首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Static headspace sampling, headspace solid-phase microextraction, and direct immersion solid-phase microextraction coupled with gas chromatography–tandem mass spectrometry have been developed for determination of the volatile components in Radix bupleuri injection. A total of 78 compounds were identified from Radix bupleuri injection. Direct immersion solid-phase microextraction gave a better extraction efficiency for polar compounds, including organic acids and alcohols, than headspace solid-phase microextraction or static headspace sampling. Product ion isotope pattern analysis was applied to determine the elemental composition of the precursor ion, which could make the qualitative analysis more accurate and reliable.  相似文献   

2.
This research paper presents a comparative study of two different extraction and concentration techniques to obtain representative pistachio aroma extracts: the traditional direct solvent extraction (DSE) followed by high-vacuum transfer (HVT) and the headspace solid-phase microextraction (HS-SPME). The results showed that, although both techniques provide accurate information about the aromatic composition that will be perceived by the consumer, the precision in terms of within-day repeatability and between-days repeatability (intermediate precision) of the chromatographic areas presented better values for HS-SPME than for DSE-HVT. Moreover the solvent-free HS-SPME allows the extraction of more odour-active regions, requires very little sample handling and shorter time for sampling.  相似文献   

3.
A method for the determination of 15 aromatic hydrocarbons in eluates from solid residues produced during the co-pyrolysis of plastics and pine biomass was developed. In a first step, several sampling techniques (headspace solid phase microextraction (HS-SPME), static headspace sampling (HS), and dispersive liquid-liquid microextraction (DLLME) were compared in order to evaluate their sensitivity towards these analytes. HS-SPME and HS sampling had the better performance, but DLLME was itself as a technique able to extract volatiles with a significant enrichment factor.HS sampling coupled with GC-MS was chosen for method validation for the analytes tested. Calibration curves were constructed for each analyte with correlation coefficients higher than 0.999. The limits of detection were in the range of 0.66-37.85 ng/L. The precision of the HS method was evaluated and good repeatability was achieved with relative standard deviations of 4.8-13.2%. The recoveries of the analytes were evaluated by analysing fortified real eluate samples and were in the range of 60.6-113.9%.The validated method was applied in real eluate samples. Benzene, toluene, ethylbenzene and xylenes (BTEX) were the compounds in higher concentrations.The DLLME technique coupled with GC-MS was used to investigate the presence of less volatile contaminants in eluate samples. This analysis revealed the presence of significant amounts of alkyl phenols and other aromatic compounds with appreciable water solubility.  相似文献   

4.
This paper describes the optimization of solid-phase microextraction (SPME) conditions for three different fibres (Carboxen-polydimethylsiloxane (CAR-PDMS), divinylbenzene-Carboxen-polydimethylsiloxane (DVB-CAR-PDMS) and polydimethylsiloxane-divinylbenzene (PDMS-DVB)) used to determine trihalomethanes (THMs) in water by headspace solid-phase microextraction and gas chromatography (HS-SPME-GC). The influence of temperature and salting-out effect was examined using a central composite design for each fibre. Extraction time was studied separately at the optimum values found for temperature and sodium chloride concentration (40 degrees C and 0.36g mL-1). The HS-SPME-GC-MS method for each fibre was characterised in terms of linearity, detection (LOD) and quantification (LOQ) limits and repeatability. The fibre PDMS-DVB was selected as it provided a broader linear range, better repeatability and lower detection and quantification limits than the others, particularly CAR-PDMS fibre. The accuracy of the proposed method using the PDMS-DVB fibre was checked by a recovery study in both ultrapure and tap water. A blank analysis study showed the absence of memory effects for this fibre. The reproducibility (expressed as a percentage of relative standard deviation) was 6-11% and the detection limits were between 0.078 and 0.52microgL-1 for bromoform and chloroform, respectively. Finally, the method was applied to determine THM concentration in two drinking water samples.  相似文献   

5.
《Analytical letters》2012,45(4):654-674
Jujube extract has a unique flavor that has been used as a common fragrance due to the volatile compounds. In this study, the volatiles of jujube extract were isolated by liquid–liquid extraction, simultaneous distillation extraction, ultrasound-assisted solvent extraction, and headspace solid-phase microextraction, and analyzed by gas chromatography–mass spectrometry. Altogether 92 compounds were identified by the four methods, of which 53 components were identified for the first time; however, only 21 compounds were identified by all these methods. The performance characteristics of the four pretreatment techniques were compared by principal component analysis which showed that the volatile compounds obtained by liquid–liquid extraction and ultrasound-assisted solvent extraction were similar both in categories and in content; whereas, the volatiles extracted by simultaneous distillation extraction, ultrasound-assisted solvent extraction, and headspace solid-phase microextraction greatly varied. The results indicated that a multi-pretreatment technique should be adopted in order to obtain the most complete information about the volatile compounds in jujube extract. The ultrasound-assisted solvent extraction method exhibited excellent repeatability and recoveries, and was very suitable for quantitative analysis. Although the recoveries and reproducibility of headspace solid-phase microextraction were inferior to the other methods, it was more sensitive than other methods.  相似文献   

6.
The theory of multiple headspace solid-phase microextraction (HS-SPME) and a method based on multiple HS-SPME for the quantitative determination of volatile organic compounds (VOCs) in packaging materials is presented. The method allows the direct analysis of solid samples without using organic solvents to extract analytes. Multiple headspace solid-phase microextraction is a stepwise method proposed to eliminate the influence of the sample matrix on the quantitative analysis of solid samples by HS-SPME. Different amounts of packaging and different volumes of standard solution were studied in order to remove a substantial quantity of analytes from the headspace at each extraction and obtain the theoretical exponential decay of the peak area of the four successive extractions and, thus, the total area was calculated from these four extractions. In addition, two fibres were compared: carboxen-polydimethylsiloxane (CAR-PDMS) and divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS), as they showed differences in the linearity of the exponential decay with the number of extractions depending on the compound. The CAR-PDMS fibre was better for the VOCs with a low molecular mass, whereas the DVB-CAR-PDMS fibre was better for the VOCs with a high molecular mass. Finally, the method was characterised in terms of linearity, detection limit and reproducibility and applied to analyse four multilayer packaging samples with different VOCs contents.  相似文献   

7.
Triacetone triperoxide (TATP) is a high explosive synthesized from easily available reactants making it accessible for illicit uses. In this study, fast detection of TATP is achieved using a novel planar solid-phase microextraction (PSPME) as a preconcentration and sampling device for headspace analysis offering improved sensitivity and reduced sampling time over the conventional fiber-based solid-phase microextraction (SPME) when followed by ion mobility spectrometer (IMS) detection. Quantitation and comparison of the retention capabilities of PSPME as compared to the commercially available SPME were determined using TATP standards and analyzed using gas chromatography–mass spectrometry for SPME analysis and a commercial IMS with no instrumental modification for PSPME. Static and dynamic headspace extractions were used and compared for PSPME extractions, in which low milligram quantities of TATP were detected within 30 s of static mode sampling and less than 5 s in the dynamic mode sampling for PSPME–IMS.  相似文献   

8.
A rapid and simple method of using solid-phase microextraction was developed for determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) in water samples. In this method, the target analyte is extracted from the sample into the polymeric coating of the fused-silica fiber. After exposure, the fiber is thermally desorbed in the heated injection port of the gas chromatograph, and a chromatographic analysis is performed by using low-resolution tandem mass spectrometry. Parameters that may affect the extension of the microextraction process, such as sampling mode, sample volume, temperature, agitation, and sampling time, were studied. Extraction efficiencies for 3 coating fibers were investigated: 100 microm poly(dimethylsiloxane) (PDMS), 65 microm PDMS-divinylbenzene, and 75 microm carboxen-PDMS. Linearity was evaluated (R = 0.999) for a 250-fold concentration range from the fg/mL to the pg/mL level. The 2,3,7,8-TCDD was detected at the fg/mL level when the headspace over the water sample was sampled for 60 min; the limit of detection obtained was better than that of Method 8280B of the U.S. Environmental Protection Agency. The proposed method performed well when applied to the analysis of tap water, lake water, and seawater samples.  相似文献   

9.
Headspace solid-phase microextraction has been applied to the analysis of volatile phenols in wine. Silica fibre coated with Carbowax-divinylbenzene was found to be more efficient at extracting these compounds than other fibres such as those coated with polydimethylsiloxane, polyacrylate, carboxen-polydimethylsiloxane, and polydimethylsiloxane-divinylbenzene. Different parameters such as extraction time, temperature of the sample during the extraction, ionic strength and sample volume were optimised using a two-level factorial design expanded further to a central composite design, in order to evaluate several possibly influential and/or interacting factors. The headspace (HS)-SPME procedure developed shows adequate detection and quantitation limits, and linear ranges for correctly analysing these compounds in wine. The recoveries obtained were close to 100%, with repeatability values lower than 16%. The method was applied to a variety of white and red wines.  相似文献   

10.
A new headspace solid-phase microextraction (HSSPME) procedure carried out under vacuum conditions is proposed here where sample volumes commonly used in HSSPME (9 mL) were introduced into pre-evacuated commercially available large sampling chambers (1000 mL) prior to HSSPME sampling. The proposed procedure ensured reproducible conditions for HSSPME and excluded the possibility of analyte losses. A theoretical model was formulated demonstrating for the first time the pressure dependence of HSSPME sampling procedure under non equilibrium conditions. Although reduced pressure conditions during HSSPME sampling are not expected to increase the amount of analytes extracted at equilibrium, they greatly increase extraction rates compared to HSSPME under atmospheric pressure due to the enhancement of evaporation rates in the presence of an air-evacuated headspace. The effect is larger for semivolatiles whose evaporation rates are controlled by mass transfer resistance in the thin gas film adjacent to the sample/headspace interface. Parameters that affect HSSPME extraction were investigated under both vacuum and atmospheric conditions and the experimental data obtained were used to discuss and verify the theory. The use of an excessively large headspace volume was also considered. The applicability of Vac-HSSPME was assessed using chlorophenols as model compounds yielding linearities better than 0.9915 and detection limits in the low-ppt level. The repeatability was found to vary from 3.1 to 8.6%.  相似文献   

11.
High concentration capacity headspace techniques (headspace solid-phase microextraction (HS-SPME) and headspace sorptive extraction (HSSE)) are a bridge between static and dynamic headspace, since they give high concentration factors as does dynamic headspace (D-HS), and are as easy to apply and as reproducible as static headspace (S-HS). In 2000, Chromtech (Idstein, Germany) introduced an inside-needle technique for vapour and liquid sampling, solid-phase dynamic extraction (SPDE), also known as "the magic needle". In SPDE, analytes are concentrated on a 50 microm film of polydimethylsiloxane (PDMS) and activated carbon (10%) coated onto the inside wall of the stainless steel needle (5 cm) of a 2.5 ml gas tight syringe. When SPDE is used for headspace sampling (HS-SPDE), a fixed volume of the headspace of the sample under investigation is sucked up an appropriate number of times with the gas tight syringe and an analyte amount suitable for a reliable GC or GC-MS analysis accumulates in the polymer coating the needle wall. This article describes the preliminary results of both a study on the optimisation of sampling parameters conditioning HS-SPDE recovery, through the analysis of a standard mixture of highly volatile compounds (beta-pinene, isoamyl acetate and linalool) and of the HS-SPDE-GC-MS analyses of aromatic plants and food matrices. This study shows that HS-SPDE is a successful technique for HS-sampling with high concentration capability, good repeatability and intermediate precision, also when it is compared to HS-SPME.  相似文献   

12.
A solid-phase microextraction method (SPME) for determining trace levels of synthetic musk fragrances in residual waters has been developed. Six polycyclic musks (cashmeran, phantolide, celestolide, traseolide, galaxolide and tonalide), and a macrocyclic musk (ambrettolide) have been analysed. A detailed study of the different parameters affecting the extraction process is presented. The main important factors affecting the microextraction process have been studied and optimised by means of a categorical factorial design. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using four different fiber coatings [polydimethylsiloxane (PDMS), Carboxen (CAR)-PDMS, PDMS-divinylbenzene (DVB) and Carbowax (CW)-DVB]. An extraction temperature of 100 degrees C sampling the headspace over the sample using CAR-PDMS or PDMS-DVB as fiber coatings were found to be the experimental conditions that lead to a more effective extraction. The method proposed is very simple and yields high sensitivity, with detection limits in the low pg/ml, good linearity and repeatability for all the target compounds. The total analysis time, including extraction and GC analysis, was only 45 min. The optimised method performed well when it was applied to waste water from an urban treatment plant.  相似文献   

13.
Headspace solid-phase microextraction, followed by GC-MS analysis is presented as a suitable technique for the determination of musk compounds in sewage treatment plant sludge. Five polycyclic musks (celestolide, phantolide, traseolide, galaxolide and tonalide) and four nitro musks (musk xylene, musk moskene, musk tibetene and musk ketone) were considered in the optimisation of the analytical method. The influence of extraction temperature, fibre coating, agitation, pH and salting out on the efficiency of the extraction along with the extraction kinetics were studied. An extraction temperature of 100 degrees C and sampling the headspace over the stirred sludge sample using polydimethylsiloxane -divinylbenzene as fibre coating lead to effective extraction. The method proposed is very simple and yields high sensitivity, good linearity and repeatability for all the analytes with limits of detection at the sub-ng/g level. The total analysis time, including extraction and GC analysis, was only 40 min, and no manipulation of the sample was required.  相似文献   

14.
The present work investigates the applicability of solid-phase microextraction coupled to gas-chromatography mass-spectrometry for the determination of trace amounts of nitropolycyclic aromatic hydrocarbons in water samples. The main parameters affecting solid-phase microextraction (sampling mode, fibre type, sampling time, agitation rate and ionic strength of the aqueous solution) were controlled and the optimal experimental conditions found were: 65-μm polydimethylsiloxane-divinylbenzene fibre immersed for 45 min to 5 mL spiked water samples, stirred at 1250 rpm. The developed solid-phase microextraction method was found to be linear in the concentration range 0.1 to 10 μg L−1, with the detection limits ranging between 0.004 and 0.060 μg L−1 (under the selective ion monitoring mode) and the repeatability varying between 1.7 and 5.9% (n=5). Analysis of spiked tap and well water samples revealed that matrix had little effect on extraction. Overall, it was found that solid-phase microextraction is suitable for the trace analysis of nitropolycyclic aromatic hydrocarbons in water samples. Revised: 14 October and 14 November 2005  相似文献   

15.
Three approaches based on headspace single-drop microextraction (HS-SDME), direct single-drop microextraction (Direct-SDME), and headspace solid-phase microextraction (HS-SPME), have been compared for analyzing volatile sulphur compounds (VSCs) in beer and beverage. Procedures and performance of the three methods have been contrasted through the determination of extraction efficiencies, precision, linearity and limits of detection. The overall process of HS-SDME and HS-SPME was applied to GC-FPD determination of five VSCs in beer and beverage.  相似文献   

16.
In this work, a novel technique of aqueous-phase derivatization followed by headspace solid-phase microextraction and gas chromatography-mass spectrometry was developed for the determination of organic acids in urine. The analytical procedure involves derivatization of organic acids to their ethyl esters with diethyl sulfate, headspace sampling, and GC/MS analysis. The proposed method was applied to the determination of methylmalonic acid and glutaric acid in urine. The experimental parameters and method validation were studied. Optimal conditions were obtained: PDMS fiber, extraction temperature 55 degrees C, extraction time 30 min, and 60 microL of diethyl sulfate as derivatization reagent with 2 mg of the ion pairing agent tetrabutylammonium hydrogensulfate. The method was linear over three orders of magnitude, and detection limits were 21 nM for methylmalonic acid and 34 nM for glutaric acid, respectively. Consequently, in-situ derivatization/HS-SPME/GC/MS is an alternative and powerful method for determination of organic acids as biomarkers in biological fluids.  相似文献   

17.
建立了采用75μm碳分子筛/聚二甲基硅氧烷(CAR-PDMS)纤维的固相微萃取-气相色谱/同位素质谱联用方法测定水中挥发性有机污染物碳同位素。使用浸入式固相微萃取和顶空固相微萃取方法进行实验确定在低浓度条件下最佳δ13C测试方法。通过使用顶空固相微萃取前处理技术进行单体同位素分析分析灵敏度更高,应用CSIA技术对1,2-二氯乙烯,三氯乙烯,四氯化碳进行单体同位素分析,方法的检出限为70μg/L,与样本的标准偏差小于0.3‰。该法适用于水体中微量挥发性有机污染物的同位素组成测定。  相似文献   

18.
The efficiency of headspace solid-phase microextraction (SPME) was evaluated for the qualitative and semi-quantitative analysis of virgin olive oil volatile compounds. The behaviour of four fibre coatings was compared for sensitivity, repeatability and linearity of response. A divinylbenzene-Carboxen-polydimethylsiloxane fibre coating was found to be the most suitable for the analysis of virgin olive oil volatiles. Sampling and chromatographic conditions were examined and the SPME method, coupled to GC with MS and flame ionization detection, was applied to virgin olive oil samples. More than 100 compounds were isolated and characterised. The presence of some of these compounds in virgin olive oil has not previously been reported. The main volatile compounds present in the oil samples were determined quantitatively.  相似文献   

19.
A method for the determination of volatile organic compounds (VOCs) in recycled polyethylene terephthalate and high-density polyethylene using headspace sampling by solid-phase microextraction and gas chromatography coupled to mass spectrometry detection is presented. This method was used to evaluate the efficiency of cleaning processes for VOC removal from recycled PET. In addition, the method was also employed to evaluate the level of VOC contamination in multilayer packaging material containing recycled HDPE material. The optimisation of the extraction procedure for volatile compounds was performed and the best extraction conditions were found using a 75 μm carboxen-polydimethylsiloxane (CAR-PDMS) fibre for 20 min at 60 °C. The validation parameters for the established method were linear range, linearity, sensitivity, precision (repeatability), accuracy (recovery) and detection and quantification limits. The results indicated that the method could easily be used in quality control for the production of recycled PET and HDPE.  相似文献   

20.
A method was developed for the determination of C1-C6 carbonyl compounds in alcoholic solutions using pentafluorobenzoxymation followed by headspace sampling solid-phase microextraction and subsequent analysis by GC with electron-capture detection. Experimental conditions-alcohol content, exposure time, temperature and sample agitation were optimised. In this method, a spirit or distilled alcoholic beverage is first adjusted to 20% (v/v) alcohol. Detection limits for particular aldehydes and ketone varied from 0.05 to 0.5 microg/l and relative standard deviation was between 2.3 and 20%. Generally, the method showed good linearity for the tested concentration range 8 microg/l-0.32 mg/l with regression coefficients ranging between 0.9434 and 0.9983. The method was applied to the analysis of real alcoholic beverages (vodkas).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号