首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
曹蕾  张耀锋  杨扬  黄建微  张晓乐 《强激光与粒子束》2022,34(2):026005-1-026005-8
为了更好地进行环境X/γ辐射剂量的测量,通过对电制冷高纯锗探测器蒙特卡罗建模获取0.01~1.5 MeV能量范围内的能谱和剂量(率)值,并利用无卷积全谱转换法进行能谱-剂量转换研究。研究发现,通过无卷积全谱转换法计算得到的剂量率与模拟剂量率符合较好;通过在中国计量研究院环境γ辐射空气吸收剂量标准辐射场中进行Co-60和Cs-137放射源剂量率实验验证,结果显示,在0.01~1.5 MeV的能量范围内,通过能谱-剂量转换得到剂量率与标准剂量率的误差小于±10%,这表明通过无卷积全谱转换法进行能谱-剂量(率)转换系数的求解是可行的。  相似文献   

2.
TLD efficiency of 7LiF for doses deposited by high-LET particles.   总被引:2,自引:0,他引:2  
The efficiency of 7 LiF TLDs (TLD-700) in registering dose from high-LET (> or = 10 keV/micrometers) charged particles (relative to 137Cs gamma rays) has been measured for a number of accelerated heavy ions at various particle accelerator facilities. These measured efficiency values have been compared with similar results obtained from the open literature and a dose efficiency function has been fitted to the combined data set. While it was found that the dose efficiency is not only a function of LET, but also of the charge of the incident particle, the fitted function can be used to correct the undermeasured value of dose from exposures made in mixed radiation fields where LET information is available. This LET-dependent dose efficiency function is used in our laboratory in determining total absorbed dose and dose equivalent from combined TLD and CR-39 plastic nuclear track detector measurements.  相似文献   

3.
红外光谱辐射计探测器高阶非线性响应校正方法   总被引:1,自引:0,他引:1       下载免费PDF全文
针对傅里叶变换红外光谱辐射计辐射定标需要黑体辐射面充满仪器视场的技术特点,分析了由于入射光子流较高导致红外探测器产生非线性响应误差的机理.通过仿真包含非线性误差的黑体辐射数据,研究了非线性误差对光谱产生的影响,并根据卷积和交叉迭代两种校正方法,提出了适合校正高阶非线性响应误差的迭代方法—梯度下降法.利用傅里叶变换红外光谱辐射计进行辐射定标实验,对比卷积、交叉迭代和梯度下降法三种校正方法的效果,结果显示三种校正方法均可有效减小非线性误差,分别使拟合优度提高了0.15%,0.29%和0.39%,梯度下降法校正后的光谱数据更为准确.  相似文献   

4.
A simple and inexpensive twin-type airflow pulse ionization chamber was developed for the continuous monitoring of alpha-radioactivity in atmosphere under high humidity condition. The symmetrical structure of the twin-type ionization chamber was effective in the improvement of the ratio of signal to noise in the measurement of pulses induced by alpha-rays. Outdoor alpha-ray measurement was well performed with this ionization chamber by applying sufficiently high bias voltage to the electrodes, except for at very high humidity conditions. It was confirmed that the declination of the counting efficiency due to wetting was easily recovered by the dry-up of the inside of the chamber. Alpha-radioactivity from radon and other alpha-emitting radionuclide in atmosphere was satisfactorily monitored by the detector.  相似文献   

5.
Solid State Nuclear Track Detectors (SSNTD) are commonly used for long term measurements of radon, thoron and progeny concentrations. In the present study, we compared the optical counting method and the spark counting technique for counting the alpha tracks on LR 115 track detector films. The paper discusses the various parameters that are innate in the process. More than 300 films were counted by both optical microscope and spark counter and the results are compared. The overall results show that the tracks obtained by spark counting are marginally less compared to the optical measurement. A linear fit of the data gives a slope less that one, which indicates that both the methods are almost in good agreement for counting the tracks when the track density is low. At higher track densities the spark counter gives an underestimation with respect to actual number of tracks formed, which could be corrected using a relation obtained between the tracks measured by optical method and spark counting.   相似文献   

6.
In view of the fact that the radon progeny contribute the highest to the natural radiation dose to general populations, large scale and long-term measurements of radon and its progeny in the houses have been receiving considerable attention. Solid State Nuclear Track Detector (SSNTD) based systems, being the best suited for large scale passive monitoring, have been widely used for the radon gas (using a cup closed with a semi-permeable membrane) and to a limited extent, for the measurement of radon progeny (using bare mode in conjunction with the cup). These have been employed for radon mapping and indoor radon epidemiological studies with good results. In this technique, alpha tracks recorded on SSNTD films are converted to radon/thoron concentrations using corresponding conversion factors obtained from calibration experiments carried out in controlled environments. The detector response to alpha particles depends mainly on the registration efficiency of the alpha tracks on the detector films and the subsequent counting efficiency. While the former depends on the exposure design, the latter depends on the protocols followed for developing and counting of the tracks. The paper discusses on parameters like etchant temperature, stirring of the etchant and duration of etching and their influence on the etching rates on LR-115 films. Concept of break down thickness of the SSNTD film in spark counting technique is discussed with experimental results. Error estimates on measurement results as a function of background tracks of the films are also discussed in the paper.   相似文献   

7.
朱剑钰  黄孟  赵德山 《强激光与粒子束》2022,34(2):026015-1-026015-6
主动中子多重性计数测量方法是常用的核材料质量无损测量方法,已广泛应用于核材料衡算、核安保测量与军控核查等领域。我们通过对JMCT中子-光子输运程序的二次开发,实现了对经典点模型铀样品质量估算实验的数值模拟,并提出了改进的铀样品质量计算公式。该算法可以显著降低本实验中源-样品耦合与源中子反照等作用对铀样品质量估算精度的影响。建立了主动中子多重性计数测量探测系统模型和32个铀样品半球壳模型,模拟得到了与铀样品距离不同的DT源和AmLi源主动中子多重性计数,利用数值模拟手段检验了质量估算算法的有效性。数值模拟结果表明,改进的铀质量估算算法可以使质量估算的平均偏差率降低到10%以下。  相似文献   

8.
An experimental calibration of two common nuclear track detectors, CR-39 and Lexan, for gamma and electrons radiation, was performed using various irradiation facilities. The dose response was obtained as a function of two parameters, the bulk etch rate and the UV absorbance for a wide dose range from 10 to 1000 kGy. The bulk etch rate sensitivity, for gamma and electrons, in CR-39 detector is higher than for Lexan detector. Lexan has a well-defined UV absorbance spectrum, but presents saturation for doses higher than 500 kGy, the same saturation characteristic is observed for the corresponding bulk etch rate response. For electron and gamma radiation, CR-39 shows a good response for doses from 10 kGy up to 1000 kGy, where data fit well an exponential curve for electrons and a lineal curve for gamma radiation.  相似文献   

9.
Historical beeswax seals are unique cultural heritage objects. Unfortunately, a number of historical sealing waxes show a porous structure with a strong tendency to stratification and embrittlement, which makes these objects extremely prone to mechanical damage. The understanding of beeswax degradation processes therefore plays an important role in the preservation and consequent treatment of these objects. Conventional methods applied for the investigation of beeswax materials (e.g. gas chromatography) are of a destructive nature or bring only limited information about the sample surface (microscopic techniques). Considering practical limitations of conventional methods and ethical difficulties connected with the sampling of the historical material, radiation imaging methods such as X-ray micro-tomography presents a promising non-destructive tool for the onward scientific research in this field. In this contribution, we present the application of high-contrast X-ray micro-radiography and micro-tomography for the investigation of beeswax seal fragments. The method is based on the application of the large area photon-counting detector recently developed at our institute. The detector combines the advantages of single-photon counting technology with a large field of view. The method, consequently, enables imaging of relatively large objects with high geometrical magnification. In the reconstructed micro-tomographies of investigated historical beeswax seals, we are able to reveal morphological structures such as stratification, micro-cavities and micro-fractures with spatial resolution down to 5 μm non-destructively and with high imaging quality. The presented work therefore demonstrates that a combination of state-of-the-art hybrid pixel semiconductor detectors and currently available micro-focus x-ray sources makes it possible to apply X-ray micro-radiography and micro-tomography as a valuable non-destructive tool for volumetric beeswax seal morphological studies.  相似文献   

10.
N L MISRA 《Pramana》2011,76(2):201-212
Nuclear energy is one of the clean options of electricity generation for the betterment of human life. India has an ambitious program for such electricity generation using different types of nuclear reactors. The safe and efficient generation of electricity from these reactors requires quality control of different nuclear materials, e.g. nuclear fuel, structural materials, coolant, moderators etc. These nuclear materials have to undergo strict quality control and should have different specified parameters for their use in nuclear reactors. The concentration of major and trace elements present in these materials should be within specified limits. For such chemical quality control of these materials, major and trace elemental analytical techniques are required. Since some of these materials are radioactive, the ideal chemical characterization techniques should have multielement analytical capability, should require very less sample (micrograms level) for analysis so that the radioactive waste generated, and radiation exposure to the detector and operator are minimum. Total reflection X-ray fluorescence (TXRF) and energy dispersive X-ray fluorescence (EDXRF) with improved features, e.g. application of filters, secondary target and instrumental geometry require very small amount of sample and thus can be suitably used for the characterization of nuclear materials mainly for the determination of elements at trace and major concentration levels. In Fuel Chemistry Division, TXRF analytical methods have been developed for trace element determinations in uranium and thorium oxides, chlorine determination in nuclear fuel and cladding materials, sulphur in uranium, uranium in sea water etc. Similarly, EDXRF analytical methods with radiation filters (to reduce background) and improved sample preapartion techniques, e.g. fusion bead and taking samples in the form of solution on filter papers have been used for developing analytical methods for the determination of U and Th in their mixed matrices, Cd in uranium etc. Some of these studies have been reported in this paper.  相似文献   

11.
The effect of collimation to the alpha-particle energy spectra was investigated for two different types of air filters, when the measurements were performed at ambient air pressure. Significant improvement of the energy resolution is possible if appropriate collimator is used. This is because only those alpha particles are detected entering the detector almost perpendicularly. We also show that although in-situ alpha spectrometry from air filters at ambient air pressure and with good energy resolution is possible, the accumulation of alpha-particle emitting aerosols in the surface of the collimator and the detector may deteriorate the registered spectrum. Therefore, the presence of possible spurious alpha peaks must be taken into account in continuous air monitoring.  相似文献   

12.
利用Nal闪烁谱仪测量了在探测器与放射源间某个距离下对应的计数率.对测量的数据分别利用等精度最小二乘法和未知参数逼近法进行了处理,观察到在某些未知参数下,最小二乘法引起的误差很大,利用未知参数逼近法得到的值能和真实值较好接近,从而验证了辐射强度与距离平方反比率.  相似文献   

13.
针对放射源搜寻过程中难度大、定位精度低等问题,提出了一种适用于移动机器人的自主寻源方法。该方法利用移动机器人搭载辐射探测器采集的剂量计数值,根据γ射线的衰减规律建立辐射衰减模型;在机器人前进的过程中利用粒子滤波算法对放射源的参数进行实时估计;采用高斯分布函数对重采样后的粒子进行自适应更新,保证重采样后的粒子具有多样性;根据辐射环境创建机器人路径规划模型,采用人工势场法规划机器人的自主寻源路径。实验在Matlab下进行了仿真验证,结果表明,该方法在有遮挡环境下能够搜寻到未知的单点源,同时自适应更新能够提高算法的稳定性,缩小寻源误差。  相似文献   

14.
Silicon photodetectors and MOSFETs (Metal-Oxide-Semiconductor Field Effect Transistors) are frequently used devices for measuring ionizing radiation in health physics instrumentation. The Bipolar Junction Transistor (BJT) is not a typical device used as a detector for measuring some physical quantities in radiotherapy beams due to its loss of sensitivity to ionizing radiation, as a consequence of radiation damage in the silicon semiconductor substrate. Actually, the know-how of the BJT characteristic curves and its response to ionizing radiation leads us to suggest an alternative method to estimate the radiation dose value in breast cancer treatments. The BJT parameter to be evaluated before and after the irradiation procedure is the BJT amplification factor, also called DC gain β. In this work, the study was done using a BJT known as Darlington type, within an Alderson Rando anthropomorphic phantom. Darlington transistors have very high gain and this feature allowed that the BJT gain changes to be correlated with the dose of the radiation beam. The results indicate that this new method could be an alternative option to estimate the dose value in the phantom for measurements in breast cancer radiotherapy.  相似文献   

15.
A semiclassical correction to the alpha-decay rate in an alternating electromagnetic field is obtained. Single-particle Gamow theory is used to describe the alpha-decay process. The relative change in the alpha-decay rate is calculated as a function of the charge of the alpha-active nucleus being considered, the alpha-particle energy, and the laser-radiation intensity. It is shown that the lower the alpha-particle energy and the larger the charge-number value, the greater the increase in the alpha-decay rate. It is found that, even at the liming values of the laser-radiation intensity (1026–1028 W/cm2), the relative enhancement of alpha decay does exceed a few percent—in particular, it is as small as 2% for 238U at the radiation intensity of 1028 W/cm2.  相似文献   

16.
Measurements of the radiation environment inside the Mir space station were performed with a tissue equivalent proportional counter (TEPC) during the Antares mission in 1992, and over a long period following it. Interesting results concerning radiation measurements show (a) the South Atlantic Anomaly crossing, (b) the increase of radiation near the poles, and (c) the effects of solar particle events (the most important one occurring in early November 1992). This data also provides information about the dose and the quality factor of the radiation to which the cosmonauts were exposed during different missions. These data are compared with measurements obtained using a solid state detector.  相似文献   

17.
周尊源 《应用光学》1991,12(2):24-26,12
美国自适应光学联合公司(AOA)在哈佛大学 PAPA 探测器的基础上研制成功的光子数字化编址摄象机是一种具有极高探测灵敏度的光子计数式二维微光摄象机。采用多通道光学编码方法,可对光电倍增管探测到的每一个光电于事件产生相应的(x,y,T)时-空坐标数据,微机采集来自光子摄象机的数据流供实时图象显示和处理。  相似文献   

18.
中国散裂中子源( CSNS ) 的建造对中子探测器提出了非常高的要求,如更大的有效面积、二维位置灵敏、高计数率、高探测效率和低的 灵敏度等。与传统的模拟读出方法相比,数字法读出具有更高的计数率, 更小的数据传输量,更简单的电子学设计以及更高的信噪比。对数字法读出进行了理论计算,利用GEM探测器的原始数据分析了数字法读出的位置分辨率与读出条宽度的关系。结果表明,数字法读出对于位置分辨要求较低( 小于4 mm) 的大面积位置灵敏探测器是一种较好的选择,如CSNS 小角谱仪探测器。Efficient thermal neutron detectors with large area, two-dimensional position sensitive, high counting rate high detection efficiency and low gamma sensitivity are required to satisfy the demands for the China Spallation Neutron Source (CSNS). Compared with the traditional analog readout method, the digital readout method has the advantages of higher counting rate, smaller quantity of data transmission, simpler readout system and higher signal to noise ratio. The theoretical analysis of the digital readout method is reported in this paper. Used the raw data of GEM detector, the relationship between the position resolution and the width of the readout strip was studied. The results indicate that the digital readout method could be a good choice for the large area position sensitive detector where the requirement of position resolution is less than 4 mm, e.g. the detector of Small-Angle Neutron Scattering (SANS) diffractometer of CSNS.  相似文献   

19.
以SiC二极管和中子转换材料6LiF为基础,研制了SiC基中子探测器,并用241Am源与临界装置分别研究了SiC基中子探测器的粒子响应、热中子响应。结果表明:SiC基中子探测器能够满足241Am源粒子的计数测量,但由于SiC二极管灵敏区薄,故不能用于5.48 MeV的粒子能谱测量;SiC基中子探测器对热中子响应良好,不同功率下,脉冲幅度谱中可清晰看到由6Li(n,)3H的反应产物粒子、3H粒子形成的双峰;脉冲幅度甄别法可将射线及电子学噪声甄别掉;在直接测量与符合测量中,SiC基中子探测器的计数率均与临界装置功率成线性关系,且直接测量的线性度比符合测量的线性度好,最好可达0.999 97。研究表明:降低肖特基接触金属的厚度、增加其外延层厚度、提高其外延层品质,可将SiC二极管用于带电粒子能谱测量。  相似文献   

20.
The fission track technique was applied to the particle analysis for safeguards environmental samples to obtain information about the isotope ratio of nuclear materials in individual particles. To detect the particles containing nuclear material with high detection efficiency and less particle loss, the influence of uranium enrichments on etching conditions of a fission track detector made of polycarbonate was investigated. It was shown that the increase in uranium enrichment shortened the suitable etching time both for particle detection and for less particle loss. From the results obtained, it was suggested that the screening of the uranium particles according to the enrichment is possible by controlling the etching time of the detector.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号