首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method to quantitate blood and plasma amino acids by isotope dilution gas chromatography/mass spectrometry (GC/mS) is described. Samples were spiked with U-(13)C amino acids as internal standards and the tert-butyldimethylsilyl derivatives (tBDMS) separated by capillary column gas chromatography. Linear regression curves, generated for individual amino acids, gave correlation coefficients of 0.9999. The reproducibility of the method was assessed from the analysis of 10 replicate blood and plasma samples. For most amino acids a coefficient of variance (CV) of 相似文献   

2.
A rapid analytical method for amines and amino acids was developed, involving derivatization with the novel reagent 3‐aminopyridyl‐N‐hydroxysuccinimidyl carbamate (APDS), followed by reversed‐phase high‐performance liquid chromatography and electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS). More than 100 different analytes with amino groups, including amino acids in biological fluids such as mammalian plasma, could be measured within 10 min. The analytes were easily derivatized with APDS under the mild conditions. Selective reaction monitoring of ESI‐MS/MS in positive mode was carried out to include the transitions of all of the protonated molecular ions of analytes derivatized with APDS to the common fragment at m/z 121, which was derived from the amino pyridyl moiety of the reagent. We evaluated the retention time precision, the quantification limits, the linearity, the intra‐ and inter‐day precisions and the accuracy of 22 typical amino acids found in biological fluids, by analyzing a standard amino acid mixture and rat plasma. The intra‐day relative standard deviations (RSDs) of the retention times of the 22 amino acids and their internal standards were within 0.9% and the inter‐day RSDs were less than 1.1%, except for asparagines, with an RSD of 1.9%. The intra‐day and inter‐day RSDs of amino acid analyses in rat plasma were within 8.0% and 4.5%, respectively. The method, which facilitates the amino acid analysis of more than 100 samples in a day, represents an alternative to traditional amino acid analysis techniques, such as chromatography using postcolumn derivatization by ninhydrin. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
Summary A procedure is described for the screening of disorders of amino acid metabolism or tranpsort. The amino acids and other reactive constituents present in a small volume of deproteinized plasma or urine are derivatized with dansyl chloride. Desalting or concentrating of urine is not required. The fluorescent derivatives are separated by two-dimensional thin-layer chromatography and visualized by ultraviolet radiation. The time of development is less than 1 hr. The derivatives of thirty-seven amino acids and related constituents found in physiological fluids have been mapped in the system. A standard, reflective of normal plasma, is used to aid in identification of those derivatives generally observed on plasma and urine chromatograms and in detection of aminoacidemias. Aminoacidurias are detected by observing derivatives that in relation to others are present in greater than normal amounts.
Analytischer Nachweis von Störungen des Aminosäurestoffwechsels durch Dünnschicht-Chromatographie der Dansylverbindungen
Zusammenfassung Dansylderivate von Aminosäuren und anderen reaktionsfähigen Stoffen in kleinen Volumina enteiweißten Plasmas oder Harns wurden hergestellt. Entsalzung oder Einengung des Harns ist nicht notwendig. Die fluoreszierenden Derivate werden durch zweidimensionale Dünnschichtchromatographie getrennt und im UV nachgewiesen. Die dazu erforderliche Zeit ist kürzer als 1 Stunde. Die Derivate von 37 Aminosäuren und verwandten Verbindungen in physiologischen Flüssigkeiten wurden erfaßt. In üblicherweise zur Beobachtung gelangenden Plasma- bzw. Harnchromatogrammen feststellbare Aminosäuren dienen zum Vergleich mit abnormalen Ergebnissen.
  相似文献   

4.
A complete methodology, incorporating a novel clean-up technique, for quantitative determination of amino acids in plasma by gas chromatography is described. Glucose, a component causing major analytical interference, is removed by an enzymic reaction included in the pre-chromatographic clean-up. The procedure for derivatisation of amino acid standards is shown to be reproducible down to a level of 2.5 micrograms for each amino acid, relative standard deviations for all amino acids except arginine and histidine being 3% or lower. For the entire procedure applied to plasma, relative standard deviations for most amino acids are below 5% with recoveries ranging from 90 to 120%. Normal values, obtained using eighteen plasma samples, are in reasonable agreement with published data. Plasma amino acid values were determined simultaneously by gas chromatographic and ion-exchange chromatographic techniques. Statistical evaluation shows there to be no significant difference between corresponding values for eleven amino acids. Values for tyrosine, histidine and particularly phenylalanine show significant differences (p less than 0.001).  相似文献   

5.
An amino acid analysis by reversed-phase high-performance liquid chromatography after precolumn derivatization with phenyl isothiocyanate was adapted to the determination of free amino acids in plasma or other biological fluids and in tissue homogenates. Preparation of samples included deproteinization by 3% sulphosalicylic acid, and careful removal under high vacuum of residual phenyl isothiocyanate after derivatization. A Waters Pico-Tag column (15 cm long) was used, immersed in a water-bath at 38 degrees C. In rat or human plasma, separation of 23 individual amino acids, plus the unresolved pair tryptophan and ornithine, was obtained within 13 min. Including the time for column washing and re-equilibration, samples could be chromatographed at 23-min intervals. Variability was tested for each amino acid by calculating the coefficients of variation of retention times (less than 1% in the average) and peak areas (less than 4% for both intra-day and inter-day determinations). The linearity for each standard amino acid was remarkable over the concentration range 3-50 nmol/ml. The mean recovery of amino acid standards added to plasma prior to derivatization was 97 +/- 0.8%, except for aspartate (82%) and glutamate (81%). This method is rapid (almost three samples per hour can be analysed, more than in any other reported technique), with satisfactory precision, sensitivity and reproducibility. Therefore, it is well suited for routine analysis of free amino acids in both clinical and research work.  相似文献   

6.
A precolumn derivatization method for the determination of amino acids using 6-aminoquinolyl-N-hyroxy-succinimidyl carbamate (AQC) followed by high-performance liquid chromatography is described. Ultraviolet detection was used for the assay of AQC derivatives of amino acids with the detection wavelength set at 248 nm. The reagent peak interference was minimized by optimizing the pH of the eluent and the gradient elution profile to improve the resolution between the reagent peak and amino acid derivatives. All nineteen amino acids were separated in 35 min with resolutions 1.6. The correlation coefficients of the calibration graphs for seventeen amino acids were fairly good (r 0.9999) at concentrations of 25–500 μM. The detection limits for all common amino acids including cystine and trytophan were at the range of 0.07–0.3 pmol. Good reproducibility and accuracy of the method were demonstrated by the determination of amino acids in three typical kinds of samples (protein, peptide and feed.) The average relative standard deviations for bovine serum albumin (BSA) and neuromedin were 0.86% and 1.36, respectively, and the average relative errors were 3.2% and 2.3%, respectively. The results of the analysis of feed hydrolysates agreed with those obtained by an ion-exchange method and the average recovery of the method for feed hydrolysates was 98%.  相似文献   

7.
The concentrations of free amino acids in plasma and in ascitic liquid of mice with Ehrlich ascitic tumours were determined by reversed-phase high-performance liquid chromatography using pre-column derivatization with Dns chloride and UV detection at 254 nm. Sample preparation is simple, and the Dns derivatives are stable. Complete separation of 27 amino acids, including proline and cysteine, was achieved in 70 min with detection limits of less than 25 pmol. There was no interference from Dns-Cl, Dns-OH and Dns-NH2. Retention time reproducibility was better than 1%. The described method enables a rapid, economical and reproducible quantification of free amino acids in biological fluids.  相似文献   

8.
The use of reversed-phase liquid chromatography (LC) with pre-column derivatization for the analysis of amino acid mixtures is becoming established as a possible cheaper alternative to commercial amino acid analysers. The available derivatization procedures all have disadvantages when applied to clinical samples, partly due to the interferences found with body fluids when ultraviolet or fluorescence detection is used. An LC method is described for the separation of amino acids in blood or urine, using pre-column derivatization with phenylisothiocyanate (PITC), gradient elution and electrochemical detection. The use of electrochemical detection of PITC derivatives virtually eliminates interferences and enables the secondary amino acids to be measured. Examples are shown of normal urine and plasma and samples from patients with cystinuria and maple syrup urine disease.  相似文献   

9.
Separation and detection of seven V-type (venomous) and G-type (German) organophosphorus nerve agent degradation products by gas chromatography with inductively coupled plasma mass spectrometry (GC–ICPMS) is described. The nonvolatile alkyl phosphonic acid degradation products of interest included ethyl methylphosphonic acid (EMPA, VX acid), isopropyl methylphosphonic acid (IMPA, GB acid), ethyl hydrogen dimethylamidophosphate sodium salt (EDPA, GA acid), isobutyl hydrogen methylphosphonate (IBMPA, RVX acid), as well as pinacolyl methylphosphonic acid (PMPA), methylphosphonic acid (MPA), and cyclohexyl methylphosphonic acid (CMPA, GF acid). N-(tert-Butyldimethylsilyl)-N-methyltrifluroacetamide with 1% TBDMSCl was utilized to form the volatile TBDMS derivatives of the nerve agent degradation products for separation by GC. Exact mass confirmation of the formation of six of the TBDMS derivatives was obtained by GC–time of flight mass spectrometry (TOF-MS). The method developed here allowed for the separation and detection of all seven TBDMS derivatives as well as phosphate in less than ten minutes. Detection limits for the developed method were less than 5 pg with retention times and peak area precisions of less than 0.01 and 6%, respectively. This method was successfully applied to river water and soil matrices. To date this is the first work describing the analysis of chemical warfare agent (CWA) degradation products by GC–ICPMS. Figure Illustrated here are six parent organophosphorus nerve agents corresponding to the degradation products analyzed by gas chromatography with ICPMS and ToF-MS detection. The authors would like to thank Daisy-Malloy Hamburg and Kevin M. Kubachka for creating this figure  相似文献   

10.
A capillary chromatographic procedure using a fused silica column is described which can be used to quantitatively determine amino acids in plasma following the pre-chromatographic “clean-up” described in a recent paper [1]. In substituting this procedure for that involving a packed column, advantage has been taken of the greater resolving power to separate amino acids from background component peaks. In order to extend this advantage and provide a sound basis for quantitative analysis, the technique of cold on-column injection was employed. As a result, good precision of standard analysis was obtained with relative standard deviation (RSD) values for all amino acids of less than 4%. Application of the entire procedure to plasma samples yields RSD values of better than 10% for all amino acids with recoveries ranging from 72% to 104%. Simultaneous determination of plasma amino acid levels by gas chromatography (GC) using capillary columns and by classical ion exchange (CIE) showed reasonable agreement. Statistical evaluation showed no significant difference between twelve amino acids. Values for the remaining two, namely, phenylalanine and histidine are significantly different (p < 0.005). Comparison of the values obtained from GC capillary and packed columns reveals no significant difference between fourteen amino acids. Significant differences exist between results for phenylalanine and tyrosine (p < 0.001). It is concluded that there is good agreement between data obtained by GC capillary and CIE techniques and that differences between results for phenylalanine and histidine are method related.  相似文献   

11.
Erythrocyte amino acid levels were determined, by gas chromatography, in a group of 34 normal human adults. No significant sex or age correlations were noted. A method for the quantitative gas chromatographic analysis of free amino acids in erythrocytes is described. Following hemolysis and deproteinization the amino acids were isolated on a cation-exchange resin. Glutathione was removed from the amino acid mixture by adsorption on an anion-exchange resin. Following conversion to their N-acetyl-n-propyl esters, 19 amino acids were separated and quantitated by gas chromatography on a single column in 18 min. Typical reproducibility data indicate that a coefficient of variation of 2-5% is attainable.  相似文献   

12.
A validated, selective and sensitive pre-column derivatization chromatographic method for determination of some aminoglycoside antibiotics, namely, amikacin (AMK), gentamicin and neomycin sulphates, has been developed. Determination was obtained by pre-column reaction of the samples with 7-fluoro-4-nitrobenz-2-oxa-1,3-diazole and separating the corresponding derivatives on a reversed phase LC column (ultrasphere C18, 250 × 4.6 mm) and fluorescence detection (λ ex 465 nm, λ em 531 nm). Linear quantitative response curve was generated over a concentration range of 0.05–10 μg mL?1 with a correlation coefficient of more than 0.999 with all studied compounds. The accuracy and precisions were satisfactory for determination of all drugs in dosage forms within- and between-run assay. Furthermore, the method was extended to the determination of AMK in spiked human plasma. The method is specific for the intact drugs, and can be adopted in the presence of co-formulated drugs.  相似文献   

13.
The dinitrophenyl (DNP) derivatives of amino acids have found continual application in protein sequencing since Sanger used them for the first time for the sequencing of insulin. Dansyl derivatives of amino acids have been widely used in protein sequencing because of their fluorescent nature. The success of protein sequencing largely depends upon correct identification of such derivatives. The choice for the method of identification is related to cost, the availability of instrumentation and to the sensitivity needed for the analysis. Thin layer chromatography (TLC) is simple and has several advantages over other chromatographic methods. Therefore the literature after 1972 is reviewed for TLC analysis of dansyl- and DNP-amino acids, the two important amino acid derivatives required for identifying protein sequences. Additionally, the literature on the TLC resolution of enantiomeric mixtures of dansyl amino acids is reviewed. Application of various adsorbents, composition of solvent systems and other experimental conditions together with successful resolution data have been discussed. TLC provides a direct and inexpensive method for the resolution of enantiomers, and is fast becoming a sensitive instrumentalized quantitative analytical technique.  相似文献   

14.
Capillary gas chromatography of amino acid derivatives obtained from biological material shows a large number of previously unknown constituents. The profiles of amino acids obtained from urine of healthy individuals and haemofiltrate of uraemic patients indicate that haemofiltration removes some amino acids to a considerably higher extent from uraemic patients than the kidney does from healthy persons. For instance, if haemofiltration is required three times a week, an approximately ten-fold amount of the essential amino acid methionine and a forty-fold amount of the essential amino acid leucine is lost compared to their excretion in urine by a healthy individual over the same period.  相似文献   

15.
The gas chromatographic determination of amino acids via their simultaneous extraction, preconcentration and pentafluorobenzylation is reported. Using phase-transfer catalysis (PTC), the amino acids under study were transformed to their pentafluorobenzyl adducts. The method was tested for different catalysts and tetrabutylammonium bromide provided favorable features in comparison to the other PTCs. The derivatization procedure was optimized and the best reaction conditions are given. With the exception of arginine, 19 amino acids were converted to volatile derivatives and analyzed with GC/MS and GC/FID at low concentration levels with acceptable sensitivity and good reproducibility. The LODs were found to range from 0.7 to 2.3microM for the GC/MS analyses and from 1.7 to 6.9microM for GC/FID analyses. The method practicability and applicability were confirmed by the analysis of urine, fruit juice and wheat flour for the determination of the amino acids under study. Protein-bound amino acids were analyzed after an alkaline hydrolysis step with 5M NaOH applying this method to wheat flour with an overall procedure duration less than 12h. The optimized protocol was applied to these samples without any pretreatment and their amino acid concentrations were calculated from the appropriate calibration plots.  相似文献   

16.
A new approach for the analysis of large-volume naphthalene-2,3-dicarboxaldehyde (NDA) derivatives of amino acids by micellar electrokinetic chromatography (MEKC) in conjunction with a purple light-emitting diode-induced fluorescence detection is described. In order to optimize resolution, speed, and stacking efficiency, a discontinuous condition is essential for the analysis of NDA-amino acid derivatives. The optimum conditions use 2.0M TB (pH 10.0) buffer containing 40mM sodium dodecyl sulfate (SDS) to fill the capillary, deionized water to dilute samples, and 200mM TB (pH 9.0) containing 10mM SDS to prepare 0.6% poly(ethylene oxide) (PEO). Once high voltage is applied, PEO solution enters the capillary via electroosmotic flow and SDS micelles interact and thus sweep the NDA-amino acid derivatives having smaller electrophoretic mobilities than that of SDS micelles in the sample zone. When the aggregates between SDS micelles and NDA amino acid derivatives enter PEO zone, they are stacked due to decrease in electric field and increases in viscosity. Under the optimum conditions, the concentration and separation of 0.53-microL 13 NDA-amino acid derivatives that are negatively charged has been demonstrated by using a 60-cm capillary, with the efficiencies 0.3-9.0x10(5) theoretical plates and the LODs at signal-to-noise ratio 3 ranging from 0.30 to 2.76nM. When compared to standard injection (30-cm height for 10s), the approach allows the sensitivity enhancements over the range of 50-800 folds for the derivatives. The new approach has been applied to the analysis of a red wine sample, with great linearity of fluorescent intensity against concentrations (R(2)>0.98) and the RSD (three repetitive runs in one day) values of the migration times for the ten identified amino acids less than 2.8%.  相似文献   

17.

A validated, selective and sensitive pre-column derivatization chromatographic method for determination of some aminoglycoside antibiotics, namely, amikacin (AMK), gentamicin and neomycin sulphates, has been developed. Determination was obtained by pre-column reaction of the samples with 7-fluoro-4-nitrobenz-2-oxa-1,3-diazole and separating the corresponding derivatives on a reversed phase LC column (ultrasphere C18, 250 × 4.6 mm) and fluorescence detection (λ ex 465 nm, λ em 531 nm). Linear quantitative response curve was generated over a concentration range of 0.05–10 μg mL−1 with a correlation coefficient of more than 0.999 with all studied compounds. The accuracy and precisions were satisfactory for determination of all drugs in dosage forms within- and between-run assay. Furthermore, the method was extended to the determination of AMK in spiked human plasma. The method is specific for the intact drugs, and can be adopted in the presence of co-formulated drugs.

  相似文献   

18.
A simple, sensitive and reproducible isocratic high-performance liquid chromatography (HPLC) method has been developed for the determination of amino acids in human serum. The method involves precipitation of the serum proteins with methanol followed by pre-column derivatization of amino acids with o-phthalaldehyde-2-mercaptoethanol or o-phthalaldehyde-sodium sulfite. HPLC separation of the derivatives was performed using an ODS column with an isocratic mobile phase system and electrochemical detection (+0.75 V). The response was linear over the range 5-300 microM for all amino acids. The method allows quantitative determination of glutamic acid, asparagine, serine, glutamine, histidine, taurine, alanine, arginine, methionine, isoleucine, ornithine, leucine, phenylalanine, lysine and tryptophan at concentrations as low as 0.5-5.0 pmol (signal-to-noise ratio=2). Using this method, the levels of amino acids in serum from healthy donors and patients with ischemic stroke were determined.  相似文献   

19.
In this study, a fast and quantitative determination method for branched-chain amino acids (BCAAs), namely leucine, isoleucine, and valine, was developed using a pillar array column. A pillar array column with low-dispersion turns was fabricated on a 20?×?20-mm2 microchip using multistep ultraviolet photolithography and deep reactive ion etching. The BCAAs were fluorescently labeled with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F), followed by reversed-phase separation on the pillar array column. The NBD derivatives of the three BCAAs and an internal standard (6-aminocaproic acid) were separated in 100 s. The calibration curves for the NBD-BCAAs had good linearity in the range of 0.4–20 μM, using an internal standard. The intra- and interday precisions were found to be in the ranges of 1.42–3.80 and 2.74–6.97 %, respectively. The accuracies for the NBD-BCAA were from 90.2 to 99.1 %. The method was used for the analysis of sports drink and human plasma samples. The concentrations of BCAAs determined by the developed method showed good agreements with those determined using a conventional high-performance liquid chromatography system. As BCAAs are important biomarkers of some diseases, these results showed that the developed method could be a potential diagnostic tool in clinical research.  相似文献   

20.
A sensitive, reproducible, and rapid method was developed for the simultaneous determination of underivatized amino acids (aspartate, serine, glycine, alanine, methionine, leucine, tyrosine, and tryptophan) and neurotransmitters (glutamate and γ‐aminobutyric acid) in plasma samples using hydrophilic interaction liquid chromatography coupled to triple quadrupole tandem mass spectrometry. The plasma concentrations of amino acids and neurotransmitters obtained from 35 schizophrenic patients in treatment with clozapine (27 patients) and olanzapine (eight patients) were compared with those obtained from 38 healthy volunteers to monitor the effectiveness of treatment. The chromatographic conditions separated ten target compounds within 3 min. This method presented linear ranges that varied from (lower limit of quantification: 9.7–13.3 nmol/mL) to (upper limit of quantification: 19.4–800 nmol/mL), intra‐ and interassay precision with coefficients of variation lower than 10%, and relative standard error values of the accuracy ranged from –2.1 to 9.9%. The proposed method appropriately determines amino acids and neurotransmitters in plasma from schizophrenic patients. Compared with the control group (healthy volunteers), the plasma levels of methionine in schizophrenic patients treated with olanzapine are statistically significantly higher. Moreover, schizophrenic patients treated with clozapine tend to have increased plasma levels of glutamate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号