spectrometry (ESI-QToF-MS/MS). These molecules can be identified and determined in mixtures at low ng/mL concentrations by the application of high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry (HPLC/ESI-MS(2)), which can also be used for their analysis in hair samples.  相似文献   

12.
Summary A highly sensitive and specific gas chromatographic-mass spectrometric (GC-MS) assay for the determination of benzidine in urine is reported. It is based on the solvent extraction of the hydrolysed benzidine conjugates, together with the deuterium-labelled benzidine-d8 added as an internal standard, and a two-phase derivatisation procedure using pentafluoropropionic anhydride (PFPA) in the presence of pyridine as the phase-transfer catalyst. The reaction is complete within 5 min at room temperature. The pentafluoropropyl derivatives are quantified through capillary column GC-MS using selected ion monitoring (SIM) in the negative-ion chemical ionisation mode (NICI). The lower limit of detection for benzidine was 0.5 g/l and the calibration plot showed linearity between 2 g/l and 200 g/l. The recovery of the analyte added to pooled urine was above 82%. Analysis of 20 urine samples from un-exposed persons and 20 urine specimens of workers employed in a polyurethane-making plant using this procedure showed no substances likely to manifest false positive results in the range of interest.  相似文献   

13.
A selective and sensitive method for the simultaneous determination of 14 organophosphate and six phthalate esters using gas chromatography (GC) and mass spectrometry (MS) is presented. Both of these compound classes are frequently found in the indoor environment due to their use as bulk additives in numerous polymers, consumer products and building materials. GC/MS utilizing positive ion chemical ionisation (PICI) in selected reaction monitoring (SRM) mode with isobutane as the reagent gas was found to be the best of the tested methods; it proved superior to electron ionisation (EI) in selected ion monitoring (SIM) mode and to PICI using methane as the reagent gas. The method was applied to indoor air samples collected by active air sampling using solid‐phase extraction (SPE) cartridges. Organophosphates and phthalates were simultaneously determined with method detection limits (MDLs) in the range of 0.1–47 ng m?3. For most compounds the MDLs were ≤0.2 ng m?3, but due to the presence of some of these ubiquitous indoor air pollutants in the blanks, significantly higher MDLs were observed for a few compounds. Finally, the method was also applied in the screening of a much more complex sample matrix, indoor dust. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
The explosive triacetone triperoxide (TATP) has been analyzed by gas chromatography/mass spectrometry (GC/MS) and sub-nanogram detection limits are reported by ammonia positive ion chemical ionization (PICI), electron ionization (EI) and methane negative ion chemical ionization (NICI). Analysis by methane PICI and ammonia NICI gave detection limits in the low nanogram range. Analyses were carried out on (linear) quadrupole and ion trap instruments. Analysis of TATP by PICI using ammonia reagent gas is the preferred analytical method, producing low limits of detection as well as an abundant (greater than 60% of base peak) diagnostic adduct ion at m/z 240 corresponding to [TATP + NH4]+. Isolation of the [TATP + NH4]+ ion with subsequent collision-induced dissociation (CID) produces extremely low abundance product ions at m/z values greater than 60, and the m/z 223 ion corresponding to [TATP + H]+ was not observed. Density functional theory (DFT) calculations at the B88LYP/DVZP level indicate that dissociation of the complex to form NH4+ and TATP occurs at energies lower than peroxide bond dissociation, while protonation of TATP leads to cleavage of the ring structure. These results provide a method for pico-gram detection levels of TATP using commercial instrumentation commonly available in forensic laboratories. As a point of comparison, a detection limit of 15 ng was obtained by flame ionization detection.  相似文献   

15.
A gas chromatography/mass spectrometry (GC/MS) method is described which uses negative ion chemical ionization (NCI) and tandem mass spectrometry (MS/MS) for the determination of eight anabolic steroids in human urine. Eight anabolic steroids were derivatized by heptafluorobutyric anhydride (HFBA), and were determined using GC/NCI-MS and GC/NCI-MS/MS. The linear correlation coefficients for calibration in NCI-MS/MS were in the range 0.9880-0.9988. This method of derivatization with HFBA for use with GC/NCI was useful in determinations of 19-norandrosterone, boldenone, 19-noretiocholanolone, 2-methylandrosterone, nandrolone, 1-methyleneandrosterone, 1-methylandrosterone, 4-dihydroboldenone and mesterolone. The detection limits of this procedure were 5-20 ppb at a signal-to-noise (S/N) ratio of 3.  相似文献   

16.
Zhang Y  Tobias HJ  Brenna JT 《The Analyst》2012,137(13):3102-3110
Comprehensive two dimensional gas chromatography (GC × GC) provides greater separation space than conventional GC. Because of fast peak elution, a time of flight mass spectrometer (TOFMS) is the usual structure-specific detector of choice. The quantitative capabilities of a novel GC × GC fast quadrupole MS were investigated with electron ionization (EI), and CH(4) or NH(3) positive chemical ionization (PCI) for analysis of endogenous urinary steroids targeted in anti-doping tests. Average precisions for steroid quantitative analysis from replicate urine extractions were 6% (RSD) for EI and 8% for PCI-NH(3). The average limits of detection (LODs) calculated by quantification ions for 12 target steroids spiked into steroid-free urine matrix (SFUM) were 2.6 ng mL(-1) for EI, 1.3 ng mL(-1) for PCI-CH(4), and 0.3 ng mL(-1) for PCI-NH(3), all in mass scanning mode. The measured limits of quantification (LOQs) with full mass scan GC × GC-qMS were comparable with the LOQ values measured by one-dimensional GC-MS in selected ion monitoring (SIM) mode. PCI-NH(3) yields fewer fragments and greater (pseudo)molecular ion abundances than EI or PCI-CH(4). These data show that a benchtop GC × GC-qMS system has the sensitivity, specificity, and resolution to analyze urinary steroids at normal urine concentrations, and that PCI-NH(3), not currently available on most GC × GC-TOFMS instruments, is of particular value for generation of structure-specific ions.  相似文献   

17.
The determination of tetra- to octachlorodibenzo-p-dioxins and tetra- to octachlorodibenzofurans (PCCD/Fs) by high-resolution gas chromatography/tandem mass spectrometry (HRGC/MS/MS) and high-resolution gas chromatography/triple mass spectrometry (HRGC/MS(3)) in a quadrupole ion trap, equipped with an external ion source, is presented. MS/MS involves a typical four-step process, namely ionization, parent ion isolation, collision-induced dissociation (CID) and mass analysis of the daughter ions. For the MS(3) experiment, the MS/MS scan function is used with the addition of selected daughter ion isolation, their CID and the mass analysis of second-generation product ions called 'grand-daughter ions.' For both methods, the energies necessary for the CID of the 17 PCDD/Fs were determined and optimized using multiple scan functions with different CID amplitudes. The CID efficiency, defined as the signal ratio of fragment ions detected from the major dissociation channels to molecular ions isolated, was 1.15-2.40 V for parent ion dissociation (MS/MS) and 1.05-1.50 V for daughter ion dissociation (MS(3)) and for all the chloro congeners. The same sensitivity (1 pg microl(-1)) can be reached with both the MS/MS and MS(3) methods and linear responses were obtained between 1 and 100 pg microl(-1) injected.  相似文献   

18.
A highly selective and sensitive gas chromatography-mass spectrometry methodology has been developed for the determination of five antifouling compounds, currently licensed for use in marine antifouling paints. The procedure uses an ion trap mass spectrometer provided with an external ion source that allows the combined use, in the same analysis, of positive (PCI) and negative (NCI) chemical ionisation and tandem mass spectrometric fragmentation (MS-MS). Ionisation and fragmentation processes were optimised individually for each compound, thus, permitting maximum sensitivity and selectivity to be obtained. A complete validation study, including those aspects that affect both correct quantification and unequivocal confirmation, demonstrated the good performance of the proposed method. Detection limits obtained were lower than 0.005 microg l(-1), except for Irgarol 1051 (0.050 microg l(-1)). The method was applied to real seawater samples from different  相似文献   

19.
A novel, sensitive and specific method for the quantification of alpha-tocopherol in two infant foods (milk and cereals) using liquid chromatography on-line with positive atmospheric pressure chemical ionisation mass spectrometry detection (LC/APCI-MS) has been developed. The samples were first saponified in order to eliminate fats and to transform tocopherol esters into free tocopherol, followed up by a liquid-liquid extraction of the analyte in petroleum benzine/diisopropyl ether (75:25, v/v) prior to injection onto the LC system. For the quantification, deuterium-labelled tocopherol was used as internal standard and the samples were monitored in selected ion monitoring (SIM) mode. Calibration curves between 1-40 microg/mL of alpha-tocopherol showed a good linear correlation (r(2) = 0.99994), and the detection limit was determined to be 2.5 ng/mL. The within-day and between-day precision were determined for several dietetic infant formulae and certified reference samples, and found to be below 3.5%. The accuracy determined on a Nestlé reference sample (milk powder) was calculated to be 115.2 +/- 1.2%, which confirms the robustness of the proposed method. This study shows that single quadrupole LC/MS can be applied for the quantification of vitamins in food and the method offers better sensitivity and selectivity than traditional method such as LC-UV. This would simplify the preparation of the food samples and consequently enhance the vitamin analysis throughput in the food area.  相似文献   

20.
Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry (APCI-LC/MS) has been used for identification of the epimers of hydroxy, methoxy and methoxylactone allomers of chlorophyll a (13(2)-HO-chl a, 13(2)-MeO-chl a and 15(1)-MeO-lact-chl a), the hydroxy allomer of bacteriochlorophyll a (13(2)-HO-bchl a) and the hydroxy and methoxylactone allomers of bacterioviridin a (13(2)-HO-bvir a and 15(1)-MeO-lact-bvir a). The APCI mass spectra show that facile fragmentations involve the methoxyl or hydroxyl groups at the C-13(2) or C-15(1) chiral centres. Losses involving the C-13(2) or C-15(1) hydroxyl or methoxyl groups occur more easily from the S-epimer than from the R-epimer due to the greater relief of the steric strain associated with interaction with the bulky C-17 substituent. The differences in mass spectrometric fragmentation can be used as a diagnostic tool for the assignment of the stereochemical configuration at the C-13(2) or C-15(1) chiral centres.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号