首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Flat H-terminated Si(111) substrates modified with alkyl monolayers terminated with hydrophobic and hydrophilic functional groups were prepared using known surface functionalization methods and characterized by FTIR, X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The surfaces were then used for the study of non-specific binding of proteins from complex mixtures (using standard mixture of proteins with average molecular weight approximately 6-66 kDa) by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Protein adsorption on these surfaces (following on-probe fractionation of the mixture) was found to be dependent on the nature of surface functional groups, and nature and pH of rinsing solutions used. The results obtained in this work demonstrate that simple silicon-based surface modifications can be effective for direct analysis of complex mixtures by MALDI-MS. Preliminary results obtained using similarly functionalized porous silicon substrates proved that such substrates are (due to their increased surface areas) better performing than flat silicon.  相似文献   

2.
Cheng YC  Chen KH  Wang JS  Hsu WL  Chien CC  Chen WY  Tsao CW 《The Analyst》2012,137(3):654-661
This study developed a rapid, sensitive, and matrix-free method for the determination of amphetamine (AMP), methamphetamine (MA), codeine (COD), morphine (MOR), and ketamine (KET) using nanostructured silicon surface assisted laser desorption/ionization mass spectrometry (nSi-MS). The nanostructured silicon (nSi) chip used in this study was created by employing the metal-assisted etching process. Drug standard tests were applied to the nSi chip platform to evaluate the nSi-MS performance, including detection sensitivity, limit of detection, linearity, and repeatability. Real urine samples obtained from drug addict detainees were directly applied to the nSi chip for drug analysis. By observing the nSi-MS spectra, the target drug peaks can be identified; and an antibody pull-down assay was performed to confirm the specificity of the detected targets. nSi-MS drug quantification was assayed, yielding comparable results with those from using the GC-MS approach. The advantages of applying nSi-MS to analyze AMP, MA, COD, MOR, and KET in the urine of addicts are simple, extremely small urine volumes (~10 μL), and a fast analysis procedure (<15 minutes).  相似文献   

3.
A matrix-free, high sensitivity, nanostructured silicon surface assisted laser desorption/ionization mass spectrometry (LDI-MS) method fabricated by metal-assisted etching was investigated. Effects of key process parameters, such as etching time, substrate resistance and etchant composition, on the nanostructured silicon formation and its LDI-MS efficiency were studied. The results show that the nanostructured silicon pore depth and size increase with etching time, while MS ion intensity increases with etching time to 300 s then decreases until 600 s for both low resistance (0.001–0.02 Ω cm) and high resistance (1–100 Ω cm) silicon substrates. The nanostructured silicon surface morphologies were found to directly affect the LDI-MS signal ion intensity. By characterizing the nanostructured silicon surface roughness using atomic force microscopy (AFM) and sample absorption efficiency using fluorescence microscopy, it was further demonstrated that the nanostructured silicon surface roughness was highly correlated to the LDI-MS performance.  相似文献   

4.
Nanoparticle assisted laser desorption/ionization mass spectrometry (NPs-ALDI-MS) shows remarkable characteristics and has a promising future in terms of real sample analysis. The incorporation of NPs can advance several methods including surface assisted LDI-MS, and surface enhanced LDI-MS. These methods have advanced the detection of many thermally labile and nonvolatile biomolecules. Nanoparticles circumvent the drawbacks of conventional organic matrices for the analysis of small molecules. In most cases, NPs offer a clear background without interfering peaks, absence of fragmentation of thermally labile molecules, and allow the ionization of species with weak noncovalent interactions. Furthermore, an enhancement in sensitivity and selectivity can be achieved. NPs enable straightforward analysis of target species in a complex sample. This review (with 239 refs.) covers the progress made in laser-based mass spectrometry in combination with the use of metallic NPs (such as AuNPs, AgNPs, PtNPs, and PdNPs), NPs consisting of oxides and chalcogenides, silicon-based NPs, carbon-based nanomaterials, quantum dots, and metal-organic frameworks.
Graphical abstract An overview is given on nanomaterials for use in surface-assisted laser desorption/ionization mass spectrometry of small molecules.
  相似文献   

5.
Various types of ionization of organotellurium compounds in mass-spectrometric study are considered, with diphenyl telluroxide as example. The mass spectra of diphenyl telluroxide are presented. The possibility of applying surface-activated and matrix-assisted laser desorption/ionization mass spectrometry to organotellurium compounds is examined.  相似文献   

6.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is a powerful tool for the measurement of low molecular mass compounds of biological interest. The limitations for this method are the volatility of many analytes, possible interference with matrix signals or bad ionization or desorption behavior of the compounds. We investigated the application of well-known and straightforward one-pot derivatization procedures to circumvent these problems. The derivatizations tested allow the measurement and the labeling of alcohols, aldehydes and ketones, carboxylic acids, alpha-ketocarboxylic acids and amines.  相似文献   

7.
Desorption/ionization on silicon (DIOS) mass spectra of model ionic dyes methylene blue (MB+Cl?) and methyl orange (Na+MO?) were studied using p+ type‐derived porous silicon (PS) free layers. As‐prepared PS (PS‐H), the PS thermally oxidized at 300 °C (PS‐OX), PS with chemically grafted cation‐exchanging alkylsulfonic acid (PS‐SO3H) and anion‐exchanging propyl‐octadecyldimethylammonium chloride (PS‐ODMA+Cl?) groups was tested as ionization platforms. Two mechanisms of the methylene blue desorption/ionization were found: (1) the formation of [MB + H]+? ion due to the reduction/protonation of MB+, which is predominant for PS‐H and PS‐OX platforms and (2) direct thermal desorption of the MB+ cation, prevailing for PS‐SO3H. The fragmentation of the cation is significantly suppressed in the latter case. The samples of PS‐SO3H and PS‐ODMA+ Cl? efficiently adsorb the dyes of the opposite charge from their solutions via the ion‐exchange. Consequent DIOS MS studies allow to detect only low fragmented ions (MB+ and MO?, respectively), demonstrating the potential of the ion‐exchange adsorption combined with DIOS MS for the analysis of ionic organic compounds in solutions. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
Chemically modified silicon nanoparticles were applied for the laser desorption/negative ionization of small acids. A series of substituted sulfonic acids and fatty acids was studied. Compared to desorption ionization on porous silicon (DIOS) and other matrix-less laser desorption/ionization techniques, silicon nanoparticle-assisted laser desorption/ionization (SPALDI) mass spectrometry allows for the analysis of acids in the negative ion mode without the observation of multimers or cation adducts. Using SPALDI, detection limits of many acids reached levels down to 50 pmol/μl. SPALDI of fatty acids with unmodified silicon nanoparticles was compared to SPALDI using the fluoroalkyl silylated silicon powder, with the unmodified particles showing better sensitivity for fatty acids, but with more low-mass background due to impurities and surfactants in the untreated silicon powder. The fatty acids exhibited a size-dependent response in both SPALDI and unmodified SPALDI, showing a signal intensity increase with the chain length of the fatty acids (C12-C18), leveling off at chain lengths of C18-C22. The size effect may be due to the crystallization of long chain fatty acids on the silicon. This hypothesis was further explored and supported by SPALDI of several, similar sized, unsaturated fatty acids with various crystallinities. Fatty acids in milk lipids and tick nymph samples were directly detected and their concentration ratios were determined by SPALDI mass spectrometry without complicated and time-consuming purification and esterification required in the traditional analysis of fatty acids by gas chromatography (GC). These results suggest that SPALDI mass spectrometry has the potential application in fast screening for small acids in crude samples with minimal sample preparation.  相似文献   

9.
A variety of surfactants have been tested as matrix-ion suppressors for the analysis of small molecules by matrix-assisted laser desorption/ionization time-of flight mass spectrometry. Their addition to the common matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) greatly reduces the presence of matrix-related ions when added at the appropriate mole ratio of CHCA/surfactant, while still allowing the analyte signal to be observed. A range of cationic quaternary ammonium surfactants, as well as a neutral and anionic surfactant, was tested for the analysis of phenolics, phenolic acids, peptides and caffeine. It was found that the cationic surfactants, particularly cetyltrimethylammonium bromide (CTAB), were suitable for the analysis of acidic analytes. The anionic surfactant, sodium dodecyl sulfate, showed promise for peptide analysis. For trialanine, the detection limit was observed to be in the 100 femtomole range. The final matrix/surfactant mole ratio was a critical parameter for matrix ion suppression and resulting intensity of analyte signal. It was also found that the mass resolution of analytes was improved by 25-75%. Depth profiling of sample spots, by varying the number of laser shots, revealed that the surfactants tend to migrate toward the top of the droplet during crystallization, and that it is likely that the analyte is also enriched in this surface region. Here, higher analyte/surfactant concentration would reduce matrix-matrix interactions (known to be a source of matrix-derived ions).  相似文献   

10.
Tetrathiofulvalene compounds are important components of charge-transfer complexes, which may be applied in various fields of scientific research and practical applications. Some of these compounds cannot be characterized by mass spectrometry. Here, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry was used for the characterization of tetrathiofulvalenes. The samples could be easily desorbed and ionized to form singly charged ions, and mass spectra with isotopic resolution readily obtained. The mass spectrometric results for 26 compounds have shown that MALDI-TOF is more effective and convenient than other mass spectrometry methods, and resolves the problem of mass spectrometric characterization of tetrathiofulvalene compounds.  相似文献   

11.
Tsao CW  Lin CH  Cheng YC  Chien CC  Chang CC  Chen WY 《The Analyst》2012,137(11):2643-2650
Matrix-assisted laser desorption/ionization mass spectrometry is an established soft ionization method that is widely applied to analyze biomolecules. The UV-absorbing organic matrix is essential for biomolecule ionization; however, it also creates matrix background interference, which results in problematic analyses of biomolecules of less than 700 Da. Therefore, this study investigates hydrophilic, hydrophobic cationic, anionic and immobilized metal ion surface chemical modifications to advance nanostructured silicon mass spectrometry performance (nSi-MS). This investigation provides information required for a possible novel mass spectroscopy that combines surface-enhanced and nanostructured silicon surface-assisted laser desorption/ionization mass spectrometry for the selective detection of specific compounds of a mixture.  相似文献   

12.
Taxanes are biologically active compounds that have been extensively used in pharmacology for their powerful anticancer properties. High specificity and low level sensitivity for analysis of these compounds have been obtained with reversed-phase high-pressure liquid chromatography/mass spectrometry (RP-HPLC/MS), but the number of applications of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) for low molecular weight analytes is rapidly growing. A new MALDI-MS approach for the rapid screening of a variety of taxanes and a tandem mass spectrometric (MS/MS) analysis of the most important and diagnostic taxane fragmentation pathways are proposed. A solid-phase extraction method followed by preliminary quantification is also reported.  相似文献   

13.
Cysteine sulfonic acid-containing peptides, being typical acidic peptides, exhibit low response in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. In this study, matrix conditions and the effect of diammonium hydrogencitrate (DAHC) as additive were investigated for ionization of cysteine sulfonic acid-containing peptides in MALDI. A matrix-free ionization method, desorption/ionization on porous silicon (DIOS), was also utilized to evaluate the effect of DAHC. When equimolar three-component mixtures of peptides carrying free cysteine, cysteine sulfonic acid, and carbamidomethyl cysteine were measured by MALDI using a common matrix, alpha-cyano-4-hydroxycinnamic acid (CHCA), no signal corresponding to cysteine sulfonic acid-containing peptide could be observed in the mass spectrum. However, by addition of DAHC to CHCA, the peaks of cysteine sulfonic acid-containing peptides were successfully observed, as well as when using 2,4,6-trihydroxyacetophenone (THAP) and 2,6-dihydroxyacetophenone with DAHC. In the DIOS mass spectra of these analytes, the use of DAHC also enhanced the peak intensity of the cysteine sulfonic acid-containing peptides. On the basis of studies with these model peptides, tryptic digests of oxidized peroxiredoxin 6 were examined as a complex peptide mixture by MALDI and DIOS. In MALDI, the peaks of cysteine sulfonic acid-containing peptides were observed when using THAP/DAHC as the matrix, but this was not so with CHCA. In DIOS, the signal from cysteine sulfonic acid-containing peptides was suppressed; however, the use of DAHC significantly enhanced the signal intensity with an increase in the number of observed peptides and increased signal-to-noise ratio in the DIOS spectra. The results show that DAHC in the matrix or on the DIOS chip decreases discrimination and suppression effects in addition to suppressing alkali-adduct ions, which leads to a beneficial effect on protonation of peptides containing cysteine sulfonic acid.  相似文献   

14.
Measurement and identification of digested peptides by matrix-assisted laser desorption and ionization mass spectrometry (LDI-MS) is demonstrated. Synthetic human parathyroid hormone, pTH (1-34), with a molecular mass of 4117.8 Da was digested with carboxypeptidases Y and B and the sequence of 14 amino acids from the C-terminus of the peptide was determined by analyzing the molecular mass of the truncated peptides. Furthermore, a tryptic digestion of pTH (1-34) was carried out and a molecular mass map of pTH (1-34) was obtained. With the results of the proteolytic digestion a rapid confirmation of the amino-acid sequence of the protein was possible. It is shown that the results of the tryptic digestion can be used for the unambiguous identification of the amino acid residues Lys and Arg, which cannot be distinguished with a mass spectrometer because of their equal nominal masses. Several advantages of amino acid sequence determination by the combination of digestion and LDI-MS are obvious: high sensitivity in the low pmol range, fast digestion time due to high enzyme/substrate ratios, quantification is unnecessary because the amino acids are identified by their molecular mass differences, the low chemical expenditure for the digestions and the accuracy of the sequence determination. Measurements with LDI-MS are fast: sample preparation and the measurement take only a few min. The mass determination and amino acid sequence is completely unimpaired by amino acid contaminations or impurities in the sample. The sensitivity of the method is in the low pmol to fmol range and thus comparable to other analytical methods.  相似文献   

15.
A new photocleavable molecule for laser desorption ionization mass spectrometry (LDI-MS) was designed and synthesized. The molecule exhibited high sensitivity for negative mode MS detection with good chemical stability. The molecule was successfully applied to molecular tag for (LDI-MS). Kinetic measurement of the amidation reaction and monitoring of aminolysis of acetylated sugars were demonstrated with the molecular tag.  相似文献   

16.
Porous poly(butyl methacrylate-co-ethylene dimethacrylate), poly(benzyl methacrylate-co-ethylene dimethacrylate), and poly(styrene-co-divinylbenzene) monoliths have been prepared on the top of standard sample plates used for matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry and the modified plates were used for laser desorption/ionization mass spectrometry (LDI-MS). The hydrophobic porous surface of these monoliths enables the transfer of sufficient energy to the analyte to induce desorption and ionization prior to TOFMS analysis. Both UV and thermally initiated polymerization using a mask or circular openings in a thin gasket have been used to define spot locations matching those of the MALDI plates. The desorption/ionization ability of the monolithic materials depends on the applied laser power, the solvent used for sample preparation, and the pore size of the monoliths. The monolithic matrices are very stable and can be used even after long storage times in a typical laboratory environment without observing any deterioration of their properties. The performance of the monolithic material is demonstrated with the mass analysis of several small molecules including drugs, explosives, and acid labile compounds. The macroporous spots also enable the archiving of samples.  相似文献   

17.
Matrix-assisted laser desorption ionization is a recently developed new ionization technique which enables macromolecular compounds to be investigated by mass spectrometry. The general features of the technique are described, they have so far mainly been worked out for biopolymers such as proteins. Fast and precise molecular weight determination is possible up to 400,000 Dalton. First examples described in this paper indicate that the technique also holds great promise for the investigation of synthetic polymers.  相似文献   

18.
An automated sample preparation for high throughput accurate mass determinations by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been developed. Sample preparation was performed with an automated workstation and automated mass analyses were performed with a commercial MALDI-TOF mass spectrometer. The method was tested with a 41-sample library. MALDI-TOFMS was found to give the needed sensitivity, accurate mass measurement, and soft ionization necessary for structure confirmation, even of mixtures. A mass accuracy of 5 ppm or less was obtained in over 80% of known compound measurements. A mass accuracy better than 10 ppm was obtained for all measurements of known compounds. Analyses of parallel synthesis products resulted in 77% of the measurements with a mass accuracy of 5 ppm or better.  相似文献   

19.
This report focuses on the heterogeneous distribution of small molecules (e.g. metabolites) within dry deposits of suspensions and solutions of inorganic and organic compounds with implications for chemical analysis of small molecules by laser desorption/ionization (LDI) mass spectrometry (MS). Taking advantage of the imaging capabilities of a modern mass spectrometer, we have investigated the occurrence of “coffee rings” in matrix-assisted laser desorption/ionization (MALDI) and surface-assisted laser desorption/ionization (SALDI) sample spots. It is seen that the “coffee-ring effect” in MALDI/SALDI samples can be both beneficial and disadvantageous. For example, formation of the coffee rings gives rise to heterogeneous distribution of analytes and matrices, thus compromising analytical performance and reproducibility of the mass spectrometric analysis. On the other hand, the coffee-ring effect can also be advantageous because it enables partial separation of analytes from some of the interfering molecules present in the sample. We report a “hidden coffee-ring effect” where under certain conditions the sample/matrix deposit appears relatively homogeneous when inspected by optical microscopy. Even in such cases, hidden coffee rings can still be found by implementing the MALDI-MS imaging technique. We have also found that to some extent, the coffee-ring effect can be suppressed during SALDI sample preparation.  相似文献   

20.
Porous silicon powder and silica gel particles have been applied as inorganic matrices for the analysis of small molecules in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOFMS). In contrast to conventional MALDI-TOFMS, the signal interference of low-molecular analytes by the matrix has been eliminated. Almost no fragmentations of the analytes were observed. Effects of various factors, such as the particle and pore size, the suspending solution, and sample preparation procedures, on the intensity of mass spectra have been investigated. The pore structure of the inorganic matrix and penetration of the analytes into the pores must be optimized for effective desorption and ionization of the analytes. Matrices (DHB and HCCA) were covalently bound to silica gel for improvement of spectrum intensity. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号