首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
A systematic investigation of a novel epoxide and thioepoxide ring expansion reaction promoted by gaseous acylium and thioacylium ions is reported. As ab initio calculations predict, and 18O-labeling and MS3 pentaquadrupole experiments demonstrate, the reaction proceeds by initial O(S)-acylation of the (thio)epoxides followed by rapid intramolecular nucleophilic attack that results in three-to-five-membered ring expansion, and forms cyclic 1,3-dioxolanylium, 1,3-oxathiolanylium, or 1,3-dithiolanylium ions. This gas-phase reaction is analogous to a condensed-phase reaction long since described by H. Meerwein (Chem. Ber. 1955, 67, 374), and is termed as "the gas-phase Meerwein reaction"; it occurs often to great extents or even exclusively, but in some cases, particularly for the most basic (thio)epoxides and the most acidic (thio)acylium ions, proton transfer (eventually hydride abstraction) competes efficiently, or even dominates. When (thio)epoxides react with (thio)-acylium ions, the reaction promotes O(S)-scrambling; when epoxides react with thioacylium ions and the adducts are dissociated, it promotes S/O replacement. An analogous four-to-six-membered ring expansion also occurs predominantly in reactions of trimethylene oxide with acylium and thioacylium ions.  相似文献   

2.
Ethylnitrilium ion can be generated by protonation of acetonitrile (when used as the LC-MS mobile phase) under the conditions of atmospheric pressure ionizations, including electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) as well as atmospheric pressure photoionization (APPI). Ethylnitrilium ion ( CH3 - C o \mathop N+ HCH_3 - C \equiv \mathop N\limits^ + H and its canonical form CH3 - \mathop C+ = NHCH_3 - \mathop C\limits^ + = NH) is shown to efficiently undergo the gas-phase Meerwein reaction with epoxides. This reaction proceeds by the initial formation of an oxonium ion followed by three-to-five-membered ring expansion via an intramolecular nucleophilic attack to yield the Meerwein reaction products. The density functional theory (DFT) calculations at the B3LYP/6-311 + G(d,p) level show that the gas-phase Meerwein reaction is thermodynamically favorable. Collision-induced dissociation (CID) of the Meerwein reaction products yields the net oxygen-by-nitrogen replacement of epoxides with a characteristic mass shift of 1 Da, providing evidence for the cyclic nature of the gas-phase Meerwein reaction products. The gas-phase Meerwein reaction offers a novel and fast LC-MS approach for the direct analysis of epoxides that might be of genotoxic concern during drug development. Understanding and utilizing this unique gas-phase ion/molecule reaction, the sensitivity and selectivity for quantitation of epoxides can be enhanced.  相似文献   

3.
Three gaseous acyclic distonic acylium ions: *CH2-CH2-C+=O, *CH2-CH2-CH2-C+=O, and *CH2=C(CH2)-C+=O, are found to display dual free radical and acylium ion reactivity; with appropriate neutrals, they react selectively either as free radicals with inert charge sites, or (and more pronouncedly) as acylium ions with inert radical sites. The free radical reactivity of the ions is demonstrated via the Kenttamaa reaction: CH3S* abstraction with the spin trap dimethyl disulfide; their ion reactivity by two reactions most characteristic of acylium ions: transacetalization with 2-methyl-1,3-dioxolane and the gas-phase Meerwein reaction, that is, expansion of the three-membered epoxide ring of epichlorohydrin to the five-membered 1,3-dioxolanylium ion ring. In "one-pot" reactions with gaseous mixtures of epichlorohydrin and dimethyl disulfide, the ions react selectively at either site, but more readily at the acylium charge site, to form the two mono-derivatized ions. Further reaction at either the remaining free radical or acylium charge site forms a single bi-derivatized ion as the final product. Becke3LYP/6-31G(d) calculations predict the reactions at the acylium charge sites of the three distonic ions to be highly exothermic, and both the "hot" transacetalization and epoxide ring expansion products of *CH2-CH2-CH2-C+=O to dissociate rapidly by H2C=CH2 loss in overall exothermic processes. The calculations also predict highly spatially separate odd spin and charge sites for the novel cyclic distonic ketal ions formed by the reactions at the acylium charge sites.  相似文献   

4.
A recently constructed miniature mass spectrometer, based on a cylindrical ion trap (CIT) mass analyzer, is used to perform ion/molecule reactions in order to improve selectivity for in situ analysis of explosives and chemical warfare agent simulants. Six different reactions are explored, including several of the Eberlin reaction type (M. N. Eberlin and R. G. Cooks, Org. Mass Spectrom., 1993, 28, 679-687) as well as novel gas-phase Meerwein reactions. The reactions include (1) Eberlin transacetalization of the benzoyl, 2,2-dimethyloximinium, and 2,2-dimethylthiooximinium cations with 2,2-dimethyl-1,3-dioxolane to form 2-phenyl-1,3-dioxolanylium cations, 2,2-dimethylamine-1,3-dioxolanylium cations and the 2,2-dimethylamin-1,3-oxathiolanylium cations, respectively; (2) Eberlin reaction of the phosphonium ion CH3P(O)OCH3+, formed from the chemical warfare agent simulant dimethyl methylphosphonate (DMMP), with 1,4-dioxane to yield the 1,3,2-dioxaphospholanium ion, a new characteristic reaction for phosphate ester detection; (3) the novel Meerwein reaction of the ion CH3P(O)OCH3+ with propylene sulfide forming 1,3,2-oxathionylphospholanium ion; (4) the Meerwein reaction of the benzoyl cation with propylene oxide and propylene sulfide to form 4-methyl-2-phenyl-1,3-dioxolane and its thio analog, respectively; (5) ketalization of the benzoyl cation with ethylene glycol to form the 2-phenyl-1,3-dioxolanylium cation; (6) addition/NO2 elimination involving benzonitrile radical cation in reaction with nitrobenzene to form an arylated nitrile, a diagnostic reaction for explosives detection and (7) simple methanol addition to the C7H7+ ion, formed by NO2 loss from the molecular ion of p-nitrotoluene to form an intact adduct. Evidence is provided that these reactions occur to give the products described and their potential analytical utility is discussed.  相似文献   

5.
A novel ion/molecule reaction was observed to occur under electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photo ionization (APPI) conditions, leading to dimerization of ionized 4‐(methyl mercapto)‐phenol followed by fast H· loss. The reaction is particularly favored during ESI, which suggests that this ion/molecule reaction can occur both in the solution inside the ESI‐charged droplets and in the gas‐phase environment of most other atmospheric pressure ionization techniques. The dimerization reaction is inherent to the electrolytic process during ESI, whereas it is more by ion/molecule chemistry in nature during APCI and APPI. From the tandem mass spectrometry (MS/MS) data, accurate mass measurements, hydrogen/deuterium (H/D) exchange experiments and density functional theory (DFT) calculations, two methyl sulfonium ions appear to be the most likely products of this electrophilic aromatic substitution reaction. The possible occurrence of this unexpected reaction complicates mass spectral data interpretation and can be misleading in terms of structural assignment as reported herein for 4‐(methyl mercapto)‐phenol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
The atmospheric pressure ionization (API) source for a commercial mass spectrometer was modified to operate as a dual source in both the electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) techniques by simultaneously utilizing the electrospray probe and the corona discharge needle. A switching box was designed to operate in either manual or programmable modes to permit rapid switching between ionization techniques without changing sources, probes, or breaking vacuum. The source can be operated using the following ionization techniques: ESI only, APCI only, ESI/APCI simultaneously, and ESI/APCI alternatingly. The optimum operating conditions for these ionization techniques were similar to the manufacturer’s original specifications except that the APCI flow rate was lower (~50 µL/min versus 1000 µL/min) and externally heated nebulizing gas was found to be desirable. A four-component mixture, introduced by flow injection, was used to demonstrate the versatility of the dual ESI/APCI source.  相似文献   

7.
Phosphonium ions are shown to undergo a gas-phase Meerwein reaction in which epoxides (or thioepoxides) undergo three-to-five-membered ring expansion to yield dioxaphospholanium (or oxathiophospholanium) ion products. When the association reaction is followed by collision-induced dissociation (CID), the oxirane (or thiirane) is eliminated, making this ion molecule reaction/CID sequence a good method of net oxygen-by-sulfur replacement in the phosphonium ions. This replacement results in a characteristic mass shift of 16 units and provides evidence for the cyclic nature of the gas-phase Meerwein product ions, while improving selectivity for phosphonium ion detection. This reaction sequence also constitutes a gas-phase route to convert phosphonium ions into their sulfur analogs. Phosphonium and related ions are important targets since they are commonly and readily formed in mass spectrometric analysis upon dissociative electron ionization of organophosphorous esters. The Meerwein reaction should provide a new and very useful method of recognizing compounds that yield these ions, which includes a number of chemical warfare agents. The Meerwein reaction proceeds by phosphonium ion addition to the sulfur or oxygen center, followed by intramolecular nucleophilic attack with ring expansion to yield the 1,3,2-dioxaphospholanium or 1,3,2-oxathiophospholanium ion. Product ion structures were investigated by CID tandem mass spectrometry (MS(2)) experiments and corroborated by DFT/HF calculations.  相似文献   

8.
The performance of the atmospheric pressure photoionization (APPI) technique was evaluated against five sets of standards and drug-like compounds and compared to atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The APPI technique was first used to analyze a set of 86 drug standards with diverse structures and polarities with a 100% detection rate. More detailed studies were then performed for another three sets of both drug standards and proprietary drug candidates. All 60 test compounds in these three sets were detected by APPI with an overall higher ionization efficiency than either APCI or ESI. Most of the non-polar compounds in these three sets were not ionized by APCI or ESI. Analysis of a final set of 201 Wyeth proprietary drug candidates by APPI, APCI and ESI provided an additional comparison of the ionization techniques. The detection rates in positive ion mode were 94% for APPI, 84% for APCI, and 84% for ESI. Combining positive and negative ion mode detection, APPI detected 98% of the compounds, while APCI and ESI detected 91%, respectively. This analysis shows that APPI is a valuable tool for day-to-day usage in a pharmaceutical company setting because it is able to successfully ionize more compounds, with greater structural diversity, than the other two ionization techniques. Consequently, APPI could be considered a more universal ionization method, and therefore has great potential in high-throughput drug discovery especially for open access liquid chromatography/mass spectrometry (LC/MS) applications.  相似文献   

9.
The applicability of three different ionization techniques: atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) was tested for the liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of five target pharmaceuticals (cyclophosphamide, methotrexate, bezafibrate, enalapril and orlistat) in wastewater samples. Performance was compared both by flow injection analysis (FIA) and on-column analysis in deionized water and wastewater samples. A column switching technique for the on-line extraction and analysis of water samples was used. For both FIA and on-column analysis, signal intensity and signal-to-noise (S/N) ratio of the target analytes in the three sources were studied. Limits of detection and matrix effects during the analysis of wastewater samples were also investigated. ESI generated significantly larger peak areas and higher S/N ratios than APCI and APPI in FIA and in on-column analysis. ESI was proved to be the most suitable ionization method as it enabled the detection of the five target compounds, whereas APCI and APPI ionized only four compounds.  相似文献   

10.
Metal salen complexes are one of the most frequently used catalysts in enantioselective organic synthesis. In the present work, we compare a series of ionization methods that can be used for the mass spectral analysis of two types of metalosalens: ionic complexes (abbreviated as Com+X?) and neutral complexes (NCom). These methods include electron ionization and field desorption (FD) which can be applied to pure samples and atmospheric pressure ionization techniques: electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) which are suitable for solutions. We found that FD is a method of choice for recording molecular ions of the complexes containing even loosely bonded ligands. The results obtained using atmospheric pressure ionization methods show that the results depend mainly on the structure of metal salen complex and the ionization method. In ESI spectra, Com+ ions were observed, while in APCI and APPI spectra both Com+ and [Com + H]+ ions are observed in the ratio depending on the structure of the metal salen complex and the solvent used in the analysis. For complexes with tetrafluoroborate counterion, an elimination of BF3 took place, and ions corresponding to complexes with fluoride counterion were observed. Experiments comparing the relative sensitivity of ESI, APCI and APPI (with and without a dopant) methods showed that for the majority of the studied complexes ESI is the most sensitive one; however, the sensitivity of APCI is usually less than two times lower and for some compounds is even higher than the sensitivity of ESI. Both methods show very high linearity of the calibration curve in a range of about 3 orders of magnitude of the sample concentration. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
系统地比较了3种常用的离子化技术电喷雾电离(ESI)、大气压化学电离(APCI)、大气压光致电离(APPI)对脂类化合物的离子化效率、检测灵敏度和覆盖范围,以探讨多重离子化液相色谱-质谱(LC-MS)方法在血清脂质组学研究中的适用性.血清样本经甲基叔丁基醚萃取后,采用Ascentiss Express C8 色谱柱(150 mm×2.1 mm, 2.7 μm)和二元线性梯度洗脱分离,流动相(A)为乙腈-水(3∶2, V/V, 含0.1%甲酸, 10 mmol/L甲酸铵),B为异丙醇-乙腈(9∶1, V/V, 含0.1%甲酸,10 mmol/L甲酸铵),分别采用ESI、APCI和APPI离子源正、负离子模式进行质谱检测.结果表明,ESI离子源对脂肪酸类、甘油脂类、甘油磷脂类化合物、鞘磷脂类化合物的离子化效率最高,对异戊烯醇脂类化合物的离子化效率与APPI离子源相当,APPI离子源对胆固醇(酯)类化合物的检测灵敏度最高,APCI离子源对各类化合物的检测灵敏度均低于ESI或APPI离子源;采用ESI和APPI离子源相结合的LC-MS脂质组学分析方法可以提高分析方法的整体灵敏度和血清中脂类信息检测的完整性.  相似文献   

12.
Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) are the two most common mass spectrometric ionization methods used in the pharmaceutical industry. However, APCI analysis can sometimes lead to ambiguity in compound characterization and quantitation due to gas-phase reactions occurring between acetonitrile and water in the plasma, and between these plasma-generated compounds and the analyte. During the analysis of various sultams and sulfonamides we observed signals corresponding to m/z [M+44](+) and [M+60](+). Various solvent conditions and collisionally activated dissociation MS(n) experiments revealed that under the high-energy plasma conditions of APCI, the acetonitrile/water solvent mixture reacts undergoing acid-catalyzed hydrolysis producing acetamide, 59 Da. Further, the highly reactive 43 Da species ethanimine is also produced. These two compounds, normally not observed in APCI analysis, are stabilized by the sulfonamide and appear as adduct species in the mass spectra. The sulfone oxygens and the lone pair of electrons on the amide nitrogen play a role in stabilizing this adduct.  相似文献   

13.
Accurate measurement of estradiol (E2) is important in clinical diagnostics and research. High sensitivity methods are critical for specimens with E2 concentrations at low picomolar levels, such as serum of men, postmenopausal women and children. Achieving the required assay performance with LC–MS is challenging due to the non‐polar structure and low proton affinity of E2. Previous studies suggest that ionization has a major role for the performance of E2 measurement, but comparisons of different ionization techniques for the analysis of clinical samples are not available. In this study, female serum and endometrium tissue samples were used to compare electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) in both polarities. APPI was found to have the most potential for E2 analysis, with a quantification limit of 1 fmol on‐column. APCI and ESI could be employed in negative polarity, although being slightly less sensitive than APPI. In the presence of biological background, ESI was found to be highly susceptible to ion suppression, while APCI and APPI were largely unaffected by the sample matrix. Irrespective of the ionization technique, background interferences were observed when using the multiple reaction monitoring transitions commonly employed for E2 (m/z 271 > 159; m/z 255 > 145). These unidentified interferences were most severe in serum samples, varied in intensity between ionization techniques and required efficient chromatographic separation in order to achieve specificity for E2. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
The fragmentation pathways of three explosive compounds with similar structures, hexanitrostilbene (HNS), cyclotrimethylene trinitramine (RDX), and 2,4,6-trinitrotoluene (TNT), have been investigated by multiple mass spectrometry (MSn, n = 1, 2, 3) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) sources. The electron capture mechanism for these compounds in negative ion APCI and ESI mode differs from the usual negative ion mechanism, deprotonation or addition of other species. This was shown for HNS and TNT, which both gave a [M]- anion but not a [M-H]- ion in APCI, and the [M]- anion of HNS was observed in ESI. The quantitative analysis of HNS was performed by liquid chromatography (LC)/ESI-MS, and the results obtained by the internal standard (ISTD) method were compared with those from the external standard (ESTD) method, demonstrating that both quantitation approaches are useful, with good sensitivity, reproducibility and linearity, and ESTD is preferable in routine applications.  相似文献   

15.
Purines and pyrimidines are of interest owing to their significance in processes in living organisms. Mass spectrometry is a promising analytical tool utilized in their analysis. Two atmospheric pressure ionization (API) methods (electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI)) in both negative and positive modes applied to selected purine and pyrimidine metabolites (markers of inherited metabolic disorders) were studied. APCI is less sensitive to alkali metal cations present in a sample and offers higher response than ESI for studied compounds. Both of the techniques afford quasi-molecular ions, but fragmentation also occurs to a certain extent. However, the application of collision-induced dissociation of quasi-molecular ions is essential to confirm a certain metabolite in a sample. Fragmentation of both positive and negative ions was evaluated using multi-stage mass spectrometric experiments. Typical neutral losses correspond to molecules NH(3), H(2)O, HCN, CO, H(2)NCN, HNCO and CO(2). The ion [NCO](-) arises in the negative mode. The cleavage of the glycosidic C-N bond is characteristic for relevant metabolites. Other neutral losses (CH(2)O, C(2)H(4)O(2) and C(3)H(6)O(3)) originate from fragmentation of the glycosidic part of the molecules. In addition to fragmentation, the formation of adducts of some ions with applied solvents (H(2)O, CH(3)OH) was observed. The composition of the solution infused into the ion source affects the appearance of the mass spectra. Tandem mass spectra allow one to distinguish compounds with the same molecular mass (uridine-pseudouridine and adenosine-2'-deoxyguanosine). Flow injection analysis APCI-MS/MS was tested on model samples of human urines corresponding to adenosine deaminase deficiency and xanthine oxidase deficiency. In both cases, the results showed potential diagnostic usefulness.  相似文献   

16.
Recent improvements in the LC-MS interface have increased the sensitivity and selectivity of this instrument in the analysis of polar and thermally-labile aqueous constituents. Determination of RDX, nitroso-RDX metabolites, and other munitions was enhanced using LC-MS with solid-phase extraction, 15N3-RDX internal standard, and electrospray ionization (ESI) in negative ion mode. ESI produced a five-fold increase in detector response over atmospheric pressure chemical ionization (APCI) for the nitramine compounds, while the more energetic APCI produced more than twenty times the ESI response for nitroaromatics. Method detection limits in ESI for nitramines varied from 0.03 microgram l-1 for MNX to 0.05 microgram l-1 for RDX.  相似文献   

17.
This paper compares two liquid introduction atmospheric pressure ionization techniques for the analysis of alkyl ethoxysulfate (AES) anionic surfactant mixtures by mass spectrometry, i. e., electrospray ionization (ESI) in both positive and negative ion modes and atmospheric pressure chemical ionization (APCI) in positive ion mode, using a triple quadrupole mass spectrometer. Two ions are observed in ESI(+) for each individual AES component, [M + Na]+ and a “desulfated” ion [M − SO3 + H]+, whereas only one ion, [M − Na] is observed for each AES component in ESI(−). APCI(+) produces a protonated, “desulfated” ion of the form [M − NaSO3 + 2H]+ for each AES species in the mixture under low cone voltage (10 V) conditions. The mass spectral ion intensities of the individual AES components in either the series from ESI(+) or APCI(+) can be used to obtain an estimate of their relative concentrations in the mixture and of the average ethoxylate (EO) number of the sample. The precursor ions produced by either ESI(+) or ESI(−), when subjected to low-energy (50 eV) collision-induced dissociation, do not fragment to give ions that provide much structural information. The protonated, desulfated ions produced by APCI(+) form fragment ions which reveal structural information about the precursor ions, including alkyl chain length and EO number, under similar conditions. APCI(+) is less susceptible to matrix effects for quantitative work than ESI(+). Thus APCI(+) provides an additional tool for the analysis of anionic surfactants such as AES, especially in complex mixtures where tandem mass spectrometry is required for the identification of the individual components.  相似文献   

18.
A new ionization method, named surface-activated chemical ionization (SACI), was employed for the analysis of five amphetamines (3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyethylamphetamine (MDE), amphetamine and methamphetamine) by ion trap mass spectrometry. The results so obtained have been compared with those achieved by using atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) using the same instrument, clearly showing that SACI is the most sensitive of the three. The limit of detection and linearity range for SACI were compared with those obtained using APCI and ESI, showing that the new SACI approach provides the best results for both criteria. SACI was used to analyze MDA, MDMA MDE, amphetamine and methamphetamine in four urine samples, and the quantitation results are compared with those achieved using ESI.  相似文献   

19.
Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) was coupled with atmospheric pressure photoionization (APPI) for the first time and used for the analysis of several corticosteroids.1 The analytes showed excellent response using APPI when compared with both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). APPI has the advantage of requiring less heat for desolvation, resulting in less thermal degradation of the analytes and higher signal-to-noise than APCI. In terms of ultimate sensitivity, APPI is more efficient than either ESI or APCI for the analysis of corticosteroids. With some compounds, the high-resolution capability of FTICRMS was necessary to obtain an accurate mass due to contributions of the M(+.) (13)C isotope in the [M+H](+) ion peak.  相似文献   

20.
The fragmentation behavior of taxoids was studied using electrospray (ESI) and atmospheric pressure chemical ionization (APCI) sources with multi-stage tandem mass spectrometry. In the positive ion mode taxoids gave prominent [M+Na]+ and [M+K]+ ions with the ESI source, and [M+NH4]+ or [M+H]+ ions with the APCI source. The MS/MS fragmentations of ions produced by APCI and ESI sources were very similar. For both sources, the presence of cinnamoyl or benzoyl groups could be characterized by initial losses of 148 or 122 u, respectively, from molecular adduct ions. However, the elimination of cinnamic acid was relatively difficult for the molecular adduct ions formed by APCI, and was comparable in importance to the loss of acetic acid. The other fragments involved losses of CH2CO, CO, and H2O. The 5/7/6 type taxoids underwent characteristic losses of 58 or 118 u from ions produced by both APCI and ESI sources. The fragmentation behavior was remarkably influenced by substitution locations. The elimination of the C-10 benzoyl group was usually the first fragmentation step, while that of the C-2 benzoyl group was relatively difficult. The acetoxyl group at C-7 was more active than those at C-2, C-9, and C-10, which in turn were more active than that at C-4. These fragmentation rules could facilitate the rapid screening and structural characterization of taxoids in plant extracts by high-performance liquid chromatography/mass spectrometry (HPLC/MS).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号