首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Summary Radon measurements were carried out in a Japanese wooden house built on granitic geology, where radon-rich well water is used. Atmospheric radon concentrations were measured over one year with passive integrated radon monitors. The monitors were distributed at several locations in the house and were replaced every two months. In order to confirm the diurnal variation and heterogeneous distribution of radon, short-term measurements were carried out accordingly. Radon, its decay products and terrestrial gamma-radiations were measured in this survey. From the long-term measurement, the radon concentration in the house ranged from 14 to 184 Bq. m-3with an arithmetic mean of 45 Bq. m-3. A radon concentration of 184 Bq. m-3was observed in the bathroom in spring (March-May) though the radon level was normal in the living room and bedroom. In order to characterize the house, similar measurements were conducted in several surrounding houses. There was a significant difference in radon concentration between the investigated houses. There was a spatial distribution of the radon concentration and the highest value was found in the bathroom. Radon and its decay products concentrations varied with time, which increased from midnight to morning whereas they decreased during daytime. Although the radon concentration in tap water was 1 Bq. l-1, a high level of 353 Bq. l-1was found in the well water.While well water was being used, the indoor radon concentration near the bathroom increased rapidly with a maximum value of 964 Bq. m-3. It is clear that the use of well water enhanced the radon level around the bathroom.  相似文献   

2.
In 2013, an extensive study was performed in a total of 117 locations in Izmir province and indoor radon levels were measured using the alpha track etch integrated method with LR-115 detectors. As the maps are more practical to interpret the results of radiological survey, the distributions of indoor 222Rn activities in four most densely populated districts of Izmir were mapped in detail. It is seen that the estimated average radon concentration level (210 Bq m?3) determined in Izmir province was almost three times higher than the mean value for Turkey (81 Bq m?3). Exposed annual effective dose equivalents for Izmir province were estimated in the range of 0.7 to 12.3 mSv year?1 with a mean of 5.3 mSv year?1. In this study, it is pointed out that indoor radon concentration was affected by the age of the building and height above the ground.  相似文献   

3.
Summary Aone year survey of indoor radon and thoron concentrations was carried out in offices and dwellings of the Gunma prefecture, Japan. A passive integrating radon and thoron discriminative monitor was used in the survey. The annual mean radon concentration was 22±14 Bq . m-3, and ranged from 12 to 93 Bq . m-3 among the 56 surveyed rooms. Radon concentration in offices was generally higher than that in the dwellings, with the arithmetic averages of 29 and 17 Bq . m-3, respectively. Radon concentrations were generally lower in the traditional Japanese wooden houses than those houses built with other building materials. Seasonal variation of indoor radon was also observed in this survey. Compared to summer and autumn, radon concentrations were generally higher in spring and winter. The mean value of thoron to radon ratio was estimated to be 1.3, higher values were observed in the dwellings than in the offices. The annual effective dose from the exposure to indoor radon was estimated to be 0.47 mSv after taking the occupancy factors of offices and dwellings into account.  相似文献   

4.
In the course of routine surveillance for indoor radon in Austria, concentrations above 10,000 Bq/m3 were found in a house in the province of Carinthia, Austria. Multiple 3-day-measurements in all the rooms of the house were carried out for the next 21 months. All rooms of the house had elevated radon concentrations but radon levels decreased systematically from east to west within the house. Moreover, radon concentrations in one room of the building were found to be below 300 Bq/m3 in winter but above 12,000 Bq/m3 in summer. After installing a medium sized fan, operated only during the summer season, the semiannual summer radon levels dropped from approximately 8,000 Bq/m3 to 250 Bq/m3 at ground floor level. Note: The paper reflects the personal opinions of the authors.  相似文献   

5.
This paper presents the annual radon gas concentrations obtained during the 1994–1995 monitoring campaign using passive electret system (type E-PERM). Radon levels were measured in 154 single family dwellings, in normal occupancy conditions (open house condition) in the metropolitan zone of Mexico City. At the same time radon monitoring was performed outdoors. The results show the general log-normal distribution of integrated indoor radon concentration with an annual indoor mean of 3.8 pCi·l−1. The seasonal variations show the minimum mean values in the summer season which are 39% lower than that in autumn. Equilibrium factors (F) were measured in 12 typical houses both in autumn and winter using a continuous working level monitor for short-lived radon decay products and H-chamber loaded with a short term electret (HST, E-PERM) for radon gas. The obtained total mean equilibrium factors are:F=0.41±0.17 andF=0.29±0.04 for indoor and outdoor, respectively. A quality program was also improved.  相似文献   

6.
The temporal variation of the radon concentration, and the radon and thoron concentrations every 3 months for a year were measured using two types of devices in a landmark skyscraper, the Tokyo Metropolitan Government Daiichi Building. In the measurement of temporal variation of the radon concentration using a pulse type ionization chamber, the average radon concentration was 21 ± 13 Bq m?3 (2–68 Bq m?3). The measured indoor radon concentration had a strong relationship with the operation of the mechanical ventilation system and the activities of the office workers. The radon concentration also increased together with temperature. Other environmental parameters, such as air pressure and relative humidity, were not related to the radon concentration. In the long-term measurements using a passive radon and thoron discriminative monitor, no seasonal variation was observed. The annual average concentrations of radon and thoron were 16 ± 8 and 16 ± 7 Bq m?3, respectively. There was also no relationship between the two concentrations. The annual average effective dose for office workers in this skyscraper was estimated to be 0.08 mSv y?1 for 2000 working hours per year. When considering the indoor radon exposure received from their residential dwellings using the annual mean radon concentration indoors in Japan (15.5 Bq m?3), the annual average effective dose was estimated to be 0.37 mSv y?1. This value was 31 % of the worldwide average annual effective dose.  相似文献   

7.

This study aims to: (1) Acquire the radon level in closed office rooms, providing radon exposure data for preliminary health risk assessment of office-working population. (2) Pre-analyze the relationship between radon concentration and indoor temperature, relative humidity. (3) Estimate seasonal, annual and total radon effective dose for ordinary office-working population. The results show that the 24-h or 8-h average radon concentrations in closed office rooms were about 32.0 Bq/m3 and 29.5 Bq/m3 during detection period, and the estimated effective doses in office rooms calculated by using 24-h and 8-h average radon concentrations were all far below that in residential environment.

  相似文献   

8.
Radon and its progenies in indoor environment have been identified as the main sources of radiation dose to the people from natural radioactive sources. Presence of radon in drinking water causes radiation related health hazards both through inhalation and ingestion. In this study 36 drinking water samples from taps, boreholes and deep tube wells within the Main Campus of the University of Peshawar and adjoining area were analyzed with RAD7 electronic device for radon content determination. These water samples have a mean, maximum and minimum radon value of 8.8 ± 0.8, 18.2 ± 1.0, and 1.6 ± 0.3 Bq L−1, respectively. Eleven drinking water samples analyzed have radon levels in excess of the EPA recommended maximum contaminant level (MCL) of 11.1 Bq L−1. These include 89% from tube wells, 8% from tap water, and 50% from shallow boreholes. Radon levels of about 31% of the total samples used by the inhabitants of the study area are higher than the EPA advised level of 11.1 Bq L−1. The annual effective dose from radon in water due to its ingestion and inhalation per individual has also been estimated. The mean radon concentration and mean annual effective dose due to radon in water of this study have been compared with the mean radon concentration and mean annual effective dose of earlier investigators due to radon in water from different localities of India and Pakistan. The mean annual effective doses of all the samples are lower than the reference level of 0.1 mSv a−1 for drinking water of WHO and EU Council. It has been concluded that drinking water of the study area is generally safe as far as radon related health hazards are concerned with the exception of a few isolated cases. It has been found that radon levels within the region have a positive correlation with depth of the water sources.  相似文献   

9.
The radon concentration in the air and water of the Bizovac spa was measured by the Radhome silicon detector and the average values were obtained as 70 Bq/m3 in the indoor pool, 40 Bq/m3 in the hotel room, 135 Bq/m3 in the closed therapeutic bathroom, but the geothermal water had a Rn concentration of 25.3 kBq/m3 and the potable one 2.7 kBq/m3. The Rn transfer factor (f) from water to air in the indoor pool and therapeutic bathroom was 10 and 40 times higher than for normal dwellings (f n=10–4), respectively. The effective equivalent dose of inhaled radon for permanent personnel under the worst conditions in the spa was 5.4 mSv/y, but visitors spending two weeks in the spa could receive the dose of 77 Sv.  相似文献   

10.
The activity concentrations of 218Po, 214Pb and 214Bi [i.e. C(218Po), C(214Pb), and C(214Bi)] and the calculated concentration ratios [i.e. 1:C(214Pb)/C(218Po):C(214Bi)/C(218Po)] are necessary for assessing radon and its progenies exposure. In this study, a measurement method of radon progenies concentrations with both high sensitivity and low uncertainty, was developed based on the Kerr method. The field measurement results of radon progeny concentrations and calculated concentration ratios in both typical indoor and outdoor environments in Beijing, China, were reported. The effects of air exchange rate on concentration ratios of radon progenies in indoor environments were discussed.  相似文献   

11.
Disintegration, ventilation and deposition were considered as removal processes of the radon and its short-lived daughters in air and the respective concentration equations were applied. Calibration coefficient (KF) of the solid state nuclear track detector (SSNTD) LR-115 for radon and the equilibrium factor (F) were related to track densities of the bare detector (D) and the filtered one (Do). A useful relationship between KF, F and detector sensitivity coefficient (k) was derived. Using the calibrated value k=3.29×10–3 m, the exposed detectors gave the average values of the equilibrium factor, calibration coefficient and indoor radon concentration of a single house living room in Osijek 0.46, 142.3 m–1 and 37.8 Bq m–3, respectively.  相似文献   

12.
ABSTRACT

The purpose of this study is to estimate the concentrations of radon and heavy metals in drinking water and assess their health implications to the population of Quetta, Pakistan. The concentration of radon and heavy metals was measured in drinking water collected from tube wells of different depths of the Quetta, Balochistan, Pakistan, using RAD7 detector and Atomic Absorption Spectrometer, respectively. The results show that the concentration of radon ranged from 3.56 ± 0.98 to 8.56 ± 1.32Bq/L with an average of 5.67 ± 1.34Bq/L. The average value of contribution of radon in water to indoor air was found 2.02 ± 0.47mBq/L. In addition to concentration of radon in drinking water, physiochemical parameters like pH and electrical conductivity (EC), and annual effective doses for different age groups were also estimated. Positive correlation of (R2 = 0.8471) was observed between depth of well and concentration of radon, however no such relations were found among pH and EC with concentration of radon. Average values of annual effective doses due to intake of radon for age groups 0–1 years (infants), 2–16 years (Children) and ≥17 years (adults) were found (3.00 ± 0.71)×10?2, (1.1 ± 0.26)×10?2 and (1.45 ± 0.34)×10?2 mSv/y, respectively. Average values of heavy metals concentrations were found 1.85 ± 0.64, 3.21 ± 0.75, 5.06 ± 1.19, and 2.47 ± 0.77 and 5.58 ± 1.23 µg/L for As, Cr, Ni, Cd and Pb, respectively. The values of radon concentration and heavy metals in drinking water were found below the USEPA permissible limits, Thus we conclude that, the investigated waters are safe.  相似文献   

13.
Hot springs are famous as spa resorts throughout the world. However, these areas usually have high natural radioactivity from radon gas. In this study radon concentrations in air, hot spring water, and bottled mineral water produced in a spa area of Suan Phueng district, Ratchaburi province, Thailand were measured. Radon concentrations in air were in the range of 10–17 and 11–147 Bq/m3 for outdoor and indoor, respectively. Committed effective dose from inhale of radon were assessed and found to be in the range of 0.004–0.025, 0.25–0.6, and 1.134 mSv/y for visitor, local people and resort workers, respectively. These doses were in the range of 1.2 mSv/y regulated by UNSCEAR for the general public. Radon in hot spring water ranged from 2–154 Bq/L. Radon in bottled mineral water produced from the hot spring water were in the range of 17–22 and 0.2–0.3 Bq/L for those that stored for 7 and 90 days, respectively, after production. Radon concentration levels were in the range of the US Environmental Protection Agency reference level for radon in air which is 148 Bq/m3 and alternative maximum concentration limit (AMCL) for raw water which is 150 Bq/L. However, when considering the USEPA (Maximum concentration limit), 11 Bq/L, for radon in drinking water, the mineral water should be stored for at least 8–9 days after bottling before selling to the market.  相似文献   

14.
Gamma exposure rate and radon levels were measured in 75 single-family dwellings in Mexico City in order to correlate them with local environment. Radon monitoring was performed both indoors and outdoors using a continuous working level monitor for short-lived radon decay products; the gamma exposure rate was measured using CaSO4: Dy+PTFE. The results obtained show a log-normal distribution. The mean indoor radon concentration is lower than 45 Bq/m3 and the mean indoor gamma exposure rate was 11.29 R/h.  相似文献   

15.
The radon concentration has been measured in thermal waters used for medical therapy and drinking purposes in Yalova basin, Turkey. Radon activity measurements in water samples were performed using RAD 7 radon detector equipped with RAD H2O (radon in water) accessory and following a protocol proposed by the manufacturer. The results show that the concentration of 222Rn in thermal waters ranges from 0.21 to 5.82 Bql?1 with an average value of 2.4 Bql?1. In addition to radon concentration, physicochemical parameters of water such as temperature (T), electrical conductivity, pH and redox potential (Eh) were also measured. The annual effective doses from radon in water due to its ingestion and inhalation were also estimated. The annual effective doses range from 0.2 to 0.75 μSvy?1 for ingestion of radon in water and from 2.44 to 9 μSvy?1 for inhalation of radon released from the water.  相似文献   

16.
Although studies of radon exposure have established that Rn decay products are a cause of lung cancer among miners, the lung cancer risk to the general population from indoor radon remains unclear and controversial. Our epidemiological investigation of indoor radon influence on lung cancer incidence was carried out for 201 patients from the Osijek town. Ecological method was applied by using the town map with square fields of 1 km2 and the town was divided into 24 fields. Multiple regression study for the lung cancer rate on field, average indoor radon exposure and smoking showed a positive linear double regression for the mentioned variables. Case-control study showed that patients, diseased of lung cancer, dwelt in homes with significantly higher radon concentrations, by comparison to the average indoor radon level of control sample.  相似文献   

17.
This paper presents a method for measuring indoor radon concentrations using a commercially available air-purifying respirator filter as a component of the radon monitor. The filter used was Survivair’s NIOSH (National Institute for Occupational Health and Safety)-approved 100800 model. The method is based on the diffusion of radon gas into the activated carbon of the filter and the measurement of the radioactive daughters resulting from the radon decay. The photopeaks of the 214Bi daughter gamma rays (0.609 MeV) were analyzed with a Hyper-Pure Germanium (HPGe) detector and a multichannel system. A monotonically increasing and very close to linear response relation between the integrated area under the 214Bi photopeak and the radon concentration of the activated carbon was found. A well-defined relation held for radon levels ranging from 15 to 4,700 Bq/m3. This procedure results in highly reproducible and reliable measurements of indoor radon levels. Interesting applications include the investigation of radiological accidents involving radon and the retrospective measuring of indoor radon concentrations by analyzing the filters of the respirators worn by personnel working during the relevant period.  相似文献   

18.

In the present work, radon concentrations were measured in surface and underground water samples in Faridabad District of Southern Haryana, India using an active radon monitor based on alpha scintillation technique and results have been inter-compared. The average radon concentration in the underground water samples was observed to be 4 times higher than in the surface water samples. The estimated annual effective dose varied from 5.7 to 58.5 μSvy?1 with an average of 24.2 μSvy?1 for underground water samples and 1.1 to 12.5 μSvy?1 with an average of 6.7 μSvy?1 for surface water samples. The estimated annual effective dose for both type of samples was found to be less than 0.1 mSvy?1, which is the safe limit as suggested by World Health Organisation and EU Council.

  相似文献   

19.
Measurements of radon,thoron and their progeny in Gifu prefecture,Japan   总被引:1,自引:0,他引:1  
Summary Due to the rocky neighborhood, consisting of mostly granite with high radium content, an elevated radon concentration was found in a territory of Gifu prefecture situated in the middle of Japan. Radon concentrations in water were measured and were found to be considerably high. Since indoor radon and radon progeny concentrations might be relatively high, their concentrations were also analyzed. Besides the radon and radon progeny, thoron and thoron progeny concentrations were also investigated. Dose estimations for radon and thoron in indoor air are discussed.  相似文献   

20.
A time-independent model is presented which predicts the short-lived radon daughter activity of rainwater at ground level for unit concentration of radon (222Rn) in cloud. The model incorporates the physical processes of diffusive attachment of radon daughters and impact collection for cloud droplets by raindrops. It also includes consideration of cloud droplet and raindrop size spectra. It is concluded from the results from the model that the specific activity of rainwater is not affected very much by aerosol concentration, liquid water content, average radius of raindrops and height of cloud base but is affected markedly by rainfall rate. The radon concentrations in the rainclouds are estimated from the comparison between calculation and near-ground observations carried out for a period of almost 3 years. The result shows that the monthly geometric mean concentration ranges from 2 to 6 pCi·m?3 at Nagoya.  相似文献   