首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
2.
Proton transfer reaction time of flight mass spectrometry (PTR‐ToF‐MS) is a direct injection MS technique, allowing for the sensitive and real‐time detection, identification, and quantification of volatile organic compounds. When aiming to employ PTR‐ToF‐MS for targeted volatile organic compound analysis, some methodological questions must be addressed, such as the need to correctly identify product ions, or evaluating the quantitation accuracy. This work proposes a workflow for PTR‐ToF‐MS method development, addressing the main issues affecting the reliable identification and quantification of target compounds. We determined the fragmentation patterns of 13 selected compounds (aldehydes, fatty acids, phenols). Experiments were conducted under breath‐relevant conditions (100% humid air), and within an extended range of reduced electric field values (E/N = 48–144 Td), obtained by changing drift tube voltage. Reactivity was inspected using H3O+, NO+, and O2+ as primary ions. The results show that a relatively low (<90 Td) E/N often permits to reduce fragmentation enhancing sensitivity and identification capabilities, particularly in the case of aldehydes using NO+, where a 4‐fold increase in sensitivity is obtained by means of drift voltage reduction. We developed a novel calibration methodology, relying on diffusion tubes used as gravimetric standards. For each of the tested compounds, it was possible to define suitable conditions whereby experimental error, defined as difference between gravimetric measurements and calculated concentrations, was 8% or lower.  相似文献   

3.
Instant coffee is a widespread product, generally related to a high consumer acceptability, also because of its ease of preparation. The present work addresses the characterization of the headspace of freshly brewed instant coffees resulting from different blends, during and immediately after preparation. The sample set consisted of 10 coffees, obtained by mixing three different blends in different proportions. The employment of Proton Transfer Reaction‐Mass Spectrometry (PTR‐MS) allowed for direct and real‐time sampling from the headspace, under conditions that mimic those that are encountered above the cup during and right after brewing. Different coffee brews were separated on the basis of the respective volatile profiles, and data showed good consistency with the respective blend compositions. When the headspace evolution was monitored during preparation, similar results were obtained in terms of blend separation; moreover, different blends displayed different and reproducible ‘signatures’ in terms of time evolution. A straightforward method for the prediction of headspace composition is proposed, allowing to predict the volatile profiles of two‐component and three‐component blends on the basis of the respective parent components. Overall, the results constitute a successful example of the applicability of PTR‐MS as a tool for product development in food science. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
The isomers 4‐methylethcathinone and N‐ethylbuphedrone are substitutes for the recently banned drug mephedrone. We find that with conventional proton transfer reaction mass spectrometry (PTR‐MS), it is not possible to distinguish between these two isomers, because essentially for both substances, only the protonated molecules are observed at a mass‐to‐charge ratio of 192 (C12H18NO+). However, when utilising an advanced PTR‐MS instrument that allows us to switch the reagent ions (selective reagent ionisation) from H3O+ (which is commonly used in PTR‐MS) to NO+, O2+ and Kr+, characteristic product (fragment) ions are detected: C4H10N+ (72 Da) for 4‐methylethcathinone and C5H12N+ (86 Da) for N‐ethylbuphedrone; thus, selective reagent ionisation MS proves to be a powerful tool for fast detection and identification of these compounds. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
We apply, for first time, the recently developed proton transfer reaction time‐of‐flight mass spectrometry (PTR‐TOF‐MS) apparatus as a rapid method for the monitoring of lactic acid fermentation (LAF) of milk. PTR‐TOF‐MS has been proposed as a very fast, highly sensitive and versatile technique but there have been no reports of its application to dynamic biochemical processes with relevance to the food industry. LAF is a biochemical‐physicochemical dynamic process particularly relevant for the dairy industry as it is an important step in the production of many dairy products. Further, LAF is important in the utilization of the by‐products of the cheese industry, such as whey wastewaters. We show that PTR‐TOF‐MS is a powerful method for the monitoring of major volatile organic chemicals (VOCs) formed or depleted during LAF, including acetaldehyde, diacetyl, acetoin and 2‐propanone, and it also provides information about the evolution of minor VOCs such as acetic acid, 2,3‐pentanedione, ethanol, and off‐flavor related VOCs such as dimethyl sulfide and furfural. This can be very important considering that the conventional measurement of pH decrease during LAF is often ineffective due to the reduced response of pH electrodes resulting from the formation of protein sediments. Solid‐phase microextraction gas chromatography/mass spectrometry (SPME‐GC/MS) data on the inoculated milk base and final fermented product are also presented to supporting peak identification. We demonstrate that PTR‐TOF‐MS can be used as a rapid, efficient and non‐invasive method for the monitoring of LAF from headspace, supplying important data about the quality of the final product and that it may be used to monitor the efficacy of manufacturing practices. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) is a powerful tool for determining surface information of complex systems such as polymers and biological materials. However, the interpretation of ToF‐SIMS raw data is often difficult. Multivariate analysis has become effective methods for the interpretation of ToF‐SIMS data. Some of multivariate analysis methods such as principal component analysis and multivariate curve resolution are useful for simplifying ToF‐SIMS data consisting of many components to that explained by a smaller number of components. In this study, the ToF‐SIMS data of four layers of three polymers was analyzed using these analysis methods. The information acquired by using each method was compared in terms of the spatial distribution of the polymers and identification. Moreover, in order to investigate the influence of surface contamination, the ToF‐SIMS data before and after Ar cluster ion beam sputtering was compared. As a result, materials in the sample of multiple components, including unknown contaminants, were distinguished. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) provides detailed molecular insight into the surface chemistry of a diverse range of material types. Extracting useful and specific information from the mass spectra and reducing the dimensionality of very large datasets are a challenge that has not been fully resolved. Multivariate analysis has been widely deployed to assist in the interpretation of ToF‐SIMS data. Principal component analysis is a popular approach that requires the generation of peak lists for every spectrum. Peak list sizes and the resulting data matrices are growing, complicating manual peak selection and analysis. Here we report the generation of very large ToF‐SIMS peak lists using up‐binning, the mass segmentation of spectral data in the range 0 to 300 m/z in 0.01 m/z intervals. Time‐of‐flight secondary ion mass spectrometry data acquired from a set of 4 standard polymers (polyethylene terephthalate, polytetrafluoroethylene, poly(methyl methacrylate), and low‐density polyethylene) are used to demonstrate the efficacy of this approach. The polymer types are discriminated to a moderate extent by principal component analysis but are easily skewed with saturated species or contaminants present in ToF‐SIMS data. Artificial neural networks, in the form of self‐organising maps, are introduced and provide a non‐linear approach to classifying data and focussing on similarities between samples. The classification outcome achieved is excellent for different polymer types and for spectra from a single polymer type generated by using different primary ions. This method offers great promise for the investigation of more complex systems including polymer classes and blends and mixtures of biological materials.  相似文献   

8.
A novel infrared‐assisted extraction coupled to headspace solid‐phase microextraction followed by gas chromatography with mass spectrometry method has been developed for the rapid determination of the volatile components in tobacco. The optimal extraction conditions for maximizing the extraction efficiency were as follows: 65 μm polydimethylsiloxane‐divinylbenzene fiber, extraction time of 20 min, infrared power of 175 W, and distance between the infrared lamp and the headspace vial of 2 cm. Under the optimum conditions, 50 components were found to exist in all ten tobacco samples from different geographical origins. Compared with conventional water‐bath heating and nonheating extraction methods, the extraction efficiency of infrared‐assisted extraction was greatly improved. Furthermore, multivariate analysis including principal component analysis, hierarchical cluster analysis, and similarity analysis were performed to evaluate the chemical information of these samples and divided them into three classifications, including rich, moderate, and fresh flavors. The above‐mentioned classification results were consistent with the sensory evaluation, which was pivotal and meaningful for tobacco discrimination. As a simple, fast, cost‐effective, and highly efficient method, the infrared‐assisted extraction coupled to headspace solid‐phase microextraction technique is powerful and promising for distinguishing the geographical origins of the tobacco samples coupled to suitable chemometrics.  相似文献   

9.
Cyanobacteria, also called blue‐green algae, occur worldwide within water blooms in eutrophic lakes and drinking water reservoirs, producing several biotoxins (cyanotoxins). Among these, microcystins (MCs) are a group of cyclic heptapeptides showing potent hepatotoxicity and activity as tumour promoters. So far, at least 89 MCs from different cyanobacteria genera have been characterised. Herein, ion trap, matrix‐assisted laser desorption/ionisation time‐of‐flight (MALDI‐ToF) and quadruple time‐of‐flight (Q‐ToF) mass spectrometry (MS)‐based methods were tested and compared for analysing MCs in freshwaters. Method performances in terms of limit of detection, limit of quantification, mean recoveries, repeatability, and specificity were evaluated. In particular, a liquid chromatography/electrospray ionisation (LC/ESI)‐Q‐ToF‐MS/MS method was firstly described to analyse MCs in freshwaters; this technique is highly selective and sensitive, and allowed us to characterise the molecular structure of an unknown compound. Indeed, the full structural characterisation of a novel microcystin variant from a bloom of Planktothrix rubescens in the Lake Averno, near Naples, was attained by the study of the fragmentation pattern. The new cyanotoxin was identified as the 9‐acetyl‐Adda variant of microcystin‐RR. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
A systematic study of five different imidazolium‐based room temperature ionic liquids, 1‐butyl‐3‐methylimidazolium acetate, 1‐butyl‐3‐methylimidazolium nitrate, 1‐butyl‐3‐methylimidazolium iodide, 1‐butyl‐3‐methylimidazolium hexafluorophosphate and 1‐butyl‐3‐methylimidazolium bis(trifluoromethylsulfonyl)imide were carried out by means of time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) in positive and negative ion mode. The compounds were measured under Bi‐ion and Bi‐cluster ions (Bi2–7+, Bi3, 52+) bombardment, and spectral information and general rules for the fragmentation pattern are presented. Evidence for hydrogen bonding, due to high molecular secondary cluster ions, could be found. Hydrogen bonding strength could be estimated by ToF‐SIMS via correlation of the anionic yield enhancement with solvent parameters. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
ToF‐SIMS spectra are formed by bombarding a surface with a pulse of primary ions and detecting the resultant ionized surface species using a time‐of‐flight mass spectrometer. Typically, the detector is a time‐to‐digital converter. Once an ion is detected using such detectors, the detector becomes insensitive to the arrival of additional ions for a period termed as the (detector) dead‐time. Under commonly used ToF‐SIMS data acquisition conditions, the time interval over which ions arising from a single chemical species reach the detector is on the order of the detector dead‐time. Thus, only the first ion reaching the detector at any given mass is counted. The event registered by the data acquisition system, then, is the arrival of one or more ions at the detector. This behavior causes ToF‐SIMS data to violate, in the general case, the assumption of linear additivity that underlies many multivariate statistical analysis techniques. In this article, we show that high‐mass‐resolution ToF‐SIMS spectral‐image data follow a generalized linear model, and we propose a data transformation and scaling procedure that enables such data sets to be successfully analyzed using standard methods of multivariate image analysis. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
A simple and convenient method for the synthesis of end functionalized polylactides (PLAs) under mild conditions by ring opening polymerization (ROP) in the absence of potentially toxic catalysts is described. Various alcohols were used as initiators in combination with Ca[N(SiMe3)2]2(THF)2 as the precatalyst in THF at room temperature. Tailored end functionalities were obtained in a controlled fashion. Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐ToF‐MS) and electrospray ionization quadrupole time of flight mass spectrometry (ESI‐Q‐ToF‐MS) analysis were performed to investigate the end groups. The results confirmed that the end group fidelity was maintained in the isolated PLAs. © 2015 Wiley Periodicals, Inc. J. Polym. Sci., Part A: Polym. Chem. 2016 , 54, 437–448  相似文献   

13.
Traditional Asian lacquers are natural products with highly valued properties, including beauty, gloss, and durability. Pyrolysis‐gas chromatography/mass spectrometry is the technique of choice to study insoluble polymeric lacquer films. In the present study, pyrolysis‐gas chromatography/mass spectrometry results showed that the pyrolysis products of lacquer films were different for all of the studied trees, with urushiol derivatives detected in Toxicodendron vernicifluum from China, Japan, and Korea; laccol in Toxicodendron succedaneum from Vietnam; and thitsiol in Gluta usitata from Myanmar. Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) was also used to characterize the Asian lacquers, avoiding the time‐consuming and destructive processes of other techniques. The ToF‐SIMS spectra provided structural characterization of a series of urushiol, laccol, and thitsiol derivatives for T vernicifluum from China, Japan, and Korea; T succedaneum from Vietnam; and G usitata from Myanmar, respectively. To differentiate the ToF‐SIMS results for the different Asian lacquer films, principal component analysis was used because it can extract differences in the spectra and indicate what peaks are responsible for these differences. The results indicate that lacquer films from different lacquer trees can be very different. Therefore, ToF‐SIMS with principal component analysis is suitable for the characterization and differentiation of Asian lacquer films in cultural heritage applications.  相似文献   

14.
Directed self‐assembly of block copolymers (BCPs) is a promising candidate for next generation nanolithography. In order to validate a given pattern, the lateral and in‐depth distributions of the blocks should be well characterized; for the latter, time‐of‐flight (ToF) SIMS is a particularly well‐adapted technique. Here, we use an ION‐TOF ToF‐SIMS V in negative mode to provide qualitative information on the in‐depth organization of polystyrene‐b‐polymethylmethacrylate (PS‐b‐PMMA) BCP thin films. Using low‐energy Cs+ sputtering and Bi3+ as the analysis ions, PS and PMMA homopolymer films are first analyzed in order to identify the characteristic secondary ions for each block. PS‐b‐PMMA BCPs are then characterized showing that self‐assembled nanodomains are clearly observed after annealing. We also demonstrate that the ToF‐SIMS technique is able to distinguish between the different morphologies of BCP investigated in this work (lamellae, spheres or cylinders). ToF‐SIMS characterization on BCP is in good agreement with XPS analysis performed on the same samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) was utilized to study dendritic macromolecules with various architectures, such as dendrons, dendrimers and hyperbranched polyesters prepared from bis‐(hydroxymethyl)propionic acid (Bis‐MPA) and a series of hyperbranched polyethers based on 3‐ethyl‐3(hydroxymethyl)oxetane. The measurements were performed on spin‐coated thin films of the branched molecules (D) onto silicon, chemically etched copper foil and silver‐coated wafers. They showed weak signatures of molecular ions by proton capture (D + H)+ in the high mass range of the spectra (m/z > 400). On the contrary, cationization of the intact molecules with alkali or transition metal ions such as Na+, Cu+ or Ag+ was observed. High‐intensity quasi‐molecular ions (D + M)+ (with M = Na+, Cu+ or Ag+) allowed the studied polymers to be identified. The whole molecular species were observed for Bis‐MPA dendrons and dendrimers up to 3000 Da for hydroxyl or acetonide‐terminated derivatives. The success of the so‐called cationization experiments with metal substrates compared with analysis of molecular adsorbates on silicon is highlighted. The ToF‐SIMS sensitivity appeared useful to provide information about the molecular end‐groups or to highlight incomplete reaction occurring during some deprotection step of the synthesis. Only uncationized fragments of low masses were detected for the hyperbranched polyesters. This result suggested the effect of molecular asymmetry and/or flattening of the molecules on the substrates, which hampered the molecule lift‐off efficiency. Nevertheless, the hyperbranched polyethers were characterized based on the peak distribution of intensities, which allowed estimation of their molecular weight average. This work was intended to illustrate the capabilities of ToF‐SIMS to analyse dendritic polymers on surfaces. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

16.
Like many new designer drugs of abuse, synthetic cannabinoids (SC) have structural or positional isomers which may or may not all be regulated under law. Differences in acute toxicity may exist between isomers which impose further burden in the fields of forensic toxicology, medicine and legislation. Isomer differentiation therefore becomes crucial from these standpoints as new designer drugs continuously emerge with just minor positional modifications to their preexisting analogs. The aim of this study was to differentiate the positional isomers of JWH‐081. Purchased standard compounds of JWH‐081 and its positional isomers were analyzed by gas chromatography‐electron ionization‐mass spectrometry (GC‐EI‐MS) first in scan mode to investigate those isomers who could be differentiated by EI scan spectra. Isomers with identical or near‐identical EI spectra were further subjected to GC‐tandem mass spectrometry (MS/MS) analysis with appropriate precursor ions. EI scan was able to distinguish 3 of the 7 isomers: 2‐methoxy, 7‐methoxy and 8‐methoxy. The remaining isomers exhibited near‐identical spectra; hence, MS/MS was performed by selecting m/z 185 and 157 as precursor ions. 3‐Methoxy and 5‐methoxy isomers produced characteristic product ions that enabled the differentiation between them. Product ion spectrum of 6‐methoxy isomer resembled that of JWH‐081; however, the relative ion intensities were clearly different from one another. The combination of EI scan and MS/MS allowed for the regioisomeric differentiation of the targeted compounds in this study. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
The continuous development in analytical instrumentation has brought the newly developed Orbitrap‐based gas chromatography / mass spectrometry (GC/MS) instrument into the forefront for the analysis of complex mixtures such as crude oil. Traditional instrumentation usually requires a choice to be made between mass resolving power or an efficient chromatographic separation, which ideally enables the distinction of structural isomers that is not possible by mass spectrometry alone. Now, these features can be combined, thus enabling a deeper understanding of the constituents of volatile samples on a molecular level. Although electron ionization is the most popular ionization method employed in GC/MS analysis, the need for softer ionization methods has led to the utilization of atmospheric pressure ionization sources. The last arrival to this family is the atmospheric pressure photoionization (APPI), which was originally developed for liquid chromatography / mass spectrometry (LC/MS). With a newly developed commercial GC‐APPI interface, it is possible to extend the characterization of unknown compounds. Here, first results about the capabilities of the GC/MS instrument under high or low energy EI or APPI are reported on a volatile gas condensate. The use of different ionization energies helps matching the low abundant molecular ions to the structurally important fragment ions. A broad range of compounds from polar to medium polar were successfully detected and complementary information regarding the analyte was obtained.  相似文献   

18.
The oxidation behavior of DNA and RNA nucleotides is studied by an on‐line set‐up consisting of an electrochemical thin‐layer cell (EC) directly coupled to electrospray ionization mass spectrometry (ESI‐MS). This set‐up allows the generation of nucleotide oxidation products in the electrochemical cell at increasing potentials. Moreover, the products are determined directly, without isolation or derivatization steps, by electrospray ionization time of flight mass spectrometry (ESI‐ToF/MS). The dependence of the mass spectra on the applied potential is displayed as ‘mass voltammograms’. An advanced set‐up, consisting of the electrochemical cell coupled to electrospray ionization tandem mass spectrometry (EC/ESI‐MS/MS) allows further structure elucidation based on fragmentation experiments. The electrochemical conversion is performed using a boron doped diamond (BDD) working electrode, which is known to generate hydroxyl radicals at high potentials. The capability of the EC‐MS system to generate highly relevant oxidation products which also occur upon oxidative damage in vivo is demonstrated in this study by the formation of well known biomarkers for DNA damage, including 2′‐deoxy‐8‐oxo‐guanosine 5′‐monophosphate.  相似文献   

19.
This report provides detailed experimental results of thermal and surface characterization on untreated and surface‐treated halloysite nanotubes (HNTs) obtained from two geographic areas. Surface characterization techniques, including XPS and time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) were used. ToF‐SIMS surface analysis experiments were performed with both atomic and cluster ion beams. Higher ion yields and more high‐mass ions were obtained with the cluster ion beams. Static ToF‐SIMS spectra were analyzed with principal component analysis (PCA). Morphological diversities were observed in the samples although they mainly contained tubular structures. Thermogravimetric data indicated that aqueous hydrogen peroxide solution could remove inorganic salt impurities, such as alkali metal salts. The amount of grafting of benzalkonium chloride of HNT surface was determined by thermogravimetic analysis. PCA of ToF‐SIMS spectra could distinguish the samples mined from different geographical locations as well as among surface‐treated and untreated samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
We examine the potential for PTR‐TOF‐MS systems to quantitatively measure glyoxal in ambient air by characterizing the response of the instrument to a dilute glyoxal sample, calibrating the system as a function of humidity. The concentration of glyoxal in a sample air‐stream was measured with an UV absorption spectrometer in parallel to a PTR‐TOF‐MS. This calibration demonstrated that the PTR‐TOF‐MS has a relatively low sensitivity to glyoxal particularly at high humidity. Extensive fragmentation of glyoxal to formaldehyde was observed. This behaviour not only desensitizes PTR‐MS system to glyoxal; it may also pose a problem to the quantification of formaldehyde. © 2016 The Authors. Journal of Mass Spectrometry Published by John Wiley & Sons Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号