首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An on-line LC-GC method for the analysis of mono-, di-, and triacylglycerols in vegetable oil methyl esters has been developed. The concentrations of these components have turned out to be key parameters for the quality of diesel fuel substitutes. Separation of all classes of acylglycerols from the fatty acid methyl ester matrix is achieved by LC after acetylation of the hydroxyl groups. The acylglycerol fraction is transferred on-line to GC, using the loop-type interface and concurrent eluent evaporation. Quantification of mono-, di-, and triacylglycerols is performed by combining external calibration with internal standardization. Both recovery of the procedure and reproducibility of the quantitative results are evaluated.  相似文献   

2.
A method for the analysis of free and esterified sterols has been developed. Fat or oil samples were separated on solid-phase extraction silica gel columns into a sterol ester fraction, a fraction of triacylglycerols, and a free sterol fraction containing partial acylglycerols and residual triacylglycerols. Sterol esters and acylglycerols of the free sterol fraction were transesterified to methyl esters. The fatty acid methyl esters from sterol ester fraction and the free sterols from sterol ester fraction and free sterol fraction were determined by GLC. Precursor ion electrospray MS-MS of sterol fragment ions of sterol ester fractions were recorded and used for determination of sterol ester proportions in butterfat and vegetable oil samples.  相似文献   

3.
A fast and effective cleanup method was developed for the analysis of Sudan I, II, III, IV, and Para Red (Sudan dyes) in various foods and paprika color (oleoresin) by high-performance liquid chromatography (LC) with a diode array detector (DAD). Removal of fat or oil in fatty sample was a critical point for reducing the volume of the final sample solution in order to obtain a sufficient level of the analytes. Separation of fat or oil from the dyes with a silica gel solid-phase extraction (SPE) column seemed unfeasible, because elution profiles of oil, fat, and the dyes were similar. Finally, fat and oil were separated from the dyes by elution from the SPE column with n-hexane, not as intact compounds but as fatty acid methyl esters prepared by direct transesterification of acylglycerols in fat and oil, leaving the dyes on the column. The dyes were eluted with n-hexane-diethyl ether (9 + 1). Gradient elution with water and tetrahydrofuran was used for separation on a C18 column by LC. Measurement of spectral of 0.5 microg/g of Sudan dyes in foods and 1 microg/g in paprika color (oleoresin) with the DAD was achieved.  相似文献   

4.
Pheophytins and pyropheophytin are degradation products of chlorophyll pigments, and their ratios can be used as a sensitive indicator of stress during the manufacturing and storage of olive oil. They increase over time depending on the storage condition and if the oil is exposed to heat treatments during the refining process. The traditional analysis method includes solvent‐ and time‐consuming steps of solid‐phase extraction followed by analysis by high‐performance liquid chromatography with ultraviolet detection. We developed an improved dilute/fluorescence method where multi‐step sample preparation was replaced by a simple isopropanol dilution before the high‐performance liquid chromatography injection. A quaternary solvent gradient method was used to include a fourth strong solvent wash on a quaternary gradient pump, which avoided the need to premix any solvents and greatly reduced the oil residues on the column from previous analysis. This new method not only reduces analysis cost and time but shows reliability, repeatability, and improved sensitivity, especially important for low‐level samples.  相似文献   

5.
An automated on-line method is described that involves a first LC separation on a large column, evaporation of a 6-ml fraction in an on-line solvent evaporator, a second LC separation using a different mobile phase, fractionating the components of interest and transfer to GC through the in-line vaporiser/overflow interface. The method is designed for the injection of a large amount of food extract (e.g. up to 200 mg of fat) and is applied to the analysis of mineral oil material in a linseed oil.  相似文献   

6.
7.
The determination of the fatty acid composition (as methyl esters, FAMEs) of fats and oils and their cis/trans (CTME) distribution requires a simple, but manual and time-consuming sample preparation. The so-called BF3 method is often the preferred procedure. Because FAME/CTME analyses are encountered very frequently in the food industry, an automated, robot-based alternative is proposed which uses the sodium methylate procedure. After sample weighing and the (manual) addition of heptane (2 min), a XYZ robotic autosampler is used for all remaining work, which includes reagent addition, agitation, sample settling and the final injection into the gas chromatograph (10 min). The performance of the sodium methylate and BF3 methods are compared by analysing some 30 oil and fat samples. The novel procedure is much faster (less than 15 min versus ca. 1 h) and manual sample handling is drastically decreased. The experimental results obtained with the two methods frequently are the same, while small differences can be explained by (known) differences of the two methods in the conversion of minor oil/fat constituents, such as free fatty acids, wax esters and sterol esters. In case of FAME analyses, a hot injection is to be preferred over a cold injection. The RSDs of the peak areas were 1.5% for the major fatty acids to 11% for peaks that were just above the noise level. The detection limit were approximately 0.03%.  相似文献   

8.
The determination of trace elements in oil samples and their products is of high interest as their presence significantly affects refinery processes and the environment by possible impact of their combustion products. In this context, inductively coupled plasma mass spectrometry (ICP-MS) plays an important role due to its outstanding analytical properties in the quantification of trace elements. In this work, we present the accurate and precise determination of selected heavy metals in oil samples by making use of the combination of μ-flow direct injection and isotope dilution ICP-MS (ICP-IDMS). Spike solutions of 62Ni, 97Mo, 117Sn and 206Pb were prepared in an organic solvent, mixed directly with the diluted oil samples and tested to be fit for purpose for the intended ID approach. The analysis of real samples revealed strong matrix effects affecting the ICP-MS sensitivity, but not the isotope ratio measurements, so that accurate results are obtained by ICP-IDMS. Typical relative standard deviations were about 15% for peak area and peak height measurements, whereas the isotope ratios were not significantly affected (RSD < 2%). The developed method was validated by the analysis of a metallo-organic multi-element standard (SCP-21, typically applied as a calibration standard) and the standard reference material SRM1084a (wear metals in lubricating oil). The obtained results were in excellent agreement with the certified values (recoveries between 98% and 102%), so the proposed methodology of combining μ-flow direct injection and ICP-IDMS can be regarded as a new tool for the matrix-independent, multi-element and reliable determination of trace elements in oil and related organic liquids.  相似文献   

9.
Pyrolysis oils have attracted a lot of interest, as they are liquid energy carriers and general sources of chemicals. In this work, gas chromatography with flame ionization detector (GC-FID) and two-dimensional gas chromatography with time-of-flight mass spectrometry (GC×GC-TOFMS) techniques were used to provide both qualitative and quantitative results of the analysis of three different pyrolysis oils. The chromatographic methods and parameters were optimized and solvent choice and separation restrictions are discussed. Pyrolysis oil samples were diluted in suitable organic solvent and were analyzed by GC×GC-TOFMS. An average of 300 compounds were detected and identified in all three samples using the ChromaToF (Leco) software. The deconvoluted spectra were compared with the NIST software library for correct matching. Group type classification was performed by use of the ChromaToF software. The quantification of 11 selected compounds was performed by means of a multiple-point external calibration curve. Afterwards, the pyrolysis oils were extracted with water, and the aqueous phase was analyzed both by GC-FID and, after proper change of solvent, by GC×GC-TOFMS. As previously, the selected compounds were quantified by both techniques, by means of multiple point external calibration curves. The parameters of the calibration curves were calculated by weighted linear regression analysis. The limit of detection, limit of quantitation and linearity range for each standard compound with each method are presented. The potency of GC×GC-TOFMS for an efficient mapping of the pyrolysis oil is undisputable, and the possibility of using it for quantification as well has been demonstrated. On the other hand, the GC-FID analysis provides reliable results that allow for a rapid screening of the pyrolysis oil. To the best of our knowledge, very few papers have been reported with quantification attempts on pyrolysis oil samples using GC×GC-TOFMS most of which make use of the internal standard method. This work provides the ground for further analysis of pyrolysis oils of diverse sources for a rational design of both their production and utilization process.  相似文献   

10.
《Fluid Phase Equilibria》2004,215(2):227-236
In the present work, a group contribution method is proposed for the estimation of the vapor pressure of fatty compounds. For the major components involved in the vegetable oil industry, such as fatty acids, esters and alcohols, triacylglycerols (TAGs) and partial acylglycerols, the optimized parameters are reported. The method is shown to be accurate when it is used together with the UNIFAC model for estimating vapor–liquid equilibria (VLE) of binary and multicomponent fatty mixtures comprised in industrial processes such as stripping of hexane, deodorization and physical refining. The results achieved show that the group contribution approach is a valuable tool for the design of distillation and stripping units since it permits to take into account all the complexity of the mixtures involved. This is particularly important for the evaluation of the loss of distillative neutral oil that occurs during the processing of edible oils.The combination of the vapor pressure model suggested in the present work with the UNIFAC equation gives results similar to those already reported in the literature for fatty acid mixtures and oil–hexane mixtures. However, it is a better tool for predicting vapor–liquid equilibria of a large range of fatty systems, also involving unsaturated compounds, fatty esters and acylglycerols, not contemplated by other methodologies. The approach suggested in this work generates more realistic results concerning vapor–liquid equilibria of systems encountered in the edible oil industry.  相似文献   

11.
The applicability of programmable temperature vaporizer (PTV) solvent vent injection to the gas chromatographic (GC) determination of pesticide residues in fruits and vegetables was evaluated with the aim of miniaturizing the current multiresidue method. For that purpose 24 pesticides representing different chemical classes were initially chosen for optimisation of the large volume injection (LVI) parameters. Various parameters related to the optimum injector performance were tested for several types of packed and empty liners using both fast (at-once) and speed-controlled PTV solvent vent injection of standard solutions in ethyl acetate. In the next step, several packed and empty liners were evaluated for their suitability for pesticide multiresidue analysis. Parameters identified as optimal were then applied for PTV solvent vent injection of sample extracts prepared using the miniaturized multiresidue method to assess the long-term stability of the system. The combined use of large volume injection of 10 microl ethyl acetate extract into an empty multi-baffled or a CarboFrit packed liner using PTV injectors and GC-MS analysis enabled the detection and quantification of 124 pesticides in fruit and vegetable samples at the 0.01 mg/kg level using miniaturized reversed-phase solid-phase extraction (RP-SPE) of diluted acetone extract and clean-up on a small anion-exchange SPE column.  相似文献   

12.
An on-line combination of gel permeation chromatography and gas chromatography has been designed using either a laboratory-built or a commercially available LC-GC apparatus to determine organophosphorus pesticides in olive oil. Gel permeation chromatography was used for sample pretreatment, viz. to separate the low-molecular-mass pesticides from the higher-molecular-mass fat constituents of the oil. A mixture of n-decane and the azeotropic mixture of ethyl acetate and cyclohexane was found to give an adequate separation between the fat and the organophosphorus pesticides. The pesticide-containing fraction, monitored by a UV detector, was transferred on-line to the gas chromatograph using a loop-type interface. n-Decane (6%, v/v) was added to the eluent in order to widen the application range of the transfer technique towards more volatile pesticides. After solvent evaporation through the solvent vapour exit and subsequent GC separation, the compounds were selectively detected with a thermionic or a flame photometric detector. The set-up allowed the direct analysis of oil samples after dilution in the gel permeation chromatography eluent without further sample clean-up. Detection limits were about 5 and 10 μg/kg with the thermionic and the flame photometric detector, respectively, when using an injection volume of only 30 μl of the 20-fold diluted oil. The total procedure was linear in the 0.01–10 mg/kg range for both detectors. For twenty organophosphorus pesticides, the relative standard deviations were 3–13% at the 20–60 μg/kg level.  相似文献   

13.
Gas chromatrography (GC) with sulfur chemiluminescence detection (SCD) is an outstanding combination for selectively determining trace concentrations of sulfur compounds in hydrocarbon samples. GC peaks can be identified by retention times when reproducible, automated injection techniques are used. However, as described in this work, analysts should be on the look out for retention shifting due to solvent effects from sample components. Three examples of retention shifting are presented: (1) thiophene by benzene; (2) methylthiophenes by toluene; and (3) dibenzothiophene by gas oil. Depending on samples and analysis conditions, retention shifts from a few hundredths to 1.5 min have been observed. Such retention shifts are likely to cause errors in peak identifications. Therefore, when using SCD, simultaneous FID monitoring is recommended as an aid in evaluating chromatograms for possible retention shifting due to solvent effects.  相似文献   

14.
The PTV (Programmable Temperature Vaporizer) is a split/splitless injector which allows the sample to be introduced at a relatively low temperature, thus affording accurate and reproducible sampling. After injection the PTV is rapidly heated to transfer the vaporized components into the capillary column. This type of injector has proved to be an efficient tool for the evaluation of fatty acids, essential oils, and pesticides in food analysis. In this work the suitability of PTV for the analysis of milk fat purity by the Official EU method was evaluated. This method is based on the gas chromatographic determination of triglycerides only according to their total number of carbon atoms followed by the application of formulae deriving from multiple linear regressions. The analysis is currently carried out with a packed column or a short capillary column and an on-column injection system. Several samples of pure milk fat and mixtures of milk fat with foreign fat were analyzed with the same capillary column and by using both PTV and on-column injection systems. The results show that the gas chromatographic profile obtained by PTV is comparable with that obtained by the on-column injector, while repeatability and reproducibility data meet the requirements indicated in the Official Method. Therefore, this study demonstrates that it is possible to use the PTV instead of the on-column injector to determine the purity of milk fat with this method.  相似文献   

15.
Selective pressurized liquid extraction (PLE) of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) from various food and feed samples was performed with a selective PLE method previously developed for bulk PCBs. The method utilizes sulfuric acid impregnated silica inside the extraction cell to oxidize coextracted fat. Extractions were performed at 100 degrees C with n-heptane for 5 min in two cycles. Data obtained by selective PLE combined with gas chromatography/high-resolution mass spectrometry (GC-HRMS) were compared to concentrations derived from reference laboratories applying conventional sample preparation and GC-HRMS. Experiments performed on spiked vegetable oil, naturally contaminated crude fish oil and oil containing compound feed samples showed good results for these relatively simple matrices. The accuracy was generally +/-20% as compared to spiked levels or to values obtained by the reference laboratories. The precision, measured as the relative standard deviation (RSD) for 2,3,7,8-tetrachlorodibenzo-p-dioxin toxic equivalency values (TEQs), was below 10% in all cases. The method was also tested on naturally contaminated herring tissue, chicken tissue, pork tissue and sepiolitic clay, which all caused some trouble. It was observed that sufficient amounts of sodium sulfate should be used for dehydration of tissue samples and additionally, the cells should not be packed too dense in order to avoid suppressed extraction efficiency. Once this was attended to, satisfactory data could be obtained, except for sepiolithic clay. This study demonstrates that selective PLE can be applied with success to a number of food and feed matrices in analysis of PCDD/Fs and dl-PCBs. Since the fat removal step is on-line, the selective PLE method will reduce time and solvent consumption for sample preparation as compared to traditional clean-up.  相似文献   

16.
This work details a rapid analytical method using direct sample injection for the simultaneous identification/quantification of 22 drugs of abuse, including some of their major metabolites, in environmental samples. This has been developed using a hybrid triple quadrupole-linear ion trap-mass spectrometer (QqLIT). With the increasing sensitivity of today's tandem mass spectrometers, direct injection analysis of water samples has become an attractive alternative to traditional analytical protocols, which often include a preliminary pre-concentration step. What's more, this kind of analysis is in accordance with many of the main objectives of so-called green analytical chemistry, or environmentally friendly practice. The analytical performance of the LC-MS/MS method was evaluated in three different water matrices (surface water, influent and effluent wastewater). Data acquisition was carried out in selected reaction monitoring (SRM) mode under time-scheduled conditions, monitoring two SRM transitions for simultaneous identification/quantification of all target compounds in the samples. Additionally, an experiment was performed using the information-dependent acquisition (IDA) scan to carry out the identification of those analytes for which the second transition was present at a low intensity. Finally, the two methodologies developed were applied to real samples for evaluation.  相似文献   

17.
Determination of phospholipids in dairy products by SPE/HPLC/ELSD   总被引:10,自引:0,他引:10  
The aim of this work was to evaluate the performance of different methods for both milk lipid extraction and phospholipids separation. As far as the lipid extraction procedure is concerned, the Folch method showed a higher phospholipid recovery with respect to the Rose-Gottlieb method. Different SPE cartridges and solvent phases were tested to carry out the separation of phospholipids from fat. The yield of extraction was evaluated by isolating phospholipids from both milk fat and synthetic fat; Standard Addition Method was applied as well. The isolation of the phospholipids by SPE silica column and subsequent analysis by HPLC/ELSD was shown to be an accurate and reproducible analytical method for the determination of phosphatidylethanolamine, phosphatidylinositol, phosphatidylserine, phosphatidylcholine and sphingomyelin in milk fat extracted by Folch method.  相似文献   

18.
超临界流体萃取法对有机锡化合物的选择性萃取   总被引:6,自引:0,他引:6  
 研究了用超临界流体萃取法直接从脂肪基质的固体样品(大豆粉)中选择性地萃取有机锡化合物的方法。模拟试样萃取结果表明:用较低压力和较高温度的超临界态CO2作流动相时,有机锡达到最大萃取率,而脂肪类物质仅被少量萃取,从而消除了脂肪类物质对超临界流体色谱法测定有机锡的干扰。  相似文献   

19.
Two methods for determination of cholesterol in fat and muscle of pig were evaluated: extraction with chloroform:methanol (2:1, v/v) followed by saponification (method 1) and direct saponification (method 2). HPLC and GC were used to determine cholesterol concentrations. GC analysis was performed with a capillary column of 100 μm using a PTV injector in the modes of cold split and solvent venting. Cholesterol was analyzed without derivatization. Both methods of extraction did not present significant differences (p > 0.01). Sample analysis by GC with solvent venting injection and HPLC showed the lowest % r.s.d. but GC in the cold split mode allowed to obtain a shorter analysis time. Cholesterol concentrations obtained by HPLC were not statistically different from the results obtained by GC with solvent venting injection and were slightly lower than those previously reported. Cholesterol concentrations in fat and muscle tissues respectively ranged from 52 to 77 mg/100 g and from 55 to 65 mg/100 g.  相似文献   

20.
Waxes and fatty acid alkyl esters are minor components used as official parameters to control the authenticity and quality of a high‐value olive oil product. A poor measurement can lead to a misleading classification of the oil. The official method requires their analysis together by capillary gas chromatography equipped with a flame ionization detector and an on‐column injector to avoid discrimination and thermal degradation. The degradation can occur to a different extent if different (and not properly optimized) injectors are used. However, other injection techniques, such as programmed‐temperature vaporizer, are much more versatile and more widespread. The aim of the present work was to compare the performance of a programmed‐temperature vaporizer injector, in on‐column and splitless mode, with the on‐column injector to analyze alkyl esters and waxes. Discrimination among high‐boiling compounds was evaluated, as well as the occurrence of thermal degradation, especially of sterols and diterpene alcohol (phytyl and geranylgeraniol) esters. A proper optimization of a programmed‐temperature vaporizer injection, with particular attention to the liner selection, was proven to provide comparable results to the traditional on‐column injection. A performance comparison was carried out both on standard mixtures and on real oil samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号