首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
Customary 13CO2 breath tests--and also 15N urine tests--always start with an oral administration of a test substrate. The test person swallows a stable isotope labelled diagnostic agent. This technique has been used to study several pathophysiological changes in gastrointestinal organs. However, to study pathophysiological changes of the bronchial and lung epithelium, the inhalative administration of a stable isotope labelled agent appeared more suitable to us. [1-13C]Hexadecanol and [1-13C]glucose were chosen. Inhaled [1-13C]hexadecanol did not yield 13CO2 in the exhaled air, but [1-13C]glucose did. To study the practicability of the [1-13C]glucose method and the reproducibility of the results, 18 inhalation tests were performed with healthy subjects. In 6 self-tests, the optimum inhalative dose of [13C]glucose was determined to be 205 mg. Using the APS aerosol provocation system with the nebulizer 'Medic Aid' (Erich Jaeger Würzburg), a 25% aqueous solution was inhaled. Then, breath samples were collected at 15 min. intervals and analysed for 13CO2. 75-120 min after the end of inhalation a well-reproducible maximum delta13C value of 6%o over baseline (DOB) was detected for 12 healthy probands. Speculating that the pulmonary resorption of the [13C]glucose is the rate-limiting step of elimination, decompensations in the epithelium ought to be reflected in changed [1-13C]glucose resorption rates and changed 13CO2 output. Therefore, we speculate that the inhalation of suitable 13C-labelled substrates will pave the way for a new group of 13CO2 breath tests aiding investigations of specific pathophysiological changes in the pulmonary tract, such as inflammations of certain sections and decompensations of cell functions.  相似文献   

2.
In this study, we performed three breath tests – l-[1-13C ]phenylalanine breath test (PBT), l-[1-13C ] methionine breath test, and [13C]methacetin breath test (MethaBT) – in patients with chronic liver disease to determine the optimal timing of expired air collection for diagnosing chronic liver disease and evaluating the grade of fibrosis. The subjects were 61 adults with normal livers, 98 chronic hepatitis patients, and 91 liver cirrhosis patients. We investigated the relationships of breath test results with routine biochemical tests and the Child–Pugh score, as well as the diagnostic capacities of the breath tests for liver dysfunction/cirrhosis and grade of liver fibrosis. For the diagnosis of liver cirrhosis and correlations with liver fibrosis, the accuracy of the PBT at 30 min (PBT30) was similar to that of the MethaBT at 15 min (Metha15). For liver function assessment by two-point measurement with 13C breath tests, we recommend the PBT30 and the Metha15.  相似文献   

3.
A newly developed isotope selective nondispersive infrared (NDIR) spectrometer for the measurement of 13CO2 and 12CO2 concentrations in breath samples was applied as a low cost and very simple to operate alternative to isotope ratio mass spectrometry (IRMS). We used this device for several biomedical applications ([13C]urea breath test, [13C]leucine metabolism, [13C]methacetin catabolism of rats) and found that the results agree very well with IRMS.  相似文献   

4.
Abstract

The [13C]aminopyrine breath test ([13C]ABT) measures the global activity of cytochrome P450 in vivo and is a sensitive indicator of liver metabolic dysfunction. The present study aims to determine whether gender and cigarette smoking influence the results of [13C]ABT as well as to confirm the effect of oral contraceptive steroids (OCS) intake on this metabolic test. Hundred and ten healthy subjects, including men and women, smoker and non-smoker, women taking OCS or not, were phenotyped for CYP1A2 using the [13C]caffeine breath test and underwent a [13C]ABT. Both tests showed large inter-individual variations in accordance with that of CYP450 liver content. [13C]ABT was sensitive enough to point out a significant induction or inhibition related to cigarette smoking habits or OCS. The combined effect of smoking and OCS resulted in an overall unchanged metabolic activity. Consequently, the impact of the studied conditions on the [13C]ABT parameters must be considered by clinicians or clinical investigators.  相似文献   

5.
[5-13C,15N]Glutamine, with 1J(13C–15N) of 16 Hz, was observed in vivo in the brain of spontaneously breathing rats by 13C MRS at 4.7 T. The brain [5-13C]glutamine peak consisted of the doublet from [5-13C,15N]glutamine and the center [5-13C,14N]glutamine peak, resulting in an apparent triplet with a separation of 8 Hz. The time course of formation of brain [5-13C,15N]glutamine was monitored in vivo with a time resolution of 20–35 min. This [5-13C,15N]glutamine was formed by glial uptake of released neurotransmitter [5-13C]glutamate and its reaction with 15NH3 catalyzed by the glia-specific glutamine synthetase. The neurotransmitter glutamate C5 was selectively13C-enriched by intravenous [2,5-13C]glucose infusion to 13C-label whole-brain glutamate C5, followed by [12C]glucose infusion to chase 13C from the small and rapidly turning-over glial glutamate pool, leaving 13C mainly in the neurotransmitter [5-13C]glutamate pool, which is sequestered in vesicles until release. Hence, the observed [5-13C,15N]glutamine arises from a coupling between 13C of neuronal origin and 15N of glial origin. Measurement of the rate of brain [5-13C,15N]glutamine formation provides a novel noninvasive method of studying the kinetics of neurotransmitter uptake into glia in vivo, a process that is crucial for protecting the brain from glutamate excitotoxicity.  相似文献   

6.
The [13C]methacetin breath test ([13C]MBT) – a valuable non-invasive tool dedicated to the assessment of the liver metabolic capacity – still needs standardisation. The aim of this study was to check whether currently used dosage regimens of [13C]methacetin provide concordant [13C]MBT results in subjects with an atypical body constitution. Healthy volunteers: low body mass<55 kg (eight women), and high body mass>95 kg (eight large body frame men) were recruited. They underwent [13C]MBT on separate days, taking in random order [13C]methacetin: a fixed 75 mg dose (FX75), or a 1 mg kg?1 body mass-adjusted dose (BMAD). Samples of expiratory air for 13CO2 measurement were collected over 3 h. The maximum momentary 13C elimination in breath air occurred earlier and was higher following BMAD than with FX75 in the low body mass females (T max 14.6±1.0 min vs. 22.1±2.4 min, p=0.019; D max 41.9±2.9 % dose h?1 vs. 36.6±3.6 % dose h?1, p=0.071). In the high body mass men, T max remained unchanged, whereas D max was slightly higher with BMAD compared to FX75 (21.5±3.2 min vs. 23.0±3.0 min; 38.5±2.9 % dose h?1 vs. 32.3±2.5 % dose h?1). It is concluded that in subjects with a body constitution outside the general population average, the dosage of the substrate may affect some results of the [13C]MBT. The dosage-related differences appear, however, to be insignificant if the result of the [13C]MBT is reported as a cumulative 13C recovery in breath air.  相似文献   

7.
Abstract

This paper was presented in poster form at the 17th International Congress of Nutrition, August 27-31, Vienna. Austria (Annals of Nutrition & Metabolism 2001; 45(Suppl.1):349). Some of the data were also presented in poster form at the British Society of Gastroenterology Meeting, March 18-21, Glasgow, UK (Gut 2001; 48(Suppl.1):A91).

The 13C-mixed triacylglycerol (MTG) breath test is used to measure intraluminal fat digestion. In normal digestion. 20–40% of the ingested 13C label is recovered in breath CO2. We aimed to identify the proportions of ingested label excreted in stool, as well as breath following ingestion of 13C-MTG by children with impaired exocrine pancreatic function and healthy controls. 13C enrichment of breath samples was measured by continuous flow isotope ratio mass spectrometry (IRMS) and cumulative percent dose recovered (cPDR) in 10 h was calculated. Total 13C of a faecal fat extract from each stool was measured by elemental analyser-IRMS, and 13C enrichment and concentration of the TBDMS derivative of octanoic acid was measured by GC/MS after hydrolysis of the fat extract. Stool 5-day cPDR was calculated. Mean breath cPDR was 35%. Mean cPDR in stool by combustion-IRMS and GC/ MS, respectively, was 0.8% and 1.0%. Therefore, the remaining 64% of the 13C label must remain in the body and variability in breath cPDR is due to postabsorptive rather than predigestive factors.  相似文献   

8.
The aim of this study was to investigate the hepatic microsomal and mitochondrial functions by using the 13CO2-breath test in healthy subjects either before or after the consumption of red wine. Fourteen adults received [13C]methacetin and [methyl-13C]methionine together with a standardised dinner. Expired air samples were taken over 6 h. After a wash-out period, the subjects consumed 0.4 ml ethanol/kg/day together with dinner over a 10-day period. Thereafter, 13C-tracer administration was repeated under identical conditions. The 13CO2-enrichments were measured by isotope ratio mass spectrometry. The mean cumulative percentage 13C-dose recovery (CPDR) after administration of [13C]methacetin and [methyl-13C]methionine either without or with red wine consumption amounted to 38.2±6.3 vs. 36.3±6.7% (p=0.363) and 9.5±3.3 vs. 8.8±2.5% (p=0.47), respectively. Moderate alcohol consumption does not induce significant short-term changes of the microsomal and the mitochondrial functions of the human liver in healthy subjects.  相似文献   

9.
The aim of this study is to determine if age is a factor influencing the results of a [13C]methacetin breath test (13C-MBT). Two groups of healthy volunteers, each comprising six men and six women, but differing in average age (Y=young, 25.1±0.6 years, MA=middle-aged;, 46.0±2.1 years) orally took 75 mg [13C]methacetin. Samples of expiratory air for 13CO2 measurement were collected up to 48 h after intake of the substrate. A maximum momentary 13CO2 breath exhalation of 37.0±2.6%dose/h was observed at 18 min (median, range: 9–30 min) in the young subjects and of 38.4±2.5%dose/h at 18 min (median, range: 12–30 min) in the middle-age volunteers. The cumulative 13C elimination in expiratory air was statistically significantly higher in the MA compared with the Y group as from 75 min up to 180 min, indicating a greater microsomal metabolic efficiency of the liver in the middle-aged healthy subjects. Gender, use of hormonal contraception, cigarette smoking, or body mass index did not modify the age-related effect on the cumulative 13C elimination in breath air. The study results imply a necessity of composing control groups well matched with regard to the age structure for a proper interpretation of clinical 13C-MBT results.  相似文献   

10.
In this work the feasibility of measuring neuronal-glial metabolism in rat brain in vivo using co-infusion of [1,6-13C2]glucose and [1,2-13C2]acetate was investigated. Time courses of 13C spectra were measured in vivo while infusing both 13C-labeled substrates simultaneously. Individual 13C isotopomers (singlets and multiplets observed in 13C spectra) were quantified automatically using LCModel. The distinct 13C spectral pattern observed in glutamate and glutamine directly reflected the fact that glucose was metabolized primarily in the neuronal compartment and acetate in the glial compartment. Time courses of concentration of singly and multiply-labeled isotopomers of glutamate and glutamine were obtained with a temporal resolution of 11 min. Although dynamic metabolic modeling of these 13C isotopomer data will require further work and is not reported here, we expect that these new data will allow more precise determination of metabolic rates as is currently possible when using either glucose or acetate as the sole 13C-labeled substrate.  相似文献   

11.
Abstract

A seven compartment model was applied for evaluation of oral L-[1-13C]leucine loading tests (38 μmol/kg body wt.) in healthy volunteers. The model comprises transport and absorption in stomach and gut into a central L-leucine-compartment which is connected to a protein compartment and to the compartment of the corresponding 2-oxo acid. CO2 release from the latter occurs in a fast and a slow compartment into the central CO2 compartment for exhalation. Using the fmins routine of MATLAB for parameter estimation, a good agreement was obtained between calculated and actually measured kinetics of 13C-labelled metabolites and a mean in vivo L-leucine oxidation of 0.365 ± 0.071 μmol/kg per min (n = 5) was computed. Plausibility of the model was checked by predicting in vivo leucine oxidation rates from primed continuous infusion tests (priming: L-[1-13C]leucine, 5 μmol/kg; NaH13CO2, 1.2 μmol/kg; infusion: L-[1-13C]leucine, 5 μmol/kg per h). In 5 tested volunteers, the experimental L-leucine oxidation rate amounted to 0.358 ± 0.105 μmol/kg per min versus predicted 0.324±0.099 μmol/kg per min. Possible causes for some observed intraindividual variations are discussed.  相似文献   

12.
We evaluated the reproducibility of the 13C-phenylalanine breath test (13C-PheBT). On three separate days, 21 healthy volunteers (11 F and 10 M) underwent 13C-PheBT with 100 mg l-[1-13C]phenylalanine taken orally. Short-term reproducibility was evaluated with paired examinations taken 3 days apart; paired examinations separated by 23 days (median) served for the medium-term reproducibility assessment. Expiratory air was sampled at 19 points throughout 3?h. Determined limited reproducibility of the 13C-PheBT must be taken into consideration while interpreting the results of this diagnostic tool. The results of this study imply the following conclusions: (i) From among the three parameters examined, the cumulative 13C recovery area under the curve (AUC) offers much better reproducibility than the maximum momentary 13C recovery in the expiratory air (Dmax) or the time to reach the maximum momentary 13C recovery (Tmax) (ii) Collection of the breath air samples for 2?h results in a much better reproducibility of AUC, than for 1?h only; (iii) Reproducibility of 13C-PheBT is affected neither by the duration of the time gap between repeated tests nor by gender; (iv) Comparison with data obtained formerly reveals that reproducibility of the 13C-PheBT is worse than either that of of the 13C-methacetin (13C-MBT) or the 13C-alpha-ketoisocaproic acic (13C-KICA-BT) breath tests. This finding will have to be taken into consideration while interpreting the results of this diagnostic tool.  相似文献   

13.
Abstract

Breath tests using 13C-labelled substrates require the measurement of 13CO2/12CO2 ratio in breath gas samples. Next to isotope ratio mass spectrometry (IRMS), which is very sensitive but also complex and expensive, alternatively isotope selective nondispersive infrared spectrometry (NDIRS) can be used to determine the 13CO2/12CO2 ratio in expired breath. In this study we compared NDIRS- with IRMS-results to investigate whether the less expensive and very simply to operate NDIRS works as reliable as IRMS. For this purpose we applicated 1-13C-Phenylalanine to patients with advanced liver cirrhosis and healthy volunteers and took duplicated breath samples for IRMS and NDIRS at selected time points. Our data show a good correlation between these two methods for a small number of samples as required for simple breath tests. Longer series, where repeated measurements are required on the NDIRS instrument lead to a decreasing correlation. This indicates the superiority of IRMS concerning 13CO2-kinetics over longer time periods.  相似文献   

14.
Abstract

Two novel characteristic parameters, the latency time (t lat) and the ascension time (t asc), are proposed for evaluation of non-invasive [13C]octanoic acid breath tests for assessment of the gastric emptying of solids. In breath tests performed in control subjects (n = 30) and diabetic patients (n = 100), the usefulness of these parameters was compared to conventional parameters, i.e., gastric half emptying-time t 1/2,b ) and lag phase (t lag,b ). The proposed parameters were only loosely correlated (controls, r = 0.199; diabetics, 0.616). A strong correlation was found between the conventional parameters (controls, r = 0.891; diabetics, r = 0.962). Based on the conventional method, 36 patients were suspicious of delayed gastric emptying including 24 patients which exhibited a simultaneous delay in both parameters. Using the new parameters, a total of 46 patients were suspicious of delayed gastric emptying with 15 and 20 having isolated delay in t lat and t asc, respectively. We conclude that the novel parameters may be more appropriate for examination of the different phases of gastric emptying and for evaluation of gastric emptying disturbances in diabetic patients than the parameters conventionally used for this purpose.  相似文献   

15.
[1-13C] pyruvate pre-polarized via DNP has been used in animal models to probe changes in metabolic enzyme activities in vivo. To more accurately assess the metabolic state and its change from disease progression or therapy in a specific region or tissue in vivo, it may be desirable to separate the downstream 13C metabolite signals resulting from the metabolic activity within the tissue of interest and those brought into the tissue by perfusion. In this study, a spectral-spatial saturation pulse that selectively saturates the signal from the metabolic products [1-13C] lactate and [1-13C] alanine was designed and implemented as outer volume suppression for localized MRSI acquisition. Preliminary in vivo results showed that the suppression pulse did not prevent the pre-polarized pyruvate from being delivered throughout the animal while it saturated the metabolites within the targeted saturation region.  相似文献   

16.
It is essential to establish whether and how environmental factors affect the reliability of [13C]methacetin breath test (13C-MBT). In 12 healthy volunteers (smokers), a standard 13C-MBT with 75 mg [13C]methacetin was performed twice in random order: on a control day without smoking and on another day with smoking two cigarettes antecedently. A considerable flattening of the curve of the momentary 13C recovery within the expiratory air was observed when the 13C-MBT was performed after smoking. The maximum of the momentary 13C recovery, D max, decreased from 37.20±2.58 to 25.39±2.29% dose/h (p=0.00052). Moreover, the time to reach D max was prolonged after cigarette smoking (26.5±3.1 vs. 16.5±1.9 min, p=0.0199). The curve of the cumulative 13C recovery on the cigarette smoking day appeared to be shifted downwards, and statistically significant differences relative to the control situation were found between the 24th and 75th minute following [13C]methacetin administration. Smoking cigarettes immediately prior to the 13C-MBT diminishes the ability of the liver to handle methacetin, and hence a possibility of such an interaction should be excluded in order to interpret the results of the test correctly.  相似文献   

17.
Abstract

Stable isotope breath tests offer a new approach to the study of digestion and fermentation of carbohydrates in man. In this study, 13C labelled peas were grown by pulsing 250ml 13CO2 into a sealed growth chamber. A second pulse was added to a portion of the peas to increase the 13C enrichment. This generated pea flour with an enrichment of 2.36 at.% excess (range 2.09–2.71 n = 3) and 8.64 atom % excess (range 7.37–9.78 n = 3) respectively. This represented incorporation of an absolute yield of 3.8% of the 13CO2 into peas in the ‘once-labelled’ treatment and 7.5% in the ‘twice-labelled’ treatment. Ingestion of a mixture of the labelled pea flour (300 mg) by two volunteers generated measurable 13CO2 excretion for breath test analysis. The profile of breath 13CO2 enrichment increased to a maximum within three hours after consuming the pea flour followed by a decrease almost back to baseline by 13 hours. Breath 13CO2 appeared to rise again after this apparent nadir at 13 hours until the end of the sampling period. Mathematical analysis of the data suggested that two peaks best described the profile of breath 13CO2 up to 13 hours. A third peak was necessary to describe the late rise in breath 13CO2 enrichment. This use of 13C enriched pea flour may provide a useful non invasive method for measurement of digestion and fermentation in vivo.  相似文献   

18.
Ergot alkaloids (sum=total alkaloids, TA) originate from the phyto-pathogenic fungus Claviceps purpurea and might exert feed intake depressing and hepatotoxic effects on animals. The aim of the study was to evaluate TA effects on performance and liver function of piglets with the [13C]methacetin breath test and two routes of tracer administration (orally, p.o.; intramuscularly, i.m.). Two ergot batches were mixed into piglet diets resulting in 21 and 17 mg TA kg?1 (Ergot-5 and -12, respectively) and compared with an ergot-free control diet. Feed intake was significantly depressed after feeding the ergot containing diets (p=<0.001). The time at maximum 13CO2 exhalation (t max) and the half-life (t 0.5) were not influenced by treatments and varied between 25 and 68 min after the p.o., and 28 and 62 min after the i.m. administration of [13C]methacetin, respectively. The cumulative 13C recovery (cPDR30) was significantly lower due to feeding the diet Ergot-5 (6.6 %) compared with the Ergot-12 (8.8 %) and the control diet (9.7 %) irrespective of the route of tracer administration (p=0.044). As a discrimination of the diet effects through both tracer administration routes is possible, the i.m. application should be preferred in piglets as this causes less stress than the oral forced administration.  相似文献   

19.
Abstract

A sufficiently stable rate of 13CO2 exhalation is necessary when the diagnostic 13CO2 breath tests are performed in healthy subjects and patients. The aim of the research was to define prerequisite conditions for kinetic breath tests in order to ensure a stable 13CO2 background. A 3-part protocol was developed. Part I: a study of the one-day variation of 13CO2 abundance in expired CO2 confirmed that shifts of the basal 13C abundance in breath are inherent in nature. Part II: a study of the variations of 13C enrichment after the ingestion of different meals and beverages showed that ingestion of food items containing C4 plant sugars, such as maize, induces a significant increase in isotopic abundance. Part III: a new test breakfast containing rice grain cereal, milk and orange juice was tested. This test meal induces no significant change on the basal 13CO2 abundance in healthy subjects. This new finding allows to avoid the fasting period normally required prior to a breath test which is sometimes difficult for children and pregnant women.  相似文献   

20.
We present a nondispersive infrared spectrometer (NDIRS) for the measurement of the 13CO2/12CO2-ratio in breath samples. A commercial NDIR spectrometer for CO2 concentration measurements in industrial process control was modified using two separate optical channels for the 13CO2 and 12CO2 detection. Cross interference due to overlapping absorption lines of both isotopic gases was successfully eliminated. The sensitivity of this device is ± 0.4‰ of the 13CO2/12CO2-ratio in a range of 2.5 to 5% of total CO2. This is sufficient for biomedical applications. Our spectrometer is small in size, cheap and simple to operate and thus a true alternative to isotope ratio mass spectrometers (IRMS). Several biomedical applications with breath samples were demonstrated and were compared in very good agreement with IRMS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号