首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(15):2761-2762
Abstract

The present note deals with the optimization of the combustion of organic materials to CO2 in Pyrex and quartz tubes. The influence of temperature and oxidant on the combustion yield was investigated. Different physical forms of CuO and a CuO/MnO2-mixture were used as oxidants. Possible isotopic effects during combustion were tested by gas isotope ratio mass spectrometry (GIRMS) of the CO2. Excellent results were obtained for combustion in Pyrex at 530 °C using CuO rods mixed with 20% MnO2 as oxidant. The stable isotope results for CO2 prepared with this method were accurate and showed a very good precision of 0.030 %. Applications for which quantitative combustion is a necessity, we suggest the use of CuO powder (< 100 μm) as oxidant and a combustion temperature of 850 °C.  相似文献   

2.
Oxygen isotope values of biogenic apatite have long demonstrated considerable promise for paleothermometry potential because of the abundance of material in the fossil record and greater resistance of apatite to diagenesis compared to carbonate. Unfortunately, this promise has not been fully realized because of relatively poor precision of isotopic measurements, and exceedingly small size of some substrates for analysis. Building on previous work, we demonstrate that it is possible to improve precision of δ18OPO4 measurements using a ‘reverse‐plumbed’ thermal conversion elemental analyzer (TC/EA) coupled to a continuous flow isotope ratio mass spectrometer (CF‐IRMS) via a helium stream [Correction made here after initial online publication]. This modification to the flow of helium through the TC/EA, and careful location of the packing of glassy carbon fragments relative to the hot spot in the reactor, leads to narrower, more symmetrically distributed CO elution peaks with diminished tailing. In addition, we describe our apatite purification chemistry that uses nitric acid and cation exchange resin. Purification chemistry is optimized for processing small samples, minimizing isotopic fractionation of PO4?3 and permitting Ca, Sr and Nd to be eluted and purified further for the measurement of δ44Ca and 87Sr/86Sr in modern biogenic apatite and 143Nd/144Nd in fossil apatite. Our methodology yields an external precision of ± 0.15‰ (1σ) for δ18OPO4. The uncertainty is related to the preparation of the Ag3PO4 salt, conversion to CO gas in a reversed‐plumbed TC/EA, analysis of oxygen isotopes using a CF‐IRMS, and uncertainty in constructing calibration lines that convert raw δ18O data to the VSMOW scale. Matrix matching of samples and standards for the purpose of calibration to the VSMOW scale was determined to be unnecessary. Our method requires only slightly modified equipment that is widely available. This fact, and the demonstrated improvement in precision, should help to make apatite paleothermometry far more accessible to paleoclimate researchers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
High-frequency throughput is often needed in isotopic studies in biological and medical fields. Here we report that high-precision oxygen isotope ratio measurements of water (+/-0.13 per thousand) were rapidly and routinely made on small samples (40-100 microL) using an isotope ratio mass spectrometer operated in continuous-flow mode. Simple modifications to existing instrumentation allow for rapid manual analyses of dilute CO2 (10% CO2/90% N2), including the addition of a septum port and water trap prior to the gas chromatography (GC) column (elemental analyzer column in this study) and the extension of fused-silica capillary tubing between the mass spectrometer source and the effluent tubing from the GC column (located within the CONFLO unit on Finnigan mass spectrometers). We routinely analyzed 20 small-volume samples per hour using this technique, without sacrificing precision of the oxygen isotope ratio measurement.  相似文献   

4.
A new analytical method is presented for the compound-specific carbon and nitrogen isotope ratio analysis of a thermo-labile nitramine explosive hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) by gas chromatograph coupled to an isotope ratio mass spectrometer (GC-IRMS). Two main approaches were used to minimise thermal decomposition of the compound during gas chromatographic separation: programmed temperature vaporisation (PTV) as an injection technique and a high-temperature ramp rate during the GC run. δ15N and δ13C values of RDX measured by GC-IRMS and elemental analyser (EA)-IRMS were in good agreement within a standard deviation of 0.3‰ and 0.4‰ for nitrogen and carbon, respectively. Application of the method for the isotope analysis of RDX during alkaline hydrolysis at 50°C revealed isotope fractionation factors ε carbon?=??7.8‰ and ε nitrogen?=??5.3‰.  相似文献   

5.
张越强  易洪  张敬畅  易未 《分析化学》2011,39(2):293-294
1引言在自然界中,硅元素有3种稳定同位素28Si,29Si和30Si,丰度分别为92.23%,3.68%和3.09%。准确测量硅的摩尔质量,需准确测量硅的3种同位素的丰度值。目前,测量硅摩尔质量最佳的方法是采用SiF4气体测定硅同位素的丰度值,这  相似文献   

6.
The determination of the oxygen isotope composition of diatom silica in sediment cores is important for paleoclimate reconstruction, especially in non‐carbonate sediments, where no other bioindicators such as ostracods and foraminifera are available. Since most currently available analytical techniques are time‐consuming and labour‐intensive, we have developed a new, safer, faster and semi‐automated online approach for measuring oxygen isotopes in biogenic silica. Improvements include software that controls the measurement procedures and a video camera that remotely records the reaction of the samples under BrF5 with a CO2 laser. Maximum safety is guaranteed as the laser‐fluorination unit is arranged under a fume hood in a separate room from the operator. A new routine has been developed for removing the exchangeable hydrous components within biogenic silica using ramp degassing. The sample plate is heated up to 1100°C and cooled down to 400°C in ~7 h under a flow of He gas (the inert Gas Flow Dehydration method – iGFD) before isotope analysis. Two quartz and two biogenic silica samples (~1.5 mg) of known isotope composition were tested. The isotopic compositions were reproducible within an acceptable error; quartz samples gave a mean standard deviation of <0.15‰ (1σ) and for biogenic silica <0.25‰ (1σ) for samples down to ~0.3 mg. The semi‐automated fluorination line is the fastest method available at present and enables a throughput of 74 samples/week. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
胡灿  梅宏成  郭洪玲  孙振文  刘占芳  朱军 《色谱》2021,39(4):376-383
炸药的深度比对与溯源对于爆炸案事件的侦破具有重大意义,以不同地域来源的原料或不同生产工艺生产的炸药,其组成元素的稳定同位素比值具有差异,因而稳定同位素比值可作为炸药深度比对与溯源的重要指标.稳定同位素比值质谱法(IRMS)作为一种高精度的稳定同位素比值测量手段,已逐渐发展成熟,与元素分析仪、气相色谱仪、液相色谱仪等仪器...  相似文献   

8.
A mass spectrometric method to determine the absolute intramolecular (position-dependent) nitrogen isotope ratios of nitrous oxide (N2O) has been developed. It is based on the addition of different amounts of doubly labeled 15N2O to an N2O sample of the isotope ratio mass spectrometer reference gas, and subsequent measurement of the relative ion current ratios of species with mass 30, 31, 44, 45, and 46. All relevant quantities are measured by isotope ratio mass spectrometers, which means that the machines inherent high precision of the order of 10–5 can be fully exploited. External determination of dilution factors with generally lower precision is avoided. The method itself can be implemented within a day, but a calibration of the oxygen and average nitrogen isotope ratios relative to a primary isotopic reference material of known absolute isotopic composition has to be performed separately. The underlying theoretical framework is explored in depth. The effect of interferences due to 14N15N16O and 15N14N16O in the 15N2O sample and due to 15N 2 + formation are fully accounted for in the calculation of the final position-dependent nitrogen isotope ratios. Considering all known statistical uncertainties of measured quantities and absolute isotope ratios of primary isotopic reference materials, we achieve an overall uncertainty of 0.9 (1). Using tropospheric N2O as common reference point for intercomparison purposes, we find a substantially higher relative enrichment of 15N at the central nitrogen atom over 15N at the terminal nitrogen atom than measured previously for tropospheric N2O based on a chemical conversion method: 46.3±1.4 as opposed to 18.7±2.2. However, our method depends critically on the absolute isotope ratios of the primary isotopic reference materials air–N2 and VSMOW. If they are systematically wrong, our estimates will also necessarily be incorrect.  相似文献   

9.
Secondary ion mass spectrometry (SIMS) measurement of oxygen isotopes in apatite has been employed more and more in petrogenetic, metallogenic, and climate change studies. Well-characterised reference materials are needed due to the matrix effect, but they are yet to be well established. In this study, we conducted in-situ oxygen isotopic and chemical analyses on six commonly used apatite reference materials (ie, Emerald, Kovdor, McClure, Mud Tank, Otter Lake, and Slyudyanka) and two in-house apatite references (Qinghu and GEMS 203) to assess their oxygen isotope homogeneity and applicability for microbeam analyses. Our results show that all these apatite references are in general chemically homogeneous. In terms of oxygen isotopes, GEMS 203 (δ18O = 9.85 ± 0.40‰ [2SD], corrected by Durango 3), Kovdor (δ18O = 6.55 ± 0.38‰, 2SD), and McClure (δ18O = 5.94 ± 0.42‰, 2SD) are fairly homogeneous, whereas Emerald (δ18O = 10.37 ± 0.45‰, 2SD), Mud Tank (δ18O = 6.35 ± 0.46‰, 2SD), Otter Lake (δ18O = 9.71 ± 0.47‰, 2SD), Qinghu (δ18O = 5.44 ± 0.49‰, 2SD), and Slyudyanka (δ18O = 17.49 ± 0.43‰, 2SD) are less homogenous. This indicates that the former group represents better reference materials for in-situ oxygen isotopic analyses, whilst the latter group can be used as secondary reference material for analytical quality control.  相似文献   

10.
A new interface for the on-line coupling of a liquid chromatograph to a stable isotope ratio mass spectrometer has been developed and tested. The interface is usable for (13)C/(12)C determination of organic compounds, allowing measurement of small changes in (13)C abundance in individual analyte species. All of the carbon in each analyte is quantitatively converted into CO(2) while the analyte is still dissolved in the aqueous liquid phase. This is accomplished by an oxidizing agent such as ammonium peroxodisulfate. The CO(2) is separated from the liquid phase and transferred to the mass spectrometer. It is shown that the whole integrated process does not introduce isotope fractionation. The measured carbon isotope ratios are accurate and reproducible. The sensitivity of the complete system allows isotope ratio determination down to 400 ng of compound on-column. By-passing the high-performance liquid chromatography (HPLC) separation allows bulk isotopic analysis with substantially lower sample amounts than those required by conventional elemental analyzers. The results of the first applications to amino acids, carbohydrates, and drugs, eluted from various types of HPLC columns, are presented. The wide range of chromatographic methods enables the analysis of compounds never before amenable to isotope ratio mass spectrometry techniques and may lead to the development of many new assays.  相似文献   

11.
The reduction of silver phosphate with graphite under vacuum conditions was studied at final reaction temperatures varying from 430 to 915°C to determine: (i) the CO2 extraction yield, and (ii) the oxygen isotopic composition of CO2. The CO2 yield and oxygen isotopic composition were determined on a calibrated dual inlet and triple collector isotope ratio mass spectrometer. We observed the following three stages of the reduction process. (1) At temperatures below 590°C only CO2 is formed, while silver orthophosphate decays to pyrophosphate. (2) At higher temperatures, 590–830°C, predominantly CO is formed from silver pyrophosphate which decays to metaphosphate; this CO was always converted into CO2 by the glow discharge method. (3) At temperatures above 830°C the noticeable sublimation of silver orthophosphate occurs. This observation was accompanied by the oxygen isotope analysis of the obtained CO2. The measured δ18O value varied from ?11.93‰ (at the lowest temperature) to ?20.32‰ (at the highest temperature). The optimum reduction temperature range was found to be 780–830°C. In this temperature range the oxygen isotopic composition of CO2 is nearly constant and the reaction efficiency is relatively high. The determined difference between the δ18O value of oxygen in silver phosphate and that in CO2 extracted from this phosphate is +0.70‰. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
A method has been developed based on an on-line isotope dilution technique couple with laser ablation/inductively coupled plasma mass spectrometry (LA-ICP-MS), for the determination of boron in p-type silicon wafers. The laser-ablated sample aerosol was mixed on-line with an enriched boron aerosol supplied continuously using a conventional nebulization system. Upon mixing the two aerosol streams, the isotope ratio of boron changed rapidly and was then recorded by the ICP-MS system for subsequent quantification based on the isotope dilution principle. As an on-line solid analysis method, this system accurately quantifies boron concentrations in silicon wafers without the need for an internal or external solid reference standard material. Using this on-line isotope dilution technique, the limit of detection for boron in silicon wafers is 2.8 × 1015 atoms cm−3. The analytical results obtained using this on-line methodology agree well with those obtained using wet chemical digestion methods for the analysis of p-type silicon wafers containing boron concentrations ranging from 1.0 × 1016 to 9.6 × 1018 atoms cm−3.  相似文献   

13.
An isotope analytical procedure and an automatic instrument developed for the determination of tritium in organic compounds and biological materials by internal gas counting are described. The sample is burnt in a stream of oxygen and the combustion products including water vapour carrying the tritium are led onto a column of molecular sieve-5A heated to 550 °C. Tritium is retained temporarily on the column, then transferred into a stream of hydrogen by isotope exchange. After addition of butane, the tritiated hydrogen is led into an internal detector and enclosed there for radioactivity measurement. The procedure, providing quantitative recovery, is completed in five minutes. It is free of memory effect and suitable for the determination of tritium in a wide range of organic compounds and samples of biological origin.  相似文献   

14.
Pitfalls in compound-specific isotope analysis of environmental samples   总被引:1,自引:0,他引:1  
In the last decade compound-specific stable isotope analysis (CSIA) has evolved as a valuable technique in the field of environmental science, especially in contaminated site assessment. Instrumentation and methods exist for highly precise measurements of the isotopic composition of organic contaminants even in a very low concentration range. Nevertheless, the determination of precise and accurate isotope data of environmental samples can be a challenge. Since CSIA is gaining more and more popularity in the assessment of in situ biodegradation of organic contaminants, an increasing number of authorities and environmental consulting offices are interested in the application of the method for contaminated site remediation. Because of this, it is important to demonstrate the problems and limitations associated with compound-specific isotope measurements of environmental samples. In this review, potential pitfalls of the analytical procedure are critically discussed and strategies to avoid possible sources of error are provided. In order to maintain the analytical quality and to ensure the basis for reliable stable isotope data, recommendations on groundwater sampling, and sample preservation and storage are given. Important aspects of sample preparation and preconcentration techniques to improve sensitivity are highlighted. Problems related to chromatographic resolution and matrix interference are discussed that have to be considered in order to achieve accurate gas chromatography/isotope ratio mass spectrometry measurements. As a result, the need for a thorough investigation of compound-specific isotope fractionation effects introduced by any step of the overall analytical method by standards with known isotopic composition is emphasized. Finally, we address some important points that have to be considered when interpreting data from field investigations. Figure CSIA Principal (Carbon)  相似文献   

15.
A negative chlorine ion source has been designed and constructed. The source utilizes direct surface ionization of chloromethane gas on a hot metal filament. Four different alloys for the filament material were tested: W99Th1, W75Re25, Hf97.5Zr2.5 and Mo52.5Re47.5. We conclude that the best filament material is the MoRe alloy, for which the signal‐to‐noise ratio is optimal. The ion source is used for chlorine isotope ratio measurements with higher precision and sensitivity than the positive ionization source used previously. Inasmuch as only negative ions of the two isotopes of interest are observed, no corrections to the measured isotope ratio are necessary, and less rigously purified samples may be analyzed. The negative ion currents are considerably larger than positive ion currents obtained with an electron ionization source. This implies higher analytical precision (typically 0.005 permil) and sensitivity. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

16.
A high-precision, and rapid on-line method for oxygen isotope analysis of silver phosphate is presented. The technique uses high-temperature elemental analyzer (EA)-pyrolysis interfaced in continuous flow (CF) mode to an isotopic ratio mass spectrometer (IRMS). Calibration curves were generated by synthesizing silver phosphate with a 13 per thousand spread in delta(18)O values. Calibration materials were obtained by reacting dissolved potassium dihydrogen phosphate (KH(2)PO(4)) with water samples of various oxygen isotope compositions at 373 K. Validity of the method was tested by comparing the on-line results with those obtained by classical off-line sample preparation and dual inlet isotope measurement. In addition, silver phosphate precipitates were prepared from a collection of biogenic apatites with known delta(18)O values ranging from 12.8 to 29.9 per thousand (V-SMOW). Reproducibility of +/- 0.2 per thousand was obtained by the EA-Py-CF-IRMS method for sample sizes in the range 400-500 microg. Both natural and synthetic samples are remarkably well correlated with conventional (18)O/(16)O determinations. Silver phosphate is a very stable material and easy to degas and, thus, could be considered as a good candidate to become a reference material for the determination of (18)O/(16)O ratios of phosphate by high-temperature pyrolysis.  相似文献   

17.
Compound-specific stable isotope analysis (CSIA) using gas chromatography-isotope ratio mass spectrometry (GC/IRMS) has developed into a mature analytical method in many application areas over the last decade. This is in particular true for carbon isotope analysis, whereas measurements of the other elements amenable to CSIA (hydrogen, nitrogen, oxygen) are much less routine. In environmental sciences, successful applications to date include (i) the allocation of contaminant sources on a local, regional, and global scale, (ii) the identification and quantification of (bio)transformation reactions on scales ranging from batch experiments to contaminated field sites, and (iii) the characterization of elementary reaction mechanisms that govern product formation. These three application areas are discussed in detail. The investigated spectrum of compounds comprises mainly n-alkanes, monoaromatics such as benzene and toluene, methyl tert-butyl ether (MTBE), polycyclic aromatic hydrocarbons (PAHs), and chlorinated hydrocarbons such as tetrachloromethane, trichloroethylene, and polychlorinated biphenyls (PCBs). Future research directions are primarily set by the state of the art in analytical instrumentation and method development. Approaches to utilize HPLC separation in CSIA, the enhancement of sensitivity of CSIA to allow field investigations in the µg L–1 range, and the development of methods for CSIA of other elements are reviewed. Furthermore, an alternative scheme to evaluate isotope data is outlined that would enable estimates of position-specific kinetic isotope effects and, thus, allow one to extract mechanistic chemical and biochemical information.Abbreviations BTEX benzene, toluene, ethylbenzene, xylenes - MTBE methyl tert-butyl ether - PAHs polycyclic aromatic hydrocarbons - VOCs volatile compounds - PCBs polychlorinated biphenyls - CSIA compound-specific (stable) isotope (ratio) analysis - GC-IRMS, GC/IRMS or GCIRMS gas chromatography-isotope ratio mass spectrometry - GC-C-IRMS, GC/C/IRMS or GCC-IRMS gas chromatography-combustion-isotope ratio mass spectrometry - irmGC/MS isotope ratio monitoring gas chromatograph-mass spectrometry - GC/P/IRMS gas chromatography-pyrolysis-isotope ratio mass spectrometry (used for D/H) - KIE kinetic isotope effect - PSIA position-specific isotope analysis (for intramolecular isotope distribution) - SNIF-NMR site-specific natural isotopic fractionation by nuclear magnetic resonance spectroscopy  相似文献   

18.
19.
Gaseous membrane permeation (MP) technologies have been combined with continuous‐flow isotope ratio mass spectrometry for on‐line δ13C measurements. The experimental setup of membrane permeation‐gas chromatography/combustion/isotope ratio mass spectrometry (MP‐GC/C/IRMS) quantitatively traps gas streams in membrane permeation experiments under steady‐state conditions and performs on‐line gas transfer into a GC/C/IRMS system. A commercial polydimethylsiloxane (PDMS) membrane sheet was used for the experiments. Laboratory tests using CO2 demonstrate that the whole process does not fractionate the C isotopes of CO2. Moreover, the δ13C values of CO2 permeated on‐line give the same isotopic results as off‐line static dual‐inlet IRMS δ13C measurements. Formaldehyde generated from aqueous formaldehyde solutions has also been used as the feed gas for permeation experiments and on‐line δ13C determination. The feed‐formaldehyde δ13C value was pre‐determined by sampling the headspace of the thermostated aqueous formaldehyde solution. Comparison of the results obtained by headspace with those from direct aqueous formaldehyde injection confirms that the headspace sampling does not generate isotopic fractionation, but the permeated formaldehyde analyzed on‐line yields a 13C enrichment relative to the feed δ13C value, the isotopic fractionation being 1.0026 ± 0.0003. The δ13C values have been normalized using an adapted two‐point isotopic calibration for δ13C values ranging from ?42 to ?10‰. The MP‐GC/C/IRMS system allows the δ13C determination of formaldehyde without chemical derivatization or additional analytical imprecision. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
A simple and rapid method to measure naturally occurring delta(13)C values of headspace CO(2) of sparkling drinks has been set up, using direct injections on a gas chromatograph coupled to an isotope ratio mass spectrometer, through a combustion interface (GC/C/IRMS). We tested the method on CO(2) gas from several origins. No significant isotopic fractionation was observed nor influences by secondary compounds eventually present in the gas phase. Standard deviation for these measurements was found to be <0.1 per thousand.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏