首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The high‐sensitive detection of explosives is of great importance for social security and safety. In this work, the ion source for atmospheric pressure chemical ionization/mass spectrometry using alternating current corona discharge was newly designed for the analysis of explosives. An electromolded fine capillary with 115 µm inner diameter and 12 mm long was used for the inlet of the mass spectrometer. The flow rate of air through this capillary was 41 ml/min. Stable corona discharge could be maintained with the position of the discharge needle tip as close as 1 mm to the inlet capillary without causing the arc discharge. Explosives dissolved in 0.5 µl methanol were injected to the ion source. The limits of detection for five explosives with 50 pg or lower were achieved. In the ion/molecule reactions of trinitrotoluene (TNT), the discharge products of NOx? (x = 2,3), O3 and HNO3 originating from plasma‐excited air were suggested to contribute to the formation of [TNT ? H]? (m/z 226), [TNT ? NO]? (m/z 197) and [TNT ? NO + HNO3]? (m/z 260), respectively. Formation processes of these ions were traced by density functional theory calculations. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
A method was developed for the determination of nine volatile N‐nitrosamines in tobacco and smokeless tobacco products. The targets are N‐nitrosodimethylamine, N‐nitrosopyrrolidine, N‐nitrosopiperidine, N‐nitrosomorpholine, N‐nitrosoethylmethylamine, N‐nitrosodiethylamine, N‐nitrosodipropylamine, N‐nitrosobuylmethylmine, and N‐nitrosodibutylamine. The samples were treated by dispersive solid‐phase extraction using 1 g of primary secondary amine and 0.5 g of carbon and then analyzed by gas chromatography with tandem mass spectrometry with an electron impact ion source. The recoveries for the targets ranged from 84 to 118%, with <16% relative standard deviations at three spiking levels of 0.5, 1.25, and 2.5 ng/g. The limits of detection ranged from 0.03 to 0.15 ng/g. With the use of the proposed method, we detected the presence of six nitrosamines in the range of 0.4–30.7 ng/g. The study demonstrated that the method could be used as a rapid, convenient, and high‐throughput method for N‐nitrosamines analysis in tobacco matrix.  相似文献   

3.
A liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed and validated for the determination of five total tobacco‐specific N‐nitrosamines (TSNA), including free and conjugated forms in urine. The limits of detection for 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanol, N′‐nitrosonornicotine, 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanone, N′‐nitrosoanatabine and N′‐nitrosoanabasine were 0.6, 0.6, 10.0, 0.4 and 0.4 pg/mL, respectively, with a linear calibration range of up to 20,000 pg/mL. Intra‐ and inter‐day precision for TSNA measurements ranged from 0.82 to 3.67% and from 2.04 to 7.73% respectively. For total TSNAs, the β‐glucuronidase amount was optimized for hydrolysis time and yield. Different liquid chromatography columns and mobile phases with different pH conditions were evaluated. The validated method was then applied to 50 smoker and 30 nonsmoker urine samples. Our results suggest that this sensitive and relatively simple analytical method is suitable for application to epidemiological investigations of health risks associated with the exposure to tobacco smoke or secondhand smoke in both smokers and nonsmokers. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.  相似文献   

4.
Tobacco‐specific N‐nitrosamines are carcinogenic components in mainstream cigarette smoke. To explore tobacco‐specific N‐nitrosamine release levels in cigarettes, a magnetic solid‐phase extraction procedure using magnetic graphene composite as sorbent for fast enrichment of tobacco‐specific N‐nitrosamine was developed. Under optimal conditions, a tobacco‐specific N‐nitrosamine determination method was successfully proposed by combining magnetic solid‐phase extraction procedure and high‐performance liquid chromatography coupled with tandem mass spectrometry. The method's limit of detection for tobacco‐specific N‐nitrosamines in mainstream cigarette smoke ranged from 0.018 to 0.057 ng/cigarette. Good linearities were obtained with correlation coefficients above 0.9992. The accuracies of tobacco‐specific N‐nitrosamines in a spiked mainstream cigarette smoke sample were from 89.3 to 109.4%, with a relative standard deviation of less than 11.2%. The proposed method has the merits of rapidity and high sensitivity. Finally, the method was successfully applied to tobacco‐specific N‐nitrosamine analysis in real samples.  相似文献   

5.
Tobacco‐specific N‐nitrosamines (TSNAs), including N′‐nitrosonornicotine, 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanone, N′‐nitrosoanatabine, and N′‐nitrosoanabasine, have been implicated as a source of carcinogenicity in tobacco and cigarette smoke. We present a rapid and effective method comprising SPE based on tetraazacalix[2]arene[2]triazine‐modified silica as sorbent and analysis with HPLC–MS/MS for the determination of TSNAs and 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanol (NNAL), a metabolite of 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanone, in rabbit plasma. The linear dynamic ranges were 10–2000 pg/mL for NNAL and 4–2000 pg/mL for the four TSNAs with good correlation coefficients (>0.9965). The LODs were in the range of 0.9–3.7 pg/mL, and the LOQs were between 2.9 and 12.3 pg/mL. The accuracies of the method were also evaluated and found to be in the range of 90.1–113.3%. This method is promising to be applied to the preconcentration and determination of TSNAs and NNAL in smoke and human body fluids.  相似文献   

6.
An automated dispersive liquid–liquid microextraction integrated with gas chromatography and mass spectrometric procedure was developed for the determination of three N‐nitrosamines (N‐nitroso‐di‐n‐propylamine, N‐nitrosopiperidine, and N‐nitroso di‐n‐butylamine) in water samples. Response surface methodology was employed to optimize relevant extraction parameters including extraction time, dispersive solvent volume, water sample pH, sodium chloride concentration, and agitation (stirring) speed. The optimal dispersive liquid–liquid microextraction conditions were 28 min of extraction time, 33 μL of methanol as dispersive solvent, 722 rotations per minute of agitation speed, 23% w/v sodium chloride concentration, and pH of 10.5. Under these conditions, good linearity for the analytes in the range from 0.1 to 100 μg/L with coefficients of determination (r2) from 0.988 to 0.998 were obtained. The limits of detection based on a signal‐to‐noise ratio of 3 were between 5.7 and 124 ng/L with corresponding relative standard deviations from 3.4 to 5.9% (n = 4). The relative recoveries of N‐nitroso‐di‐n‐propylamine, N‐nitrosopiperidine, and N‐nitroso di‐n‐butylamine from spiked groundwater and tap water samples at concentrations of 2 μg/L of each analyte (mean ± standard deviation, n = 3) were (93.9 ± 8.7), (90.6 ± 10.7), and (103.7 ± 8.0)%, respectively. The method was applied to determine the N‐nitrosamines in water samples of different complexities, such as tap water, and groundwater, before and after treatment, in a local water treatment plant.  相似文献   

7.
A heart‐cutting two dimensional liquid chromatography coupled with tandem mass spectrometry method was developed for the analysis of tobacco‐specific N‐nitrosamines (TSNAs) at low concentration level in Virginia‐type cigarette smoke. A strong cation exchange column was utilized for the first dimensional separation, which effectively removed acidic and neutral components in the smoke, followed by a reversed phase liquid chromatography coupled with tandem mass spectrometric analysis. To capture components of the TSNAs in the effluent on the trapping column, a compensating pump was applied for online dilution and pH adjustment during the period of the TSNAs fraction transferring and enrichment. Highly sensitive determination of the TSNAs in mainstream cigarette smoke was achieved by isotope deuterated internal standards under the multiple reaction monitoring mode. Compared with traditional methodologies, the method was almost no matrix interference. Limits of quantity for the TSNAs were within 0.027–0.094 ng/mL, and the results showed good reproducibility and accuracy. Finally, the new method was applied for analysis of the Kentucky reference cigarettes and the results agreed well with joint experiments of Cooperation Centre for Scientific Research Relative to Tobacco.  相似文献   

8.
A new analytical method for the simultaneous determination of trace levels of seven prohibited N‐nitrosamines (N‐nitrosodimethylamine, N‐nitrosoethylmethylamine, N‐nitrosopyrrolidine, N‐nitrosodiethylamine, N‐nitrosopiperidine, N‐nitrosomorpholine, and N‐nitrosodiethanolamine) in cosmetic products has been developed. The method is based on vortex‐assisted reversed‐phase dispersive liquid–liquid microextraction, which allows the extraction of highly polar compounds, followed by liquid chromatography with mass spectrometry. The variables involved in the extraction process were studied to obtain the highest enrichment factor. Under the selected conditions, 75 μL of water as extraction solvent was added to 5 mL of n‐hexane sample solution and assisted by vortex mixing during 30 s to form the cloudy solution. The method was successfully validated showing good linearity (0.5–50 ng/mL), enrichment factors up to 65 depending on the target compound, limits of detection values of 1.8–50 ng/g, and good repeatability (RSD < 9.8%). Finally, the proposed method was applied to different cosmetic samples. Quantitative relative recovery values (80–113%) were obtained, thus showing that matrix effects were negligible. The achieved analytical features of the proposed method, besides of its simplicity and affordability, make it useful to perform the quality control of cosmetic products to ensure the safety of consumers.  相似文献   

9.
In this study, the capability of negative corona discharge ion mobility spectrometry (IMS) for quantitative magnitude of several explosives including 2,4,6-trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN) and cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) has been evaluated for the first time. The total current obtained with the negative corona discharge was about 100 times larger than that of IMS based on 63Ni, which results in a lower detection limit and a wider linear dynamic range. The detection limits for PETN, TNT and RDX were 8×10−11, 7×10−11 and 3×10−10 g, respectively. The calibration plots for these explosives showed linear dynamic ranges of about four orders of magnitude.  相似文献   

10.
A series of an ionic hydrogels composed of N,N‐diethylaminoethyl methacrylamide (DEAEMA), N‐vinyl‐2‐pyrrolidone (VP), and itaconic acid were synthesized by free‐radical cross‐linking copolymerization in water–ethanol mixture by using N,N‐methylenebis(acrylamide) as the cross‐linker, ammonium persulfate as the initiator, and N,N,N′,N′‐tetramethylenediamine as the activator. The swelling behaviors of these hydrogels were analyzed in buffer solutions at various pH. It was observed that the swelling behavior of cross‐linked ionic poly(N,N‐diethylaminoethyl methacrylamide‐coN‐vinyl‐2‐pyrrolidone) [P(DEAEMA/VP)] hydrogels at different pH agreed with the modified Flory–Rehner equation based on the affine network model and the ideal Donnan theory. The swelling process in buffer solutions at various pH was found to be Fickian‐type diffusion. The pH‐reversibility and on–off switching properties of the P(DEAEMA/VP) hydrogels may be considered as good candidate to design novel drug‐delivery system. © 2005 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 43: 2819–2828, 2005  相似文献   

11.
The pulsed power operation mode of a radiofrequency (rf) glow discharge time‐of‐flight mass spectrometer was investigated, for several ions, in terms of intensity profiles along each pulse period. Particular attention was paid to the plateau and transient afterglow regions. An rf pulse period of 4 ms and a duty cycle of 50% was selected to evaluate the influence of discharge parameters in the afterglow delay and shape of Ar+, Ar2+ and several analytes (Br, Cl, Cu) contained in polymeric layers. Pulse shapes of Ar+ and Ar2+ ions vary with pressure and power. At low pressures the highest intensity is observed in the plateau while at higher pressures (>600 Pa) the afterpeak is the dominant region. Although the influence of the applied power is less noticeable, a widening of the afterglow time regime occurs for Ar+ when increasing the power. Maximum intensity of the argon signal is measured in the afterglow at 30 W, while the area of such afterpeak increases with power. The maximum intensity of Ar2+ is obtained at the highest power employed (60 W) and the ratio maximum intensity/afterglow area remains approximately constant with power. Analytes with ionization potentials below (Cu) or just above (Br) the argon metastable energy show maxima intensities after argon ions decay, indicating they could be ionized by collisions with metastable Ar atoms. Chlorine signals are observed in the afterglow despite their ionization potential is well above the energy of argon metastable levels. Moreover, they follow a similar pattern to that observed for Ar2+, indicating that charge‐transfer process with Ar2+ could play a significant role. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
N‐Boc/Fmoc/Z‐N′‐formyl‐gem‐diaminoalkyl derivatives, intermediates particularly useful in the synthesis of partially modified retro‐inverso peptides, have been characterized by both positive and negative ion electrospray ionization (ESI) ion‐trap multi‐stage mass spectrometry (MSn). The MS2 collision induced dissociation (CID) spectra of the sodium adduct of the formamides derived from the corresponding N‐Fmoc/Z‐amino acids, dipeptide and tripeptide acids show the [M + Na‐NH2CHO]+ ion, arising from the loss of formamide, as the base peak. Differently, the MS2 CID spectra of [M + Na]+ ion of all the N‐Boc derivatives yield the abundant [M + Na‐C4H8]+ and [M + Na‐Boc + H]+ ions because of the loss of isobutylene and CO2 from the Boc protecting function. Useful information on the type of amino acids and their sequence in the N‐protected dipeptidyl and tripeptidyl‐N′‐formamides is provided by MS2 and subsequent MSn experiments on the respective precursor ions. The negative ion ESI mass spectra of these oligomers show, in addition to [M‐H]?, [M + HCOO]? and [M + Cl]? ions, the presence of in‐source CID fragment ions deriving from the involvement of the N‐protecting group. Furthermore, MSn spectra of [M + Cl]? ion of N‐protected dipeptide and tripeptide derivatives show characteristic fragmentations that are useful for determining the nature of the C‐terminal gem‐diamino residue. The present paper represents an initial attempt to study the ESI‐MS behavior of these important intermediates and lays the groundwork for structural‐based studies on more complex partially modified retro‐inverso peptides. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
The gas‐phase chemistry of deprotonated benzyl N‐phenylcarbamates was investigated by electrospray ionization tandem mass spectrometry. Characteristic losses of a substituted phenylcarbinol and a benzaldehyde from the precursor ion were proposed to be derived from an ion‐neutral complex (INC)‐mediated competitive proton and hydride transfer reactions. The intermediacy of the INC consisting of a substituted benzyloxy anion and a phenyl isocyanate was supported by both ortho‐site‐blocking experiments and density functional theory calculations. Within the INC, the benzyloxy anion played the role of either a proton abstractor or a hydride donor toward its neutral counterpart. Relative abundances of the product ions were influenced by the nature of the substituents. Electron‐withdrawing groups at the N‐phenyl ring favored the hydrogen transfer process (including proton and hydride transfer), whereas electron‐donating groups favored direct decomposition to generate the benzyloxy anion (or substituted benzyloxy anion). By contrast, electron‐withdrawing and electron‐donating substitutions at the O‐benzyl ring exhibited opposite effects. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
Typically sweeping reversed migration EKC (RM‐EKC) is used for online enrichment and separation of neutral compounds in CE, however sweeping is not usually suitable for highly polar neutral compounds due to the lack of strong interaction with micellar phase. Since acidic BGE or coated capillaries (BGE pH 2–8) are used to virtually eliminate the EOF, migration of neutral analytes is only through association with the micelles with relatively slow electrophoretic mobility. To decrease the long analysis times that result, an auxiliary pressure can be applied, which also serves to avoid the associated band broadening. In this study, we have modified a commercially available CE instrument to perform pressure‐assisted sweeping. The apparatus described can be used to precisely control the application of pressure, and therefore direction and magnitude of bulk flow in the capillary. This modification allows us to employ longer capillaries and capillaries with larger internal diameter to increase the sensitivity. An optimized method was used for the analysis of a group of seven N‐nitrosamines that have been widely reported in environmental samples and good concentration factors of up to 34 were achieved. When a coated capillary is employed, this method is effective even at neutral pH, making it broadly applicable.  相似文献   

15.
Three new degradation impurities of bupropion were characterized through high performance liquid chromatography coupled to photodiode array detection and to time‐of‐flight mass spectrometry. Bupropion was subjected to the ICH prescribed stress conditions. It degraded to seven impurities (I–VII) in alkaline hydrolytic conditions which were optimally resolved on an XTerra C18 column (250 × 4.6 mm, 5 µm) with a ternary mobile phase comprising ammonium formate (20 mm , pH 4.0), methanol and acetonitrile (75:10:15, v/v). The degradation impurities (III–V and VII) were characterized on the basis of mass fragmentation pattern of drug, accurate mass spectral and photodiode array data of the drug and degradation impurities. Compound V was found to be a known degradation impurity [1‐hydroxy‐1‐(3‐chlorophenyl)propan‐2‐one], whereas III, IV and VII were characterized as 2‐hydroxy‐2‐(3′‐chlorophenyl)‐3,5,5‐trimethylmorpholine, (2,4,4‐trimethyl‐1,3‐oxazolidin‐2‐yl)(3‐chlorophenyl)‐methanone and 2‐(3′‐chlorophenyl)‐3,5,5‐trimethylmorphol‐2‐ene, respectively. Compound III was a known metabolite of the drug. This additional information on the degradation impurities can help in the development of a new stability‐indicating assay method to monitor the stability of the drug product during its shelf‐life as well as in development of a drug product with increased shelf‐life. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
A new sample preparation method based on SBA‐15 assisted electromembrane extraction coupled with corona discharge ion mobility spectrometer was developed for the determination of Thiabendazole as a model basic pesticide in fruit juice samples. The addition of SBA‐15 in the supported liquid membrane in electromembrane extraction system not only can lead to enhancement of the effective surface area, but also introducing the negatively charged silanol groups into supported liquid membrane might improve migration of positively charged analytes toward the supported liquid membrane and finally into the acceptor solution. To investigate the effect of the presence of SBA‐15 in the supported liquid membrane on the extraction efficiency, a comparative study was carried out between the conventional electromembrane extraction and SBA‐15/electromembrane extraction methods. Under the optimized conditions, SBA‐15/electromembrane extraction method showed higher extraction efficiencies in comparison with conventional electromembrane extraction method. SBA‐15/electromembrane extraction method exhibited a low limit of detection (0.9 ng/mL), high preconcentration factor (167) and high recovery (83%). Finally, the applicability of SBA‐15/electromembrane extraction method was studied by the extraction and determination of Thiabendazole as a model basic pesticide in fruit juice samples.  相似文献   

17.
In this article, direct N‐alkylation reactions of amines with alcohols derivatives have been investigated. For this purpose, a new series ruthenium (II) complexes bearing N‐coordinated benzimidazole complexes with have been synthesized and fully characterized by elemental analysis, FT‐IR, 1H NMR and, 13C NMR spectroscopies. Additionally, the structures of the complexes 2b and 2c have been confirmed by X‐ray crystallography. Although the N‐alkylating reaction is usually performed in toluene, the catalytic study of complexes 2a‐d has carried out no additional solvent and alcohol acted both as solvent and reactant of alkylating by using a little excess of alcohols. Surprisingly, conversion and selectivity of amine product for alkylation reaction have been seen high in medium solvent‐free relative to in toluene.  相似文献   

18.
A novel method for the sensitive and selective identification and quantification of N‐acylphosphatidylethanolamine molecular species was developed. Samples were prepared using a combination of liquid–liquid and solid‐phase extraction, and intact N‐acylphosphatidylethanolamine species were determined by reversed‐phase high‐performance liquid chromatography coupled to positive electrospray tandem mass spectrometry. As a result of their biological functions as precursors for N‐acylethanolamines and as signaling molecules, tissue concentrations of N‐acylphosphatidylethanolamines are very low, and their analysis is additionally hindered by the vast excess of other sample components. Our sample preparation methods are able to selectively separate the analytes of interest from any expected biological interferences. Finally, the highest selectivity is achieved by coupling chromatographic separation and two N‐acyl chain specific selected reaction monitoring scans per analyte, enabling identification of both the N‐acyl chain and the phosphatidylethanolamine moiety. The validated method is suitable for the reliable quantification of N‐acylphosphatidylethanolamine species from rat brain with a lower limit of quantification of 10 pmol/g and a linear range up to 2300 pmol/g. In total, 41 N‐acylphosphatidylethanolamine molecular species with six different N‐acyl chains, amounting to a total concentration of 3 nmol/g, were quantified.  相似文献   

19.
The palladium (II) chloride catalyzed coupling reaction of N‐alkylpyridiniumboronic acids with benzoic anhydride was carried out smoothly in water to give high yields of ketones without the use of a phosphine ligand. The reaction was conducted under mild conditions at room temperature. In this article, by focusing on the Suzuki reaction, it is shown how this method can impact modern synthetic chemistry, making reactions faster, easier and cleaner. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
Dual temperature‐ and pH‐sensitive hydrogels composed of N‐isopropylacrylamide (NIPAM) and 2‐acrylamido‐2‐methyl‐propanosulfonic acid (AMPS) were prepared by free‐radical crosslinking copolymerization in aqueous solution at 22 °C. The mole percent of AMPS in the comonomer feed was varied between 0.0 and 7.5, while the crosslinker ratio was fixed at 5.0/100. The effect of AMPS content on thermo‐ and pH‐ induced phase transitions as well as equilibrium swelling/deswelling, interior morphology and network structure was investigated. The volume phase transition temperature (VPT‐T) was determined by both swelling/deswelling measurements and differential scanning calorimetry (DSC) technique. In addition, the volume phase transition pH (VPT‐pH) was detected from the derivative of the curves of the swelling ratio (dQv/dpH) versus pH. The polymer‐solvent interaction parameter (χ) and the average molecular mass between crosslinks ( ) of hydrogels were calculated from swelling ratios in buffer solutions at various pHs. The enthalpy (ΔH) and entropy (ΔS) changes appearing in the χ parameter of hydrogels were also determined by using the modified Flory–Rehner equation. The negative values for ΔH and ΔS indicated that the hydrogels had a negative temperature‐sensitive property in water, that is, swelling at a lower temperature and shrinking at a higher temperature. It was observed that the experimental swelling data of hydrogels at different temperature agreed with the modified Flory‐Rehner approach based on the affine network model. © 2008 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 46: 1713–1724, 2008  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号