首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An analytical methodology for the analysis of four polar organophophorus pesticides (monocrotophos, mevinphos, phosphamidon, omethoate) in water and soil samples incorporating a molecularly imprinted solid-phase extraction (MISPE) process using a monocrotophos-imprinted polymer was developed. Binding study demonstrated that the polymer showed excellent affinity and high selectivity to monocrotophos. The MISPE procedure including the clean-up step to remove any interferences was optimized. The accuracy and selectivity of the MISPE process developed were verified using a non-imprinted (blank) polymer and a classical ENVI-18 cartridge as the SPE matrix during control experiments. The use of MISPE improved the accuracy and precision of the GC method and lowered the limit of detection. The recoveries of four polar organophosphorus pesticides (OPPs) extracted from 1 L of river water at a 100 ng/L spike level were in the range of 77.5-99.1%. The recoveries of organophosphorus pesticides extracted from a 5-g soil sample at the 100 microg/kg level were in the range of 79.3-93.5%. The limit of detection varied from 10 to 32 ng/L in water and from 12 to 34 microg/kg in soil samples. The molecularly imprinted polymer (MIP) enabled the selective extraction of four organophosphorus pesticides successfully from water and soil samples, demonstrating the potential of molecularly imprinted solid-phase extraction for rapid, selective, and cost-effective sample pretreatment.  相似文献   

2.
Determination of uranium in tap water by ICP-MS   总被引:23,自引:0,他引:23  
A fast and accurate procedure has been developed for the determination of uranium at microg L(-1) level in tap and mineral water. The method is based on the direct introduction of samples, without any chemical pre-treatment, into an inductively coupled plasma mass spectrometer (ICP-MS). Uranium was determined at the mass number 238 using Rh as internal standard. The method provides a limit of detection of 2 ng L(-1) and a good repeatability with relative standard deviation values (RSD) about 3% for five independent analyses of samples containing 73 microg L(-1) of uranium. Recovery percentage values found for the determination of uranium in spiked natural samples varied between 91% and 106%. Results obtained are comparable with those found by radiochemical methods for natural samples and of the same order for the certified content of a reference material, thus indicating the accuracy of the ICP-MS procedure without the need of using isotope dilution. A series of mineral and tap waters from different parts of Spain and Morocco were analysed.  相似文献   

3.
The solid-phase microextraction (SPME) technique using a 75 mm film of carboxen/polydimethylsiloxane was applied to the analysis of chloroacetanilide herbicides (acetochlor, alachlor, butachlor, metolachlor, and propachlor) residues. The feasibility of SPME with gas chromatography electron capture detection analysis has been evaluated. The effects of experimental parameters such as magnetic stirring, salt addition, humic acid addition, pH value, and extraction time, as well as desorption temperature and time, were investigated. Analytical parameters such as linearity, repeatability and limit of detection were also evaluated. The inhibition of humic acid to the extraction of chloroacetanilide herbicides was observed. A standard addition method for calibration was recommended to reduce deviations caused by matrix interferences. The proposed method provided a simple and rapid analytical procedure for chloroacetanilide herbicides in water with limits of detection 0.002-0.065 microg/L for deionized water, and 0.005-0.22 microg/L for farm water. The relative standard deviations (n = 5) for analyses of farm water were 7-20% for 5 [corrected] microg/L chloroacetanilide herbicides. This application was illustrated by the analysis of sample collected from farm water in the Chung-hwa area, Taiwan.  相似文献   

4.
An analytical method was developed for antimony speciation and antimony(III) preconcentration in water samples. The method is based on the selective retention of Sb(III) by modified Saccharomyces cerevisiae in the presence of Sb(V). Heat, caustic and solvent pretreatments of the biomass were investigated to improve the kinetics and thermodynamics of Sb(III) uptake process at room temperature. Heating for 30 min at 80 degrees C was defined as the optimal treatment. Antimony accumulation by the cells was independent of pH (5-10) and ionic strength (0.01-0.1 mol L(-1)). 140 mg of yeast and 2h of contact were necessary to ensure quantitative sequestration of Sb(III) up to 750 microg L(-1). In these conditions, Sb(V) was not retained. Sb(V) was quantified in sorption supernatant by inductively coupled plasma mass spectrometry (ICP-MS) or inductively coupled plasma optical emission spectrometry (ICP-OES). Sb(III) was determined after elution with 40 mmol L(-1) thioglycolic acid at pH 10. A preconcentration factor close to nine was achieved for Sb(III) when 100mL of sample was processed. After preconcentration, the detection limits for Sb(III) and Sb(V) were 2 and 5 ng L(-1), respectively, using ICP-MS, 7 and 0.9 microg L(-1) using ICP-OES. The proposed method was successfully applied to the determination of Sb(III) and Sb(V) in spiked river and mineral water samples. The relative standard deviations (n=3) were in the 2-5% range at the tenth microg L(-1) level and less than 10% at the lowest Sb(III) and Sb(V) tested concentration (0.1 microg L(-1)). Corrected recoveries were in all cases close to 100%.  相似文献   

5.
Quantitative determination of trace glyphosate and phosphate in waters was achieved by coupling ion chromatography (IC) separation with inductively coupled plasma mass spectrometry (ICP-MS) detection. The separation of glyphosate and phosphate on a polymer anion-exchange column (Dionex IonPac AS16, 4.0 mm x 250 mm) was obtained by eluting them with 20 mM citric acid at 0.50 mL min(-1), and the analytes were detected directly and selectively by ICP-MS at m/z = 31. Parameters affecting their chromatographic behaviors and ICP-MS characteristics were systematically examined. Based on a 500-microL sample injection volume, the detection limits were 0.7 microgL(-1) for both glyphosate and phosphate, and the calibrations were linear up to 400 microgL(-1). Polyphosphates, aminomethylphosphonic acid (the major metabolite of glyphosate), non-polar and other polar phosphorus-containing pesticides showed different chromatographic behaviors from the analytes of interest and therefore did not interference. The determination was also interference free from the matrix anions (nitrate, nitrite, sulphate, chloride, etc.) and metallic ions. The analysis of certified reference material, drinking water, reservoir water and Newater yielded satisfactory results with spiked recoveries of 97.1-107.0% and relative standard deviations of < or = 7.4% (n = 3). Compared to other reported methods for glyphosate and phosphate, the developed IC-ICP-MS method is sensitive and simple, and does not require any chemical derivatization, sample preconcentration and mobile phase conductivity suppression.  相似文献   

6.
A liquid chromatography/electrospray ionization/mass spectrometry method was reported for the compliance analysis of seven phenylurea compounds and two related herbicides (tebuthiuron and propanil) in drinking water. The volumes of the sample and final extract used in the method were 500 mL and 10 mL, respectively. The obtained method detection limits were less than 0.03 microg/L, and the mean recoveries were 74-128% with a relative standard deviation of 2.6-8.3% for all the studied compounds. The peak-to-peak signal-to-noise ratios ranged from 3.3 for cis-siduron to 34.2 for fluometuron. The accuracy and precision resulting from reagent and drinking water samples fortified at higher concentration levels were similar to these results. Several analytes were detected in the drinking water samples, including tebuthiuron at 0.5 microg/L, propanil at 0.7 microg/L, diuron at 0.1-2.1 microg/L, and linuron at 0.1-0.8 microg/L.  相似文献   

7.
Flow injection analysis (FIA) with ESI-MS and ion chromatography (IC) with inductively coupled plasma-MS (ICP-MS) as the complementary technique have been explored for the determination of metal ions as their metal-EDTA complexes. ESI-MS enabled the identification of metal-EDTA complexes such as [Mn(EDTA)](2-), [Co(EDTA)](2-), [Ni(EDTA)](2-), [Cu(EDTA)](2-), [Zn(EDTA)](2-), [Pb(EDTA)](2-), and [Fe(EDTA)](1-) and their MS spectral showed that these metal-EDTA complexes were present in solution. Based on the ESI-MS, ion chromatographic separation and ICP-MS detection of these complexes are possible because IC-ICP-MS requires stable metal-EDTA complex during the chromatographic separation. The separation of these metal-EDTA complexes was achieved on an anion-exchange column with a mobile phase containing 30 mM NH(4)(HPO(4))(2) at pH 7.5 within 7 min with ICP-MS providing element specific detection. The ICP-MS LODs for the metal-EDTA were in the range of 0.1-0.5 microg/L with the exception of Fe (15 microg/L). The proposed method was a simple procedure for sample processing, using direct injection of sample without removal of sample matrix and was successfully applied to the determination of metal-EDTA complexes in real samples.  相似文献   

8.
Pu X  Hu B  Jiang Z  Huang C 《The Analyst》2005,130(8):1175-1181
A method has been developed for the speciation of trace dissolved Fe(II) and Fe(III) in water by coupling gallic acid (GA) modified nanometer-sized alumina micro-column separation with inductively coupled plasma mass spectrometry (ICP-MS). The separation of Fe(II) and Fe(III) was achieved based on the obvious difference in reaction kinetics between Fe(II) and Fe(III) with GA. Fe(III) was selectively retained on the micro-column at pH 5.5-6.5, while Fe(II) could not be retained by the micro-column at the whole tested pH range of 1.0-6.5, and passed through the micro-column. The Fe(II) can be determined by ICP-MS directly without preconcentration/separation procedure, while Fe(III) retained on the micro-column was then eluted with 1.0 mL of 1 mol L(-1) HCl and determined by ICP-MS. The parameters affecting the separation of Fe(II) and Fe(III) were investigated systematically and the optimum separation conditions were established. Under the optimized conditions, the detection limits of 0.48 microg L(-1) and 0.24 microg L(-1) with relative standard deviation of 5.6% and 4.3%(C= 5 microg L(-1), n= 7) for Fe(II) and Fe(III) were found, respectively. No obvious effect on the speciation of Fe(II) and Fe(III) was found with the change of the ratio of Fe(II) and Fe(III) from 0 ratio 10 to 10 ratio 0. The proposed method was applied for the determination of trace Fe(II) and Fe(III) in environmental water and the recoveries for spiked samples were found to be in the range of 97-105%.  相似文献   

9.
This work describes the optimization of a fully automated method based on on-line solid-phase extraction-liquid chromatography-electrospray-tandem mass spectrometry (SPE-LC-ESI-MS/MS) for the simultaneous determination of 17 medium to polar pesticides in water. The list of target analytes included organophosphates, triazines, phenylureas, anilides, chloroacetanilides, acidic herbicides and thiocarbamates. Detection limits achieved were below 5 ng/L for all compounds except metolachlor (12 ng/L), alachlor (17 ng/L), malathion (36 ng/L) and fenitrothion (50 ng/L). The method developed was used to investigate the occurrence of the target pesticides in a total of 52 water samples collected monthly (from May to August 2005) at 14 selected locations in the rice cultivation area of the Ebro river delta. The study showed high levels, in the microg/L range, of bentazone, MCPA, propanil, molinate and atrazine, in basically all the samples investigated. The remaining pesticides were present at lower levels (<0.1 microg/L) or only detected sporadically (e.g. fenitrothion and malathion). The sampling campaign performed in July showed comparatively higher levels than the other three campaigns.  相似文献   

10.
Guo M  Tan Z  Wu H  Li Z  Zhai Y 《色谱》2012,30(3):256-261
建立了同时测定贝类中大田软海绵酸(okadaic acid, OA)及其衍生物鳍藻毒素(dinophysistoxin-1, DTX-1)、蛤毒素(pectenotoxin-2, PTX-2)和虾夷扇贝毒素(yessotoxin, YTX)的液相色谱-串联质谱分析方法。样品经甲醇提取,固相萃取柱净化,C18色谱柱分离,经含甲酸和甲酸铵的乙腈-水溶液为流动相梯度洗脱,选择反应监测(SRM)模式检测,正、负离子切换扫描,基质标准校正,外标法定量。结果表明,OA、DTX-1和YTX的线性范围为2.0~200.0 μg/L,定量限(以信噪比(S/N)≥10计)为1.0 μg/kg; PTX-2的线性范围为1.0~100.0 μg/L,定量限为0.5 μg/kg;几种化合物的添加平均回收率为83.1%~105.7%,相对标准偏差(RSD)为3.16%~9.29%。成功应用本法对黄海灵山湾海域采集的贝类样品进行了分析,发现部分样品中含有大田软海绵酸、鳍藻毒素、蛤毒素和虾夷扇贝毒素。  相似文献   

11.
It was demonstrated that four out of six of the very polar organophosphorus pesticides (OPs), i.e. acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl and vamidothion, could not be extracted from water using commonly available SPE cartridges. In addition, GC analysis on all six compounds was found to be troublesome due to their polar and thermolabile character. This initiated the development of an alternative highly sensitive and selective method for the determination of the above mentioned very polar OPs in water, based on LC-MS. Large volume (1 ml) water samples were directly injected onto an RP18 HPLC column with a polar endcapping. The latter was essential for obtaining retention and maintaining column performance under 100% aqueous conditions during the sampling. The compounds were ionized using atmospheric pressure chemical ionization and detected on a tandem mass spectrometer operated in multiple reaction-monitoring mode. The detection limits were in the range of 0.01-0.03 microg/l. Compared to conventional GC methods, the developed LC-MS procedure is very straightforward, fast and more reliable. This application demonstrates the applicability of LC-MS for analysis of polar OPs in surface, ground and drinking water, as a more favourable alternative to GC.  相似文献   

12.
A method combining hydrophilic interaction liquid chromatography (HILIC) with tandem mass spectrometry (MS/MS) was developed for the determination of polar organophosphorus pesticides (OPPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl, and vamidothion) in water samples. To extract the polar OPPs and minimize matrix effects from the water sample, an activated carbon cartridge was used for pretreatment. After pretreatment of the water sample, the eluate from the activated carbon cartridge was directly injected into the HILIC/MS/MS system. The OPPs were separated on an Atlantis HILIC silica column by isocratic elution with a mixture of acetonitrile, isopropanol, and ammonium formate buffer as a mobile phase, and they were detected by positive electrospray ionization MS/MS in the selected reaction monitoring mode. The method was validated at 0.05, 0.5, and 5 microg/L levels in water samples, and the recoveries of polar OPPs were between 76.4 and 98.6%. The limits of detection were between 0.13 and 1.0 pg on-column, and the limits of quantification were between 0.43 and 3.4 pg on-column. The method can be applied to the determination of trace amounts of OPPs in environmental water samples.  相似文献   

13.
建立了一种非衍生化高效液相色谱-串联质谱快速检测生物体液中草甘膦、草铵膦及其代谢物等8种极性农药的方法。8种极性农药经Metrosep A Supp 5阴离子色谱柱(150 mm×4.0 mm,5μm)分离,以纯水-200 mmol/L碳酸氢铵溶液(含0.1%氨水)为流动相进行梯度洗脱,负离子多反应监测(MRM)模式进行检测。实验结果表明,8种极性农药在0.5~50 ng/mL范围内线性关系良好(r2>0.99),检出限(S/N≥3)为0.08~0.3 ng/mL,定量下限(S/N≥10)为0.3~1 ng/mL。方法的基质效应为86.5%~106%,目标化合物的回收率为81.5%~114%,日内相对标准偏差(RSD)为0.30%~2.8%,日间RSD为0.50%~5.3%。该方法无需复杂的衍生化过程,简便快速、灵敏度高、稳定性好,适用于生物体液中8种极性农药的检测。  相似文献   

14.
A reversed phase ion-pairing high performance liquid chromatographic (RPIP-HPLC) method is developed for the separation of two phosphorus herbicides, Glufosinate and Glyphosate as well as Aminomethylphosphonic acid (AMPA), the major metabolite of Glyphosate. Tetrabutylammonium hydroxide is used as the ion-pairing reagent in conjunction with an ammonium acetate/acetic acid buffering system at pH 4.7. An inductively coupled plasma mass spectrometer (ICP-MS) is coupled to the chromatographic system to detect the herbicides at m/z = 31P. Historically, phosphorus has been recognized as one of the elements difficult to analyze in argon plasma. This is due to its relatively high ionization potential (10.5 eV) as well as the inherent presence of the polyatomic interferences 14N16O1H+ and 15N16O+ overlapping its only isotope at m/z = 31. An octapole reaction cell is utilized to minimize the isobaric polyatomic interferences and to obtain the highest signal-to-background ratio. Detection limits were found to be in the low ppt range (25-32 ng/l). The developed method is successfully applied to the analysis of water samples collected from the Ohio River and spiked with a standard compounds at a level of 20 microg/l.  相似文献   

15.
A new method for the determination of nine haloacetic acids (HAAs) with ion chromatography (IC) coupled to inductively coupled plasma mass spectrometry (ICP-MS) was developed. With the very hydrophilic anion-exchange column and steep gradient of sodium hydroxide, the nine HAAs could be well separated in 15 min. After suppression with an ASRS suppressor that was introduced in between IC and ICP-MS, the background was much decreased, the interference caused by sodium ion present in eluent was removed, and the sensitivities of HAAs were greatly improved. The chlorinated and brominated HAAs could be detected as 35ClO and 79Br without interference of the matrix due to the elemental selective ICP-MS. The detection limits for mono-, di-, trichloroacetic acids were between 15.6 and 23.6 microg/l. For the other six bromine-containing HAAs, the detection limits were between 0.34 and 0.99 microg/l. With the pretreatment of OnGuard Ag cartridge to remove high concentration of chloride in sample, the developed method could be applied to the determination of HAAs in many drinking water matrices.  相似文献   

16.
The determination of imidacloprid and its main metabolite (6-chloronicotinic acid) in honeybees was performed by liquid chromatography with post-column photochemical derivatisation in alkaline medium and fluorescence detection. The compounds were extracted from honeybees with acetone under ultrasound conditions prior to liquid-liquid partition with dichloromethane. The separation of extract components was performed using a 50 mm x 4.6 mm i.d. short column packed with 5 microm Aquasil C(18) using an acetonitrile:water gradient program as mobile phase. Injection of samples in 0.1 mol L(-1) H(3)PO(4)/KH(2)PO(4) buffer solution (pH 3) improved the chromatographic separation between the most polar components of matrix and the 6-chloronicotinic acid. Matrix components were removed to waste using an on-line clean-up method previously to post-column reaction. Limits of quantification were 0.3 and 5.0 microg L(-1) (corresponding to 1.2 and 20.0 microg kg(-1) in the honeybee sample) for imidacloprid and 6-chloronicotinic acid, respectively. The recovery was ranged from 80.2 to 91.7% with a relative standard deviation lower than 9.0%.  相似文献   

17.
The performance of mass spectrometric (MS) detection and UV detection in combination with reversed-phase liquid chromatography without and with the use of coupled column RPLC (LC-LC) has been compared for the trace analysis of phenylurea herbicides in environmental waters. The selected samples of this comparative study originated from an inter-laboratory study. For both detection modes, a 50 mm x 4.6 mm I.D. column and a 100 mm x 4.6 mm I.D. column packed with 3 microm C18 were used as the first (C-1) and second (C-2) column, respectively. Atmospheric pressure chemical ionization mass spectrometry was performed on a magnetic sector instrument. The LC-LC-MS analysis was carried out on-line by means of direct large volume (11.7 ml) injection (LVI). The performance of both on-line (LVI, 4 ml of sample) and off-line LC-LC-UV (244 nm) analysis was investigated. The latter procedure consisted of a solid-phase extraction (SPE) of 250 ml of water sample on a 500 mg C18 cartridge. The comparative study showed that LC-LC-MS is more selective then LC-LC-UV and, in most cases, more sensitive. The LVI-LC-LC-MS approach combines direct quantification and confirmation of most of the analytes down to a level of 0.01 microg/l in water samples in less then 30 min. As regards LC-LC-UV, the off-line method appeared to be a more viable approach in comparison with the on-line procedure. This method allows the screening of phenylurea's in various types of water samples down to a level of at least 0.05 microg/l. On-line analysis with LVI provided marginal sensitivity (limits of detection of about 0.1 microg/l) and selectivity was sometimes less in case of surface water samples. Both the on-line LVI-LC-LC-MS method and the LC-LC-UV method using off-line SPE were validated by analysing a series of real-life reference samples. These samples were part of an inter-laboratory test and contained residues of herbicides ranging from 0.02 to 0.8 microg/l. Beside good correlation between the methods the data agreed very well with the true values of the samples.  相似文献   

18.
A solid-phase microextraction (SPME) procedure was developed for the determination of 10 selected organonitrogen herbicides (s-ethyl dibropylthiocarbamate [EPTC], molinate, propachlor, trifluralin, simazine, atrazine, propazine, terbuthylazine, alachlor, and prometryn) and was tested with various natural waters. Gas chromatography coupled with flame thermionic and mass spectrometric detection was used for quantitation. For this purpose, polydimethylsiloxane and polyacrylate fibers were used and the factors affecting the SPME process such as pH, ionic strength, methanol content, memory effect, stirring rate, and adsorption-time profile were investigated and optimized. By using spiked liquid chromatography water, optimal factors were determined to be 25% salt, <0.5% methanol, stirring rate of 960 rpm, pH 4, and an equilibrium time of 30 min. These conditions were used in further studies of the fibers and in analysis of natural water samples. The method was applied to spiked natural waters such as ground water, sea water, lake water, and river water at a concentration range of 0.5-10 microg/L. Limits of detection ranged from 5 to 90 ng/L, and precision ranged from 5 to 15% (as relative standard deviation), depending on the pesticide, fiber, and detector used. The recoveries of herbicides were 70.2-118.4%, and the average r2 values of the calibration curves were >0.99 for all analytes. The results demonstrate the suitability of the SPME method to determine these organonitrogen herbicides in various natural waters. River water samples originating from the Epirus region (Northwestern Greece) were analyzed to verify the performance of the optimized method by comparing the results obtained by SPME with those obtained by using conventional solid-phase extraction of the selected herbicides.  相似文献   

19.
The total mercury content in urine was determined by inductively coupled plasma mass spectrometry with the so-called cold vapour method after on-line oxidative treatment of the sample in a microwave oven (FI-MW-CV-ICPMS). Use of a KBr/KBrO(3) mixture, microwave digestion, and the final oxidation with KMnO(4), assure the complete recovery of the organic forms of Hg which would be difficult to determine otherwise if using only the CV-ICPMS apparatus. Quantitative recoveries were obtained for phenyl Hg chloride (PMC), dimethyl Hg (DMM), Hg acetate (MA) and methyl Hg chloride (MMC). Use of automatic flow injection microwave systems (FI-MW) for sample treatment reduces environmental contamination and allows detection limits suitable for the determination of reference values. Since no certified reference materials were commercially available in the concentration ranges of interest, the accuracy of the proposed procedure has been assessed by analysing a series of urine samples with two independent techniques, ICP-MS and AAS. When using the FI-MW-CV-ICP-MS technique, the detection limit was assessed at 0.03microg/L Hg, while with FI-MW-CV-AAS it was 0.2microg/L Hg. The precision of the method was less than 2-3% for FI-MW-CV-ICP-MS and about 3-5% for FI-MV-CV-AAS at concentrations below 1microg/L Hg. These results show that ICP-MS can be considered as a "reference technique" for the determination of total urinary Hg at very low concentrations, such as are present in non-exposed subjects.  相似文献   

20.
In order to determine low levels of Cd in urine samples, we tried to remove Mo interference using ICP-MS with a dynamic reaction-cell technique, but failed due to the low sensitivity and the variance with the standards. We then performed solid-phase extraction (SPE) before the ICP-MS measurement. A commercially available chelating resin, NOBIAS PA-1, was used for SPE, and could effectively remove Mo from urine samples, permitting the accurate determination of Cd by ICP-MS. This SPE-ICP-MS method gave 0.012 microg Cd L(-1) as the method limit of quantification, and the mean recovery of Cd spiked with 0.0505 and 5.05 microg L(-1) was 93.1 and 97.6%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号