共查询到20条相似文献,搜索用时 122 毫秒
1.
Hwi Yong Lee Cedrick Barber Jessika A. Rogers Adrienne R. Minerick 《Electrophoresis》2015,36(7-8):978-985
Hematocrit (HCT) tests are widely performed to screen blood donors and to diagnose medical conditions. Current HCT test methods include conventional microhematocrit, Coulter counter, CuSO4 specific gravity, and conductivity‐based point‐of‐care (POC) HCT devices, which can be either expensive, environmentally inadvisable, or complicated. In the present work, we introduce a new and simple microfluidic system for a POC HCT determination. HCT was determined by measuring current responses of blood under 100 V DC for 1 min in a microfluidic device containing a single microchannel with dimensions of 180 μm by 70 μm and 10 mm long. Current responses of red blood cell (RBC) suspensions in PBS or separately plasma at HCT concentrations of 10, 20, 25, 30, 35, 40, 45, 50, 55, 60, and 70 vol% were measured to show feasibility of the microfluidic system for HCT determination. Key parameters affecting current responses included electrolysis bubbles and irreversible RBC adsorption; parameters were optimized via addition of nonionic surfactant Triton X‐100 into sample solution and carbonizing electrode surfaces. The linear trend line of current responses over a range of RBC concentrations were obtained in both PBS and plasma. This work suggested that a simple microfluidic device could be a promising platform for a new POC HCT device. 相似文献
2.
A novel electrochemical method with a microfluidic device was developed for analysis of single cells. In this method, cell injection, loading and cell lysis, and electrokinetic transportation and detection of intracellular species were integrated in a microfluidic chip with a double-T injector coupled with an end-channel amperometric detector. A single cell was loaded at the double-T injector on the microfluidic chip by using electric field. Then, the docked cell was lysed by a direct current electric field strength of 220 V/cm. The analyte of interest inside the cell was electrokinetically transported to the detection end of separation channel and was electrochemically detected. External standardization was used to quantify the analyte of interest in individual cells. Ascorbic acid (AA) in single wheat callus cells was chosen as the model compound. AA could be directly detected at a carbon fiber disk bundle electrode. The selectivity of electrochemical detection made the electropherogram simple. The technique described here could, in principle, be applied to a variety of electroactive species within single cells. 相似文献
3.
A high-throughput, simple, fast, low-cost and sensitive paper-based electrochemical immunodevice has been demonstrated based on a functionalized 3D paper-based device for point-of-care diagnosis. 相似文献
4.
In this study, multilayers from polyethylene imine, heparin and chitosan are prepared at three different pH values of 5, 7 and 9. Water contact angle and quartz microbalance measurements show that resulting multilayers differ in terms of wetting behaviour, layer mass and mechanical properties. The multilayer is then formed within a gradient generation microfluidic (μFL) device. Polyethylene imine or heparin solutions of pH 5 are introduced into one inlet and the same solutions but at pH 9 into another inlet of the μFL device. The pH gradient established during the multilayer formation can be visualized inside the microchamber by pH sensitive fluorophores and confocal laser scanning microscopy. From this setup it is expected that properties of multilayers displayed at distinct pH values can be realised in a gradient manner inside the μFL device. Behaviour of the osteoblast cell line MG-63 seeded and cultured on top of multilayers created inside the μFL device support this hypothesis. It is observed that more cells adhere and spread on multilayers build-up at the basic side of the μFL channel, while those cells on top of multilayers built at pH 5 are fewer and smaller. These results are consistent with the behaviour of MG-63 cells seeded on multilayers formed at discrete pH values. It is particularly interesting to see that cells start to migrate from multilayers built at pH 5 to those built at pH 9 during 6 h of culture. Overall, the presented multilayer formation setup applying pH gradients leads to surfaces that promote migration of cells. 相似文献
5.
Recently there has been concern regarding the use of flunitrazepam and other low-dose benzodiazepines in drug-facilitated sexual assault. These compounds are placed in drinks of unsuspecting victims and produce a sedative effect with anterorgrade amnesia. Chip-based microfluidic systems can provide a quick and disposable procedure for the detection of flunitrazepam and other nitrated benzodiazepines used in these crimes. This paper describes the application of indirect quenching of cyanine dye (Cy5) for detection of nitrated benzodiazepines. The separation is performed on a microfluidic device with a separation channel 8 cm long and 50 microm wide and utilizes indirect fluorescence detection with 635 nm laser excitation. The optimization of the separation using micellar electrokinetic chromatography with organic modifiers is described. A borate buffer containing 2.6 microM Cy5 dye, 15 mM sodium dodecyl sulphate (SDS) and 20% methanol is used. Complete separation of four target drugs occurs in under 2 min with limits of detection in the low microg/ml range. Overall the method provides a rapid and simple analysis for the presence of nitrated benzodiazepines in beverages and other similar preparations. 相似文献
6.
Karuwan C Sukthang K Wisitsoraat A Phokharatkul D Patthanasettakul V Wechsatol W Tuantranont A 《Talanta》2011,84(5):1384-1389
In this work, the use of three-electrode electrochemical sensing system with an electrowetting-on-dielectric (EWOD) digital microfluidic device is reported for quantitative analysis of iodide. T-junction EWOD mixer device was designed using arrays of 50-μm spaced square electrodes for mixing buffer reagent and analyte droplets. For fabrication of EWOD chips, 5-μm thick silver EWOD electrodes were formed on a glass substrate by means of sputtering and lift-off process. PDMS and Teflon thin films were then coated on the electrodes by spin coating to yield hydrophobic surface. An external three-electrode system consisting of Au working, Ag reference and Pt auxiliary wires were installed over EWOD electrodes at the end of T-junction mixer. In experiment, a few-microliter droplets of Tris buffer and iodide solutions were moved toward the mixing junction and transported toward electrochemical electrodes by EWOD process. A short processing time within seconds was achieved at EWOD applied voltage of 300 V. The analyte droplets mixed with different concentrations were successfully analyzed by cyclic voltametry. Therefore, the combination of EWOD digital microfluidic and electrochemical sensing system has successfully been demonstrated for rapid chemical analysis with minimal reagent consumption. 相似文献
7.
Locally enhanced concentration and detection of oligonucleotides in a plug-based microfluidic device
We propose a novel technique that allows oligonucleotides with specific end-modification within a plug in a plug-based microfluidic device to undergo a locally enhanced concentration at the rear of the plug as the plug moves downstream. DNA was enriched and detected in situ upon exploiting a combined effect underlain by an entropic force induced through fluid shear (i.e. a hydrodynamic-repellent effect) and the interfacial adsorption (aqueous/oil interface) attributed to affinity. Flow fields within a plug were visualized quantitatively using micro-particle image velocimetry (micro-PIV); the distribution of the fluid shear strain rate explains how the hydrodynamic-repellent effect engenders a dumbbell-like region with an increased concentration of DNA. The concentration of FAM (6-carboxy-fluorescein)-labeled DNA (FC-DNA) and of TAMRA (tetramethyl-6-carboxyrhodamine)-labeled DNA (TC-DNA), respectively, and the hybridization of probe DNA (modified with FAM) with target DNA (modified with TAMRA) were investigated in devices; a confocal fluorescence microscope (CFM) was utilized to monitor the processes and to resolve the corresponding 2D patterns and 3D reconstruction of the DNA distribution in a plug. TC-DNA, but not FC-DNA, concentrating within a plug was affected by the combined effect so as to achieve a concentration factor (C(r)) twice that of FC-DNA because of the lipophilicity of TAMRA. Using fluorescence resonance-energy transfer (FRET), we characterized the hybridization of the DNA in a plug; the detection limit of a system, improved by virtue of the proposed technique (the locally enhanced concentration), for DNA detection was estimated to be 20-50 nM. This technique enables DNA to concentrate locally in a nL-pL free-solution plug, the locally enhanced concentration to profit the hybridization efficiency and the detection of DNA, prospectively serving as a versatile means to accomplish a rapid DNA detection in a small volume for a Lab-on-a-Chip (LOC) system. 相似文献
8.
Li Huang Enben Su Yuan Liu Nongyue He Yan Deng Lian Jin Zhu Chen Song Li 《中国化学快报》2021,32(4):1555-1558
This device is aimed at ensuring that the sample is uniformly and equivalently reacted with the antibody on the NC membrane in each test when the microfluidic liquid system is introduced to the chip. In this study, the developed microfluidic chip can avoid the presence of the sample and conjugate pads in the chip, while the precision of the chromatography system can be greatly improved using the same particles, NC membrane and antibody alongside the traditional strip. The results, taking the detection of cTnI as an example, revealed that the coefficient of variation (CV) is controlled within 4%, while the maximum record of the contrast chromatographic reagent strip can reach 15%. Additionally, the detection sensitivity can maintain the same order of magnitudes with that of the traditional chromatographic strip. With the results, the determination correlation of the developed microfluidic chip has been greatly improved. In addition, the CV of the chip in this study is greatly improved in comparison with that of the traditional strip. The biggest improvement lies in the mixing between the sample and the microspheres, indicating that this is a new approach to improve the CV of the traditional strip. 相似文献
9.
10.
Electrochemical sensors are ideally suited for the detection of reactive oxygen and nitrogen species (ROS and RNS) generated during biological processes. This review discusses the latest work in the development of electrochemical microsensors for ROS/RNS and their applications for monitoring oxidative stress in biological systems. The performance of recent designs of microelectrodes and electrode materials is discussed along with their functionality in preclinical models of drug efficacy, mitochondrial distress, and endothelial dysfunction. Challenges and opportunities in translating this methodology to study the pathophysiology associated with various diseases are discussed. 相似文献
11.
Detection of polymerase chain reaction (PCR) products obtained from cultured greenhouse fungal pathogens, Botrytis cinerea and Didymella bryoniae has been achieved using a previously developed microfluidic microarray assembly (MMA) device. The flexible probe construction and rapid DNA detection resulted from the use of centrifugal pumping in the steps of probe introduction and sample delivery, respectively. The line arrays of the oligonucleotide probes were “printed” on a CD-like glass chip using a polydimethylsiloxane (PDMS) polymer plate with radial microfluidic channels, and the sample hybridizations were conducted within the spiral channels on the second plate. The experimental conditions of probe immobilization and sample hybridization were optimized, and both complementary oligonucleotides and PCR products were tested. We were able to achieve adequate fluorescent signals with a sample load as small as 0.5 nM (1 μL) for oligonucleotide samples; for PCR products, we achieved detection at the level of 3 ng. 相似文献
12.
Electrochemical detection has a great potential in microfluidic systems due to its easy miniaturization without losing analytical performance. In addition, the use of nanomaterials in electroanalysis improves sensitivity, selectivity, and reproducibility. The topic of this review is the use of nanomaterials (nanoparticles, nanotubes, graphene) in electrochemical detection for capillary electrophoresis and microfluidic systems (microchips and paper based analytical devices). This review covers from 2015 up to now and it is a continuation of our previous review, also published in Electrophoresis journal. The following aspects of the surveyed articles are mainly addressed: type of nanomaterial, protocol of working electrode preparation (composite, drop casting and others), advantages of nanomaterial employment and application field (clinical, food, environmental and home security). The use of nanomaterials is still an interesting approach to improve the analytical performance of electrochemical detection based on microfluidic devices. Along the review, readers will find new protocols for working electrode modification, new carbon nanomaterials and promising applications in the aforementioned fields. 相似文献
13.
Stop-flow lithography in a microfluidic device 总被引:1,自引:0,他引:1
Polymeric particles in custom designed geometries and with tunable chemical anisotropy are expected to enable a variety of new technologies in diverse areas such as photonics, diagnostics and functional materials. We present a simple, high throughput and high resolution microfluidic method to synthesize such polymeric particles. Building off earlier work that we have done on continuous flow lithography (CFL) (D. Dendukuri, D. C. Pregibon, J. Collins, T. A. Hatton, P. S. Doyle, Nat. Mater., 2006, 5, 365-369; ref. 1), we have devised and implemented a new setup that uses compressed air driven flows in preference to syringe pumps to synthesize particles using a technique that we call stop-flow lithography (SFL). A flowing stream of oligomer is stopped before polymerizing an array of particles into it, providing for much improved resolution over particles synthesized in flow. The formed particles are then flushed out at high flow rates before the cycle of stop-polymerize-flow is repeated. The high flow rates enable orders-of-magnitude improvements in particle throughput over CFL. However, the deformation of the PDMS elastomer due to the imposed pressure restricts how quickly the flow can be stopped before each polymerization event. We have developed a simple model that captures the dependence of the time required to stop the flow on geometric parameters such as the height, length and width of the microchannel, as well as on the externally imposed pressure. Further, we show that SFL proves to be superior to CFL even for the synthesis of chemically anisotropic particles with sharp interfaces between distinct sections. 相似文献
14.
A microfluidic approach for rapid bioluminescent real-time detection of single nucleotide polymorphism (SNP) is presented. The method is based on single-step primer extension using pyrosequencing chemistry to monitor nucleotide incorporations in real-time. The method takes advantage of the fact that the reaction kinetics differ between matched and mismatched primer-template configurations. We show here that monitoring the initial reaction in real time accurately scores SNPs by comparing the initial reaction kinetics between matched and mismatched configurations. Thus, no additional treatment is required to improve the sequence specificity of the extension, which has been the case for many allele-specific extension assays. The microfluidic approach was evaluated using four SNPs. Three of the SNPs included primer-template configurations that have been previously reported to be difficult to resolve by allele-specific primer extension. All SNPs investigated were successfully scored. Using the microfluidic device, the volume for the bioluminescent assay was reduced dramatically, thus offering a cost-effective and fast SNP analysis method. 相似文献
15.
High-throughput rheology in a microfluidic device 总被引:2,自引:0,他引:2
High-throughput rheological measurements in a microfluidic device are demonstrated. A series of microrheology samples are generated as droplets in an immiscible spacer fluid using a microfluidic T-junction. The compositions of the sample droplets are continuously varied over a wide range. Rheology measurements are made in each droplet using multiple particle tracking microrheology. We review critical design and operating parameters, including the droplet size, flow rates and rapid fabrication methods. Validation experiments are performed by measuring the solution viscosity of glycerine and the biopolymer heparin as a function of concentration. Overall, the combination of microrheology with microfluidics maximizes the number of rheological measurements while simultaneously minimizing the sample preparation time and amount of material, and should be particularly suited to the characterization of scarce or expensive materials. 相似文献
16.
A highly sensitive chemiluminescence (CL) method for the determination of arsenate in water based on a simple microfluidic device was developed. The method was based on sorption pre-concentration of arsenate as a form of vanadomolybdoarsenate heteropoly acid (VMoAs-HPA) ion-paired with hexadecyltrimethylammonium bromide on the surface of polystyrene beads packed in a microfluidic device monitored by chemiluminescence detection. The composition of the VMoAs-HPA complex was studied by varying the concentrations of ammonium molybdate, ammonium vanadate and sulfuric acid with a variable-size simplex optimization process, of which the optimum concentrations were 6.3 x 10(-5), 5.0 x 10(-6) and 1.0 x 10(-2) M, respectively. In this work, 1.0 x 10(-3) M ethylenediaminetetraacetic acid was added to all work solutions to remove the interferences of the other metal ions on the CL detection. The integration of sorption pre-concentration not only increased the detection sensitivity but also eliminated the interference from phosphate and chromate. The calibration plot was linear from 1.0 x 10(-7) to 5.0 x 10(-5) M As(v). The limit of detection was 8.9 x 10(-8) M As(v) (S/N = 3). The time required for one analysis run was as short as 5 min. The relative standard deviation was 5.9% (n = 9). This method was successfully applied to the determination of arsenate in mineral-, drinking- and tap-water samples. 相似文献
17.
Puigmartí-Luis J Rubio-Martínez M Hartfelder U Imaz I Maspoch D Dittrich PS 《Journal of the American Chemical Society》2011,133(12):4216-4219
One-dimensional coordination polymer nanostructures are an emerging class of nanoscale materials with many potential applications. Here, we report the first case of coordination polymer nanofibers assembled using microfluidic technologies. Unlike common synthetic procedures, this approach enables parallel synthesis with an unprecedented level of control over the coordination pathway and facilitates the formation of 1D coordination polymer assemblies at the nanometer length scale. Finally, these nanostructures, which are not easily constructed with traditional methods, can be used for various applications, for example as templates to grow and organize functional inorganic nanoparticles. 相似文献
18.
A microfluidic biosensor with electrochemical detection for the quantification of nucleic acid sequences was developed. In contrast to most microbiosensors that are based on fluorescence for signal generation, it takes advantage of the simplicity and high sensitivity provided by an amperometric and coulorimetric detection system. An interdigitated ultramicroelectrode array (IDUA) was fabricated in a glass chip and integrated directly with microchannels made of poly(dimethylsiloxane) (PDMS). The assembly was packaged into a Plexiglas housing providing fluid and electrical connections. IDUAs were characterized amperometrically and using cyclic voltammetry with respect to static and dynamic responses for the presence of a reversible redox couple-potassium hexacyanoferrate (ii)/hexacyanoferrate (iii) (ferri/ferrocyanide). A combined concentration of 0.5 microM of ferro/ferricyanide was determined as lower limit of detection with a dynamic range of 5 orders of magnitude. Background signals were negligible and the IDUA responded in a highly reversible manner to the injection of various volumes and various concentrations of the electrochemical marker. For the detection of nucleic acid sequences, liposomes entrapping the electrochemical marker were tagged with a DNA probe, and superparamagnetic beads were coated with a second DNA probe. A single stranded DNA target sequence hybridized with both probes. The sandwich was captured in the microfluidic channel just upstream of the IDUA via a magnet located in the outside housing. Liposomes were lysed using a detergent and the amount of released ferro/ferricyanide was quantified while passing by the IDUA. Optimal location of the magnet with respect to the IDUA was investigated, the effect of dextran sulfate on the hybridization reaction was studied and the amount of magnetic beads used in the assay was optimized. A dose response curve using varying concentrations of target DNA molecules was carried out demonstrating a limit of detection at 1 fmol assay(-1) and a dynamic range between 1 and 50 fmol. The overall assay took 6 min to complete, plus 15-20 min of pre-incubation and required only a simple potentiostat for signal recording and interpretation. 相似文献
19.
Chun Zhai Wei QiangJin Sheng Jianping LeiHuangxian Ju 《Journal of chromatography. A》2010,1217(5):785-789
A new method for sensitive and fast screening of melamine (MEL) in milk products was developed with a low-cost disposable microfluidic device coupled with ultraviolet (UV) detection. This method avoided the need of sample pretreatment prior to the separation process, thus was simple and green. Due to the advantages of the device and fracture sampling technique, milk sample could be directly sampled through the fracture to achieve baseline separation from amino acids, and proteins in the sample did not interfere with the detection. Using 20 mM phosphate running buffer (pH 9.0), a sampling time of 3 s at +180 V and a separation voltage of +1800 V (240 V/cm), this method could detect MEL in milk within 75 s. At the detection wavelength of 202 nm, the linear range for MEL was from 1.0 to 100 μg mL−1 with a detection limit of 0.23 μg mL−1 (S/N = 3). The novel protocol had been successfully used to screen MEL in milk samples with recovery more than 82%. The environmentally friendly methodology for pretreatment-free sensitive screening of MEL provided promising applications in monitoring the quality of different foods. 相似文献
20.
Leandro Yoshio Shiroma Murilo Santhiago Angelo L. Gobbi Lauro T. Kubota 《Analytica chimica acta》2012
The present work describes the construction and application of a simple, low cost and sensitive microfluidic paper-based device with electrochemical detection for the detection of paracetamol and 4-aminophenol. The separation channels of a width of 2.0 mm were created on paper using a wax printing process to define the regions of the device. A baseline separation level of the analytes can be obtained in 0.1 mol L−1 acetate buffer solution at pH 4.5 and by injecting 500 nL of the standard solutions at 12 mm from the working electrode. The electrochemical detection system was created at the end of the channels through a process known as sputtering. The previously separated analytes were detected at the end of the hydrophilic separation channel by applying a potential of 400 mV vs. pseudo Au on the working electrode. Experimental variables such as type of paper (cation exchanger and n1), pH, sample volume, applied potential and distance of sample injection were evaluated and, under the conditions of higher response, it was possible to obtain detection limits of 25.0 and 10.0 μmol L−1 for paracetamol and 4-aminophenol, respectively. 相似文献