首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The original article to which this Erratum refers was published in Rapid Commun. Mass Spectrom. 2004; 18 : 2059–2064  相似文献   

2.
A simple and rapid procedure for the determination of 22 organophosphorous pesticides (bromophos-ethyl, bromophos-methyl, chlorfenvinphos, chlorpyriphos, demethon-S-methylsulfon, diazinon, dichlorvos, dicrotophos, dimethoate, disulfoton, edifenphos, fenitrothion, fenthion, malathion, methidathion, mevinphos, monocrotophos, omethoate, parathion-ethyl, parathion-methyl, phosphamidon, and quinalphos) in human blood using headspace (HS) solid-phase microextraction (SPME) and gas chromatography (GC)-mass spectrometry (MS) is presented. The effects of various sample additions, incubation temperatures, absorption times, desorption times, and depths of fiber insertion into the injection port of the GC are optimized to enhance the sensitivity of the procedure. The recoveries of spiked blood samples are determined between 70% and 95% compared with samples prepared in water, and absolute recoveries are in the range between 0.1% and 19.6%. For quantitation in the single ion monitoring mode, linearity is established over concentration ranges from 0.025 to 5.0 microg/g with excellent coefficients of correlation (0.991-0.998). The detection limits are in the range between 0.01 and 0.3 microg/g. The time for analysis is 44 min per sample including extraction and GC-MS analysis. HS-SPME in combination with GC-MS is an effective method for the determination of organophosphorous pesticides in human blood and shows a great potential for use in rapid on-site analytical work, which is highly demanded in clinical and forensic toxicology.  相似文献   

3.
This paper describes a method for the sensitive, selective, and solvent-free determination of six oxazole fungicide residues (hymexazol, drazoxolon, vinclozolin, chlozolinate, oxadixyl, and famoxadone) in malt beverages. Direct immersion solid-phase microextraction (DI-SPME) coupled to gas chromatography with mass spectrometry in the selected ion monitoring mode, GC-MS(SIM), is used. A comparison of the optimal fiber used, a polar carbowax-divinylbenzene 70-microm fiber, and a nonpolar polydimethylsiloxane 100-microm fiber was carried out. Optimal extraction conditions were 60 degrees C and an extraction time of 30 min under continuous stirring. Desorption was carried out at 250 degrees C for 5 min. Detection limits ranged from 0.006 to 0.3 microg L(-1) at a signal to noise ratio of 3, depending on the compound. The proposed method was successfully applied to malt beverages including malt, beer, and whisky, and none of the samples contained residues higher than detection limits.  相似文献   

4.
The direct coupling between ionic liquid-based single-drop microextraction and gas chromatography/mass spectrometry is proposed for the rapid and simple determination of benzene, toluene, ethylbenzene and xylenes isomers (BTEX) in water samples. The extraction procedure exploits not only the high affinity of the selected ionic liquid (1-methyl-3-octyl-imidazolium hexaflourophosphate) to these aromatic compounds but also its special properties like viscosity, low vapour pressure and immiscibility with water. All the variables involved in the extraction process have been studied in depth. The developed method allows the determination of these single-ring compounds in water under the reference concentration level fixed by the international legislation. In this case, limits of detection were in the range 20 ng L(-1) (obtained for benzene) and 91 ng L(-1) (for o-xylene). The repeatability of the proposed method, expressed as RSD (n=5), varied between 3.0% (o-xylene) and 5.2% (toluene).  相似文献   

5.
A new method is described for the qualitative and quantitative analysis of cyanide, a very short-acting and powerful toxic agent, in human whole blood. It involves the conversion of cyanide into hydrogen cyanide and its subsequent headspace solid-phase microextraction (HS-SPME) and detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode. Optimizing the conditions for the GC/MS (type of column, injection conditions, temperature program) and SPME (choice of SPME fiber, effect of salts, adsorption and desorption times, adsorption temperature) led to the choice of a 75-microm carboxen/polydimethylsiloxane SPME fiber, with D3-acetonitrile as internal standard, and a capillary GC column with a polar stationary phase. Method validation was carried out in terms of linearity, precision and accuracy in both aqueous solutions and blood. The limit of detection (LOD) and limit of quantitation (LOQ) were determined only in aqueous solutions. The assay is linear over three orders of magnitude (water 0.01-10, blood 0.05-10 microg/mL); and the LOD and LOQ in water were 0.006 and 0.01 microg/mL, respectively. Good intra- and inter-assay precision was obtained, always <8%. The method is simple, fast and sensitive enough for the rapid diagnosis of cyanide intoxication in clinical and forensic toxicology.  相似文献   

6.
The therapeutic importance of platinum (Pt) compounds, the growing accessibility of gas chromatography/mass spectrometry (GC/MS) systems in clinical laboratories, and the lack of a mass spectrometric method for the determination of Pt in biological samples motivated us to develop an isotope dilution GC/MS assay for Pt. The method is based on the use of lithium bis(trifluoroethyl) dithiocarbamate, Li(FDEDTC), as a chelating agent and enriched 192Pt for isotope dilution. Conditions were optimized for the precise and accurate determination of isotope ratios of Pt by using a 10-m DB-l fused silica capillary column and a reverse-geometry double-focusing mass spectrometer with selected ion monitoring. An overall precision of 1% was obtained by combining within-run precision and between-run precision at the 10-ng level. No appreciable memory effect was observed when samples with different isotope ratios were analyzed sequentially. The method was validated by the quantitation of Pt in National Institute of Standards and Technology freeze-dried urine sample SRM 2670. A concentration value of 125 ± 6 /Lg/L (n = 6) was obtained by using four different sets of isotope ratios in the molecular ion and supports the National Institute of Standards and Technology recommended value of 120 ± ? μg/L. Limits-of-quantitation, estimated at 3 μg/L, are made possible by the high sensitivity of the method and the low blank value for Pt.  相似文献   

7.
8.
A simple analytical procedure based on single-drop microextraction combined with in-syringe derivatization and GC-MS was developed for determination of some phenolic acids in fruits and fruit juices. Cinnamic acid, o-coumaric acid, caffeic acid, and p-hydroxybenzoic acid were used as model compounds. The analytes were extracted from a 3-mL sample solution using 2.5 microL of hexyl acetate. The extracted phenolic acids were derivatized inside the syringe barrel using 0.7 microL of N,O-bis(trimethylsilyl)acetamide before injection into the GC-MS. The influence of derivatization conditions on the yield of in-syringe silylation was studied. Experimental SDME parameters such as selection of organic solvent, solvent volume, extraction time, extraction temperature, pH, and ionic strength of the solution on the extraction performance were studied. The method provided fairly good precision for all compounds (2.4-11.9%). Detection limits were found to be between 0.6 and 164 ng/mL within an extraction time of 20 min in the GC-MS full scan mode.  相似文献   

9.
In the current work, a simple, rapid, accurate and inexpensive method was developed for the determination of acetone in human blood. The proposed method is based on derivatization with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA), followed by headspace liquid-phase microextraction (HS-LPME) and gas chromatography/mass spectrometry (GC/MS). In the present method, acetone in blood samples was derivatized with PFBHA and acetone oxime formed in several seconds. The formed oxime was enriched by HS-LPME using the organic solvent film (OSF) formed in a microsyringe barrel as extraction interface. Finally, the enriched oxime was analyzed by GC/MS in electron ionization (EI) mode. HS-LPME parameters including solvent, syringe plunger withdrawal rate, sampling volume, and extraction cycle were optimized and the method reproducibility, linearity, recovery and detection limit were studied. The proposed method was applied to determination of acetone in diabetes blood and normal blood. It has been shown that derivatization with HS-LPME and GC/MS is an alternative method for determination of the diabetes biomarker, acetone, in blood samples.  相似文献   

10.
A simple and rapid method based on drop-to-drop solvent microextraction (DDSME) coupled with gas chromatography/mass spectrometry (GC/MS) has been successfully applied for the pharmacokinetic studies of trimeprazine in 8 microL of urine and blood samples of rats. Several factors that influenced the extraction efficiency of DDSME, such as selection of organic solvent, extraction time, exposure volume of organic phase, addition of salt and pH, were optimized. Linearity was obtained over the concentration ranges of 0.2-10, 0.25-7.0 and 0.5-6.0 microg/mL with correlation coefficients of 0.998, 0.996 and 0.993 in deionized water, urine and blood samples of rats, respectively. The limits of detection (LODs) of trimeprazine were 0.05, 0.06 and 0.1 microg/mL in deionized water, urine and blood samples. The concentrations of trimeprazine obtained in urine and blood samples of rats were 0.21-1.25 and 2.72-0.22 microg/mL, respectively, after a single intravenous administration of this drug. The enrichment factors and LOD values obtained by DDSME coupled to GC/MS were compared with those of hollow fiber liquid-phase microextraction (HF-LPME) combined with GC/MS. We believe that this novel approach can be very useful in clinical application since only one microdrop of biological samples was required to perform the pharmacokinetic studies from rats, so the sample pretreatments for animal experiments can be very easy too.  相似文献   

11.
A method for the determination of the antiepileptic drug valproic acid and 14 of its metabolites in serum and urine by gas chromatography/mass spectrometry with selected ion monitoring of the trimethylsilylated derivatives has been developed. Sample preparation, including hydrolysis of VPA-conjugates and removal of urea in urine is carried out at pH 5.0 and is rapid and simple. The samples are extracted with ethyl acetate and the concentrated extracts are trimethylsilylated. Analysis with adequate separation of metabolites is achieved with a DB 1701 fused silica (Megabore) capillary column. The method exhibits high recovery and reproducibility and is sufficiently sensitive and selective for analysis of small sample volumes. Application of the method for screening patient serum and urine samples for unusual metabolite patterns, with possible predictive value for early detection of liver injury, is presented.  相似文献   

12.
D.C. Kapsimali 《Talanta》2010,80(3):1311-62
Two different derivatizing reagents were tested for the development of a fast and sensitive method for the determination of selenites (SeIV) in human urine. The reagents were sodium tetraethylborate (NaBEt4) and tetraphenylborate (NaBPh4), respectively, and the procedure is based on in situ derivatization of selenites in aqueous medium. Selenite ions are converted to diethylselenide (DESe) or diphenylselenide (DPhSe) and subsequently collected from the headspace by solid phase microextraction using a silica fiber coated with polydimethylsiloxane (HS-SPME). Finally, they are quantitated by GC/MS in SIM mode. Ethylation over phenylation was proved preferable for the headspace extraction because of the higher volatility of the diethyl-derivative of selenites. The optimization of the HS-SPME conditions was performed both in aqueous and urinary solutions. Under the optimum conditions for HS-SPME, the gas chromatographic conditions were also optimized. Between the two alkylation reagents tetraethylborate was proved more efficient and the quantitation was satisfactory. Aqueous certified reference materials were analyzed to evaluate the accuracy of the method. The precision of the method was 4.2% and the calculated detection limit was 0.05 μg L−1 for human urine.  相似文献   

13.
A new, simple and rapid procedure for the determination of dimethoate in urine and blood samples was developed using direct immersion solid-phase microextraction and gas chromatography/mass spectrometry. This technique required only 0.1 mL of sample, and ethion was used as internal standard. Two types of coated fibre were compared (100 microm polydimethylsiloxane, and 65 microm Carbowax/divinylbenzene). Other parameters, such as extraction temperature, adsorption and desorption time, salt addition, agitation and pH, were optimized to enhance the sensitivity of the method. Limits of detection (LODs) and quantitation (LOQs) were 50 and 100 ng/mL for urine and 200 and 500 ng/mL for blood, respectively. The method was found to be linear between the LOQ and 40 microg/mL for urine, and between the LOQ and 50 microg/mL for blood, with correlation coefficients ranging from 0.9923-0.9996. Precision (intra- and interday) and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The mean absolute recoveries of dimethoate were 1.24 and 0.50% for urine and blood, respectively. Because of its simplicity and the fact that small volumes of sample are used, the described method can be successfully used in the diagnosis of poisoning by this pesticide, namely in those situations where the sample volume is limited, as frequently occurs in forensic toxicology.  相似文献   

14.
15.
A method for the simultaneous determination of amphetamines and ketamines (ketamine, norketamine and dehydronorketamine) in urine samples by gas chromatography/mass spectrometry was developed and validated. Urine samples were extracted with organic solvent and derivatized with trifluoroacetic anhydride (TFAA). The limits of detection and limits of quantification for each analyte were lower than 19 and 30 ng/mL, respectively. Within-day and between-day precisions were within 0.5% and 10.6%, respectively. Biases for three levels of control samples were within -10.6% and +7.8%. The concentration of dehydronorketamine was greater than those of ketamine or norketamine in 19 of 35 ketamine-positive samples. A group of 110 human urine samples previously determined to contain at least one of the target analytes was analyzed using the new method, and excellent agreement was observed with previous results.  相似文献   

16.
A headspace solid‐phase micro‐extraction (HS‐SPME) method was employed in order to study the effect of storage conditions of human urine samples spiked with tributyltin (TBT) using gas chromatography and mass spectrometry. To render the analyte more volatile, the derivatization (ethylation) was made in situ by sodium tetraethylborate (NaBEt4), which was added directly to dilute unpreserved urine samples and in buffers of similar acidity. The stability of TBT in human urine matrix was compared with the stability of TBT in buffer solutions of similar pH value. Critical parameters of storage conditions such as temperature and time, which affect the stability of TBT in this kind of matrix, were examined extensively. The tests showed that the stability of TBT remains practically satisfactory for a maximum of 2 days of storage either at +4 or 20°C. Greater variations were observed in the concentration of TBT in human urine samples at +4°C and lower ones at ?20°C over a month's storage. The freeze–thaw cycles have negative effect on the stability and should be kept to a minimum. The results from spiked urine samples are also discussed in comparison to those acquired from buffer solutions of equal TBT concentration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
Myung SW  Kim S  Park JH  Kim M  Lee JC  Kim TJ 《The Analyst》1999,124(9):1283-1286
A simple and rapid analytical method is presented for the determination of pethidine (meperidine) and methadone in human urine using solid-phase microextraction (SPME) and gas chromatography with nitrogen-phosphorus detection (GC-NPD). After the analytes had been partitioned between an extracting phase and the aqueous sample matrix, the needle of the coating fiber assembly was injected directly into the GC injector. The analytes were thermally desorbed in the heated injector (240 degrees C) and subsequently separated and detected by the GC-NPD system. The factors influencing the SPME method, such as the salt (NaCl) effect (15%), pH (pH 11), and equilibration time (30 min), were optimized. The calibration graphs for urine samples showed a good linearity. The detection limit was below 1 ng ml-1 for both drugs.  相似文献   

18.
Pentazocine has been found to be measurable with much higher sensitivity by gas chromatography (GC)/surface ionization (SI) organic mass spectrometry (OMS) than by the conventional GC/electron ionization (EI) mass spectrometry. The compound was extracted from human whole blood and urine with Sep-Pak C(18) cartridges before analysis by GC/SIOMS; recoveries were > 96.6% for both samples. The calibration curves were linear in the range 6.25-100 ng ml(-1) and the detection limits were 500 pg ml(-1) of a sample by selected ion monitoring (SIM) with GC/SIOMS. The intra- and inter-day relative standard deviations for the determination of pentazocine in whole blood and urine were not greater than 9.6%. The sensitivity for pentazocine obtained by SI-SIM was about 60 times higher than that obtained by EI-SIM. To validate the present GC/SIOMS method for pentazocine, whole blood and urine samples collected from two volunteers 1-6 h after intramuscular injection of 15 mg of pentazocine were analyzed. The concentrations were 13.5-59.3 ng ml(-1) for whole blood and 0.39-4.00 microg ml(-1) for urine.  相似文献   

19.
An integrated analytical procedure for polychlorinated biphenyl (PCB) multiresidues in environmental samples has been developed and applied to well-characterized samples. PCB residues are characterized and quantified using wall coated open tubular column (WCOT) gas chromatography or HRGC/MS-selected ion monitoring. An automated data system based on a Spectra Physics SP-4200 computing integrator is used to select and quantitate peaks of individual congeners and homolog groups. This procedure consistently yields results with a reproducibility within 3 percent for HRGC-ECD and 3.7 percent for HRGC/MS-SIM technique respectively.  相似文献   

20.
Angelica sinensis (danggui in Chinese) is a common traditional Chinese medicine (TCM), and its essential oil has been used for the treatment of many diseases such as hepatic fibrosis. Z-Ligustilide has been found to be an important active component in the TCM essential oil. In this work, for the first time, headspace single-drop microextraction (HS-SDME) followed by gas chromatography-mass spectrometry (GC-MS) was developed for the determination of Z-ligustilide in rabbit plasma after oral administration of essential oil of danggui. The extraction parameters of solvent selection, solvent volume, sample temperature, extraction time, stirring rate, and ion strength were systemically optimized. Furthermore, the method linearity, detection limit, and precision were also investigated. It was shown that the proposed method provided good linearity (0.02-20 microg/mL, R2 = 0.997), low detection limit (10 ng/mL), and good precision (RSD value less than 9%). Finally, HS-SDME followed by GC/MS was used for fast determination of Z-ligustilide in rabbit plasma at different time intervals after oral administration of danggui essential oil. The experimental results suggest that HS-SDME followed by GC/MS is a simple, sensitive, and low-cost method for the determination of Z-ligustilide in plasma, and a low-cost approach to pharmacokinetics studies of active components in TCMs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号