首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
林麒  李国波  葛品  许榕仙  林国斌 《色谱》2016,34(5):520-527
建立了母乳中反式脂肪酸(TFAs)的气相色谱-质谱(GC-MS)检测方法,并应用于母乳脂肪中TFAs的检测。母乳用氨水水解,乙醚和石油醚提取脂肪,提取的脂肪加入C21: 0内标,用三氟化硼甲醇溶液在80℃水浴中冷凝回流15 min进行甲酯化,正己烷提取,上清液用GC-MS分析,内标法定量。在低、中、高加标水平上验证方法的准确度与精密度,结果显示该方法可用于母乳中18种TFAs及其同分异构体的检测,其中12种TFAs在母乳脂肪中的方法检出限为4.0~47.1 mg/kg,回收率为80%~113%, RSD为2.9%~14.5%(n=6)。TFAs在部分母乳脂样品中检出,含量为9.54~6.9 mg/kg。该方法定性、定量准确,可有效用于母乳中TFAs的检测,但仍存在脂肪酸本底干扰等问题,可结合银离子固相萃取柱预分离技术进一步完善。  相似文献   

2.
A method for the assay of delta 1-tetrahydrocannabinol (delta 1-THC) in plasma using combined gas chromatography-mass spectrometry with metastable ion monitoring is described. delta 1-THC was extracted with hexane and the extracts were methylated with diazomethane to shift the peaks produced by endogenous plasma constituents away from the cannabinoid region. The delta 1-THC was then converted into its trimethylsilyl derivative and quantitated using the metastable ion at m/z 371 formed in the M+ leads to [M - CH3]+ transition with [1",1",2",2"-2H4]cannabinol as the internal standard. delta 1-THC could be measured to 5 pg/ml in plasma. This assay is 20-100 times more sensitive than existing assays and has the advantage of not needing the usual extensive purification step.  相似文献   

3.
A method for determining telenzepine in human serum is described. Analytes are obtained from alkalinized serum by extraction of the drug using reversed-phase octadecylsilane-bonded silica cartridges. Telenzepine and a desmethyl analogue added to serum as internal standard are retained on the C18 cartridge and recovered by elution with methanol. The gas chromatographic properties of telenzepine and the internal standard are improved by a two-step derivatization involving a benzodiazepinone-benzimidazole rearrangement and simultaneous formation of a methyl ester function. The processed extract is analysed by gas chromatography-mass spectrometry with selected-ion monitoring. Quantification is linear over the range 2-40 ng/ml. Inter-day precision is within 7%, except at the detection limit of 2 ng/ml (16%). Application of this assay to routine analysis is limited by the extensive sample pretreatment essential for derivatization of telenzepine.  相似文献   

4.
Lee J  Seo JH  Kim DH 《The Analyst》2002,127(7):917-920
An efficient gas chromatography-mass spectrometry (GC-MS) method was developed and validated for the determination of tizanidine in human plasma. Plasma samples were simply extracted with ethyl acetate at basic pH and the extracts were converted into trimethylsilyl (TMS) derivatives for direct separation by GC-MS with selected ion monitoring (SIM). Reaction of tizanidine with N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) caused di-trimethylsilylation in the imidazoline moiety and this silylation significantly improved the chromatographic properties of the compound. The determination of tizanidine was accurate and reproducible, with a limit of quantitation of 0.5 ng m(-1) in plasma. The calibration curve for tizanidine was linear (r2 = 0.999) over the concentration range 0.5-10.0 ng ml(-1) in human plasma. The intra- and inter-day precision over the concentration range of tizanidine was well within 6.9% (relative standard deviation) and the accuracy was between 99.2 and 110.5%.  相似文献   

5.
An automatic mass spectrometric method for the quantitation of N-acetylcysteine (NAC) in human plasma has been developed. NAC was extracted from plasma with ethyl acetate and derivatized in two steps with 2-propanol and pentafluoropropionic anhydride. The volatile derivative obtained was ideal for gas chromatographic-mass spectrometric analysis. Data obtained by analysing the plasma of healthy volunteers to whom 600 mg of NAC had been orally given are reported.  相似文献   

6.
A sensitive and efficient method was developed for the determination of atenolol in human urine by gas chromatography-mass spectrometry (GC-MS). Atenolol and metoprolol (internal standard, IS) were extracted from human urine with a mixture of chloroform and butanol at basic pH with liquid-liquid extraction. The extracts were derivatized with N-Methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) and analyzed by GC-MS using a capillary column. The standard curve was linear (r = 0.99) over the concentration range of 50-750 ng/mL. Intra- and inter-day precision, expressed as the relative standard deviation were less than 5.0%, and accuracy (relative error) was better than 7.0%. The analytical recovery of atenolol from human urine has averaged 91%. The limit of quantification was 50 ng/mL. Also, the method was successfully applied to a patient with hypertension who had been given an oral tablet of 50 mg atenolol.  相似文献   

7.
A gas chromatographic-mass spectrometric method was developed to determine eperisone hydrochloride, 4'-ethyl-2-methyl-3-piperidinopropiophenone hydrochloride, in human plasma over the concentration range 0.2-40 ng/ml. Excellent sensitivity was achieved by selection of a favorable fragment ion, m/z 98, of eperisone and reduction of heat decomposition of eperisone by using a splitless injector and a shortened capillary column. The method described here allows the determination of plasma concentrations as low as 0.2 ng/ml, the concentration attained 6 h after a single oral administration of 50 mg. At eperisone hydrochloride concentrations higher than 0.5 ng/ml, the mean inter-day variation of accuracy of the assay was less than 12%.  相似文献   

8.
A specific, sensitive and accurate quantitative analysis of testosterone propionate in human plasma was developed using gas chromatography-mass spectrometry-selected-ion monitoring. For the calculation of testosterone propionate in plasma, peak height ratios were measured by selected-ion monitoring performed on the molecular ions of the trifluoroacetyl derivative of testosterone propionate (m/z 440) and testosterone propionate-19,19,19-d3 (m/z 443). The sensitivity of the method was judged from the lower limit of the detection of the mass spectrometer which was at 20 pg. The inter-assay coefficients of variation and relative error at a concentration of 1.31 ng/ml of plasma were 5.47% and -2.3%, respectively. The method described was applied to the determination of plasma concentrations of testosterone propionate-19,19,19-d3 following an intramuscular dose of testosterone propionate-19,19,19-d3 in a healthy male volunteer.  相似文献   

9.
10.
A rapid analytical method has been developed for the determination of polybrominated diphenyl ethers (PBDEs) in human hair. PBDEs were determined by gas chromatography with electron ionization mass spectrometric detection in the selected ion monitoring mode (GC-MS-SIM). A 200 mg amount of hair samples was overnight digested in 3N HCl and then PBDEs extracted with n-hexane. After clean up of extracts in a Florisil column, PBDEs were analyzed by GC-MS. The method has been validated by spiking human hair at five concentration levels, in the range from 5 to 25 ng/g for most compounds, and PBDEs were quantified using labelled compounds as internal standards. Recoveries of PBDEs were higher than 90%, repeatability was equal or lower than 12.5%, and reproducibility lower than 14%, expressed as relative standard deviation (RSD). Limits of detection (LOD) were in the range 0.08-0.9 ng/g and limits of quantification (LOQ) were between 0.27 and 3.0 ng/g. This method was applied to the determination of PBDEs in hair samples from 16 individuals and 5 PBDE congeners were detected in most of the samples. BDE-209 was the dominant compound found, followed by BDE-47, BDE-99, BDE-100, and BDE-190. BDE-209 was found in 12 out of 16 hair samples, and the total levels of PBDEs ranged from 1.4 to 19.9 ng/g.  相似文献   

11.
Summary An analytical method for the simultaneous determination of the pyrethroid metabolites cis and trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane carboxylic acid, cis 3-(2,2-dibromovinyl)-2,2-dimethylcyclopropane carboxylic acid, 3-phenoxybenzoic acid and 4-fluoro-3-phenoxybenzoic acid in human urine samples is described. The urine is subjected to acid-induced hydrolysis followed by exhaustive solvent extraction, covering both conjugated and free acids, followed by a common derivatisation step yielding the corresponding methyl esters. Quantitation was by diastereomeric, capillary gas chromatography-mass spectrometry. It appears that 4-fluoro-3-phenoxybenzoic acid is a characteristic urinary marker for cyfluthrin exposure. The limits of determination are 0.5–1.0 g L–1 urine depending on the metabolites concerned. The applicability of the method was tested on urine samples from pest control operators exposed occupationally to cypermethrin and cyfluthrin.  相似文献   

12.
This work describes a sensitive method for determining cholesterol in human hair using GC-MS. In this study, we used a very small amount of hair, only 1 mg, to quantify cholesterol. We also can achieve more effective purification and a good recovery over 92% with solid-phase extraction using an Oasis HLB cartridge. The intra-day and inter-day precision and accuracy values were less than 7.08%. Cholesterol was determined to be in the range of 355-1693 microg/g in healthy human hair. We tested the concentration correlation between the serum and hair to examine the feasibility of using the hair cholesterol level as an index of the serum cholesterol level. The correlation between the serum cholesterol was 0.86 (r-value) in patients with hypercholesterolemia. This finding indicates that, in the clinical field, hair could replace serum in cholesterol level measurement.  相似文献   

13.
GC-MS直接测定芥酸酰胺   总被引:2,自引:0,他引:2  
通常衍生后的酰胺才能用气相色谱测定.在实验几种酰胺衍生化方法时发现衍生反应不彻底剩余的芥酸酰胺也能出峰.进一步实验表明:芥酸酰胺在295 ℃气化后可直接测定,该法以邻苯二甲酸二丁酯为内标,质量浓度在115.4~923.2 mg/L 范围内线性关系良好,样品回收率94.85%~98.04%,芥酸酰胺的检出限5.77 mg/L.  相似文献   

14.
The application of the recently introduced ethylchloroformate derivatization method for the separation and determination of selenomethionine and selenocystein in selenium-enriched yeast and yeast-free tablets by means of a gas chromatography-mass spectrometry (GC-MS) system has been studied. The efficiency of three methods for the extraction of selenomethionine from the tablets were compared. Total selenium content of the same tablets were measured using inductively coupled plasma (ICP)-MS and it was found that in the selenized yeast tablets about 80% of the total selenium is present as selenomethionine. The results were in agreement with the values in the labels and with the literature. The accuracy of the total selenium analysis was controlled by the analysis of a reference material.  相似文献   

15.
建立了测定化妆品中三氯叔丁醇的气相色谱-质谱分析方法.膏霜、水剂、散粉、香波、唇膏等不同类型的化妆品样品加入50%甲醇-无水乙醇或无水乙醇超声提取后,样品提取液高速离心处理,取上清液经无水硫酸钠脱水,进行气相色谱-质谱定性及定量分析.选用DB-1701(30 m×0.25 mm×0.25μm)石英毛细管柱,程序升温,流...  相似文献   

16.
气相色谱-质谱法测定水中痕量的四乙基铅   总被引:4,自引:0,他引:4  
杨丽莉  王美飞  李娟  胡恩宇 《色谱》2010,28(10):993-996
建立了气相色谱-质谱(GC-MS)测定水中痕量四乙基铅的分析方法。用正己烷萃取水样中的四乙基铅,萃取液浓缩后加入同位素内标萘-d8,采用GC-MS选择离子方式(SIM)进行检测,在200 mL水样中四乙基铅的检出限可达0.04 μg/L;添加回收率为92.2%~103%,准确度好;平行5次测定的相对标准差为4.4%~13.3%。结果表明: 方法简便、快速、准确、实用,可用于水中痕量四乙基铅的测定。  相似文献   

17.
建立了防火涂料中阻燃剂六溴环十二烷(HBCD)的气相色谱-质谱(GC-MS)分析方法。样品用二氯甲烷进行萃取,萃取液经有机滤膜过滤后,用气相色谱-质谱联用仪进行测定。在选择离子检测模式下以m/z 157、239、319、401为定性离子,m/z 239为定量离子进行结构确证和定量检测。在优化的实验条件下,六溴环十二烷标准溶液在5~100 mg/L的质量浓度范围内线性关系良好,相关系数大于0.999。对市售的空白丙烯酸树脂涂料样品及环氧树脂涂料样品进行加标回收试验,结果表明本方法的平均回收率为92.9%~116.3%, RSD不超过8%。方法的检出限(S/N=3)为30 μg/g,定量限(S/N=10)为100 μg/g。本方法简便、快速、准确性好、精密度高,能够满足检测工作的实际要求。  相似文献   

18.
蜂蜜中氯霉素残留的气质分析方法研究   总被引:1,自引:0,他引:1  
氯霉素(chloramphenicol)又名左旋霉素,是一类广谱抗生素,作为药物常用于家禽疾病治疗和预防.氯霉素对人的造血系统、消化系统具有严重的毒性反应,有可能引发人的再生障碍性贫血.因此欧盟等国家规定蜂蜜及其它动物源食品中氯霉素的最高残留量不得超过0.1μg/kg.本文对蜂蜜样品的提取、净化和富集方法进行了较为系统地研究,建立了固相萃取-气相色谱-质谱联机分析蜂蜜中的氯霉素残留量的方法.对氯霉素在固相萃取柱上的保留行为进行了研究,优化固相萃取条件,发现在选定的条件下,不同浓度的氯霉素在硅胶柱和C18柱上的回收率均在90%以上,蜂蜜加标的回收率在80%~95%,相对标准偏差在7.2%~18.2%,最低检出限为0.1μg/kg.对氯霉素的三甲基硅烷化衍生物采用选择离子的模式进行检测(376,378,466、468、470),衍生物的峰面积与样品浓度在0.55~220 ng/mL范围内呈良好的线性关系,线性回归系数为0.9998.  相似文献   

19.
A procedure is described for the quantitative determination of zopiclone and the sum of its metabolites in urine using gas chromatography with the mass-spectrometric detection of their common hydrolysis product, 6-(5-chloro-2-pyridyl)-7-hydroxy-6,7-dihydro-5H-pyrrolo[3,4-b]pyrazine-5-on. The procedure is very sensitive. The detection limit for ions with a mass of 45–450 au detected in the full scanning mode is 70 ng/mL. The data of gas chromatography-mass spectrometry are presented for different derivatives of the hydrolysis product of zopiclone; these data can be used for the qualitative identification of zopiclone. The stability of zopiclone and its metabolites upon time was studied by analyzing urine samples from patients receiving therapeutic doses of this substance stored for 1, 3, and 6 months.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号