首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A capillary isotachophoretic (cITP) method to determine the concentration of 3-methylhistidine (3-MeHis) in meat and meat products is described. A clear separation of the 3-MeHis from histidine, 1-methylhistidine and other components of acidic sample hydrolyzate was achieved within 20 min. Method characteristics (linearity, accuracy, precision and detection limit) were determined. Low laboriousness, sufficient sensitivity and low running cost are the important attributes of cITP method. The developed method was successfully applied to analyses of real samples and used for the determination of lean meat content in meat and meat products.  相似文献   

2.
3.
We describe a new CE method with UV-detection for the quantification of histidine (His) and its methylated forms 1-methylhistidine and 3-methylhistidine, both in plasma and urine. Analytes were basically resolved using a 60?mmol/L Tris-phosphate run buffer pH 2.2 in less than 12?min. The use of a mixture of ACN/ammonia (80:20) for protein precipitation allows the quantitative recovery of all His from plasma. The optimization of the sample volume injection permits to reach an LOD of 20?nmol/L, thus improving the sensitivity of about hundred times in comparison to the previous described assays. Moreover, the opportunity to also measure creatinine in the same run makes it possible to evaluate the renal function contemporarily, thus avoiding further dosages with significant time saving. The application method has been proved by measuring His, 1-methylhistidine and 3-methylhistidine in 44 healthy subjects. In conclusion, our new method seems to be an inexpensive, fast and specific tool to assess large numbers of patients for routine analysis both in clinical and research laboratories.  相似文献   

4.
5.
A reversed-phase high-performance liquid chromatography assay for mangiferin in rat plasma and urine was developed. Rutin was employed as an internal standard. The mobile phase consisted of acetonitrile-water (16:84, v/v) containing 3% acetic acid at a flow rate of 1 mL/min. Detection was at 257 and 365 nm for mangiferin in plasma and urine, respectively. The limit of quantitation (LOQ) of mangiferin was 0.6 microg/mL in plasma, and 0.48 microg/mL in urine. The standard curve was linear from 0.6 to 24 microg/mL in plasma, and 0.48 to 24 microg/mL in urine, both intra- and inter-day precision of the mangiferin were determined and their RSD did not exceed 10%. The method provides a technique for rapid analysis of mangiferin in rat plasma and urine, which can be used in pharmacokinetic studies.  相似文献   

6.
7.
8.
A reversed-phase high-performance liquid chromatographic method is described for the determination of 3-methylhistidine content in human urine using pre-column derivatization with phenylisothiocyanate, isocratic elution with 15 mM sodium acetate-acetonitrile (92:8, v/v) and electrochemical detection. The limit of quantitation was 0.1 pmol. The method has been applied in routine analyses of 3-methylhistidine in both clinical and research work.  相似文献   

9.
10.
A rapid and sensitive method for determination of methamphetamine and amphetamine in urine was developed by using electron-capture gas chromatography. The extraction procedure, the experimental conditions for pentafluorobenzoyl derivative formation and the percentage recovery of the drugs from urine are described. The pentafluorobenzoyl derivative of methamphetamine showed a higher electron-capture sensitivity and was detected in at least 23-fold lower concentration than the heptafluorobutyryl derivative which is commonly used as a derivatizing agent for the amine. The detection limit of pentafluorobenzoyl derivatives of methamphetamine and amphetamine was ca. 10 pg. A concentration as low as 10 ng/ml of methamphetamine and amphetamine in urine was easily detected by this method.  相似文献   

11.
12.
A sensitive and specific high performance liquid chromatographic method is described for measuring imidazole dipeptides and 3-methylhistidine in human muscle biopsies, serum and urine. Muscle extract, serum or urine was reacted with o-phthaldialdehyde and the derivatives were separated by reversed phase chromatography with column switching and fluorescence detection.  相似文献   

13.
A rapid method has been devised for the direct determination of chlormequat in tomato samples. No clean-up is required, and analysis uses ion-exchange liquid chromatography/tandem mass spectrometry interfaced with electrospray ionization (LC/ESI-MS/MS). A cation-exchange column was used with an aqueous ammonium acetate/acetonitrile mixture as the mobile phase under isocratic conditions. The method was validated in terms of detection limits (LOD), quantitation limits (LOQ), linearity, recovery, precision and accuracy. Good results in the low micro g kg(-1) level were obtained for the LOD and LOQ of chlormequat in tomato samples. Comparison of solvent and matrix-matched calibration curves demonstrated the absence of significant matrix effects and the feasibility of using external calibration. Linearity was established over two orders of magnitude by performing homoscedasticity and Mandel fitting statistical tests. The absence of both constant and proportional systematic errors was verified by evaluating the recovery function, demonstrating good method accuracy. Excellent precision in terms of intra-day repeatability was calculated (RSD% <3.4). Extraction recoveries from tomato products were calculated, by using a labelled internal standard (d(4)-chlormequat), to be in the 93 +/- 5-99 +/- 7% range. The applicability of the method to the determination of chlormequat residues in tomato products was demonstrated.  相似文献   

14.
A simple and rapid sample preparation method for the determination of chloramphenicol in swine muscle tissue at the 10 micrograms/kg level is described. The method comprises sonication-aided extraction with ethyl acetate, addition of hexane to the extract and cleaning up and concentration of the extract on a small column packed with silica gel. Analysis was performed by high-performance liquid chromatography on a ChromSep column with ChromSpher C8 using acetonitrile-sodium acetate buffer as the mobile phase. Detection was performed at 280 nm. Mean recoveries from spiked muscle samples were 79 +/- 3% (10-50 micrograms/kg). The distribution of chloramphenicol in different muscle and fatty tissues from a pig to which a single dose of chloramphenicol was administered was also investigated.  相似文献   

15.
An analytical procedure was developed for the determination of tritium in urine. The content of contaminants in urine after treatment is reduced markedly so that no influence is expected on tritium measurements by a liquid scintillation counter. The established analytical procedure was successfully applied for urine from the general public in Japan.  相似文献   

16.
17.
A rapid method for the determination of mercury in urine   总被引:4,自引:0,他引:4  
G Lindstedt 《The Analyst》1970,95(128):264-271
  相似文献   

18.
Bovine muscle carbonic anhydrase III was purified to homogeneity by the strategy of rapid ion-exchange chromatography. The ionic exchanger used was CM-cellulose, and this is the first application of this technique on a cation exchanger. Nitrogen gas was used to pressurize the chromatographic column to accelerate the elution. The results show that proteins with high isoelectric points can also be purified in this way. The procedure is very time-saving compared with conventional chromatography, reducing the elution time five- to ten-fold. The proteins are in addition protected against oxidation by air.  相似文献   

19.
A rapid procedure has been developed for the determination of total fluoride in liquids. The samples are burned in a modified BECKMAN oxy-hydrogen burner The fluoride is scrubbed out of the products of combustion and determined in any conventional manner  相似文献   

20.
A radiochemical procedure comprising ion chromatography for preconcentration, oxalate precipitation for alkali/alkaline earth separation, strontium specific extraction chromatography with a crown ether for calcium/strontium separation, carbonate precipitation for counting on a low background proportional counter, provides a simple, rapid (48 h) and effective method for radiostrontium determination in emergency situation in milk. The separation scheme gives a strontium recovery rate of 62% and an empiric relative standard deviation of 11%. The detection limit for 500 ml milk and 3600-second counting time is 0.090 Bq.l-1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号